Aging Effects in Cathode Strip Chambers of CMS at Large Hadron Collider: Chemistry and Recovery

Similar documents
Extension of the operational lifetime of the proportional chambers in the HERMES spectrometer

The Resistive Plate Chamber detectors at the Large Hadron Collider experiments. Danube School, September 8-13, 2014 Novi Sad

A Longterm Aging Study of the Honeycomb Drift Tubes of HERA-B Using a Circulated and Purified CF -Gas Mixture

Analysis of RPC Performance with Different Gas Mixture

Performance of a triple-gem detector for high rate charged particle triggering

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

Additives that prevent or reverse cathode aging in drift chambers with Helium-Isobutane gas *

Assembly and Testing of RPCs in Pakistan. Hafeez Hoorani National Centre for Physics

EFFECTS OF OUTGASSING FROM SOME MATERIALS ON GAS CHAMBER AGEING

ETCHING OF COPPER COATED MYLAR TUBES WITH CF4 GAS. Karl M. Ecklund, Keith W. Hartman, Michael J. Hebert, Stanley G. Wojcicki

ATLAS RPC QA results at INFN Lecce

arxiv: v1 [physics.ins-det] 16 Aug 2014

EUROPEAN LABORATORY FOR PARTICLE PHYSICS STUDY OF AGEING AND GAIN LIMITS OF MICROSTRIP GAS CHAMBERS AT HIGH RATES

Design and Construction of a GEM-TPC Prototype for R&D Purposes

Preliminary results of Resistive Plate Chambers operated with eco-friendly gas mixtures for application in the CMS experiment

Investigation of Cr Etch Chamber Seasoning Pavel Nesladek a, Guenther Ruhl b, Marcel Kristlib b

PHENIX RPC in China. Xiaomei LI. Science and Technology on Nuclear Data Laboratory China Institute of Atomic Energy

arxiv: v1 [physics.ins-det] 6 May 2016

arxiv: v1 [hep-ex] 18 Sep 2012

Experience with the ZEUS central tracking detector

Quartz etch process to improve etch depth linearity and uniformity using Mask Etcher IV

Plasma Cleaner. Yamato Scientific America. Contents. Innovating Science for Over 125 Years. Gas Plasma Dry Cleaner PDC200/210/510 PDC610G.

Yoke Instrumentation: ILD Muon System / Tail Catcher. Valeri Saveliev IAM, RAS, Russia DESY, Germany 3 June, 2016

Pressure Sensitive Paint (PSP) / Temperature Sensitive Paint (TSP) Part 1

Development of Cleaning and Processing Techniques for UHV/XHV at Daresbury Laboratory Keith Middleman

RPC CHARACTERIZATION AND TESTING ( by S. Mathimalar, INO Student)

The SPI Sputter Coater Handbook

Characteristics and Production of Gas Sealed, Radiation Hard, Small Ionization Chambers

STS Advanced Oxide Etch DRIE System Trends

TPC Report. D. Karlen T2K ND280m meeting December 7, 2004 Rome

TOTAL-IONIZING-DOSE RESPONSE OF 65 nm MOSFETS IRRADIATED TO ULTRA- HIGH DOSES. GIULIO BORGHELLO

Annex 1 Gas circulation / purification system

On the possibilities for the readout of gas scintillation detectors for neutron scattering applications

The use of remote plasma emission spectroscopy as an alternative method of gas sensing for direct monitoring of vacuum processes

AN EXPERIMENTAL AND ANALYTICAL STUDY OF PLASMA CLOSING SWITCHES FILLED WITH ENVIRONMENTALLY FRIENDLY GASES

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION

Vacuum Science and Technology in Accelerators

Improved Sputter Depth Resolution in Auger Thin Film Analysis Using In Situ Low Angle Cross-Sections

APPLICATION OF A CHANNEL PLATE IN FIELD-ION MICROSCOPY

Long term stability tests of INO RPC prototypes

Study of the IBF of Double/Triple THGEM

Approved by Principal Investigator Date: Approved by Super User: Date:

The Gas Team and the LHC gas systems: introduction. 11/10/2018 R. Guida on behalf of the Gas Team 1

Dissolved Oxygen Guide

Leaks, contamination and closed loop control how RGAs make coating processes more profitable

