Recirculating Coolers

Similar documents
Customer Responsibilities

Pneumatic high-pressure controller Model CPC7000

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Additel 761 Automated Pressure Calibrators Selection Guide

FAST EVAPORATION AT NORMAL PRESSURE

Additel 761 Automated Pressure Calibrators

Additel 761 Automated Pressure Calibrators Selection Guide

Pneumatic high-pressure controller Model CPC7000

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

SonoMeter 30 Energy Meters

HumiSys HF High Flow RH Generator

The affordable consumption counter for compressed air and gases R 3 /4 (DN 20)

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

6200 Automatic Isoperibol Calorimeter Calorimeter with 1108 Oxygen Bomb, Bucket and 1757 Printer

Pressure Calibrators. Series PC..., PM...

T h e h a n d y L A U D A B u b b l e P r e s s u r e Te n s i o m e t e r M P T C a l s o r e c o r d s f a s t s u r f a c t a n t s i n m i l l i

PHOENIX L300i Best-in-class Helium Leak Detectors

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

F&J SPECIALTY PRODUCTS The nucleus of quality air monitoring programs

Air Amplifiers & SYSTEMS

Additel 761 Automated Pressure Calibrators

Workshop Compressors CLASSIC Series

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

Pneumatic spool valve islands

SPIROVENT VACUUM DEGASSERS

Vacuum. Dry Turbo Pumping Stations. Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators. Hermetically Sealed Pumps for He3 Recirculation

Multi Fibres. MiniFant M99 insulation blowing MacHinE

OMNISTAR / THERMOSTAR. The efficient solution for gas analysis. Intelligent software. Wide range of applications.

Measurement of Low GAS & Liquid Flows

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

AUTOMATIC HOSE TEST UNIT, TYPE SPU

6200 Isoperibol Calorimeter Model Number: 6200

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

Oxygen Measurement Systems High Reliability and Wide Application Coverage

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Basic & Controlled Atmosphere Glove Boxes

M95 insulation blowing machine Reliability and power in a compact design.

Oxidation Stability of Gasoline and Aviation Fuels

Additel 761 Automated Pressure Calibrators

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

Easy with a modular concept for future expansion

V5001P. Kombi-Auto Differential Pressure Control Valve. Product specification sheet

Customer Responsibilities

Series Environmental Chambers

CO2 incubator with additional process controls

C-Flow Coriolis Mass Flow Meters

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

2-step solenoid valve Type ICLX

Hand-held pressure calibrator with integrated pump Model CPH6600

ADT 761 Automated Pressure Calibrator

Expert Hydrostatic Level Transmitters

NEW: CO2 incubator with sterilizable sensor

High-performance submersible pressure transmitter For level measurement Model LH-10

Customer Responsibilities

Precision pressure sensor Basic version Model CPT6020

WaterSource Heat Pump Hose Kit Performance Specification-Summary

3.0 Pressure Transmitter Selection

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP100 ph/redox (ORP) cartridge sensors with water-wash option

Customer Responsibilities

Design Features. General Description

THE NEW SP SERIES MAXIMUM CAPACITY MINIMUM FOOTPRINT

ila ACTIVVE SYSTEM PLATFORM

Pneumatic service kit Model CPG-KITP

2-step solenoid valve Type ICLX

Multiple Pressure Booster Systems With Variable Speed Controller Type BL

Liquid Level Controllers

Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

NEW: CO2 incubator with sterilizable sensor

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

BIMBAR INFLATABLE PACKERS AND ACCESSORIES

red-y compact series product information Battery Powered Thermal Mass Flow Meters for Gases

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?

