Electro-Pneumatic Positioner Explosion Proof / Intrinsically Safe

Similar documents
Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

SSR. Smart Valve Positioner.

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

SSL. Smart Valve Positioner.

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

Electro-Pneumatic Converter YT-940 SERIES

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

Type 4708 Supply Pressure Regulator

I/P Transducer Positioner Module

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

General Specifications

Pressure Measurement Single-range transmitters for general applications

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

Smart performance with innovative and ever-strong coil drive even under harsh working environments

Pressure Measurement Single-range transmitters for general applications

Mechanical Pressure Measurement

Bourdon tube pressure gauge for diaphragm seals

IPH 2 & IPX 2. Features Type 4X & Explosion-Proof Current-to-Pressure (I/P) Transmitters. Approved for Use with Natural Gas.

Tapped exhaust port. Sturdy, simple, reliable design. Easy to add on Feedback. High gain pilot valve. Simple calibration, external zero adjustment

Level transmitter LT 100

General Specifications

Type 4708 Supply Pressure Regulator

OPTIBAR P 1010 C Technical Datasheet

Type 4708 Supply Pressure Regulator

TYPE APPROVAL CERTIFICATE

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

General Specifications

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Pressure switch with bourdon tube

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Technical Specifications

Technical Data. Dimensions

JUMO dtrans p30 Pressure Transmitter

Level sensing relative and absolute pressure transmitter type 712

INDUSTRIAL. Pressure Transmitters. Product Guide. Low cost to high accuracy portfolio. Ranges from 70 mbar to 1400 bar. Flexible, rugged and reliable

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-10

Torque Tube TB300 Digital Transmitters

Technical Data. General specifications. Rated operating distance s n 5 mm

Liquid level instruments BM 24 /BM 51

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

ATM.1ST/Ex - High Precision Transmitter

High-performance submersible pressure transmitter For level measurement Model LH-20

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

Relative pressure transmitter type 520

Technical Data. Dimensions

Technical Data. Dimensions

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Electro-Pneumatic Positioner YT-1000L (Linear Type)

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

ATM.ECO/IS - Analog Transmitter with Temperature compensation

High-performance submersible pressure transmitter For level measurement Model LH-20

Siemens AG psi (6 bar) 145 psi (10 bar) 464 psi (32 bar) 1450 psi (100 bar) 3626 psi (250 bar) 8700 psi (600 bar) psi (800 bar)

Technical Data. Dimensions

Technical Data. Dimensions

Prewired position switches FA series

Differential pressure

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

High-performance submersible pressure transmitter For level measurement Model LH-10

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

GA24 Technical Datasheet

C-Flow Coriolis Mass Flow Meters

EP500 Advanced ATEX Electropneumatic Positioner

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

CERTIFICATE OF COMPLIANCE

Level switches Series LD Vibrating fork level switch for liquids and solids

Pressure transmitter PASCAL Ci4

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

SITRANS P measuring instruments for pressure

Level switches Series LD Vibrating fork level switch for liquids and solids

V83 series Redundant valve manifold systems - Modular with bypass 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Electro-Pneumatic Positioner TZIDC-200, TZIDC-210, TZIDC-220

Pressure & Temperature Switches

Certificate of Compliance

sitrans p Operating Instructions (de/en) Edition 03/2004

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Pressure switch KP-E. Data sheet

FTC FasTrak Compact INSTRUCTION MANUAL 4049

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

VPPC02, VPPC08 3-way proportional pressure control valve, electronic closed loop control

Assembly instruction. Operating temperature range -60 C +85 C Protection. IP 66, 67, 68 (5 bar)

RTX 1000H Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control. Features

ARI-DP32 / DP33 / DP34 / DP34T / DP34Tri / DP35 Pneumatic actuator ARI-DP

Operating Instructions Melt Pressure Sensor

Transcription:

Product Specifications 07.2015 PSS EVE0103 A-(en) SRI983 Electro-Pneumatic Positioner Explosion Proof / Intrinsically Safe The SRI983 Positioner is for operation of pneumatic valve actuators from control systems and electrical controllers with electric control signals. It is used to reduce the adverse effects of valve friction, for higher thrust and shorter positioning time. FEATURES Independent adjustment of stroke range and zero Adjustable amplification and damping Split range up to 3-fold possible One version for 4-20 ma input Supply pressure up to 6 bar (90 psig) Low vibration effect in all directions Mounting according to IEC 534, part 6 (NAMUR) Rotation adapter for angles up to 120 Explosion protection: II 2 G Ex d and II 1 G Ex ia according to ATEX, or explosion proof, intrinsic safety acc. to FM / CSA EMC in accordance with the international standards and laws (CE)

2 SRI983 PSS EVE0103 A-(en) TECHNICAL DATA Input Signal range...4...20ma Input resistance...<260ω Stroke range...8...100mm(0.3...4in) Angular range linear....30...120 equal percentage...90 ;from70 linear Output Outputtoactuator...0...100% supply air pressure Supply Supply air pressure...1.4...6bar(20...90psig) Air supply....according to ISO 8573-1 - Solid particle size and density class 2 - Oil rate class 3 - Pressure dew point 10 K under ambient temperature The use of filter regulator for air supply of positioner is strongly recommended. It reduces the air pressure to actuator s maximum pressure and keeps it constant. Ambient conditions Ambient temperature... 40 C( 40 F)to... (see page 3) Relative humidity...upto100% Operating conditions as per IEC 654-1...Thedevicecanbeoperated at a class Dx location Transport and storage temperature... 40...80 C( 40...176 F) Protection class pneumatic part...ip54 electrical part ATEX...IP65 FM+CSA...NEMA4X Electromagnetic compatibility EMC Operating conditions...industrialenvironment Immunity according to - NAMUR recommendation NE21 fulfilled -EN61326...fulfilled - EN 61 000-6-2...fulfilled Emission according to - EN 55 011, Group 1, Class A...fulfilled - EN 61 000-6-2...fulfilled CE marking Electromagnetic compatibility...2004/108/ec Low-voltageregulation...notapplicable Response characteristic 1) Amplification...adjustable Sensitivity...<0.1%F.S. Non-linearity (terminal based adjustment)...<1.0%f.s. Hysteresis...<0.5%F.S. Supply air dependency....<0.3%/0.1bar(1.5psi) Temperatureeffect...<0.5%/10K Air consumption supply air pressure air consumption single acting 1.4bar(20psig)...200l n /h ( 7.1 scfh) 3.0bar(45psig)...350l n /h (12.4 scfh) 6.0bar(90psig)...600l n /h (21.2 scfh) double acting 1.4bar(20psig)...300l n /h (10.6 scfh) 3.0bar(45psig)...500l n /h (17.7 scfh) 6.0bar(90psig)...950l n /h (33.5 scfh) Air output Load effect 2)... 3%fordelivery flow 2 350 l n /h (83 scfh)...+3%forexhaustedflow 1 900 l n /h (67 scfh) Capacity at max. deviation supply air pressure air output capacity 1.4bar(20psig)...2700l n /h ( 95 scfh) 2.0bar(30psig)...3500l n /h (124 scfh) 4.0bar(60psig)...5500l n /h (194 scfh) 6.0bar(90psig)...7500l n /h (265 scfh) Materials Base plate, manifold, I/P-housing, rotationadapter...aluminum(alloyno.230) finished with DD-varnish Color gray or blue Cover...impactresistantpolyester Color blue All moving parts of feedback system...1.05 / 1.4571 Mountingbracket...1.01 Weight single acting without gauges...approx.1.5kg(3.3lbs) withgauges...approx.1.7kg(3.7lbs) double acting...approx.1.7kg(3.7lbs) attachment kit for diaphragm actuators.. approx. 0.3 kg (0.6 lbs) forrotaryactuators...approx.0.5kg(1.1lbs) Data measured according to VDI/VDE 2177 1) Data based on following parameters: stroke 30 mm (1.28 in), range spring FES 628/1, feedback lever effective length 117.5 mm (4.63 in), max. amplification, supply air pressure 3 bar (45 psig) 2) measured at air supply 1.4 bar (20 psig) and 50 % of signal range

