130400A 1/2 NPT Female A 3/4 NPT Female A 1 NPT Female A 1 1/4 NPT Female A 1 1/2 NPT Female A 2 NPT Female

Similar documents
553 Series.

differential pressure regulating valve - threaded

Pressure independent control valve (PICV) FLOWMATIC

Function. size 1-¼ inch: 9-¾" size 1-½ inch: 11-¼" size 2 inch: 12-¾" A A A A A/96A A/99A

Scald Protection Three-Way Thermostatic Mixing Valve

Function. brass EN CW617N brass EN CW617N brass EN CW614N. brass EN CW614N brass EN CW617N EPDM

Scald Protection 3-Way Thermostatic Mixing Valve

STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves

VARIABLE ORIFICE BALANCING VALVE PN 25 TECHNICAL DATA SHEET. Approved by*: Main features:

STAG. Balancing valves Balancing valve with grooved ends DN

Installation, commissioning and servicing instructions

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

BSA6T and BSA64T Stainless Steel Bellows Sealed Stop Valves Installation and Maintenance Instructions

Pressure Independent Control Series

CALEFFI. Flow rate metering device. 683 series 01040/10 GB. Function

Balancing Valves. Applications/ Features: Ordering Information: Accessories:

STA. Double regulating valves DN 15-50

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

STAD. Balancing valves DN 15-50

Differential Pressure Control Valve (DPCV)

Pre-adjustable pressure reducing valves

STAD Series. Balancing and control valves. Technical Data Sheet. WattsIndustries.com

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

132 Series. QuickSetter+ Balancing Valve with flow meter NA Function

DS05C,D,G Dial Set Pressure Regulating Valves

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Series V48. 3-Way Pressure Actuated Modulating Valves. Product Bulletin. Features. Pressure balanced design. Free movement of all parts

DN 1/2" to 2" Female BSP + 0 C C Max Pressure : 16 Bars Specifications : Stainless steel removable filter Female / Female With draining valve

WHEATLEY Series 500 Swing Check Valve

CALEFFI. Motorised temperature regulating unit for heating systems. 167 series 01239/15 GB. replaces dp 01239/13 GB. Function

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

Products no longer available

Pressure Reducing Valve DMV 750 set range: bar

Thermocirc Installation and Maintenance Instructions

CALEFFI. Pre-adjustable pressure reducing valves with self-contained cartridge series 01085/17 GB. replaces 01085/14 GB

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

STAD. Balancing valves DN (MD60, MD61, MD62)

Precision and Instrument Regulators 1/4" port size

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

Regulating valves Type REG 6-65 Type REG-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

6301 TYPE CAST IRON SAFETY VALVES

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve. ANSI version

STA. Double regulating valves DN 15-50

2-port seat valves PN25 with externally threaded connections

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions

Instructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and position.

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

Engineering Data Sheet

Regulating valves REG-SA and REG-SB

D05 Pressure Regulating Valves

Overflow valves Type OFV REFRIGERATION AND AIR CONDITIONING. Technical leaflet

UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions

V43 Pressure Actuated Water Regulating Valve

Hand-operated regulating valves in stainless steel Types REG-SA SS and REG-SB SS

BTD52L Thermodynamic Steam Trap Installation and Maintenance Instructions

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

Wilo Triple Duty Valve / Triple Service Valve Installation and operating instructions

Model MC Circuit Setter Hose Kits Supply Valve Options: Ball Valve, UBY

Instrument Operating Manual

CAST IRON SAFETY VALVE TYPE 6301

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

STAD-C. Balancing valves DN 15-50

TA10A and TA10P Steam Tracing Temperature Control Valves Installation and Maintenance Instructions

Pressure Relief Valve DHV 718

Bermad Pressure Reducing. Model: 42T

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

AE50S Automatic Air and Gas Vent for Liquid Systems Installation and Maintenance Instructions

STAINLESS STEEL OVERFLOW VALVE TYPE 417

STV / STVL. Danfoss STV series of balancing valves provide testing and balancing of circuit flow for hydronic heating or cooling systems.

TD10, TD52M and TD259 Thermodynamic Steam Traps Installation and Maintenance Instructions

1.0 - OPENING AND CLOSING THE DOOR

WHEATLEY Series 822/820 Swing Check Valve

INSTALLATION & MAINTENANCE INSTRUCTION

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Two-port seat valves

Overflow valves Type OFV Type OFV-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

STAP. Differential pressure controllers DN , ANSI flanges

Aquor House Hydrant V2

Pure-Flo Handwheel Operated Valves (903, 913, 963) Instruction Manual

Pressure Reducing Valve DMV 755 set range: 1,0-9,0 bar

Engineered Valves Group. Revision 2. FABRI-VALVE High Performance Knife Gate Valve.