Status of MDT Production and Testing

Guideline for RMO Key comparison for Air kerma rate in 60 Co gamma radiation

Alice TPC Review Short Summary

A Journal of Practical and Useful Vacuum Technology. By Phil Danielson

arxiv: v1 [physics.ins-det] 4 May 2016

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

Combining NEG pumps and an XHV BNNT cryopump

Residual Gas Analysis Systems for Industry

REACTIVE ION ETCHING OF SILICON DIOXIDE USING BOTH OXYGEN AND CARBON DIOXIDE AS GAS ADDITIVES. dames E. Constantino ABSTRACT

Practical approach and problems in in-situ RGA calibration

Performance of the Liquid Hydrogen Target

GIF++ A New Gamma Irradiation Facility

Technical Specifications of Hydrogen Isotope Handling and Recovery System

MANUAL FOR SPTS APS (DIELECTRICS ETCHER)

Outgassing. the hows and whys of measurement. Ron Reid ASTeC Vacuum Science Group STFC Daresbury Laboratory UK

Plasma Sources and Feedback Control in Pretreatment Web Coating Applications

Remote Plasma Cleaning from a TEM Sample Holder with an Evactron De-Contaminator ABSTRACT

Supporting Information for Micro-Collection of. Gases in a Capillary Tube: Preservation of Spatial

March CS-1701F Reactive Ion Etcher

Plasma Asher: March PX-500 User guide (May-30, 2017)

GAS ANALYSIS AND MONITORING SYSTEMS

CHAPTER 4 PRE TREATMENT PATIENT SPECIFIC QUALITY ASSURANCE OF RAPIDARC PLANS

Introduction of Vacuum Science & Technology. Diffusion pumps used on the Calutron mass spectrometers during the Manhattan Project.

Development of small, easy to build and low gas consumming timing RPCs

A Study of Spatial Resolution of GEM TPC with Ar-CF 4 -ic 4 H 10 Gas Mixtures

TECHNICAL ADVISORY Helium Enhanced Oxygen Monitoring Aberration Phenomena July 20, 2001

Monitored Drift Tubes in ATLAS. Michele LIVAN 1. Dipartimento di Fisica Nucleare e Teorica, Universita di Pavia

Barrier Development and Evaluation Methodology. D.S. Musgrave 1 1 Thermal Visions, Inc., Granville, USA

Dissolved Oxygen and measurement possibilities. Berno Lüpkes, 15 th March 2017

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

Outgas of Methane from NEG Coating

Contamination Removal of EUVL masks and optics using 13.5-nm and 172-nm radiation

High Performance Mass Spectrometers

Impact of low energy helium irradiation on plasma facing metals

The Principles of Vacuum Technology

Notes-PECVD: Chamber 1

Users days 20&21 october 2011 In situ TEM investigation of helium bubble evolution in SiC at high-temperature under displacing irradiation

Figure 1 The LHC cryogenic islands and plants layout

The Transition Radiation Detector of the AMS-02 Experiment

O3 3E 1 F Gas Sensor Module

Recirculating Coolers

Inert Atmosphere Guide

Figure 1. Schematic view of the magnetic spectrometer.

High Aspect Ratio DRIE on the STS ICP-RIE

Quantification of Contamination Using Quartz Crystal Thickness Monitors

Max Planck Institute, Munich. January 10, Because of the concern about long-term silicon contamination of MDTs, we

NEULOG OXYGEN LOGGER SENSOR GUIDE

Plasma-Therm PECVD. Operating Characteristics. Operating Instructions. Typical Processes. I. Loading. II. Operating

Jefferson Lab Bubble Chamber Experiment Update and Future Plans. C(a,g) 16 O. Claudio Ugalde

RESEARCH OF LEAK DETECTION SYSTEMS WITH ACCUMULATIVE MEMBRANES

UK Opportunities in SiD Calorimetry

Effects of the electric field on the electron drift velocity in a double-gem detector in different gas mixtures

Experimental characterization of HET and RIT with atmospheric propellants

Cryo-Evaporator Operation

3. Coupled Techniques in Thermal Analysis

Transcription:

Aging Effects in Cathode Strip Chambers of CMS at Large Hadron Collider: Chemistry and Recovery VI. Aggravation of aging problems by I. Aging studies in CSC CMS. limitation of GHG. II. Malter current in LHCb muon VII. Conclusion. chambers: statistic; recovery methods. III. Malter currents: examples observed at CSC CMS. IV. Malter currents: observation at GIF++. V. Targeting aging test in PNPI: Aging test results; SEM/XEM analysis. 12/6/2016 G.Gavrilov, PNPI, Gatchina, RF 1