PSS EVE0103 A-(en) SRI983 3 Connection Pneumatic...Femalethreads Q 1/4-18 NPT acc. to DIN 45 141 Electric Line entry Explosion protection acc.toatexeexd...femalethreadm20x1.5 acc.tofmandcsa...femalethreadq1/2-14npt Note the section Safety requirements Terminals...Screw terminals Mounting Typeofmounting...forattachingto diaphragm actuators acc. IEC 534-6 (NAMUR)...forattachingto rotary actuators Mounting orientation....any Gauges Indicating range InternalI/P-output...0...1.6bar(0...23psig) Output...0...10bar (0...150psig) Error limit...class1.6 SAFETY REQUIREMENTS Safety...safetyclassIII as per DIN EN 61010-1 (DIN IEC 61010-1) (VDE 0411 part 1) overvoltagecategory...1 internalfuses...none externalfuses...limitationofpower supplies for fire protection has to be observed due to EN 61010-1 9.3. ff. 1) 2) Electrical Classification Type of protection flameproof, ATEX Typeofprotection...II2GExdIIB+H2T6 Certificateofconformity...FM14ATEX0022X Ta=-40 C to +75 C Type of protection Intrinsically Safe, ATEX Typeofprotection...II1GExiaIICT4 Certificateofconformity...FM14ATEX0022X Ta=-55 C to +85 C Type of protection dust, ATEX Typeofprotection...II2DExtDA21IP65T85 C Certificateofconformity...FM14ATEX0022X Ta=-40 C to +75 C Type of protection non incendive, ATEX Typeofprotection...II3GExnAnLIICT6 Certificateofconformity...FM14ATEX0023X Ta=-55 C to +85 C Typeofprotection...II3GExnLIICT4 Certificateofconformity...FM14ATEX0023X Ta=-55 C to +85 C In the case of operation of the positioner in explosion hazardous areas with an ambient temperature of more than 60 C, it must be ensured that the connecting cable and cable entry meet the increased thermal demands (max. ambient temperature plus 10 K). Electrical connection with cable and wiring entry glands in accordance with special certification to explosion proof classification EN 50 018, using suitable cable and wiring or with conduit in accordance with special certification to explosionproof classification EN 50 018. A spark barrier sealing compound must be applied directly at the point of entry. See Certificate of Conformity EX EVE0103A-(de)(en) Explosion protection according to FM IS/I,II,III/1/ABCDEFG/T4 I/0/AExiaIIC/T4 NI/I/2/ABCD/T4 S / II, III / 2 / EFG T4 XP/I/1/BCD/T6 DIP/II,III/1/EFG/T6 I / 1 / AEx d IIB+H2 / T6 II,III / 1 / AEx td / 21 / T85 C Type 4X, IP65 Explosion protection according to CSA IS/I,II,III/1/ABCDEFG/T4 I/0/ExiaIIC/T4 NI/I/2/ABCD/T4 S / II, III / 2 / EFG T4 XP/I/1/BCD/T6 DIP/II,III/1/EFG/T6 I/1/ExdIIB+H2/T6 Type 4X, IP65 1) With appropriate order only 2) National requirements have to be observed