Compact Transfer Pump

Cryostream 800 Series

TF- & DM-Series. Turbineflowmeter

Infrared Linescanners

CI-SfB 732 (5-1) x. - laboratory fittings

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

Workshop Compressors CLASSIC Series

EPP4 Pressure Regulator Basic G 1/4"

World Area Differences Technical Information

High precision dispensing valve that is an uncompromising response to the need for sophisticated dispensing equipment

Water valve Type WVO. Data sheet MAKING MODERN LIVING POSSIBLE

DELTI. Vac. DELTI-Vac MIL. Application. Principle. Characteristic

cooled, Heated ATH 2800 MT, DN 250 ISO-F, External drive electronics, Water cooled, Heated

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

High-performance submersible pressure transmitter For level measurement Model LH-10

VACUUM REGULATORS CONTENTS

GAS INJECTION TECHNOLOGY GIT

Energy Management solutions for compressed air and industrial gases. vpinstruments.com

AES 28/50/75/110/150 RFG Sterilization Autoclaves with counter pressure and fast cooling

Tank Blanketing Pressure Regulators RHPS Series

780S Ultra High Purity Series

Constant and Particle Free Point-of-Use Water Pressure

Transcription:

(Chillers) - Basic type Low Temp. - General Type Low Temp. - Intelligent type Selection Guide Recirculating Cooler Basic type General type (Low temp.) Intelligent type (Low temp.) Working Temp. Range ( / ) Cooling capacity at 10 [Kw] HX-20 1.4 HX-25 1.7 HX-20H 1.4 +3 to 40 HX-25 H 1.7 / +37.4 to 104 HX-35H 3.1 HX-45H 3.6 HX-55H 5.1 HL-05 0.50 HL-10 0.60 HL-15 1.15 HL-20 1.50 HL-15H -20 to 40 1.15 HL-20H / -4 to 104 1.15 HL-25H 1.80 HL-35H 2.30 HL-45H 4.50 HL-55H 6.00 HS-15 1.15 HS-20 1.50 HS-25 1.80 HS-35 2.30 HS-45-20 to 40 4.50 HS-55 / -4 to 104 6.00 HS-25H 1.80 HS-35H 2.30 HS-45H 4.50 HS-55H 6.00 Max. flow rate (L / min, gal / min) Pump (50Hz) Max. pressure (bar / psi) 38 / 10.03 1.58 / 22.92 45 / 11.89 4.3 / 62.37 50 / 13.2 1.0 / 14.5 40 / 10.57 2.8 / 40.6 70 / 18.49 6 / 87.0 40 / 10.57 2.8 / 40.6 70 / 18.49 6 / 87.0 Page 72 74 76 Accessories & Options Page for Recirculating Cooler 78-79

General Applications General Applications HX-Series HL/HS-Series AAS Autoclaves Calorimeters CCM cameras Combinatorial chemistry Cooling of peltier elements Diffusion pumps Distillation apparatus Dosing and gluing techniques Drying of gas Electrophoresis chambers Gas chromatographs General industries General laboratory apparatus Lasers Mass spectrometers Mills and kneaders NMR Pilot plants Plastic industries Reaction vessels Rotary evaporators SEM Semiconductor industries Soxhlet installation Spectrometers Vacuum systems * General purpose use and applications. Technical Benefits Safety functions 1) Self - protecting cut-off function and signal : - For over temperature, the power supply is automatically cut from the heater and controller systematically before the unit shuts down. - Over - current Circuit breaker for user safety. 2) Low fluid level and dry - running protection : - Intermittent tone alert sounds and optical signals alarms display on the control panel. 3) Double service valve provided to prevent refrigerant leakage. Optimum control performance 1) Functional LCD (resolution 0.1 ) keypad type display : Designed to simplify operation with a VFD touch screen type display (HL / HS-series) - Self-diagnostic function identifies equipment errors. - Recognizable and convenient keypad. - Clear and easy-to-use LCD display. 2) Bright LED water level indicator 3) Pump pressure gauge 4) Run, compressing, pumping visual indicator 5) Eco-friendly R-404A or R507 refrigerant Ideal construction 1) High quality #304 grade stainless steel inner chamber and dirt repellent powder coated external surface. 2) Stainless steel submerged parts are resistant to corrosion against all usual bath fluids. 3) Pump pressure can be controlled using a bypass function. (only for HX-H type) 4) Removable gridded vent for reducing condenser contamination and to facilitate cleanliness. 5) A wide (Ø120mm / 4.72 ) solution inlet is for easy and safe pouring of solution. 6) Wheels allow for easy mobility. 7) Computer Interface. (only HS series) 8) Warning alarm/monitoring system. - Over temperature. - Lack of bath solutions. 9) Pressure gauge comes standard with recirculating units to provide fluid system diagnostics at a glance and for observing the pump pressure. 6) Hot gas by-pass (only HL/HS series)

