Operating Instructions Temperature Measuring System MF420-5T-100

Similar documents
Technical Data Sheet MF010-O-LC

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

GasSense NDIR User Manual

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Mounting instructions. Strain transducer SLB-700A. B 26.SLB700A.10 e

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

PH01 Perfusion Cannula Manual

PRAHER PLC-MP AQUASTAR MANAUL 2009

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

Operating Instructions

Operating Instructions

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

T EK-SUB 4800C 19 mm Submersible Level Transmitter

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Type BBS-03, BBS-05, BBS-06, BBS-25

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Transmitter CS 21 Operation Manual

Digital Melting Point Apparatus

Installation and Maintenance Instruction Manual

Instruction Manual Contact Pressure Vacuum Gauge

JUMO dtrans p30 Pressure Transmitter

Transmitter CS 21 Operation Manual

Please read these instructions carefully before use! Please consider the safety instructions! Please keep for future reference!

Instruction Manual Differential Pressure Transmitter

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Operation Manual. Hand tool for AMP DUOPLUG Customer Manual PN: en (Translation of the original German version)

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

DK48 - DK800. Quick Start. Variable area flowmeter

KERN EG/EW Version /02

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

Operating and maintenance manual Filter and reducing station Series / 1.0

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

OPERATING INSTRUCTIONS (Translation) Rope Winch Type , , ,75

FPD20 Series. Gear wheel flow sensor

OXY 3690 MP. Measuring transducer for air oxygen

KGW - ISOTHERM. Operating Instructions. Level controlling device for liquid nitrogen LEVEL CONTROL LN2

3G Operating instructions. Digital Purge Gas Valve 3G Type: Document no.: D0001 Version: 01. July 2011/Rev.

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027

SDX Submersible Depth Transmitter User Manual

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

Instruction Manual BA90 Precision Barometer

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual

Operating Instructions - Rescue Equipment. RAM Support LRS-T EN Edition (translation of the original operating instructions)

High-performance submersible pressure transmitter For level measurement Model LH-10

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

Rigel 601 CHECKBOX. Instruction Manual. 348A551 Issue 2.0. April Seaward Electronic Ltd. Issue 2.0

A17W49_MASEM_F_EN MANUAL

Supplementary Operator s Manual 42/24-14 EN Rev. 3

INSTRUCTION MANUAL Pressure Relief Device LPT

New AQF Filter Polymer Filtration System

Siphon vessel / Priming aid

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

SDX Submersible Depth Transmitter User Manual

Repair instructions. Pivot bushing replacement. XL-AS10001RM-en-DE Rev B

GEMS SENSORS & CONTROLS

Safety instructions and operating manual

Translation of the original Operating Instructions for HKS rubber compensators

Gas density monitor With integrated transmitter Model GDM-100-TI

EC214 EC215 - EC215R Bench Conductivity Meters

Instruction Manual Differential Pressure Transmitter

Precision pressure sensor Basic version Model CPT6020

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

User Manual PTW-DensiX. D / Di/Zi

High-performance submersible pressure transmitter For level measurement Model LH-10

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

testo Leakage detector for refrigerants Instruction manual

Operating Instructions of BROSA tension load cells, types 0111, 0113

Installation & Maintenance Instructions TEC-11N TIMER. Analogue electronic timer 02/09

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

Operating Instructions in accordance with the Machines Directive 2006/42/EC

DTG - LCD Digital Temperature Gauge USER MANUAL

Pressure maintenance valve SDV-P / SDV-P-E

HI 2314 HI 2315 HI 23151

Operating Instructions Melt Pressure Sensor

OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

CP10 Sensor Installation and Maintenance Instructions

ELECTRICAL (COMPREHENSIVE) SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29 CFR CFR , ,

12V Mini Air Compressor

! Warning, refer to accompanying documents.

