SILO SAFTEY EQUIPMENT. Silo Safety System KCS

Similar documents
SILO SAFTEY EQUIPMENT. Silo Safety System KCS

Torque Tube TB300 Digital Transmitters

AUTOMATIC GAS MANIFOLDS

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES

Pneumatic Outflow Control

solids Rotary Valves Type ZRS

Tightness controls TC 1 3 and TC 4

PRAHER PLC-MP AQUASTAR MANAUL 2009

USER GUIDE. Fog Generator. ATMOSPHERE APS Series Haze Generator. MAX APS Series. No: , Revision A/d

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

cooled, Heated ATH 2800 MT, DN 250 ISO-F, External drive electronics, Water cooled, Heated

[Instruments for vacuum measurement, checking and adjustment] 3

CCT-7320/ROC-2313 Reverse Osmosis Controller

Autocalibration Systems For In Situ Oxygen Analyzers

AUTROL 217 Expansion and pressurization Systems

Autocalibration Systems for In Situ Oxygen Analyzers

The Protection of Silos From Over. Pressurisation During Filling

Pressure switches for air and water CS

Type 4708 Supply Pressure Regulator

Flex-Kleen CT Series Pulse-Jet Dust Collectors For high pressure/high vacuum applications

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

MANUAL GAS MANIFOLDS

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2

GWB Pneumatic 2-Finger Radial Gripper Universal Gripper Sizes Weight Gripping moment Opening angle per finger Workpiece weight

PGN. Application example. Pneumatic 2-Finger Parallel Grippers Universal Grippers. Gripping force 100 N N. Sizes

Valve Proving System VDK 200 A S02

Valve Proving System VDK 200 A S06*

MoveRoll Conveyor Operating and Maintenance Manual

SPG. Application example. Pneumatic 2-Finger Parallel Gripper Heavy-load Gripper. Weight 35 kg. Stroke per finger 100 mm.

170-CG Feed Unit SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH

Automatic extractor outlet

ATH 500 M. Pumping speed ATH 500 M. 3.1 Vacuum generation / Turbopumps / Magnetically levitated / ATH 500 M. Page 398 / Part 3.1

Type 4708 Supply Pressure Regulator

Control & Maintenance. INT69 Diagnose INT69 TM Diagnose. Protect the heart of your system

Flow meter. bellow vaporizer. APL valve. Scavenging system

Liquid level instruments BM 24 /BM 51

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Type 4708 Supply Pressure Regulator

User Manual. Nitrogen generator N2 LCMS 1

Tightness control TC. Product brochure GB 3 Edition AGA

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Proportional pressure regulators VPPE

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

Pneumatic Gripping Modules. Pneumatic 2-Finger Radial Grippers

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Introduction. 1. Large oil-free screw compressor, Emeraude ALE series

VERTICAL AIR COMPRESSORS

INTERPLANT STANDARD - STEEL INDUSTRY

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

COUNTER CURRENT UNIT. Instruction Manual

Guidelines for Delivery of Bulk Cementitious Products to Premixed Concrete Plants

EPP4 Pressure Regulator Basic G 1/4"

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:

TECHNICAL DATA. Q = C v P S

RASP RX3 Feed UnitTM SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH

TECHNICAL DATA. Q = C v P S

CHECK-VALVES Automatically Position Themselves by the Natural Forces of the Conveying Air. A PNEUMATIC CONVEYING SYSTEM PATENT #: 5,160,222

GRUNDFOS alldos product information. Vaccuperm 111 / 113. Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide

PFH. Application example. Pneumatic 2-Finger Parallel Gripper Long-stroke Gripper. Weight 2.65 kg 12.6 kg. Gripping force 630 N 2950 N

Pressure switch Type BCP

INSTRUCTION MANUAL FOR. Chlorinator M 3600 C Controlmatik ABW

SCAM T.P.E. WATER TREATMENT SYSTEM SWT- AP AUTOMATIC PURGE

Automatic Control Unit. Controlmatic E.2. Type Series Booklet

PFH. Application example. Pneumatic 2-Finger Parallel Grippers Long-stroke Grippers. Sizes Gripping force 510 N N

DPZ-plus. Application example. Pneumatic 3-Finger Centric Grippers Sealed Grippers. Gripping force 520 N N. Sizes

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

CanNeed-DSST-100 Digital Secure Seal Tester --- To evaluate the secure seal quality of PET bottles, glass bottles and cans

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Manual Actuated Boiler Blowdown Valves

Pressure Automated Calibration Equipment

Operating Instructions Part No

INSTALLATION OPERATION MAINTENANCE

REASONS FOR THE DEVELOPMENT

Maintenance and Troubleshooting of Pneumatic Conveying Systems for Sand in a Foundry

TECHNICAL DATA. Q = C v P S

PSH (inch version) Application example. Pneumatic 2-Finger Parallel Grippers Long-stroke Grippers. Stroke per finger 14 mm.. 64 mm. Sizes 22..

