NEW Dual Certified Ex d & Ex e UNIONS Multi Angle Unions for Explosive Atmospheres CMP PRODUCTS

Similar documents
3.1. Ex-e/i Cable Glands Plastic version for Zone 1, 2, 21 and according to EN : 2012

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

REDUCER. Ex db, Ex eb, Ex tb, Ex nr, IP65/66/68. for General Industrial and Ex de I/IIC/IIC, Ex nr IIC

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Operating Instructions

4/2 way Pneumatic Solenoid Valve

PEPPERS CABLE GLANDS.

Cable Glands. Special Applications. RoHS Compliance. Plastic & Metal Cable Glands Adapters Reducers & Enlargers Grommets & Accessories

44 CE RANGE WATERTIGHT SURFACE-MOUNTING JUNCTION BOXES

METROSIL CURRENT TRANSFORMER PROTECTION UNIT (CTPU) ENCLOSURES IEC COMPLIANT

ECP Series Explosionproof Enclosures for OEM Applications. Optimized design, extensive sizes, and fast lead times.

IECEx Certificate of Conformity Annexe

Assembly instruction. Operating temperature range -60 C +85 C Protection. IP 66, 67, 68 (5 bar)

Certificate of Conformity

Plok. Rapid Mating Multi-Pin Industrial Connector. Amphenol Industrial Sine Systems * Pyle Connectors Corporation

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.

IECEx Certificate of Conformity

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET

Junction Boxes Series 8118

Hydro Bond Engineering Ltd Electrical Penetrators: Manned and Unmanned Systems HPS (Hydro Bond Penetrator Series)

1805 Series Relief Valves

Pressure Equalising Valves Model , for Differential Pressure Gauges

Terminal Head Section User Guide

Position switches FP series

Series CGCN self-centering three-jaw grippers with T-guide

HAZARDOUS AREA DIFFERENTIAL CLOGGING INDICATOR DEH SERIES

Safety relief valves, type BSV 8 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

CABLE ENTRIES IN HAZARDOUS AREAS CORRECT SELECTION, INSTALLATION AND MAINTENANCE

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

1305 Series Pressure Reducing Regulators

ABTQ-110 rev 00 (Last review: 28 Aug 12) INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR ABTECH S RANGE ENCLOSURES IECEx SIR U SERIAL No

February Cable glands For general industry and hazardous areas

IECEx Cert f cate of Gonform ty. IECEX SIR ' X issue No.:1 9-e j{ca!ells_tgryi _ lssue No. 1 ( ) lssue No.

@h..p. lntertek. IECEx Certificate of Conformity

Pressure switch, Differential pressure switch and Thermostat RT-E

MTB Load Cell. Globally Approved for Accuracy and Safety. MTB Load Cell Fully Approved

Industrial cable glands

ELECTRIC ACTUATORS for continuous underwater use

Series CGZT three-jaw grippers with T-guide

VEP-HDSERIES INTERCHANGE > Stucchi VEP profile

Operating Instructions

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

ITS 300 & 500 SERIES POSITION MONITORING INSTALLATION AND OPERATION MANUAL

IECEx Certificate of Conformity Annexe

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

Prewired position switches FA series

VEP-PSERIES INTERCHANGE > Stucchi VEP profile

PRESSURE REGULATORS. Type A/140. Process Management TM

Cameron MBS Multi-Bowl Wellhead System

Technical Guideline for Selection of Cable Gland

Heavy Duty Pocket Insets for the Oil & Gas Industry

FITTINGS THREAD LUBRICANTS. Fittings 20,000 PSI

TYPE 2800E EXTERNALLY MOUNTED, GAS LUBRICATED, NON-CONTACTING, DOUBLE CARTRIDGE SEAL

EX-RECESSED CEILING LIGHT FITTINGS

Series MX pressure regulators 3/

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

PRESSURE REGULATORS. Type B/240. Process Management TM

FLAMMABLE GAS SENSOR/TRANSMITTER

TYPE 7800 SERIES 7848D/7848W UNIVERSAL VESSEL SEAL Technical Specification

Electro-Pneumatic Converter YT-940 SERIES

Safety relief valves Type BSV-8

Pressure control, differental pressure control and thermostat Type RT

S.R.A. Fully Engineered Product Range

PN LINE. Technical remarks PN 11 PN 13 PN 14 PN 15 PN 17 PN 18 PN 20 PN 23 PN 25 PN 26 PN 27 PN 28 PN 29 PN 37 PN 38 PN 39 PN 40 PN 43 PN 10 8_9 10_12

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

GOST R CERTIFICATION SYSTEM FEDERAL AGENCY OF TECHNICAL REGULATION AND METROLOGY CERTIFICATE OF CONFORMITY

CMZ Series. Combination. FRZ Series. A combination to reliably remove water is now available!! ib-cyclone FRZ Series BK-P027- Filter regulator

Quick Disconnect Torch Upgrade for Kaliburn Spirit & ProLine

Flow Measurement SITRANS F C

Operating Instructions

Differential pressure

Magnetic level switch type MR783 Instruction Manual

9700 Transmitter Submersible hydrostatic level transmitter

TYPE ECS SEAL METAL BELLOWS DRY-RUNNING SECONDARY CONTAINMENT Technical Specification

Relief Valves. Relief Valves. International, Inc. Company ACIRCOR. RS Differential NB 9.5mm. RVA In-line Differential NB 6 to 19mm

Cable entries. Contents. Cable entries. Cable entries Introduction L.2 L.1. Standard cable glands - Plastic L.5. Standard cable glands - Brass L.