17th February 2011 Fergus Wilson, RAL 2

CSC s Malter current and HL-LHC Historical summary: CSC CMS, Ar/CO2/CF 4 (40 : 50 : 10) 1998 Local aging test of first CSC prototype ( 90 Sr - Q~12 C/cm, 75 Volume/day+ Q~2 C/cm 1 Volume/day); 1999 - Aging test of 1m prototype on GIF ( 137 Cs Q=0.218 C/cm, 1 Volume/day); 2000-2001 - Aging test of full-scale CSC chamber on GIF ( 137 Cs Q=0.35 C/cm, 1 Volume/day); 2010 First signs of MCE in the ME1/1 (V.Perelygin DOC Report 25.04.2012). From 2016 Ongoing aging test of full-scale CSC chamber on GIF++ ( 137 Cs Q ~ 0.175 C/cm, 1 Volume/day); 2016 - Local benchmark aging test of CSC prototype ( 90 Sr Q ~ 1.36 C/cm, 3.5 Volume/day). CSC LHCb, Ar/CO2/CF 4 (40 : 55 : 5) 1998 2000, M1R2 and M2/3 R1/R2-5 regions, passed through the conditioning with HV(-) on GIF before installation (336 gaps). In total 2582 gaps (52.2%); 2010-2016 Ongoing training procedures for recovering from Malter current. 12/6/2016 G.Gavrilov, PNPI, Gatchina, RF 3

CSC s Malter current and HL-LHC Working gas mixture Ar(40%) CO 2 (50%) CF 4 (10%) in CSC s longevity tests demonstrated perfect protection of the anode wires. BUT. Presence of CF4 in gas mixture does not prevents cathode surface from occurrence of the insulating layer. Therefore with dose accumulation and start of HL-LHC beam the CSC degradation danger is mainly related with Malter effect. Early diagnostic with monitoring HV system and training procedure to cure MCE have to be developed. 12/6/2016 4

12/6/2016 G.Gavrilov, PNPI, Gatchina, RF 5

Malter current effect is Malter current effect (MCE) is secondary electron emission which appears when: 1. an insulating layer exists on the cathode, 2. the rate of ion build-up is higher than its removal from the insulating layer, 3. some ignition mechanism take place Manifestation of MCE: 1. self-sustained discharge ignited by high intensity irradiation and micro sparks; 2. sustained O(1) A current independent from external irradiation; 3. spurious signals which hard to see in data or DQM (can be too small, DAQ is LST driven). Curing is possible: Make cathode again conductive by - Adding water/alcohol vapours (not good for FR4 cathode strips); - Clean (etch) insulating layer with training at presence of O,F and CF 3 Wait until insulating layer rises up to 1 m (??) For 10 A insulating layer ΔV = 1V provides E = 10 7 V/cm 12/6/2016 G.Gavrilov, PNPI, Gatchina, RF 6

12/6/2016 G.Gavrilov, PNPI, Gatchina, RF 7

Malter current effect (MCE): why worry Malter current effect may by assumed as a local current of 1 A per 1 cm of wire length. Then dq/dl = 1 A/cm 10 7 s/year 1 year = 10 C/cm But already at dq/dl ~ 2-4 C/cm it is very real to obtain anode wire swelling, that cause a rapid drop of the signal amplitude. That is: T. Ferguson e t c, NIMA 515 (2003) 266 277 T.Akesson et al. NIMA 515(2003) 166-179 12/6/2016 8

Since of 2010 the training procedures take place: I. during the beam irradiation and continues from few hour up to few days; II. without beam with normal and inversed HV that takes up to few weeks and sometimes needs additional treatment with beam; III. 4 not amendable to recovery modules have been successfully treated using working gas mixture with 2% O 2 2010 1.8 % Gaps 2011 2.4% Gaps 2012 2.8% Gaps 2015 0.5% Gaps at the same Lumi as in 2012 but time of operation was very short. 12.09.16 2.9% (144) Gaps. situation is stable and looks very promising: only two new gaps tripped from 30.07.2016 MUON system has 4944 gaps in 1368 MWPCs Malter currents LHCb CSC: recovery experience and remedies Gas mixture -Ar/CO2/CF4 (40 : 55 : 5) Gas Gain ~ 46-88 000 at HV 2520-2630V Oleg Maev, LHCb General meeting, 12 September 2016 12/6/2016 G.Gavrilov, PNPI, Gatchina, RF 9

