American Standard. Selectronic Remote Control Operating Manual M965370

Similar documents
Touch Screen Guide. OG-1500 and OG Part # T011

These variables can be accessed by holding the UP button for 5 seconds.

User Manual. Heads-Up Display (HUD) DiveCAN. Mechanical Button Version

Race Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock

Altimeter and Compass Watch Instruction Manual

DT 630 ALTIMETER, BAROMETER AND COMPASS WATCH OPERATING INSTRUSTIONS

CONSOLE-320 ENGLISH. 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output

Quick Guide. SGX-CA500 Cycle Computer SGY-PM Series Power Meters

Laboratory Safety Guideline Emergency Eyewash and Safety Showers

GNX 20/21. Owner s Manual

Endo-Flush Order # ZUTR30004 OPERATION MANUAL. Zutron Medical, LLC W 98 th St #40-27 Lenexa, KS Phone Fax

Water Temperature Control - Groups of Fixtures

WELCOME TO THE REVOLUTION

KIV-SACS Safe automatic calibration system:

ACV-10 Automatic Control Valve

MP-70/50 Series Scoreboard Controller User Guide

ALGE Water Polo Scoreboard

Push Button Minute Timer Programmable between 1 minute and 30 minutes with built in multi-way control

DANAGE TIMER System Controller User Manual

Instruction Manual Dräger MSI P7 and MSI P7 plus

MP-70/50 Series Scoreboard Controller User Guide

Operating instructions Electrical switching facility pco

AIR SAVING PRODUCTS ADDING VALUE AIR-SAVER LOCATOR LOCATOR-EV

Hydro-Control V User Guide

MP15 Jockey Pump Controller

Device overview. 6 Breathing circuit connection. Note: When the remote control foot pedal is connected, the manual switch is disabled.

Operating Manual. SUPREMA Calibration. Software for Fire and Gas Warning Units. Order No.: /01. MSAsafety.com

GNX 20/21. Owner s Manual

ELIMINATOR COMPETITION DRAG RACE Program Manual Firm Ver 4.11

CONTROL LOGIC DESCRIPTION DOCUMENT IC-410ND

Kit Details Air Lift Performance HARDWARE LIST STOP!

User Manual 1 P a g e Rev. V1.6-EN 11/08/2014

ES 2070 SV. Electronic controller for water softening units. Instruction Manual. Software version 1.00

AIR-SAVER G1 AIR-SAVER G2 LOCATOR-EV COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS AIR SAVING PRODUCTS

BT 2000 range Score / Club / Classic / Alpha

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

OPERATOR s MANUAL AHCON PCI 3000

BUBBLER CONTROL SYSTEM

Version-E Manual

Autotrol Performa ProSoft

AIR-SAVER G1 AIR-SAVER G2 LOCATOR LOCATOR-EV COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS AIR SAVING PRODUCTS

Shearwater GF Computer

DDR Dive Data Recorder Manual - Rel /12

DG100 Digital Depth Gauge and Timer. Training Module, Rev B

CCT-7320/ROC-2313 Reverse Osmosis Controller

Technology. In the My Files [My Files] submenu you can store all the programs that you have made on the NXT or downloaded from your computer.

Dosing & Granudos. Controllers. Chemical Storage. Chemical. Dosing &

BUBBLER CONTROL SYSTEM

APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM CHART A 1.2 FRICTION LOSSES FOR DISK-TYPE WATER METERS 1-1/2"

1. Functional description. Application program usage. 1.1 General. 1.2 Behavior on bus voltage loss and bus voltage. 1.

APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEMS CHART A-1 FRICTION LOSSES FOR DISK-TYPE WATER METERS 1-1/2"

DeeterFlow Automatic Liquid Dispenser

OMNISPORT 2000 SWIMMING QUICK REFERENCE

USER MANUAL. Intelligent Diagnostic Controller IDC24-A IDC24-AF IDC24-AFL IDC24-F IDP24-A * IDP24-AF * IDP24-AFL * IDP24-F * 1/73