Thermal flow sensor TA Di for separate evaluation units for measuring mass flow, standard flow rate and air or gas consumption.

Osborne Engineering Limited. OEJ Equalised thrust bearing internals

THREADED CONNECTORS TEMPERATURE: 300 F [150 C] Body Material/ Contact Material/ O-ring. Connector Contact Terminations

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

NDE2 / NDH2 MOTORISED FURLERS. Comfort > Power > Reliability For boats from 9 to 22 m

World Area Differences Technical Information

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm

FUTURGAS VALVES. Components Pz. Materials

VG5 Supplementary instructions

Differential Pressure Control Types MP 54, MP 55 and MP 55A

Note: the lock-out circuit must be in accordance with Section 8.7 of DIN/VDE Twin thermostats ATH.-SW-2020 ATH.-SW-2070 ATH.

Dialight LED Conveyor Light - CE / RCM. for Indoor and Outdoor Industrial Applications

RECTANGULAR CONNECTORS

Specialists in HTM Medical Gas Pipeline Equipment AVSU/Module Operating and Maintenance Instructions

Differential pressure switch MP 54, MP 55 and MP 55A

SERIES 3000 SERIES 3000 SWISS MADE EN-ID-1017

SCHRADER TANK VALVES FOR USE IN AIR BLADDER APPLICATIONS, BICYCLE SUSPENSION SYSTEMS, TELECOMMUNICATIONS, WATER STORAGE SYSTEMS, ETC.

Clean Speed Controller with One-touch Fitting

Jamieson Equipment Company 5314 Palmero Court Buford, GA

TYPE 7828G/7828GD 7800 SERIES UNIVERSAL VESSEL SEAL Technical Specification

HI-PRESS HYDRAULICS Ltd

CPVC Transition Fittings - Female Adapter. CPVC X LEAD FREE BRASS Lead Free Max working pressure F ASTM D 2846

Transcription:

NW ual Certified x d & x e UNIONS Multi Angle Unions for xplosive Atmospheres CMP PROUCTS

780 SRIS Inline Union Union Type 780 with lameproof x d IIC & Increased Safety x e II forms of protection. The CMP Type 780 Metallic Union is designed to allow connection of rigid and flexible conduit, or terminated Cable Glands, to any fixed equipment. The 780 Union provides a running connection by means of an integral coupling arrangement that eliminates the need to rotate the conduit, or cable, or equipment to achieve a correct termination. The ease of installation offered by the 780 Union consequently makes the process of removing the conduit or other terminated cable entry device from the equipment a simple, fast and effective one. Available in rass, lectroless Nickel Plated rass, Aluminium or Stainless Steel these Unions are approved for use in conjunction with Class I, iv 1 and 2, x d and x e certified equipment and cable entry devices, and can also be supplied with thread conversion between the forward and rear threads to either a reduced size or a variety of different thread types, e.g. Metric to, or to metric. Type 780 II 2 G x d IIC Gb, x e IIC Gb, x ta IIIC a IP6X x d IIC Gb, x e IIC Gb, x d I Mb, x e I Mb, x ta IIIC a IP6X Class I, iv 1 & 2, Groups A,,C, ; nclosure type 4X : Class I, Zone 1, TC C-G.ГБ05.00138 x d IIC Gb U, x e IIC Gb U, x ta IIIC a U C A A General Purpose Industrial version is also available. Available with an integral O Ring seal. or such options please add above, e.g. 780RM2M2. NPSI Certificate GYJ13.1142X x d IIC Gb G3836.1,2,3-60 C to +200 C rass (standard), lectroless Nickel Plated rass, Aluminium, Stainless Steel (rass, Metric) MTRIC orward A emale (rass, ) orward emale ore iameter C lats Hex Ø 780M2M2 M20 X 1.5 15.0 M20 X 1.5 780T1T1 1/2 0.79 1/2 14.3 36.0 41.0 45.1 7 780M3M3 M25 X 1.5 15.0 M25 X 1.5 780T2T2 3/4 0.79 3/4 20.1 36.0 46.0 50.6 10 780M4M4 M32 X 1.5 15.0 M32 X 1.5 780T3T3 1 0.98 1 26.4 36.0 52.0 57.2 15 780M5M5 M40 X 1.5 15.0 M40 X 1.5 780T4T4 1-1/4 1.00 1-1/4 32.6 36.0 60.0 66.0 25 780M6M6 M50 X 1.5 15.0 M50 X 1.5 780T5T5 1-1/2 1.06 1-1/2 44.2 36.0 70.0 77.0 30 780M7M7 M63 X 1.5 15.0 M63 X 1.5 780T6T6 2 1.57 2 56.1 36.0 79.0 86.9 45 780M8M8 M75 X 1.5 15.0 M75 X 1.5 780T7T7 2-1/2 1.57 2-1/2 68.1 41.0 89.9 98.9 45 780M9M9 M90 X 2.0 24.0 M90 X 2.0 780T8T8 3 1.63 3 80.1 41.0 110.0 121.0 45 or material options please add the following suffix to the ; rass (no suffix required), Nickel Plated rass 5, 316 Grade Stainless Steel 4, Copper ree Aluminium 1