Malter currents MUON LHCb: samples I. MCE curing procedure on the beam consists in keeping of the Malter current until it drops down at the level below of the HV trip threshold. For the training the threshold is specially raised up to ~40 A Criteria of goodness : no dark current at HV(+)=+2.85kV and HV(-)=-2.3kV Malter currents MUON LHCb: recovery samples Oleg Maev II. MCE curing procedure without beam is similar to the previous with beam, but includes the training with inversed high voltage as well. During each long period for access (>4 days) the most problematic gaps had been treated with negative polarity. Gas mixture -Ar/CO2/CF4 1. СF 4, CO 2 dissociation under interaction with e => production of F, O, CF 3 CF 4 + e - CF 3 + F + e - CO 2 + e- CO + O + e- 2. => etching of Si, SiO 2 => SiF 4 4F + Si SiF 4 4F + SiO 2 SiF 4 + O 2 3. => desorption of SiF 4 molecules from the cathode due to external irradiation The training with HV(-) in situ passed 2354 (47.6%) gaps in MUON system. In addition, 5 regions, M1R2 and M2/3 R1/R2, passed through the conditioning with HV(-) on GIF before installation (336 gaps). In total 2582 gaps (52.2%) 12/6/2016 G.Gavrilov, PNPI, Gatchina, RF 10

Malter Malter currents currents MUON MUON LHCb: LHCb samples III. MCE curing procedure is similar to the previous without beam, but in Ar/CO2/CF4 (40 : 55 : 5) 2% of Oxygen is added. Malter currents MUON LHCb: recovery with 2% O 2 adding Removal of organic polymeric material with oxygen containing plasma (H. Boeing, Plasma Sci.&Tech., page 281, (1987). Cleaning of mirrors contaminating films by a glow discharge in oxygen plasma. (R. Gillette et al., Vac. Sci. Tech., 7(1070)534) Recovery from the Malter effect deposits by Oxygen (A. M. Boyarski, Additives That Prevent Or Reverse Cathode Aging in Drift Chambers With Helium-Isobutane Gas, Nucl. Inst. And Meth. A515, 190-195(2003). M. Blom, I. Mous, and N. Tuning, Effects of adding oxygen to the outer tracker gas mixture, LHCb, vol. 064, 2008 G.Gavrilov, PNPI, Gatchina, RF D.Maysuzenko, O. Maev 11

Malter currents: examples observed at CSC CMS L= 7.1 10 33 Hz/cm 2 L= 7.0 10 33 Hz/cm 2 12/6/2016 12

Malter currents: CSC CMS Summary: The number of the MCE touched chambers may increase at HL-LHC. We need an early diagnostic based on HV monitoring system. From LHCb CSCs experience follows that recovery techniques for CMS CSC s can be useful. Laboratory tests with small scale prototypes are actual for this purpose. 12/6/2016 G.Gavrilov, PNPI, Gatchina, RF 13

12/6/2016 G.Gavrilov, PNPI, Gatchina, RF 14

Malter currents: at GIF++ Malter currents (GIF++ off) versus Dose at the limit of CAEN resolution ME1/1 - tree layers with Malter behavior - two of them under irradiation - on in a good correlation with occupancies no accumulated charge dependence seen so far ME2/1 - one channel with an obvious Malter current - in a good correlation with rates whether improves with time?.. will see... K. Kuznetsova 12/6/2016 G.Gavrilov, PNPI, Gatchina, RF 15

A good indicator for early MCE diagnostic Note: It is one of three ME1/1 from CMS re-tested at GIF++ to localize MCE 12/6/2016 G.Gavrilov, PNPI, Gatchina, RF 16

CSCs SUMMARY Malter currents potentially can deliver a local charge per unit of wire length O(1000) times larger than that due to the nominal HL-LHC irradiation in the hottest chamber areas. We plan to develop a standard analysis of HV data looking for appearance of Malter currents in each fill and their evolution over time: large steps in currents during fills residual currents right after end of fills and before HV goes to standby. Early detection of Malter currents and development of mitigating action upon their identification is absolutely vital for the longevity of CSCs. Local fast aging study using the small scale CSC prototypes both in CERN and PNPI is necessary to study the phenomena, develop recovery techniques and to look for eco-friendly gas mixture. 12/6/2016 G.Gavrilov, PNPI, Gatchina, RF 17