4 SRI983 PSS EVE0103 A-(en) MODEL CODES SRI983 Electro-pneumatic Positioner SRI983 170715 Version Single Acting................................ -B Double Acting................................ -C Input Signal Range 4-20 ma............................... -I Mode of Action Increasing Input Increases Output............................. D Increasing Input Decreases Output............................. R Gauges Without Gauges.......................................... L Two Built-In Gauges (bar/psi)............. (a).................... M Electrical Certification II2GExdIIB+H2T6-II2DExtDA21IP65T85 C........................... EDZ II1GExiaIICT4-II2DExtDA21IP65T85 C............................. E1Z II3GExnAnLIICT6-II3GExnLIICT4................................ E3Z FM Approved For IS/I,II,III/1/ABCDEFG/T4;I/0/AExiaIIC/T4;NI/I/2/ABCD/T4; S/II,III/2/EFGT4;XP/I/1/BCD/T6;DIP/II,III/1/EFG/T6; I / 1 / AEx d IIB+H2 / T6; II,III / 1 / AEx td / 21 / T85 C; Type 4X, IP65................. FDZ CSA Approved For IS/I,II,III/1/ABCDEFG/T4;I/0/ExiaIIC/T4;NI/I/2/ABCD/T4; S/II,III/2/EFGT4;XP/I/1/BCD/T6;DIP/II,III/1/EFG/T6; I/1/ExdIIB+H2/T6; Type4X,IP65................................ CDZ Intrinsically safe and explosion proof................. (d)................ BRZ EAC Approved For Explosion Proof and Intrinsically Safe...... (d)................ EAC Pneumatic Connection Rear Facing NPT 1/4, Prepared For Linear Actuators............................. N Down Facing NPT 1/4, Prepared For Rotary Actuators.............................. Q Options Certificate EN 10204-2.1 - Certificate of compliance with the order........................... -1 New Generation SRI983....................... (b)....................... -N Tag No. Labeling Stamped With Weather Resistant Color........................................ -G Stainless Steel Label Fixed With Wire......................................... -L Example Model Code: SRI983 -B I D L EDZ N -NL (a) Only available with Version -B (b) ALWAYS (mandatory) (d) Not released

PSS EVE0103 A-(en) SRI983 5 MODEL CODES Accessories Attachment Kit EBZG For diaphragm actuators with casting yoke acc. NAMUR. (incl. standard Couple Lever) (for SRP981, SRI983,...)... -GN For diaphragm actuators with pillar yoke acc. NAMUR. (incl. standard Couple lever) (for SRP981, SRI983,...)..... -FN For rotary actuators, without flange, 3 drill holes 6.5 mm (for SRP981, SRI983, SRI986, SMP981, SMI983, SGE985). -PN For rotary actuators, without flange, 4 threads M6 (e.g for Petras actuators) (for SRP981, SRI983, SRI986,...)..... -NN For rotary actuators, with flange (for SRP981, SRI983, SRI986, SMP981, SMI983, SGE985)............. -JN For rotary actuators acc. to VDI/VDE 3845, with shaft (for SRP981, SRI983, SRI986, SMP981, SMI983, SGE985)... -ZN For Masoneilan type Camflex II (for SRP981, SRI983, SRI986, SMP981, SMI983, SGE985).............. -RN For Masoneilan type Sigma F (for SRI986, SRP981, SRI983)............................. -SN For Honeywell Air-O-Motor Type 05 (for SRI986, SRP981, SRI983).......................... -SA For Masoneilan type 37/38, Fisher Elliott type 656, 667 (for SRP981, SRI983,SGE985,SMI983,SMP981)...... -TN For Guide type P (for SRP981, SRI983)........................................ -UN For Masoneilan type 87/88 (for SRP981, SRI983, SMP981, SMI983, SGE985).................... -EN For Masoneilan VariPak (for SRP981, SRI983, SGE985, SMI983, SMP981)...................... -MN For IAL actuators (for SRP981, SRI983, SGE985, SMI983, SMP981)......................... -VN Brackets VDI/VDE 3845 (A = 130 mm/5.12 in; B = 50 mm/1.97 in) (for SRP981, SRI983, SRI986,SGE985,...)....... -C3 Brackets VDI/VDE 3845 (A = 80 mm/3.15 in; B = 30 mm/1.18 in) (for SRP981, SRI983, SRI986, SGE985,...)...... -C2 Brackets VDI/VDE 3845 (A = 80 mm/3.15 in; B = 20 mm/0.79 in) (for SRP981, SRI983, SRI986, SGE985,...)....... -C1 Couple Lever / Cam EBZG Standard (a = 72 mm) (for SRP981, SRI983, SRI986, SMP981, SMI983, SGE985).................. -AN Extended (a = 91 mm) (for SRP981, SRI983, SRI986, SMP981, SMI983, SGE985).................. -BN Inverse equal percentage cam for rotary actuators (for SRP981, SRI983, SRI986)................... -CN Spring Set FESG Range-Springs (4 pc.) (for SRP981, SRI983,SRI986)................................. -FN