(Chillers) - Basic type Providing a constant temperature control and high cooling efficiency. Operating cost can be reduced by using the recirculator for cooling water. It is eco-friendly and reduces energy consumption. 72 Operating features Control temperature range is from 3 ~40. Clear and easy-to-use LCD display. (resolution 0.1 ) Bright LED water level indicator can be seen from a distance. Low fluid level and dry-running protection when triggered shows an error symbol on the display and an audible buzzer sound. If the equipment operates at 40 or above due to the external environment, user can simply identify the error with a visual signal or an audible buzzer sound. Pump pressure can be controlled using a by-pass function. (only H type) Constructional features LCD Display The refrigerating system is designed to reduce energy consumption and to maximize in refrigerating efficiency. Eco-friendly R-404A refrigerant is used to prevent environmental pollution. Double service valve is used to prevent refrigerant leakage. Removable gridded vent for reducing condenser contamination and to facilitate cleanliness. A plastic solution inlet is for easy and safe pouring of solution into the chiller unit. Pressure gauge comes standard with chiller units to provide fluid system diagnostics at a glance and for observing the pump pressure. Wheels allow for easy mobility throughout the lab. The beautifully designed chiller is compact. Different types of pumps and valves come standard with the chiller to provide versatility. Variety of accessories are available to meet user s different lab environment needs. (refer to accessories) Pressure Gauge Level Indicator Testing in accordance with DIN EN 12876 Optional Accessories see page 78-79 Fittings, Adapters Tubing, Insulations Tube clamps Bath fluid

(Chillers) - Basic type Pumping Capacities (Bath fluid : water) Magnetic Centrifugal 73 Specifications & Ordering Informations Model HX-20 HX-25 HX-20H HX-25H HX-35H HX-45H HX-55H Temperature 1) (bath fluid : water) Cooling capacity (bath fluid : water) Pump Working temperature range ( / ) Temperature stability at 15 (± / ) +3 to 40 / +37.4 to 104 at20 (kw) 1.9 2.4 1.9 2.4 3.6 4.7 7.1 at10 (kw) 1.4 1.7 1.4 1.7 3.1 3.6 5.1 at5 (kw) 1.0 1.4 1.0 1.4 2.4 2.9 4.2 Max. flow rate (L / min, gal / min) 1 / 1.8 38 / 10.03 38 / 10.03 45 / 11.89 45 / 11.89 45 / 11.89 45 / 11.89 45 / 11.89 Max. pressure (bar / psi) 1.58 / 22.92 1.58 / 22.92 4.3 / 62.37 4.3 /62.37 4.3 /62.37 4.3 / 62.37 4.3 / 62.37 Max. filling capacity (L / cu ft) 35 / 1.24 35 / 1.24 35 / 1.24 35 / 1.24 45 / 1.59 45 / 1.59 45 / 1.59 Dimension For tubing dia (mm / inch) Overall (W L H, mm / inch) 20 / 0.79 20 / 0.79 20 / 0.79 20 / 0.79 20 / 0.79 20 / 0.79 20 / 0.79 610 670 970 / 24.0 26.4 38.2 740 730 1065 / 29.1 28.7 41.9 Net weight (kg / lbs) 93 / 205 101 / 223 97 / 214 105 / 231 120 / 265 130 / 287 140 / 309 Electrical Requirements (220V, 60Hz) 8.5A 9A 9A 9.5A 15A AAA64011 AAA64021 AAA64111 AAA64121 AAA64131 - - Electrical Requirements (230V, 50Hz) 7A 7.6A 10.5A 11A 17A AAH64012K AAH64022K AAH64112K AAH64122K AAH64132K - - Electrical Requirements (120V, 60Hz) AAH64013U AAH64023U - - - - - Electrical Requirements (380V, 60Hz) 10A 11.5A - - - - - AAA64149 AAA64159 Electrical Requirements (380V, 50Hz) 7A 8.5A - - - - - AAH64148K AAH64158K 1) Technical data (according to DIN 12876) * Above speification value is recorded by 50Hz. 2) Only HX-45H, 55H is recorded by 380V, 60Hz. * The performance values refer to +20 (68 ) ambient temperature. * Product performance may be affected by ambient temperatures.

