Specifications for the CMI 2409 Magnetocardiograph

Similar documents
General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

Series Environmental Chambers

Code Basic module and level control complete with optionals code

Discovery SDT 650. Site Preparation Guide. Revision G Issued December Page 1

UltraLo 1800 Alpha Particle Counter

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

LUMAZOTE T ECHNICAL BRO CHU RE

Unisys. Imagine it. Done. c Consulting. c Systems Integration. c Outsourcing. c Infrastructure. c Server Technology. Unisys NDP 30 and NDP 110

Microscopy Cryogenic WORKSTATION. Performance by Design

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Lab #1 Pressure: Bubblers and Water Balloons CEE 331 Fall 2003

Oil Diagnostic Systems. Online and bottle measurement Mobile and stationary operation Lab quality accuracy e

Discovery HP-TGA 75/750. Site Preparation Guide

PURCHASE AND DELIVERY OF A HELIUM CLOSED-CYCLE OPTICAL CRYOSTAT. The present tender is only an unofficial translation provided as a courtesy.

Level MEASUREMENT 1/2016

RM-80 respiration monitor

AUTOMATIC HOSE TEST UNIT, TYPE SPU

HPFM GEN3 - High Pressure Flow Meter

A Pulmonary Function Product of Rare Distinction

Superconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS)

DD2 Site Preparation Checklist Hardware Site Preparation Specification

THE PMI AUTOMATED GAS/HELIUM PYCNOMETER PYC-G100A

STARLOG. Capacitive Water Depth Probe

BUBBLER CONTROL SYSTEM

Dynamic Operation of a 4 K Pulse Tube Cryocooler with Inverter Compressors

American made since 1954

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

Tutorial for the. Total Vertical Uncertainty Analysis Tool in NaviModel3

Real-Time Smoothness Measurements on Concrete Pavements During Construction

RC102 & RC110 Sample in Vacuum Continuous Flow Cryogenic Workstation Cryostats

PHOENIX L300i Best-in-class Helium Leak Detectors

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist

Accurate, easy to use and reliable: Easy to use control panel. Clear, backlit LCD display: Quick connect spindles:

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION

Narkomed MRI-2. A perfect fit for the MRI environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

SCHEINWORKS Measuring and Analysis Systems by

AN31E Application Note

Residual Gas Analysis Systems for Industry

Customer Responsibilities

POROMETER 3G POROMETER. through-pore size analyzer. Membranes. Filters. Non-Woven. Textiles. Papers. Ceramics. Sintered Metals SERIES

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

ATL. Take Control of your Helium Supply. Advanced Technology Liquefier The next generation of helium recycling

MTS Restan. Automatic System for Residual Stress Measurement by Hole-Drilling

3M Electrial Markets Division EMS. Electronic Marker System

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

INTRODUCTION. The Quantum Technology system has the following advantages:, as it does not need plastic gas-bags which are volume-consuming,

HumiSys HF High Flow RH Generator

BUBBLER CONTROL SYSTEM

Modeling of Hydraulic Hose Paths

Lab 1: Pressure and surface tension. Bubblers, gravity and the mighty paper clip.

Subsonic Wind Tunnel 300 mm

FIG: 27.1 Tool String

D-Opto Dissolved Oxygen Sensor Operation Manual

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

Torque Tube TB300 Digital Transmitters

AF100. Subsonic Wind Tunnel AERODYNAMICS. Open-circuit subsonic wind tunnel for a wide range of investigations into aerodynamics

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Discovery TGA 55, TGA 550, TGA Site Preparation Guide

Sontek RiverSurveyor Test Plan Prepared by David S. Mueller, OSW February 20, 2004

Operational Settings:

Microwave Digestion System MWS-3 + Unique optical temperature and pressure monitoring of each individual sample during digestion.

CCT-7320/ROC-2313 Reverse Osmosis Controller

The Next Generation. Pulse Duplicator HDT-500. Medical Device Testing & Equipment Simulation Platforms Silicone Vessels

CONSTRUCTION OF LNG RECEIVING TERMINAL ON THE SAINT LAWRENCE TIDAL CURRENT CONDITIONS IN THE LEVIS AREA

Automatic Isokinetic Sampler. ST5 Evo

Steam Turbine Performance Measurement. Pressure Measurement

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

* Analysis of TCG ( Total Combustible Gas ) and 6 kinds of Gases * High Sensitivity for C 2

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA

HYDRAULICS. H89.8D - Hydraulic Bench

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

Dräger X-dock Frequently Asked Questions

Vehicle-mounted meters, pump supplied

Ruskinn Hypoxia and Anoxia Workstations. innovation in incubation

OPCom With laser diode Measurement range 4, 6,14 and 21 µm(c) Operating pressure up to 500 bar

Application Note 268 Metabolic Analysis Systems and Propane-based Verification

SPECIFICATION FOR AN MRBR 9.4 TESLA/310MM/AS CRYO-COOLED MAGNET SYSTEM

Heliox TM. He systems to suit all applications

Oxidation Stability of Gasoline and Aviation Fuels

CMA4000 Specifications

Customer Responsibilities

490 Micro GC Site Preparation Checklist

Series/Parallel Pumps Bench PBSPB

Customer Responsibilities

Deploying the TCM-1 Tilt Current Meter in an Inverted (Hanging) Orientation By: Nick Lowell, Founder & President

NGN Series nitrogen generator

NEED FOR SUPPLEMENTAL BATHYMETRIC SURVEY DATA COLLECTION

Installation and Operation Manual

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

STAND alone & p.c. VERSION

THE PMI ADVANCED PERM POROMETER

Capillary Flow Porometer/Frazier/C-522 CFP-1100AEX-F-C522

Advanced PMA Capabilities for MCM

High Pressure Breathing Air Compressors

Marine Towed Array Surveys of Ostrich Bay, Lake Erie and Puerto Rico.