Arran LED Floodlight Luminaire

Air Purge Unit. Series: LSP-compact Type: EJG 2-2. (Controlled with DigiFlow 515) Installation & Operation Manual 11/2014

Contents. Operating instructions. Pressure switch, heavy-duty version Model PSM-520

SIL Safety Manual. ULTRAMAT 6 Gas Analyzer for the Determination of IR-Absorbing Gases. Supplement to instruction manual ULTRAMAT 6 and OXYMAT 6

Assembly, Installation and operating. instructions for. Söll-Xenon anchorage device

Included with Smoothcut Plasma 100 machine. Plasma 100 Torch Operating manual

Innovative Vacuum for Automation. Operating Instructions Dust Filter STF P / STF-D P.

Operating Manual VSA100A. tina29e1 ( )

deltaflowc deltaflowc Venturi or Probe

DK46 - DK800 Supplementary instructions

HSE guidelines. SMay 2015 ELECTRICAL SAFETY HSE LIFE THE NATIONAL OIL&GAS INDUSTRY STANDARD FOR PROFESSIONALS

Pressure transmitters EMP 2

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

Electro-Pneumatic Converter YT-940 SERIES

Climatic Independent Level Sensor LAR

Transcription:

Operating Instructions Temperature Measuring System Dnhqdhnjah MF420-5T-100 Dmsklakla Read before use! Observe all safety instructions! Keep for future reference! Fon +49/7221/64103 Fax +49/7221/17103 www.dittrich-systeme.de info@dittrich-systeme.de - 1 -

Table of contents 1. For your safety...2 1.1 Safety information and tips...3 1.2 Intended use...4 1.3 Other dangers...5 1.4 Qualification of personnel...5 2. Product description...6 2.1 Design of the temperature measuring system...6 2.2 Principle of operation...7 2.3 Technical data...7 2.4 Certification...8 3. Transport and installation...8 3.1 Transport...8 3.2 Storage...9 3.3 Installation...9 3.4 Electrical connection...10 4. Operation...12 4.1 Commissioning...12 5. Maintenance and servicing...12 6. Decommissioning...13 7. Packaging and transport...13 8. Disposal...13 9. Appendix...14 9.1 Spare parts and accessories...14 9.2 Copyright...14 9.3 Warranty...14-1 -

1. For your safety Observe the instructions for use Any person handling or operating the temperature measuring system must first be fully familiar with and observe these instructions for use. The temperature measuring system is to be used only for the described purpose (see section 1.2). Servicing The temperature measuring system must be inspected and serviced regularly by qualified specialists. Repairs to the temperature measuring system must only be carried out by qualified specialists. (See sections 1.4 and 5.) Do not operate in areas subject to explosion hazards The temperature measuring system is not approved for operation in areas subject to explosion hazards. Do not operate it in any areas where combustible or explosive gas mixtures are likely to occur. WARNING! These operating instructions do not contain all the information necessary for the safe operation of the device. Please acquaint yourself with the regulations and operator's obligations that apply in your area. In addition to these operating instructions, for example, you should observe and instruct others concerning the universally valid legal and other binding regulations for the prevention of accidents and protection against accidents. If there is any doubt regarding the information contained in this translation, the German wording shall apply. - 2 -

1.1 Safety information and tips A series of warnings is used in these instructions concerning some of the risks and dangers that may occur when using the temperature measuring system. These warnings contain "signal words" designed to draw attention to the degree of danger that is to be expected. These signal words and the associated hazards are as follows: DANGER! Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. This signal word is to be limited to the most extreme situations. WARNING! Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION! Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. Indicates information concerning use and other useful information. - 3 -