(Chillers) Low Temp. - General Type Powerful recirculating coolers, the HL series provide a wide range of cooling capacities with temperature reliability. Innovative control system, with a dynamic pumping capacity, and ideal for external temperature applications. Broad range of models to choose from based on working temperature range. 74 Operating features Temperature range is from -20 ~40. Bright LED water level indicator can be easily identified. Low fluid level and dry-running protection when triggered shows an error symbol on the display and an audible sound. If the equipment operates at 40 or above due to the external environment, user can simply identify the error with a visual or an audible sound. Designed to simplify operation with a touch screen type display. - Easy-to-read VFD display with interactive touch keys. - Setting and resolution indication 0.1 /. - Quick keypad lock prevents accidental parameter changes. - Signal indicator for operation status. Constructional features The refrigerating system is designed to reduce energy consumption and to maximize in refrigerating efficiency. Eco-friendly R-404A / R507 refrigerant is used to prevent environmental pollution. Double service valve is used to prevent refrigerant leakage. Removable gridded vent for reducing condenser contamination and to facilitate cleanliness. A wide (Ø120mm / 4.72 ) solution inlet is for easy and safe pouring of solution into the recirculating cooler. Pressure gauge comes standard for observing the pump pressure The refrigeration system can be observed easily to diagnostic at a glance by high / low pressure gauges. (HL-25H, 35H, 45H, 55H models) Wheels allow for easy mobility. The beautifully designed and compact. Different types of pumps come standard with the recirculating cooler to provide versatility. Warning alarm/monitoring system. - Over temperature. - Lack of bath solutions. Variety of accessories is available to meet user s different lab environment needs. (Refer to accessories) Testing in accordance with DIN EN 12876 Optional Accessories see page 78-79 Fittings, Adapters Tubing, Insulations Tube clamps Bath fluid

(Chillers) Low Temp. - General Type Pumping Capacities (Bath fluid : Ethtylene glycol mix 1:1 Water) Submersible pump pressure (Bar) 1.4 1.2 60Hz pressure (Bar) 6.0 5.0 pressure (Bar) 6.0 5.0 75 1.0 0.8 50Hz 4.0 4.0 50Hz, 60Hz 3.0 3.0 0.6 0.4 2.0 50Hz 60Hz 2.0 0.2 1.0 1.0 0 10 20 30 40 50 60 0 10 20 30 40 60 50 70 0 10 20 30 40 50 60 70 Flow rate (L/min) Flow rate (L/min) Flow rate (L/min) HL - 05, 10, 15, 20 models HL - 15H, 20H, 25H, 35H models HL - 45H, 55H models Specifications & Ordering Informations Temperature 1) (bath fluid : Ethtylene glycol mix 1:1 Water) Cooling capacity (bath fluid : Ethtylene glycol mix 1:1 Water) Model HL-05 HL-10 HL-15 HL-20 HL-15H HL-20H HL-25H HL-35H HL-45H 2) HL-55H 2) Working Temperature range ( / ) Temperature stability at 15, (± / ) -20 to 40 / -4 to 104 1 / 1.8 at 20 (kw) 0.60 0.70 1.45 1.80 1.45 1.80 2.50 3.30 6.50 7.10 at 10 (kw) 0.50 0.60 1.15 1.50 1.15 1.50 1.80 2.30 4.50 6.00 at 0 (kw) 0.35 0.42 0.86 1.15 0.86 1.15 1.10 1.70 3.00 4.10 at -10 (kw) 0.18 0.32 0.62 0.85 0.62 0.85 0.65 1.00 2.10 2.50 at -20 (kw) 0.04 0.14 0.30 0.40 0.30 0.40 0.40 0.55 1.20 1.50 Pump Max. flow rate (L / min, gal / min) Max. pressure (bar / psi) Max,. filling capacity (L, cu ft) 50 / 13.2 40 / 10.57 70 / 18.49 1.0 / 14.5 2.8 / 40.6 6 / 87.0 10 / 0.35 15 / 0.53 15 / 0.53 25 / 0.88 40 /1.41 Dimension For tubing dia (mm / inch) Overall (WxLxH, mm / inch) Net weight (kg / Ibs) 12.7 / 0.5 20 / 0.79 400 545 690 / 15.7 21.5 27.2 62.85 / 138.6 64.85/ 143.0 510 640 715 / 20.1 25.2 28.1 86.5 / 190.7 87.35 / 192.9 510 640 715 / 20.1 25.2 28.1 91.8 / 202.4 92.65 / 204.3 550 850 1100 / 21.7 33.5 43.3 141.3 / 310.9 146.3 / 321.9 Electric requirement (230V, 60Hz) 5.0A 5.5A 6.5A 7.5A 6.5A 7.5A 9.5A 13.5A 600 1000 1300 / 23.6 39.4 39.4 171 ±10 / 377 ±22 AAH65001 AAH65011 AAH65021 AAH65031 AAH65121 AAH65131 AAH65141 AAH65151 - - Electric requirement (230V, 50Hz) 4.5A 5.0A 6.0A 7.0A 6.0A 7.0A 7.5A 12.5A AAH65002 AAH65012 AAH65022 AAH65032 AAH65122 AAH65132 AAH65142 AAH65152 - - Electric requirement (120V, 60Hz) 10.0A 11.0A 13.0A 15.0A AAH65003 AAH65013 AAH65023 AAH65033 - - - - - - Electric requirement (380V, 60Hz) 5.5A 7.0A 176 ±10 / 388 ±10 - - - - - - - - AAH65169 AAH65179 Electric requirement (380V, 50Hz) 5.0A 6.0A - - - - - - - - AAH65168 AAH65178 1) Technical data (according to DIN 12876) * Above speification value is recorded by 50Hz. 2) Only HL-45H, 55H is recorded by 380V, 60Hz. * The performance values refer to +20 (68 ) ambient temperature. * Product performance may be affected by ambient temperatures.