UsER manual for Watersens ph -REDOX

appendix a recommended rules For sizing the water supply system PRE-PRINT Chart a 1.2 FriCtion losses For Disk-type water Meters

ECHO MANUAL WARNING. L B A ltim e te rs. ECHO is a trademark of LB Altimeters, Denmark

2/2/2018 Control System General Description(H4DOTC) Diagnostic Trouble Code (DTC) Detecting Criteria DTC P0442 Evaporative Emission Control

LED CONVERSION BOARD - YAKUZA SERIES EGO/GEO

Aladin ONE (Matrix) User Manual

HyperSecureLink V6.0x User Guide

Series 7250 Ruska High-Speed Digital Pressure Controller. GE Sensing. Features

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Vapor Sorption Analyzer

User s manual VCI07. For variable speed compressors ed00. Applicable as of Version 12. Bar PSI C F

KEM Scientific, Inc. Instruments for Science from Scientists

Commercial Softeners. Installation, Operation & Maintenance Guide. Manual 002.1

FLUSHMATE FLUSHOMETER - TANK SYSTEM. 501-A Series. Owner s Service Manual. 501-A Series

RAM 4021 Operation Manual

PTG100 Precision Test Gauge

MONSOON 6V Pump Control System

Garmin Swim Owner s Manual

Monsoon3V+ Multiple Pump VFD Control System. Please pass these instructions on to the operator of this equipment.

The ultimate in water softening

INSTRUCTION MANUAL PS4 SPS-X3 VER 2.0

GNX 20/21 Owner s Manual

PERFORM Operating Document

Technology. In the My Files [My Files] submenu you can store all the programs that you have made on the NXT or downloaded from your computer.

6200 Isoperibol Calorimeter Model Number: 6200

MAGNETIC CYCLING TRAINER SF-B0419 USER MANUAL

Optical Dissolved Oxygen Meter

X-dock Software History

Datasheet: K-30 ASCII Sensor

Iron Filter Installation / Operation Manual

D OPERATION and MAINTENANCE MANUAL MILITARY ALTIMASTER MA-10 (30,000 foot COMPRESSED SCALE: FP-02093) January 3, 2008 REV 12

Control & Maintenance. INT69 Diagnose INT69 TM Diagnose. Protect the heart of your system

Operating the DataMaster cdm VERSION 1.2

GNX 120/130. Owner s Manual

PART 5 - OPTIONS CONTENTS 5.1 SYSTEM EXPANSION 5-3

Pneumatic high-pressure controller Model CPC7000

SERVICE INSTRUCTIONS

Duplex Commercial Softeners

Scoreboard Operator s Instructions MPC Control

G100 RANGE G100, G110, AND G150 OPERATING MANUAL

INSTRUCTION MANUAL. Automatic Water Softener System. Model: PSE-08. Xsential Water Filtration Systems

Optical Dissolved Oxygen Meter

PERFORM Operating Document

COMPRESSED AIR SAVING PRODUCTS INDEX. Useful information AIR-SAVER G1 AIR-SAVER G2 LOCATOR. Condensate Management Specialist

OPERATING INSTRUCTIONS FOR

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

Transcription:

American Standard Selectronic Remote Control Operating Manual M9670

Transmission Area DISPLAY OPERATION: The remote programmer has 4 keys: Enter or validate Cancel Scroll UP Scroll Down Mini-USB Port The Down Key is also used to turn ON the remote programmer. After not being used for minutes, the programmer automatically turns itself off.

Setting The Detection Distance *** ONLY DONE AFTER SELECTING ALL THE MODE SETTINGS *** When using the programmer, the sensor will begin blinking for approximately seconds after the enter key is pressed and the display shows TRANSMISSION OK. While it is blinking move your finger to within 1 inch of the sensor (nearly covering it). When the light stops blinking and stays on steady, remove your finger and, with the palm of your hand facing the sensor, move your hand to the distance to be set. When the sensor starts to blink again, move you hand away from the detection area. The flashing will stop and the sensor will now be programmed with the new setting. The Programmer will now display BACKUP FUNCTION. You can program the next sensor(s) by pointing the programmer at the sensor and pressing the enter key. The programmer will remember the programmed settings for approximately. minutes before turning off. NOTE: See Product Settings & Specifications Chart