1.2 Intended use The temperature measuring system MF420-5T-100 is designed for measuring the temperature profile in compost heaps. The temperature measuring system MF420-5T-100 must be used exclusively for: Measuring temperature profiles in a gas/solid mixture in a range from 0 C to +100 C. The temperature measuring system MF420-5T-100 is not suitable for determining the temperature of liquids. It is essential that the temperature measuring system is installed only as described in section 3.3 and that the ambient conditions specified there (e.g. temperature limits) are adhered to! WARNING! Danger of fire and explosion due to sparks! The temperature measuring system MF420-5T-100 may not be operated in areas where ignitable or explosive gas mixtures can arise. The temperature measuring system must only be opened and repaired by the manufacturer. Do not modify the temperature measuring system and do not reconstruct it. It may otherwise no longer measure reliably. The measuring signals from the temperature measuring system must be evaluated and further processed by the user's downstream device. It is essential to observe the information given in these operating instructions with regard to operation, maintenance and servicing. Faults must be rectified immediately. - 4 -

1.3 Other dangers Despite its careful design, there remain some further dangers associated with handling the temperature measuring system. The following are known to us: DANGER! Mains voltage (230 V, 50 Hz). Danger to life due to electric shock or burns. Do not bring into contact with water. The housing must only be opened by the manufacturer. Electrical work should only be carried out by a qualified electrician. Only install in a voltage-free state. WARNING! The bar probe is very sharp. Risk of injury! Wear protective gloves. Always store the device such that the tip cannot cause injury. Never use the device as a weapon and never throw it. You might spear someone and kill them. 1.4 Qualification of personnel Only qualified mechatronic engineers or persons with comparable training may mount, install or commission the temperature measuring system or carry out maintenance and servicing work. Only qualified electricians may carry out work on the electrical system. (In Germany according to German VDE!) The operator must instruct all users of the system on the basis of these operating instructions. The minimum age is 16 years. An experienced person must supervise juveniles and apprentices when working on the temperature measuring system. Any work that is not described in these operating instructions must be executed by the manufacturer. - 5 -

2. Product description 2.1 Design of the temperature measuring system Insertion probe / bar probe Fig. 1: Temperature measuring system MF420-5T-100. The temperature measuring system MF420-5T-100 (see Fig. 1) has been specially developed for use in composting plants. The materials used are suitable for the difficult requirements posed by such an environment: the bar probe and handles on the right and left-hand side of the lower part of the housing are made of stainless steel. The transmitter functions according to the two-wire system and is contained in a red aluminium housing. The cover and bottom of the housing are connected by means of a sealing ring and four stainless steel screws. Screw locking paint prevents unauthorised opening of the housing. Additionally, the pressure compensation element and the connecting plug are located on the aluminium housing. The device must only be opened by the manufacturer! - 6 -

The output signals from the temperature measuring system are read and further processed according to the customer's specifications in a downstream device. 2.2 Principle of operation The temperature measuring system MF420-5T-100 determines the temperature profile within a gas/solid mixture from 0 C to +100 C. To do this, the temperature is determined at 5 measuring points by 5 Pt100 sensors,that are evenly distributed along a measuring distance of 1 m. The 5 measured values are output via 5 linear current outputs (4-20 ma); the power supply is 24 V direct current. For normal applications the temperature measuring system is maintenance-free. 2.3 Technical data Transmitter Power supply 7-pole plug-in contact Amphenol-Tuchel circular connector Voltage 24 V DC ± 5% Electric current Approx. 120 ma Connections Pin 1 (in) 24 V DC ± 5% Pin 2 (out) Pin 3 (out) Pin 4 (out) Pin 5 (out) Pin 6 (out) Pin 7 Temperature T1 (100 mm) Temperature T2 (350 mm) Temperature T3 (600 mm) Temperature T4 (850 mm) Temperature T5 (1100 mm) Functional ground Ambient temperature -10 C to +50 C Sun can heat up the housing considerably! Air pressure 900 hpa to 1100 hpa Output 5 x 4-20 ma Temperature T1 to T5, max. load 500 Ω Housing Aluminium Red Protection class of housing Size (with handles) IP 54 Approx. L320 x W100 x H80 mm Without handles Ø 100 mm - 7 -