(Chillers) Low Temp. - Intelligent Type Adjustable, precise PID temperature controller beneficial for various cooling tasks, for use in the science, research, and industrial laboratories. Innovative and exclusive controller can be adjusted the cooling capacity from 1% to 100% 76 Operating features Temperature range is from -20 ~40. As an option an external sensor can be directly installed into the cooling circuit for monitoring and regulating of temperatures. Precise temperature stability ± 0.2 (at 15 ) without heater. Bright LED water level indicator can be easily identified. Low fluid level and dry-running protection when triggered shows an error symbol on the display and an audible sound. If the equipment operates at 40 or above due to the external environment, user can simply identify the error with a visual or an audible sound. Designed to simplify operation with a touch screen type display. - Easy-to-read VFD display with interactive touch keys - Setting and resolution indication 0.1 / - Quick keypad lock prevents accidental parameter changes - Signal indicator for operation status Constructional features RS-232 Serial port & etc Digital controllor The refrigerating system is designed to reduce energy consumption and to maximize in refrigerating efficiency. Available external temperature sensor (Pt 100) for measured value Computer Interface -Software provided -Save data in excel format -Storage of program information, backup of value settings/recovery, and temperature values -RS-232C comes standard Eco-friendly R-404A / R507 refrigerant is used to prevent environmental pollution. Double service valve is used to prevent refrigerant leakage. Removable gridded vent for reducing condenser contamination and to facilitate cleanliness. A wide (Ø120mm / 4.72 ) solution inlet is for easy and safe pouring of solution into the recirculating cooler. Pressure gauge comes standard for observing the pump pressure The refrigeration system can be observed easily to diagnostic at a glance by high / low pressure gauges. (HL-25H, 35H, 45H, 55H models) The beautifully designed and compact. Different types of pumps come standard with the recirculating cooler to provide versatility Warning alarm/monitoring system - Over temperature - Lack of bath solutions Variety of accessories is available to meet user s different lab environment needs. (Refer to accessories)