Start ON MENU 1 CLEANING MENU DISINFECTION MENU DIAGNOSTIC To MENU 4 Press to turn on the programmer Press to activate the menus Press to go to MENU Press to go to MENU Press to go to MENU 4 DISINFECTION DURATION :114min time and press to transmit the signal to sensor to activate the DISINFECTION cycle for the selected period of time and press to transmit the signal to sensor to activate the DIAGNOSTIC feature. NOTE: Use the up and down arrow keys to scroll through the current settings Cleaning Disinfection Diagnostics TIP: Cleaning Use this mode to disable the sensor for 1 minute. This is sometimes used by the cleaning crew to keep the faucet off while cleaning the fitting and or fixture. TIP: Disinfection This is typically used in healthcare facilities that conduct periodic high temperature or high anti-bacterial chemical purging of the water lines. The maintenance person should activate this mode and stay present to avoid any users from exposure to the purged water. This mode can be activated while in any function (hand-wash faucet, urinal flush valve, etc.). The duration (run time) can be programmed from 1 minute to 10 minutes in 1 minute intervals. TIP: Diagnostics Use this mode to determine the settings of the faucet or flush valve. NOTE: this feature will only work with products made 008 or newer. 4

From MENU MENU 4 PARAMETER SENSOR 008 VERSION Parameter Language Backlight MENU LANGUAGE NOTE: Not all features available with this version SENSOR 00 VERSION MENU.1 Francais TIP: Sensor Version Select 008 for all Selectronic products manufactured from 008 to present day. Select 00 for products manufactured from 00 through 007. **If unsure, use the 008 setting. If repeated transmission errors occur, then try the 00 setting. MENU 6 BACKLIGHT BACKLIGHT Press up or down to select language French, English, Spanish, Italian, or German Press to set selected language Press up or down to select display backlight intensity Press to set selected display intensity for easy reading in different lighting conditions. From this menu, scroll down to the specific mode you want to program: Hand-Wash Metering On/OFF Urinal LF Urinal + PF **(NOT USED)** Flushometer Kitchen **(NOT USED)** DB Toilet

From MENU 4 MENU 4.1 HAND-WASHER NOTE: This is the standard instant on / instant off faucet mode. Press to set COMF. TIMEOUT = 1 Sec Hand-Wash -- Faucet Setting the sensor to the Hand-Wash faucet mode: - Set the "Comfort Timeout" - Set the "Safety Timeout" - Set "Auto-Rinse" frequency (if the frequency is set to 0, auto-rinsing (auto-purging) is Off) - Set the "Duration" (run time) of the auto-rinsing process. time SAFETY Timeout = s time TIP: The COMF. TIMEOUT (Comfort Timeout) determines how long the water will run after the users' hands are removed from the detection zone. This prevents the water from quickly turning On & Off as the user s hands move in & out of the detection zone. Recommended setting: 1. sec Adjustable from 0 to 10 sec in 0. sec increments = OFF Press up or down to turn ON the Auto Rise feature and adjust frequency TIP: The SAFETY Timeout is sometimes referred to as the Vandal Timer. This should be set ON to prevent someone from intentionally blocking the eye (chewing gum, tape, etc) to keep the faucet running and have the sink overflow. Default Setting: sec Adjustable from to 10 sec in sec increments To MENU 4. = s time the Auto Rinse ON, to the sensor TIP: The (Auto Purge) allows the faucet to automatically turn ON after a set time period of non use, maintaining the trap seal & preventing the water from becoming stagnant Default Setting: OFF This time period can be set to activate from 1 to 7 hrs (of non-use) in 1 hr increments. The duration of run time can be set from 1 sec. to 40 sec. 6

