EDGEMERE CENTERSET LAVATORY FAUCET INSTALLATION INSTRUCTIONS 708.0 Thank you for selecting American Standard... the benchmark of fine quality for over 00 years. To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin. Certified to comply with ANSI A.8.M RECOMMENDED TOOLS Adjustable Wrench Channel Locks Plumbers Putty or Caulking Phillips Screwdriver Hex Wrench ( mm) INSTALL FAUCET CAUTION Turn off hot and cold water supplies before begining. Insert FAUCET () and POP-UP CABLE () through mounting holes of Sink or Mounting Surface. SECURE FAUCET AND MAKE WATER SUPPLY CONNECTIONS Secure FAUCET () with ATTACHMENT NUTS () supplied. (HAND TIGHTEN). Connect water supply to FAUCET () with /" IPS FLEXIBLE SUPPLIES () or /8"O.D. BULL-NOSE RISERS (). Use adjustable wrench to tighten connections. Do not over tighten. Be careful not to kink copper supply when bending. Use tubing cutter to cut to proper length. NOTE: FLEXIBLE SUPPLIES HAVE TO BE PURCHASED SEPARATELY COUPLING NUT FERRULE Product names listed herein are trademarks of AS America, Inc. AS America, Inc. 07 - - M965805 (/7)
POP-UP Fig. A. Fig. B. Remove CLEAR PLASTIC COVER (). Remove CARDBOARD SPACER () from under POP-UP (). Tighten TAILPIECE () on BODY before installing BODY. Fig. B. BODY REMOVE FLANGE Thread FLANGE () counter-clockwise and remove FLANGE () and FOAM GASKET () from drain body. Fig. A. Thread LOCKNUT () clock-wise to bottom of drain body. Push GASKET () down against LOCKNUT (). Fig. B Fig. A. Fig. B. 5 INSTALL FROM BELOW FIXTURE From under side of SINK install BODY () up through drain outlet. Note: No plumber s putty or caulk is required. The CABLE ATTACHMENT POINT () must face towards the rear of the SINK. Install FOAM GASKET () and FLANGE () onto drain body from above SINK and tighten FLANGE () firmly. OUTLET REAR OF SINK 5 TIGHTEN LOCKNUT Tighten LOCKNUT () firmly with Adjustable Wrench or Channel Locks. 6 FLANGE GASKET AND POP-UP KNOB Fig. A. Fig. B. DOWN Check FLANGE in SINK to ensure that WHITE FOAM GASKET () is fully compressed and not visible. Fig. A. POP-UP KNOB () must be fully down. Fig. B. WHITE FOAM GASKET NOT VISIBLE FLANGE - - M965805 (/7)
7 ATTACH CABLE CONNECTOR Thread CABLE CONNECTOR () clockwise onto BODY CONNECTION () and hand tighten. Fig. A. Your new POP-UP installation is now complete. Fig. B. Note: Tailpeice on pop-up drain is -/" O.D. Fig. B. Fig. A. Fig. B. -/ O.D. 8 CHECK OPERATION OF POP-UP Operate LIFT KNOB () to verify that STOPPER () opens and closes. Note: If STOPPER () does not open and close properly then refer to the troubleshooting section of these instructions. 9 TEST INSTALLED FAUCET Remove AERATOR. With handles in OFF position, turn on water supplies and check all connections for leaks. Operate both handles to flush water lines thoroughly. Operate LIFT ROD and check for leaks. Replace AERATOR. - - M965805 (/7)
0 SERVICE If Faucet Drips Proceed As Follows: Turn HANDLES in OFF position. If spout drips, operate HANDLES several times from OFF to ON position. Do not forc HANDLES they turn only 90. AERATOR may accumulate dirt causing distorted and reduced water flow. Remove AERATOR and rinse clean. To Change Handle Position: Remove INDEX BUTTON (), HANDLE SCREW () and HANDLE (). Remove ADAPTER () & RETAINING O-RING (5). Lift and turn STOP WASHER (6) 90. Replace RETAINING O-RING (5) & ADAPTER (). Replace HANDLE (). 90 5 6 Aerator 90 - - M965805 (/7)