Bar probe Length Diameter Approx. 1,150 mm Approx. 23 mm Material Stainless steel 1.4301 Total weight Approx. 3,500 g Transmitter + insertion probe Permissible humidity 15 to 95% rel. humidity Non-condensing Ambient temperature Sensor Measuring range 0 C to +100 C 0 C to +100 C Accuracy ± 2 % at 25 C FS (full scale) Reproducibility ± 1 % Reaction time Type of protection - sensor Approx. 5 min IP 54 2.4 Certification The temperature measuring system complies with EMC Directives EN 61000-6-2 and EN 61000-6-3 and thus Directives 89/336/EEC and 92/31/EEC. 3. Transport and installation 3.1 Transport The temperature measuring system is supplied together with these operating instructions. Please check the packaging for any damage when the product is delivered and report any damage immediately to the forwarding agency and dealer. The temperature measuring system should not be thrown or dropped as it could be damaged or scratched. Protect against wet conditions, humidity, dirt and dust. - 8 -

3.2 Storage The temperature measuring system may be stored in its packaging in dry rooms at temperatures between +10 C and +50 C. Protect it against wet conditions, humidity, dirt and dust. The caps on the plug-in contacts must be securely closed. 3.3 Installation WARNING! The bar probe is very sharp. Risk of injury! Wear protective gloves. Always store the device such that the tip cannot cause injury. Never use the device as a weapon and never throw it. You might spear someone and kill them. Remove the temperature measuring system from the packaging and firmly screw the enclosed handles onto the red housing. The temperature measuring system has to be inserted into the compost in such a way as to prevent any possible condensate flowing into the probe electronics. The insertion angle must therefore be between 90 and 45. Maximum insertion depth Insertion angle 90-45 Fig. 2: Installation of MF420-5T-100. - 9 -

When installing, it is essential to remain within the following permissible ambient conditions: Ambient temperature of housing between -10 C and +50 C (please bear in mind that under certain circumstances the sun can heat up the housing considerably!). Ambient temperature of insertion probe between 0 C and +100 C. The housing must be freely accessible and visible at all times. The temperature measuring system must not be installed in damp locations or areas subject to explosion hazards. Parasitic voltages must not be permitted to occur. 3.4 Electrical connection DANGER! Mains voltage (230 V, 50 Hz). Danger to life due to electric shock or burns. Do not bring into contact with water. The housing must only be opened by the manufacturer. Electrical work should only be carried out by a qualified electrician. Only install in a voltage-free state. The measuring system and central unit must be connected with a permanent, microbeproof, seven-core, shielded cable (diameter 9-11 mm) (see Fig. 3). Do not lay this line next to a high-tension power cable as there is a danger of radiated interference. The cable must be capable of withstanding the anticipated mechanical, chemical and thermal stresses. Connect the temperature measuring system to the electric circuit via Pin 1 and Pin 7 (see Fig. 3) and read off the measured data via Pin 2 to Pin 6 (each 4-20 ma), for example with the help of a measuring instrument, a display or a PLC (programmable logic controller). - 10 -

There must be a constant supply of power to the temperature measuring system, otherwise condensate will form and this can destroy the temperature measuring system. 1 U +24V DC 7 2 Funktionserde T1 4-20mA T1 T2 6 5 7 1 2 T3 3 T2 4-20mA 4 3 T4 4 T3 4-20mA T5 5 T4 4-20mA 6 T5 4-20mA Fig. 3: Pin assignment of MF420-5T-100. CAUTION! In accordance with existing safety regulations, the temperature measuring system must only be connected to suitable power supply units that comply with the valid technical regulations. It must be ensured that fuse protection is provided that is suitable for the power supply units used (SAFE ELECTRICAL ISOLATION)! - 11 -