Metering -- Faucet From MENU 4.1 Setting the sensor to the Metering faucet mode: - Set the "Comfort Timeout" (run time) - Set "Auto-Rinse" frequency (if the frequency is set to 0, auto-rinsing (auto-purging) is Off) - Set the "Duration" (run time) of the auto-rinsing process. MENU 4. METERING COMF. TIMEOUT = 1 Sec (RUN TIME) metering run time TIP: In this Metering Mode, the COMF. TIMEOUT (Comfort Timeout) is the RUN TIME - how long the water will run once activated by the user. Run Times: 1,,., 7., 10, 1, 0, 60, or 10 seconds = OFF the Auto Rinse OFF, to the sensor Press up or down to turn ON the Auto Rise feature and adjust frequency To MENU 4. = 1 s time the Auto Rinse ON, to the sensor TIP: The (Auto Purge) allows the faucet to automatically turn ON after a set time period of non use, maintaining the trap seal & preventing the water from becoming stagnant Default Setting: OFF This time period can be set to activate from 1 to 7 hrs (of non-use) in 1 hr increments. The duration of run time can be set from 1 sec. to 40 sec. 7

NOTE: This is actually uses the Metering mode, but with the added feature of being able to start and stop the water flow before the metering time runs out. From MENU 4. Metering with On/Off -- Faucet Setting the sensor to the Metering faucet mode: - Set the "Comfort Timeout" (run time) - Set "Auto-Rinse" frequency (if the frequency is set to 0, auto-rinsing (auto-purging) is Off) - Set the "Duration" (run time) of the auto-rinsing process. MENU 4. ON/OFF COMF. TIMEOUT = 1 Sec metering run time TIP: In this "Metering with On/Off Mode, the COMF. TIMEOUT is the RUN TIME - how long the water will run once activated by the user. The detection distance is set very short, so the user must start & stop the water by moving hands close to the sensor. - This is suited for gooseneck type fittings where the movement of the user may be outside the normal detection zone. Run Times : 1,,., 7., 10, 1, 0, 60, or 10 seconds = OFF the Auto Rinse OFF, to the sensor Press up or down to turn ON the Auto Rise feature and adjust frequency To MENU 4.4 = 1 s time the Auto Rinse ON, to the sensor TIP: The (Auto Purge) allows the faucet to automatically turn ON after a set time period of non use, maintaining the trap seal & preventing the water from becoming stagnant Default Setting: OFF This time period can be set to activate from 1 to 7 hrs (of non-use) in 1 hr increments. The duration of run time can be set from 1 sec. to 40 sec. 8

Urinal -- Urinal Flush Valve From MENU 4. MENU 4.4 URINAL DETEC. INTERVAL = Sec the required user detection activation time TIP: The "DETEC. INTERVAL" (Detection Interval) is how long a user must be in the detection zone to arm the flush valve. This eliminates false flushing due to people walking past the urinals. Recommended setting is sec. TIP: The "RINSE START INT." (Rinse Start Interval) is how long after the user leaves the detection zone before the valve will flush. Recommended setting is sec. RINSE START INT = = 4 h Scroll down to turn the Auto Rinse feature OFF = OFF RINSE = s how long to wait after the user leaves to begin the flush Press up or down to adjust Flush Time = 7 h = s Press up or down to adjust the frequency Align the programmer with the sensor and press to transmit the program, with the Auto Rinse OFF, to the sensor TIP: The "'" (Sanitary Flush) allows the flush valve to automatically flush, after a set time period of non-use, to maintain the trap seal. This time period can be set to activate from OFF to 7 hrs (of non-use) in 1 hr increments. You can set the duration of flush time from 1 sec. to 40 sec. never more than the fixture can drain before overflowing! (Recommended setting is OFF unless prolonged non-use is expected then s should maintain the trap seal). Default Setting: Off TIP: The "Rinse'" is the Flush Time (Flush Duration). See Flush Valve Settings Chart the Auto Rinse run time the Auto Rinse ON, to the sensor To MENU 4. 9