FT16 Ball Float Steam Trap Installation and Maintenance Instructions

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

Pressure Dump Valve Service Kit for Series 2300 Units

CA16 and CA16S-14 Air and Gas trap Installation and Maintenance Instructions

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Pre-adjustable pressure reducing valves with self-contained cartridge

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

Three-port valves. Special versions with special stem sealing gland for: High temperature hot water C Thermo oils

PV4 and PV6 Piston Valves

Two-port valves, male threaded, PN25

STAP. Differential pressure controller DN 15-50

750 Cable Cutter INSTRUCTION MANUAL

776 Cryogenic Safety Valve

INSTALLATION GUIDE MODEL NUMBER X. UniMaxx-Plus-SC-500-AC-V3 UNIMAXX SOLAR PUMP STATION

Transcription:

88.0A www.caleffi.com Venturi Style Balancing Valve Copyright 0 Caleffi 0 Series Function Product Range Balancing valves are hydraulic devices that can precisely control the flow rate of the fluid that supplies a system s emitters. Hydraulic circuits must be correctly balanced to ensure that the system operates at the design conditions and provides a high level of heat comfort with low energy consumption. For the 0 series valves, the flow rate is measured by a Venturi port designed into the body of the valve. This guarantees accurate setting as well as ease of use during calibration. 0 000A / NPT Female 000A / NPT Female 000A NPT Female 0700A / NPT Female 0800A / NPT Female 0900A NPT Female Technical Specifications Performance Material: Body: Low-lead brass Bonnet: Low-lead brass Control stem: Low-lead brass Valve plug: stainless steel Seal seat: brass Hydraulic seals: EPDM Stem guide bearing: PTFE Knob: PA0 Pressure test ports: brass body, EPDM seal elements Reduction of Lead in Drinking Water Act Compliant: 0.%. weighted average lead content. Reduction of Lead in Drinking Water Act Certified by IAPMO R&T. Suitable fluids: Water and glycol solutions. percentage of glycol: 0% imum working pressure: psi ( bar) Working temperature range: - - 0 F (-0 0 C) Accuracy: ±0% Number of adjustment turns: Connections: Main: Valve body pressure test ports: / NPT female / NPT female Technical specifications of insulation Material: closed cell expanded PE-X Thickness: ½ inch ( mm) Density: - inner part:.9 lb/ft (0 kg/m ) - outer part:.0 lb/ft (80 kg/m ) Thermal conductivity (ISO 8): - at F (0 C): 0. BTU in/hr ft F (0.08 W/(m K)) - at 0 F (0 C): 0. BTU in/hr ft F (0.0 W/(m K)) Coefficient of resistance to the diffusion of water vapour (DIN ): >,00 Temperature range: - F (0-00 C) Reaction to fire (DIN 0): Class B

SAFETY INSTRUCTION This safety alert symbol will be used in this manual to draw attention to safety related instructions. When used, the safety alert symbol means ATTENTION! BECOME ALERT! YOUR SAFETY IS INVOLVED! FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN A SAFETY HAZARD. CAUTION: All work must be performed by qualified personnel trained in the proper application, installation, and maintenance of systems in accordance with all applicable codes and ordinances. CAUTION: Over-tightening and breakage can occur with the use of Teflon pipe joint compounds. Teflon provides lubricity so that care must be exercised not to over-tighten joints. Failure to follow these instructions could result in property damage and /or personal injury. WARNIN: System fluids are under pressure or temperature can be hazardous. Be sure the pressure has been reduced to zero and the system temperature is below 00 F (8 C). Failure to follow these instructions could result in property damage and/or personal injury. Caleffi shall not be liable for damages resulting from stress corrosion, misapplication or misuse of it products. Installation A B PSI Assembly and disassembly of the valves should always be conducted while the system is cold and not pressurized (fig. A). Install according to the flow direction indicated by the arrow on the valve body (fig. B-C). In order to ensure measuring accuracy, the balancing valve must be installed by keeping an upstream straight section of at least five diameters, increased to at least ten diameters if the nearest device upstream is a pump (fig. D). C D

Operating Principle The opening position is indicated by two numbered indicators (fig. E): - The turn indicator () shows a flow rate scale from 0 to (0 closure, maximum flow rate, completely wide open flow) in red. Turning the knob manually through 0 causes the indicator to click by one unit. - The micrometric control indicator () shows numbers in black from 0 to 9. Each change in this number represents /0 of an opening/closing turn of the valve with respect to the turn indicator (). E Use of the balancing valve: setting the flow rate (fig F-) NOTE: the indications + and on the drawings refer respectively to the pressure test ports upstream and downstream of the Venturi port inside the valve. F For the connection of the pressure test ports of the valve () with a differential pressure measuring device (), use a pair of fittings with fast-plug syringe () ( Caleffi 00 series) (fig. F).