4. Operation 4.1 Commissioning Before commissioning use the following list to check whether all requirements for trouble-free operation are met: Has the temperature measuring system been installed? Is the temperature measuring system accessible and visible in the compost heap? Has the ambient temperature been taken into account? Has the temperature measuring system been connected? Is the power supply switched on? Are you sure that the connection cable is not laid next to high-tension power cable? Please bear in mind that this is a sensitive measuring instrument! Next, carry out a test of the measured values. To do this, pull the insertion probe out of the compost and hold it in fresh air for 5 minutes. Then check the measured values on the downstream device. If they are approximately equal (± 2% of full scale) and plausible, the device is ready for use. Prepare a commissioning report (see section 5.3, Warranty). 5. Maintenance and servicing DANGER! Mains voltage (230 V, 50 Hz). Danger to life due to electric shock or burns. Do not bring into contact with water. The housing must only be opened by the manufacturer. Electrical work should only be carried out by a qualified electrician. Only install in a voltage-free state. The temperature measuring system must only be opened and repaired by the manufacturer. Do not modify the temperature measuring system and do not reconstruct it. It may otherwise no longer measure reliably. - 12 -

The temperature measuring system and the connecting cable must be checked at least every six months by qualified personnel (see section 1.4) and a servicing report must be prepared. This check should always include a check of the measured values (see section 4.1). If the measured values are outside the range of 0 C to +100 C, there is a cable break or short circuit. Always ensure that the interval between services meets safety requirements! The measured values should likewise be checked after each period of non-use. Make appropriate checks to ensure that the temperature measuring system and its surroundings are clean, accessible and visible at all times. Above and beyond such measures the temperature measuring system is maintenance-free. 6. Decommissioning Switch off the power supply, remove the temperature measuring system from the compost and clean it carefully (do not use a steam jet cleaner!). Afterwards, check if there is any damage. Please refer to section 3.2 for information on storage. 7. Packaging and transport This device is a measuring instrument with sensitive electronic components. When returning it, please use the appropriate class of packaging according to the applicable regulations. 8. Disposal Obsolete devices should be rendered unusable immediately and disposed of according to the relevant regulations. Please contact your local authority for information about disposal. - 13 -

9. Appendix 9.1 Spare parts and accessories Spare parts Pressure compensation element, part no. 100-010 Cap, part no. 100-004 Housing handle, part no. 080-033 Accessories Connecting cable, 20 m, part no. 100-009 Socket for connecting cable, part no. 09-4226-14-07 9.2 Copyright The copyright to these operating instructions is exclusively reserved to J. Dittrich Elektronic GmbH & Co. KG. Reproduction, translation and duplication in whole or in part without written authorisation is strictly prohibited. 9.3 Warranty We the manufacturer grant a warranty for this device for a period of 6 months from commissioning, documented by a commissioning report. Within this warranty period we will at our discretion repair or replace the device free of charge if found to be defective as to workmanship or material. The warranty excludes: damages attributable to improper use, normal wear, and defects that have only a negligible influence on the device's value or suitability for use. Liability for the functioning of the temperature measuring system shall pass at all events to the owner or operator if the temperature measuring system is improperly maintained or repaired or if it is used other than for its intended purpose. J. Dittrich Elektronic & Co. KG accepts no liability for damage caused by failure to observe the above information. - 14 -

The warranty expires in the event that work is carried out by agents we have not authorised or if parts are used other than original spare parts. Claims under the warranty may be made in all countries where this device is sold by authorised dealers. In the event of any claim under the warranty, please return the device to us. The buyer shall bear the costs of transportation and the risk while the device is in transit. The execution of work under the warranty does not affect the warranty period in any way. The manufacturer accepts no liability for printing errors or any damage resulting therefrom. The above information does not extend the conditions of warranty and liability contained in the Terms and Conditions of Sale and Delivery of J. Dittrich Elektronic GmbH & Co. KG (corresponding to the Terms and Conditions of Sale and Delivery for Sensor Technology, AMA Fachverband für Sensorik e. V.). Subject to change without notice. (03/08) J. Dittrich Elektronic GmbH & Co. KG, Baden-Baden, 2008. - 15 -