From MENU 4.4 Flushometer Toilet Flush Valve MENU 4. LF URINAL + PF NOT USED TIP: The "DETEC. INTERVAL" (Detection Interval) is how long a user must be in the detection zone to arm the flush valve. This eliminates false flushing due to people walking past the urinals. Recommended setting is sec. MENU 4.6 FLUSHOMETER DETEC. INTERVAL = Sec TIP: The "RINSE START INT." (Rinse Start Interval) is how long after the user leaves the detection zone before the valve will flush. Recommended setting is sec. the user detection activation time RINSE START INT = 7 = OFF the Auto Rinse OFF, to the sensor how long to wait after the user leaves to begin the flush Press up or down to turn ON the Auto Rise feature and adjust frequency MENU 4.7 KITCHEN NOT USED RINSE = 7 s Press up or down to adjust Flush Time = 7 h = s TIP: The "'" (Sanitary Flush) allows the flush valve to automatically flush, after a set time period of non-use, to maintain the trap seal. This time period can be set to activate from OFF to 7 hrs (of non-use) in 1 hr increments. You can set the duration of flush time from 1 sec. to 40 sec. never more than the fixture can drain before overflowing! (Recommended setting is OFF unless prolonged non-use is expected then s should maintain the trap seal). Default Setting: Off To MENU 4.7 TIP: The "Rinse" is the Flush Time (Flush Duration). See Flush Valve Settings Chart the Auto Rinse run time the Auto Rinse ON, to the sensor 10

From MENU 4.4 MENU 4.8 DB Toilet SHORT RINSING = 1. Sec DETEC. INTERVAL = Sec the user detection activation time Dual Flush Toilet Flush Valve TIP: The "Short Rinsing" is the is the flush time used when the user stays in the detection zone for less than 1 minute. This should be the setting for the lowest of the flush volumes listed for this model flush valve. See Flush Valve Settings Chart TIP: The "DETEC. INTERVAL" (Detection Interval) is how long a user must be in the detection zone to arm the flush valve. This eliminates false flushing due to people walking past the urinals. Recommended setting is sec. TIP: The "RINSE START INT." (Rinse Start Interval) is how long after the user leaves the detection zone before the valve will flush. Recommended setting is sec. RINSE START INT = 7 = OFF the Auto Rinse OFF, to the sensor how long to wait after the user leaves to begin the flush Press up or down to turn ON the Auto Rise feature and adjust frequency RINSE = 7 s Press up or down to adjust Flush Time = 7 h = s TIP: The "" (Sanitary Flush) allows the flush valve to automatically flush, after a set time period of non-use, to maintain the trap seal. This time period can be set to activate from OFF to 7 hrs (of non-use) in 1 hr increments. You can set the duration of flush time from 1 sec. to 40 sec. never more than the fixture can drain before overflowing! (Recommended setting is OFF unless prolonged non-use is expected then s should maintain the trap seal). Default Setting: Off TIP: The "Rinse" is the Long Flush Time (Flush Duration) if the user stays in the detection zone for longer than 1 minute. See the Flush Valve Settings Chart the Auto Rinse run time the Auto Rinse ON, to the sensor 11

Flush Valve Settings URINAL FLUSH VALVE SETTINGS Model (GPF) Detect Interval Rinse Start (Flush Start) Rinse (Flush- Duration) Auto Rinse (Sanitary Flush) Auto Rinse (Run Time) Innsbrook 8 OFF or 7h 1.0 6 OFF or 7h 0. OFF or 7h 1 0. 1. OFF or 7h 1 0.1 1 OFF or 7h 1 TOILET FLUSH VALVE SETTINGS Model (GPF) Detect Interval Rinse Start (Flush Start) Rinse (Flush- Duration) Auto Rinse (Sanitary Flush) Auto Rinse (Run Time) 1.6. OFF or 7h 1.8 OFF or 7h 1.1. OFF or 7h DUAL-FLUSH VALVE SETTINGS Model (GPF) Short Rinsing (Short Flush) Detect Interval Rinse Start (Flush Start) Rinse (Flush- Duration) Auto Rinse (Sanitary Flush) Auto Rinse (Run Time) 1.6 / 1.8.0. OFF or 7h 1.8 / 1.1.. OFF or 7h 1