(Chillers) Low Temp. - Intelligent Type Pumping Capacities (Bath fluid : water) Submersible pump pressure (Bar) 6.0 5.0 pressure (Bar) 6.0 5.0 77 4.0 4.0 3.0 50Hz, 60Hz 3.0 50Hz, 60Hz 2.0 2.0 1.0 1.0 0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70 Flow rate (L/min) Flow rate (L/min) HS-15, 20, 25, 35, 45, 55 models HS-25H, 35H, 45H, 55H models Specifications & Ordering Informations Temperature 1) (bath fluid : Ethtylene glycol mix 1:1 Water) Cooling capacity (bath fluid : Ethtylene glycol mix 1:1 Water) Model HS-15 HS-20 HS-25 HS-35 HS-45 HS-55 HS-25H HS-35H HS-45H HS-55H Working Temperature range ( / ) Temperature stability at 15, (± / ) -20 to 40 / -4 to 104 0.2 / 0.36 at 20 (kw) 1.45 1.80 2.50 3.30 6.50 7.10 2.50 3.30 6.50 7.10 at 10 (kw) 1.15 1.50 1.80 2.30 4.50 6.00 1.80 2.30 4.50 6.00 at 0 (kw) 0.86 1.15 1.10 1.70 3.00 4.10 1.10 1.70 3.00 4.10 at -10 (kw) 0.62 0.85 0.65 1.00 2.10 2.50 0.65 1.00 2.10 2.50 at -20 (kw) 0.30 0.40 0.40 0.55 1.20 1.50 0.40 0.55 1.20 1.50 Pump Max. flow rate (L / min, gal / min) Max. pressure (bar / psi) Max. filling capacity (L, cu ft) 40 / 10.57 70 / 18.49 3.3 / 47.86 6 / 87.0 15 / 0.53 25 / 0.88 40 / 1.41 25 / 0.88 40 / 1.41 Dimension For tubing dia (mm / inch) Overall (W L H, mm / inch) Net weight (kg / Ibs) 20 / 0.79 510 640 715 / 20.1 25.2 28.1 91.8 / 202.4 92.65 / 204.3 550 850 1100 / 21.7 33.5 43.3 141.3 / 310.9 146.3 / 321.9 600 1000 1300 / 23.6 39.4 39.4 168 ±10 / 370 ±22 173±10 / 381 ±22 550 850 1100 / 21.7 33.5 43.3 144.3 / 317.5 149.3 / 328.5 Electric requirement (230V, 60Hz) 6.5 A 7.5 A 9.5 A 13.5 A 9.5 A 13.5 A 600 1000 1300 / 23.6 39.4 39.4 171 ±10 / 377 ±22 AAH66011K AAH66021K AAH66031K AAH66041K - - AAH66131K AAH66141K - - Electric requirement (230V, 50Hz) 6.0 A 7.0 A 7.5 A 12.5 A 7.5 A 12.5 A AAH66012K AAH66022K AAH66032K AAH66042K - - AAH66132K AAH66142K - - Electric requirement (380V, 50 / 60Hz) 5.5 A 7.0 A 5.5 A 7.0 A 176 ±10 / 388 ±22 - - - - AAH66058K AAH66068K - - AAH55158K AAH66168K 1) Technical data (according to DIN 12876) * Above speification value is recorded by 50Hz. 2) Only HS-45H, 55H is recorded by 380V, 60Hz. * The performance values refer to +20 (68 ) ambient temperature. * Product performance may be affected by ambient temperatures.