a) As the thermal fluid passes, measure the Δp of the valve wany suitable differential pressure measuring device(fig. ); b) Using the Hydraulic characteristics sheet (sheet code 89 supplied in the pack), find the flow rate value that is passing through the valve, consulting the Venturi diagram Δp-flow rates corresponding to the size of the valve used. c) Turn the knob and repeat steps a) and b) until you reach the desired value. Correction for liquids of different densities If using liquids with a density different from water at 70 F (0 C). lb/ft ( kg/ dm), correct the value of the measured head loss Δp using the following formula: Δp = Δp water where: Δp = reference head loss in (psid(kpa)) Δp = measured head loss in (psid(kpa)) = fluid density in lb/ft (kg/dm ) Memory Stop on the balancing valve After balancing the flow rate, insert a. mm hexagonal spanner in the hole (7), turn counter-clockwise until the red indicator (8), initially not visible, is aligned with the top edge of the knob, without forcing it. This operation allows you to close the valve and open it again until the set value is reached (fig. H ). H 9 8 7 NOTE: the sticker (9) on the top of the knob indicates: Yes =Memory stop on; No =Memory stop off.

Locking/sealing the setting position (fig. I) I L 0 Installing Insulation Apply the insulation and close with the Velcro (0) already installed (fig. L). M For installations with chilled water, seal with suitable adhesive (fig. M). Maintenance If broken, the knob of the valve can be replaced. - Extract from the adjusting knob assembly the two parts () and () that make up the knob. Fully turn the valve stem () clockwise with a 7 mm hexagonal spanner and fully turn the Memory stop indicator () clockwise, without forcing it, using a. mm hexagonal spanner (fig. N). - Prepare the spare knob in control position 0 0 (). Manually insert the knob () in the adjusting knob assembly, until it automatically locks (fig. O). N O

CAUTION: If the balancing valve valve is not installed, commissioned and maintained properly, according to the instructions contained in this manual, it may not operate correctly and may endanger the user. CAUTION: Make sure that all the connecting pipework is water tight. Caleffi North America, Inc. 88 West Milwaukee Road Milwaukee, WI 08 T:.8.0 F:.8. 09--

88.0 000A / NPT Female 000A / NPT Female 000A NPT Female 0700A / NPT Female 0800A / NPT Female 0900A NPT Female www.caleffi.com Copyright 0 Caleffi Venturi chart (water) p.00 0.00 0.00.00.00.00.0.00 0.0 0.0 0.0 (feet of head) 0..0 0..0.0.0.0 0 0..8 0. 00 (psi) 0 0 0. 0. 0. 0. 0.. 00 (bar).0 0. 0. 0. 0. 0. 0.0 0.0 0.0 0. 0.0 0.00.0 0..0 Valve size / / / / 0.0 0.0 0.00 Size /" /" " /" /" " Venturi..0.0 7..80.78

88.0 000A / NPT Female 000A / NPT Female 000A NPT Female 0700A / NPT Female 0800A / NPT Female 0900A NPT Female www.caleffi.com Code 000A / inch Code 000A / inch Code 000A inch.00 0.00 0.00.00.00.00.0.00 0.0 0.0 0.0 0..0.0 0. 0..0.0.0.0 0 0..8 0 00. 0.0 00 0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0.0 0.0 0.0 0. 0.0 0.00.0...... 0.0 0.0 0.00.00 0.00 0.00.00.00.00.0.00 0.0 0.0 0.0 0..0.0 0. 0..0.0.0.0 0 0..8 0 00. 0.0 00 0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0.0 0.0 0.0 0. 0.0 0.00.0...... 0.0 0.0 0.00.00 0.00 0.00.00.00.00.0.00 0.0 0.0 0.0 0..0.0 0. 0..0.0.0.0 0 0..8 0 00. 0.0 00 0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0.0 0.0 0.0 0. 0.0 0.00.0...... 0.0 0.0 0.00 Size /" 0......7.0...8.7.0....8 Size /" 0......8...8...8...8.9 Size " 0......08.8.7..0.8... 7. 8.87 Code 0700A / inch Code 0800A / inch Code 0900A inch.00 0.00 0.00.00.00.00.0.00 0.0 0.0 0.0 0..0.0 0. 0..0.0.0.0 0 0..8 0 00. 0.0 00 0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0.0 0.0 0.0 0. 0.0 0.00.0... Size /" 0........7.87.7.9.7 7. 8. 9. 0..07. 0.0 0.0 0.00.00 0.00 0.00.00.00.00.0.00 0.0 0.0 0.0 0..0.0 0. 0..0.0.0.0 0 0..8 0 00. 0.0 00 0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0.0 0.0 0.0 0. 0.0 0.00.0.... Size /" 0....... 0.0 0.0 0.00.89..07.7.9 8.7 9.97..8.0 9.7.00 0.00 0.00.00.00.00.0.00 0.0 0.0 0.0 0..0.0 0. 0..0.0.0.0 0 0..8 0 00. 0.0 00 0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0.0 0.0 0.0 0. 0.0 0.00.0.... Size " 0....... 0.0 0.0 0.00.0.8.9 8. 0.7.. 8.8.. 0.8