TGD-L (LP) Tank Gauging Device TGD L (Level) TGD LP (Level Pressure) Main features:

Screw Compressors 11-22kW

ELADOS EDP L Diaphragm Metering Pump Type

Measurement of Low GAS & Liquid Flows

LVU2800 Series. Ultrasonic Level Transmitter

HYDRA-line. HYDRA-Gauges Ultra High Purity Pressure Gauge Model HG. Pressure Systems. Applications. Special features. Description

What is LPG? Released Energy in the narrowest area. Clean and sure in the practise

South-Tek Systems - Nitrogen Generation Corrosion Inhibiting System. Designed for: Dry or Preaction Fire Protection Systems (FPS)

MICRO DIAPHRAGM GAS PUMPS

Pneumatic Grippers Swivel Modules

Pneumatic Target Transfer System Model PT01

Deltaflux Control Valve

TECHNICAL DATA. Q = C v P S

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

VERTICAL AIR COMPRESSORS

Safety and Shut-off Block SAF/DSV

The Discussion of this exercise covers the following points:

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13

Transcription:

SILO SAFTEY EQUIPMENT Silo Safety System KCS

Silo Safety System KCS 1 The Ultimate Solution for PROBLEM-FREE PLANT OPERATION DURING SILO FILLING BY TANKER Damage to silos and accessories is most likely during tanker filling operation due to the risk of overfilling or excessive pressurisation. The KCS Silo Safety System, which comes in component form, prevents both overfilling and excess pressure, thus avoiding damage to the silo, the venting filter or any other accessories, at the same time reducing the risk of dust emission. SC-TOUCH CONTROL PANEL SC-HUB CONTROL PANEL The SC-TOUCH and SC-HUB manages information received from various silos and can be connected via Ethernet to the plant s PC or PLC. 4 VM / VMM PINCH VALVE VM / VMM Pinch Valve used to shut off silo filling pipe SC-TOUCH SC-HUB The control panel (usually installed in the control room of the plant) monitors each silo as regards: - Connection to silo - Internal pressure of any silo - Maximum level indicator free - Presence of compressed air to filter (if SILOTOP by WAM or similar is used) - Presence of compressed air to pinch valve - Monitoring up to 32 silos simultaneously, maintaining control of the process status of each silo - In case of an alarm condition in any silo the system will automatically monitor the situation even if another silo is tracked at the same time Main Voltage: 110-230 V AC (fixed values) 5 6 VM Pneumatically Actuated Pinch Valve VMM Mechanically Actuated Pinch Valve When necessary, instantaneously cuts off air and material flow through filling pipe at any time. XKF COUPLING FLANGE Connects pinch valve with silo filling pipe. VMX01 N / VMX01M PINCH VALVE CONTROL PANEL VMX01N and VMX01M are pneumatic panels for VM and VMM pinch valve control 2 SP2 POWER PANELS Each silo is equipped with an SP2 Power Panel which includes cable connections to all the system components. 3 KAT TANKER COUPLING PIPE For coupling of material filling hosepipe to safety flange. Installed on silo filling pipe flange. 7 VMX enables: - Open / Close air supply to pinch valve by means of solenoid valve - Adjust control pressure to pinch valve - Get information on pressure line between solenoid valve and pinch valve Power supply: 24V AC, 50/60 Hz AIR LINE PRESSURE SWITCH Sends signals on absence of compressed air in plant line for pinch valve control unit. KAT 100 B KAT 100 A / KAT 080 A KAT 100 C

Protection Against Excess-Pressure and Dust Emission 12 11 9 13 14 10 8 2 7 6 4 1 3 5

8 11 ILTA0 ROTATING LEVEL INDICATOR Designed to indicate presence of material in the silo, bin or hopper. Commonly used for materials with a minimum density of 0.3 t/m³. SILOTOP VENTING FILTER SILOTOP is a cylindrically shaped dust collector for venting of pneumatically filled silo Power Voltage: 24 V AC Used to detect: - Silo Full level - Silo Empty level - Intermediate or re-ordering level 12 Power voltage: 24 V AC Dust separated from the air flow by special POLYPLEAT filter elements drops back into the silo after an integrated automatic reverse air jet cleaning system inside the weather protection cover has removed it from the filter elements. PF12 FILTER PRESSURE SWITCH Sends signal to silo control panel on absence of compressed air for filter elements cleaning. 9 IPE / IPM PRESSURE MEASURING DEVICE Available as mechanical IPM4001 or IPE electronic version IPE (Electronic Pressure Meter): Continuously reads pressure inside the silo during filling through electric signal output. Signal range optionally 0-20 ma (IPE1) or 4-20 ma (IPE5). Pressure range: 0-99 cm H 2 O 13 ASSEMBLY: screwed on SILOTOP filter by means of connector. Preset pressure switch: 4.5 bar VCP / VHS PRESSURE RELIEF VALVE VCP / VHS Pressure Relief Valves are used in all plants where it is required to control excess or negative pressure that may occur inside the silo, thereby preventing any possible damage. IPM (Mechanical Pressure Switch): Installed on top of the silo, indicates when critical pressure threshold is exceeded. Pressure threshold: 40 cm H 2 O with IPM4001 10 IPX STUB PIPE CONNECTION Enables correct assembly of IPM pressure switch or IPE pressure meter on top of the silo. All Pressure Relief Valve models can be provided with an inductive signalling system. In the activation phase the signalling device generates an instantaneous signal so that the valve returns to its home position after the action. The use of a device to maintain this signal is recommended. 14 LS AUDIBLE ALARM The LS Audible Alarm provides an acoustic signal in case of any malfunction. ASSEMBLY Must be welded on the roof or on the side of the silo, after providing suitable circular opening. MATERIAL: carbon steel FINISHING: spray-painted RAL 9010 (pure white) - Supply voltage: 110-230 V, 50 Hz. - Sound level: 98 db(a) - Protection: IP66

Application Benefits Avoid damage to silo and accessories; Reduce risk of air pollution; Eliminate risk of filling the incorrect silo; Start and stop filter cleaning automatically; Receive indication from electronic pressure meter whether filter might need attention; Benefit from control panel monitoring of: - Internal pressure of any silo - Maximum level indicator free - Presence of compressed air to venting filter (if air jet filter is used) - Presence of compressed air to pinch valve

October 2014 Rights reserved to modify technical specifications. www.wamgroup.com