Accessories & Options for 78 Barbed fittings Connectors / Adapters One touch adapters set Flexible fittings Barbed fittings Barbed fitting systems are geared for quick connecting of various size type tubes using pipe fittings, tube fittings, and hose fittings without tools. HXE1066 HXE1067 HXE1068 HXE1069 HXE1070 AAA64501 AAA64502 AAA64503 AAA64504 AAA64505 AAA64506 AAA64507 AAA64508 AAA64509 AAA64510 3/4 Male to barbed fitting for tubing 1 inner dia 3/4 Male to barbed fitting for tubing 3/4 inner dia 3/4 Male to barbed fitting for tubing 5/8 inner dia 3/4 Male to barbed fitting for tubing 1/2 inner dia 3/4 Male to barbed fitting for tubing 3/8 inner dia 1 Barbed fittings set with Ball valve 3/4 Barbed fittings set with Ball valve 5/8 Barbed fittings set with Ball valve 1/2 Barbed fittings set with Ball valve 3/8 Barbed fittings set with Ball valve 1 Barbed fittings set with Gate valve 3/4 Barbed fittings set with Gate valve 5/8 Barbed fittings set with Gate valve 1/2 Barbed fittings set with Gate valve 3/8 Barbed fittings set with Gate valve Connectors / Adapters HXE1105 3/4 Male to 3/4 Female HXE1106 3/4 Male to 5/8 Female HXE1107 3/4 Male to 1/2 Female HXE1108 3/4 Male to 3/8 Female HXE1109 3/4 Male to 3/4 Male HXE1110 3/4 Male to 5/8 Male HXE1111 3/4 Male to 1/2 Male HXE1112 3/4 Male to 3/8 Male One touch adapters set Connect and exchange rigid tubing easily. HXE1075 12mm One touch adapter id9.0mm, od12.0mm HXE1076 10mm One touch adapter id6.5mm, od10.0mm HXE1077 8mm One touch adapter id5.5mm, od8.0mm HXE1078 6mm One touch adapter id4.0mm, od6.0mm AAA64531 12mm Adapters set with Ball valve AAA64532 10mm Adapters set with Ball valve AAA64533 8mm Adapters set with Ball valve AAA64534 6mm Adapters set with Ball valve Flexible fittings Stainless tubing designed for superior flexibility and with good chemical resistance. HXE1071 HXE1072 AAA64521 AAA64522 AAA64523 AAA64524 3/4 Male to 3/4 Flexible fitting 3/4 Male to 1/2 Female with 1/2 Male to1/2 Flexible fitting 3/4 Flexible fittings set with Ball valve 1/2 Flexible fittings set with Ball valve 3/4 Flexible fittings set with Gate valve 1/2 Flexible fittings set with Gate valve

Accessories & Options for 79 Distributing fittings Tubing Tubing insulations Tube clamps Tubing HXE1079 1m 12mm Urethane tubing id9.0mm, od12.0mm HXE1080 1m 10mm Urethane tubing id6.5mm, od10.0mm HXE1081 1m 8mm Urethane tubing id5.5mm, od8.0mm HXE1082 1m 6mm Urethane tubing id4.0mm, od6.0mm HXE1083 1m 1 PVC tubing with thread id25.0mm, od31.0mm HXE1084 1m 3/4 PVC tubing with thread id19.0mm, od24.0mm HXE1085 1m 5/8 PVC tubing with thread id16.0mm, od20.5mm HXE1086 1m 1/2 PVC tubing with thread id12.0mm, od16.0mm HXE1087 1m 3/8 PVC tubing with thread id10.0mm, od14.0mm HXE1088 1m 1 PVC tubing with wire id25.0mm, od33.0mm HXE1089 1m 3/4 PVC tubing with wire id19.0mm, od26.0mm HXE1090 1m 5/8 PVC tubing with wire id15.0mm, od22.0mm HXE1091 1m 1/2 PVC tubing with wire id12.0mm, od18.0mm HXE1092 1m 3/8 PVC tubing with wire id9.0mm, od15.0mm Tubing insulations EPDM insulation is used to reduce heat loss and condensation from cold water plumbing, chilled water, and refrigeration lines. HXE1093 HXE1094 HXE1095 HXE1096 HXE1097 EPDM Insulation, 16mm inner dia.(9t) EPDM Insulation, 19mm inner dia.(9t) EPDM Insulation, 25mm inner dia.(9t) EPDM Insulation, 28mm inner dia.(9t) EPDM Insulation, 35mm inner dia.(9t) Flexible tubing HXE1073 3/4 Flexible tubing (sus304, m) HXE1074 1/2 Flexible tubing (sus304, m) Tube clamps HXE1098 1 Clamp HXE1099 3/4 Clamp HXE1100 5/8 Clamp HXE1101 1/2 Clamp HXE1102 3/8 Clamp Bath fluid Are bath fluids that may be suitable to use with the recirculating cooler, in place of water. HXE1113 HXE1114 HXE1115 Distilled water (20L) Ethylene glycol (4L) Ethylene glycol (20L) Distributing fittings Distributing fittings connect even with small tubes with barb fittings. External Sensor (only HS series) External temperature sensor (Pt 100) for measured value. AAA64541 3-Way distributing barbed fittings set (1/4 ) AAA64542 3-Way distributing barbed fittings set (3/8 ) CFA1943 3m cable for Pt 100 sensor