Speed Connect Drain Troubleshooting Guide If sink does not hold water even though Stopper is in the down position: Follow CABLE ADJUSTMENT PROCEDURE. If Stopper does not raise up fully or sink drains too slowly: Follow CABLE ADJUSTMENT PROCEDURE. If you need to remove the Stopper: Follow STOPPER REMOVAL PROCEDURE. If you would like the ability to remove your Stopper simply by lifting it out of the drain: Follow STOPPER INSTALLATION PROCEDURE for Unlocked mode. CABLE ADJUSTMENT PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector () counter-clockwise. Fig. A. Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam in the illustration. Fig. B. Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the Stopper should be in the UP position. Fig. B, C. Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C. R e -attach the Cable to the Drain Body Connection () by threading the Cable Connector () clockwise onto the Drain Body Connection () and hand-tighten. Fig. A. Fig. A. Fig. B. Fig. C. DOWN RE-ATTACH CAM DISCONNECT CAM CAP STOPPER REMOVAL PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector () counter-clockwise. Fig. A. Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam and Cam Cap in the illustration. Fig. B. Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D. Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E. The Stopper can now be removed by lifting it out of the Drain. Fig. F. Fig. D. Fig. E. Fig. F. REMOVE CAM REMOVE CAM CAP - 5 - M965805 (/7)
STOPPER INSTALLATION PROCEDURE The Stopper can be installed two ways, Locked Mode (Stopper cannot be Removed) or Unlock Mode (Stopper is removable). Locked Mode: Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper. Fig. G. To install the stopper in Locked mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the Sink and the American Standard logo is facing front. Rotate Stopper slightly if necessary so that the Stopper slides all the way down. Fig. G. R e -install the Cam into the Drain, rotating the Cam if necessary to make sure it is fully inserted. Fig. J. R e -install the Cam Cap, making sure the guide teeth are facing outward. If the Cam Cap does not snap into place, then rotate the Cam to make sure it is fully inserted. Fig. K. R e -attach Cable. See CABLE ADJUSTMENT PROCEDURE in Troubling Shooting Guide to complete installation. Stopper will be in Locked mode and not be removable. LOGO LOOP TOWARD REAR OF SINK Locked Mode (Vandal Proof) Fig. G. Unlocked Mode: Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper. Fig. H. To install the stopper in Unlocked mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear. Rotate Stopper slightly if necessary so that the Stopper slides all the way down. Fig. H. R e -install the Cam into the Drain, rotating the Cam if necessary to make sure it is fully inserted. Fig. J. R e -install the Cam Cap, making sure the guide teeth are facing outward. If the Cam Cap does not snap into place, then rotate the Cam to make sure it is fully inserted. Fig. K. R e -attach Cable. See CABLE ADJUSTMENT PROCEDURE in Troubleshooting Guide to complete installation. Stopper will be in Unlocked mode and removable. LOGO 80 LOOP TOWARD FRONT OF SINK Fig. H. Unlocked Mode Fig. J. Fig. K. CAM INSTALL CAM INSTALL CAM CAP - 6 - M965805 (/7)
EDGEMERE CENTERSET LAVATORY FAUCET MODEL NUMBERS 708.0 M970007-YYY0A HANDLE KIT M9707-YYY0A LIFT ROD M950-0070A CABLE ASSEMBLY M97000-0070A AERATOR KIT M96005-0070A VALVE M955-YYY0A ASSEMBLY 065800-0070A ATTACHMENT NUT Replace the YYY with appropriate finish code CHROME 00 BRUSHED NICKEL 95 LEGACY BRONZE 78 HOT LINE FOR HELP For toll-free information and answers to your questions, call: (800) -90 Mon. - Fri. 8:00 a.m. to 8:00 p.m. EST Saturday 0:00 a.m. to :00 p.m. EST IN CANADA -800-87-069 (TORONTO -905-06-09) Weekdays 8:00 a.m. to 7:00 p.m. EST IN MEXICO 0-800-89-00 - 7 - M965805 (/7)