6 SRI983 PSS EVE0103 A-(en) ATTACHMENT KIT FOR DIAPHRAGM ACTUATORS Attachment to casting yoke according to IEC 534-6 (NAMUR) Code EBZG-GN 20 M8 17 Attachment to pillar yoke according to IEC 534-6 (NAMUR) Code EBZG-FN 20 17 20... 35.79... 1.38 71 2.80 182 7.17 54 2.13 71 2.80 176 6.93 2,5.10 49,5 1.95 6.24 83 3.27 72 2.83 14.55 +0,2 +.01 7,9.31 91 3.58 10.39 20.78 9.35 96 3.78 8 4.31.16 mm in 9.35 30 9.35 65 2.56 10.39 21.83 21 54 2.13 9 9 Feedback lever Code EBZG-AN, -FN, -GN Code EBZG-BN (extended version) 9 14 15 M6 Mounting bracket according to IEC 534-6 (NAMUR) for Code EBZG-GN, FN 7,8-0,05.31 -.002 20 Corrier bolt for attachment to valve stem 116 4.57 71 2.80 6,5.26 11. 52 2.05 16 8.31 72 2.83 80 3.15

PSS EVE0103 A-(en) SRI983 7 ATTACHMENT KIT FOR ROTARY ACTUATORS With shaft (according to VDI/VDE 3845) Code EBZG-ZN Housing dimensions Attachment kit with shaft Code EBZG-ZN resp. without flange Code EBZG-NN 1,5 5.65 50 1.97 95 3.74 M6 Detail Z 4,5.18 14.55 28+0,5 1.10+.02 30 1.18 12.47 16H8.63 64 2.52 99 3.90 4.16 13,5.53 8.31 6.53 167 6.57 Without flange Code EBZG-NN, -PN 1,5 5.65 Housing dimensions Attachment kit without flange Code EBZG-PN 95 3.74 Detail Y 11. 30 1.18 6,5 /.26 14-6.55 -.24 45 0,2 1.77.01 64 2.52 15 0,2.59.01 70 2.76 5.20 12.47 183,5 7.22 22.87 99 3.90 1,2.05 12.47 16.63 M6 14... 15,5.55....61 Adaption of the actuator drive shaft end and correct axial location by client! 167 6.57 With flange Code EBZG-JN 75 2.95 60 2.36 0,2.01 0,2.01 10.39 12.47 mm in 3.12 54 2.13 47 1.85 86 3.39 6.24 10.39 63 2.48 50 1.97 6,5.26 Rotation angle max 120 ; torque requirement 14 Nm

8 SRI983 PSS EVE0103 A-(en) DIMENSIONS, CONNECTIONS 8,8.35 113,5 4.47 58 (93*) 2.28 (3.66*) mm in 105 4.13 62,5 2.46 17.67 182 7.17 17.67 100 3.94 72 2.83 47,5 1.87 4 74,5 2.93 106,5 140 4.19 5.51 5 1 6 7 8 9 11. Front view * Code L Code M, N 10 11 1 Electrical connection, line entry 2 Screw terminals (+/ ) for signal input 3 Earth connection 2 4 Rear facing pneumatic connections (when using linear actuators) 5 Angled pneumatic connections (when using rotary actuators) 6 Output II (only on double-acting valve positioners) 7 Supply air 8 Output I 9 Feedback lever 1 10 Gauge for internal I/P-output (w) 11 Gauge for output (y) 3 * I/P converter cover removed Subject to alterations - reprinting, copying and translation prohibited. Products and publications are normally quoted here without reference to existing patents, registered utility models or trademarks. The lack of any such reference does not justify the assumption that a product or symbol is free. FOXBORO ECKARDT GmbH ECKARDT S.A.S. DOKT 535 783 028 Pragstr. 82 20 rue de la Marne D-70376 Stuttgart F-68360 Soultz Germany France Tel. +49 (0)711 502-0 Tel. + 33 (0)3 89 62 15 30 Fax +49 (0)711 502-597 Fax + 33 (0)3 89 62 14 85 http://www.foxboro-eckardt.com