Targeting aging test in PNPI o Local aging test under 90 Sr irradiation is performed with compact CSC prototype module fed by standard CSC gas mixture; o Accumulated charge 1.36 C/cm is obtained, that is 7x of the expected charge after 3000 fb -1 at HL-LHC. The absence of amplitudes degradation matches with the previous tests; o Strip-to-strip resistance dropped during the aging test from 5 10 13 up to 5 10 7 ; o Despite of the strong oxidation and Si coating on cathodes surface, no MCE manifestation have been detected; o Test results can be a benchmark for the future study of the eco-friendly gas mixtures; 12/6/2016 G.Gavrilov, PNPI, Gatchina, RF 18

2 planes, each with 7 controlled anode wires; 50 m gold-coated anode wire; 285 x 340 mm 2 sensitive area, 1670 cm 3 gas volume; S = 3 mm ; L = 4.5 mm ; Identical geometry and construction materials to CSC ; Strip resistance control at specially cut strips on the cathode plane ; Gas flow during aging test was 4 sccm, that is 3.5 Volume per day ; No gas recirculation was applied. BUT B.P. KONSTANTINOV PETERSBURG NUCLEAR PHYSICS INSTITUTE Gatchina, Russia Small scale CSC prototype module for aging study * Readout from anode wires only ; * - HV applied to the cathode.

CSC CMS prototype longevity test Motivation: o o o Targeting test up to Q ~1.5 C/cm for longevity evaluation at HL-LHC luminosity; Benchmark test for new gas mixtures studies; Study of the cathode aging phenomena. Reference layer after aging run Irradiated layer after Q =1.36 C/cm 20

CSC CMS prototype longevity test An aging degradation is observed on the cathode planes. This manifested itself with dark currents and interstrip resistance drop. But. Gas gain stayed stable and no HV trips observed!

CSC CMS prototype longevity test Photos of the disassembled detector after accumulation of Q=1.36 C/cm Centre of the irradiated zone Traces of liquid (plasticizers from FR4?) 12/6/2016 22

CSC CMS prototype longevity test 12/6/2016 G.Gavrilov, PNPI, Gatchina, RF 23

Optical microscope image Sample E Dark spot rich F, O and C with Si traces White substance rich F, C and O with Si and Ca traces Relatively clean area rich in Cu, O, F, C and Si traces SEM image

CSC CMS prototype longevity test 12/6/2016 25

CSC CMS prototype longevity test in PNPI 12/6/2016 G.Gavrilov, PNPI, Gatchina, RF 26

12/6/2016 G.Gavrilov, PNPI, Gatchina, RF 27

12/6/2016 G.Gavrilov, PNPI, Gatchina, RF 28

12/6/2016 G.Gavrilov, PNPI, Gatchina, RF 29

Наконец заключение Появление токов Мальтера (МЭ) в катодных пропорциональных камерах CSC мюонного трекера CMS стало наблюдаемой реальностью. Ситуация может ухудшиться после перехода коллайдера LHC на более высокую светимость в режим HL-LHC (5 10 34 cм -2 сек -1 ). Методы устранения МЭ тренировки есть и они успешно испытаны. Но только на детекторах в эксперименте LHCb. Нет пока результатов восстановления для камер CSC. Ведутся попытки восстановления отдельных модулей (которые имели МЭ с момента работы на LHC) на на GIF++. Планируется проводить разработку методов восстановления и в ОФВЭ ПИЯФ. Возможности быстро, до 2025 г., создать экологически безопасную газовую смесь для камер CSC, видимо, нет. Но можно радикально сократить размеры выбросов парниковых газов мюонного трекера CMS. Эти работы ведутся в ОМК ОФВЭ. 12/6/2016 G.Gavrilov, PNPI, Gatchina, RF 30

BACKUPS 12/6/2016 G.Gavrilov, PNPI, Gatchina, RF 31

12/6/2016 G.Gavrilov, PNPI, Gatchina, RF 32

12/6/2016 G.Gavrilov, PNPI, Gatchina, RF 33

Aging results from GIF (1999) Cu O F Si D. Acosta et al. NIMA 515 (2003) 226 233 12/6/2016 G.Gavrilov, PNPI, Gatchina, RF 34

SEM image of the copper surface of original not irradiated FR4 Force microscopy of original FR4 12/6/2016 G.Gavrilov, PNPI, Gatchina, RF 35