HyperSecureLink V6.0x User Guide

THE MARKET LEADER IN CAPILLARY FLOW POROMETRY CFP1

Wärtsilä ELAC VE 5900

LUGB Vortex Flowmeter

Transcription:

Specifications for the CMI 2409 Magnetocardiograph Revision date April 14, 2006 1 518-381-1000 (tel)

The CMI-2409 system consists of a holder (A), a patient bed (B) and a workstation (not shown in the picture below). The workstation consists of a computer, monitor, keyboard, printer and SQUID system electronics power supply. Nine MCG sensors are housed in a cryostat (see Cryostat below) and the cryostat is supported in the holder. The patient lies directly below the cryostat. Location Requirements The system should be located as far as possible (at least 20 meters) from working elevators and parking lots. The system should be located as far away as possible from various sources of RF interference, e.g. ultrasound and MRI machines, microwave ovens, etc. To avoid interference with a patient measurement the minimum distance by which various items (from any direction: above, below, etc.) must be separated from the MCG Sensors is summarized in the following table. Distance Item 1.5 meters Fluorescent lights 3 meters Computer, printer, LCD monitor, MCG power supply, PDA, pager, mobile phone, small immobile metallic objects 4 meters Small fans and motors, treadmills, furnishings with movable metallic parts 8 meters Lab Centrifuges Oscillating ventilators, etc. 20 meters MRI, elevators, moving vehicles, heaters and air conditioners 2 518-381-1000 (tel)

The recommended floor space is approximately 5 m x 4 m (see drawing below: note that an LCD monitor is recommended; CRT monitors could generate electromagnetic interference; the chair shown should not contain metallic parts.) The height of the holder is approximately 2.1 m; during liquid helium refill (see Cryostat below) a recess in the ceiling (60 cm x 60 cm x 60 cm) somewhere in the MCG room is needed to facilitate insertion of a rigid tube into the liquid helium storage tank.. For floor loading considerations the weights of the main components are: o Holder (with cryostat and electronics) 160 kg o Patient bed 115 kg o The patient bed is designed to accommodate a maximum weight of 160 kg Room Layout System Power Requirements The complete system power consumption, including the computer and monitor, is 250-260 W (@ 100,120, 230, or 240V/50-60Hz). System Communication Requirements A 512 kbps or faster LAN connection is recommended to receive software updates and to access a secure location on the CardioMag server for remote service. 3 518-381-1000 (tel)

Magnetic Field Sensors System uses nine axial second-order gradiometers, each connected to its own SQUID (superconducting quantum interference device). The gradiometers are arranged in a uniform 3 x 3 grid providing 80 mm x 80 mm coverage. An MCG scan using the CMI 2409 involves four adjacent measurements to produce a 6 x 6 output with a corresponding 200 mm x 200 mm coverage area. An electronic noise suppression system (ENSS) which utilizes output from three additional SQUIDS (not linked to a gradiometer) enhances the quality of the magnetic field measurements. Top View of Cryostat Electronics The SQUID electronics module operates with 24-bit resolution and communicates with: o A liquid helium level meter in the cryostat o An ECG module mounted inside the holder via fiber-optic interface (FOI) o Bed-positioning sensors o Computer workstation for data acquisition and system control via FOI o MCG power supply 4 518-381-1000 (tel)

Cryostat The cryostat is a specially constructed non-magnetic cylindrical vessel in which the MCG sensors are housed. It is designed to safely contain liquid helium (a fluid at a temperature of -269 C) which is necessary for sensor operation. The cryostat holds 12 liters of liquid helium (55 cm fill depth). The level of liquid helium should not fall below a depth of 15 cm; otherwise MCG sensor performance may deteriorate. Consequently, it is recommended that the user add liquid helium to the cryostat twice a week, but no longer than every five days, to ensure optimum system performance. Experience shows that the annual consumption of liquid helium is 800 liters (including losses due to transfer during refilling the cryostat). Losses from an external liquid helium storage container supplied by a cryogen supplier are additional and will vary depending on the cryogen supplier and the details of the contractual supply arrangement. The equipment used/furnished by the liquid helium supplier must be compatible with the fittings supplied by CMI for the liquid helium transfer tubes. 5 518-381-1000 (tel)

Software The MCG software is specially designed for Windows XP and performs system operation, sensor adjustment and control, data acquisition at a default of 1,000 Hz, database management, data analysis and output. The details of the software capabilities are amply illustrated in a separate document. Highlighted features include Comprehensive database for patient registration and exam tracking Automatic instrument adjustment (SQUID channel adjustment) Real-time data acquisition for 13 CMI-2409 hardware channels (9 SQUID measurement, 3 SQUID reference, and 1 ECG time reference) Automatic processing of raw MCG data including temporal analysis, spectral analysis, and digital filtering Automatic time-averaging of MCG data with integrated heartbeat recognition, heartbeat template assignment, and Heartbeat comparison Two and Three-Dimensional Magnetic Field Map (MFM) Animation Magnetic Field Map Analysis Tools Inverse solver to determine Effective Magnetic Vector (EMV) source location and orientation Dynamic analysis of EMV behavior for detection of cardiac ischemia 3-D visualization of MCG Data, torso model, and heart model Analysis report printing Batch mode express processing of raw data files Batch mode EMV analysis of processed data files Conversion of MCG data to ASCII files 6 518-381-1000 (tel)