PX780RX SRIS Inline arrier Union *Ordered seperately arrier Union Type PX780RX with lameproof x d IIC & Increased Safety x e II forms of protection. The CMP Type PX780RX Rapidx Metallic arrier Union is designed to allow connection of rigid and flexible conduit, or terminated Cable Glands, to any fixed equipment. The PX780RX Union provides a running connection by means of an integral coupling arrangement that eliminates the need to rotate the conduit, or cable, or equipment to achieve a correct termination. Type PX780RX II 2 G x d IIC Gb, x e IIC Gb, x ta IIIC a IP6X C A The PX780RX also incorporates a barrier compartment. The ease of installation offered by the PX780RX arrier Union consequently makes the process of removing the conduit or other terminated cable entry device from the equipment a simple, fast and effective one. Available in rass, lectroless Nickel Plated rass, Aluminium or Stainless Steel these arrier Unions are approved for use in conjunction with Class I, iv 1 and 2, x d and x e certified equipment and cable entry devices, and can also be supplied with thread conversion between the forward and rear threads to either a reduced size or a variety of different thread types, e.g. Metric to, or to metric. x d IIC Gb, x e IIC Gb, x d I Mb, x e I Mb, x ta IIIC a IP6X Class I, iv 1 & 2, Groups A,,C, ; nclosure type 4X : Class I, Zone 1, TC C-G.ГБ05.00138 x d IIC Gb U, x e IIC Gb U, x ta IIIC a U Available with an integral O Ring seal. or such options please add above, e.g. PX780RXRM2M2. or epoxy compound version please remove RX from ordering reference -60 C to +85 C rass (standard), lectroless Nickel Plated rass, Aluminium, Stainless Steel (rass, Metric) MTRIC orward emale Size (rass, ) orward emale iameter Over Cores C. Number of Cores Postrusion lats Hex Ø PX780RXM2M2 M20 X 1.5 15.0 M20 X 1.5 PX780RXT1T1 1/2 0.79 1/2 12.6 11 36.0 46.0 50.6 7 PX780RXM3M3 M25 X 1.5 15.0 M25 X 1.5 PX780RXT2T2 3/4 0.79 3/4 17.5 21 36.0 50.0 55.0 10 PX780RXM4M4 M32 X 1.5 15.0 M32 X 1.5 PX780RXT3T3 1 0.98 1 23.6 38 36.0 60.0 66.0 15 PX780RXM5M5 M40 X 1.5 15.0 M40 X 1.5 PX780RXT4T4 1-1/4 1.00 1-1/4 30.0 59 36.0 65.0 71.5 25 PX780RXM6M6 M50 X 1.5 15.0 M50 X 1.5 PX780RXT5T5 1-1/2 1.06 1-1/2 41.0 59 36.0 75.0 82.5 30 PX780RXM7M7 M63 X 1.5 15.0 M63 X 1.5 PX780RXT6T6 2 1.57 2 53.7 89 36.0 90.0 99.0 45 PX780RXM8M8 M75 X 1.5 15.0 M75 X 1.5 PX780RXT7T7 2-1/2 1.57 2-1/2 64.3 115 39.0 100.0 110.0 45 PX780RXM9M9 M90 X 2.0 24.0 M90 X 2.0 PX780RXT8T8 3 1.63 3 75.3 140 42.0 120.0 132.0 45 or material options please add the following suffix to the ; rass (no suffix required), Nickel Plated rass 5, 316 Grade Stainless Steel 4, Copper ree Aluminium 1

784 SRIS 45 Union Union With 45 end Type 784 with lameproof x d IIC & Increased Safety x e II forms of protection. The CMP Type 784 Metallic Union is designed to allow connection of rigid and flexible conduit, or terminated Cable Glands, to any fixed equipment. The 784 Union provides a running connection at an angle of 45 by means of an integral coupling arrangement that eliminates the need to rotate the conduit, or cable, or equipment to achieve a correct termination. The ease of installation offered by the 784 Union consequently makes the process of removing the conduit or other terminated cable entry device from the equipment a simple, fast and effective one. Available in rass, lectroless Nickel Plated rass, Aluminium or Stainless Steel these Unions are approved for use in conjunction with Class I, iv 1 and 2, x d and x e certified equipment and cable entry devices, and can also be supplied with thread conversion between the forward and rear threads to either a reduced size or a variety of different thread types, e.g. Metric to, or to metric. A General Purpose Industrial version is also available. If 2 separate enclosures are required to be connected together please contact CMP Type 784 NPSI Certificate II 2 G x d IIC Gb, x e IIC Gb, x ta IIIC a IP6X x d IIC Gb, x e IIC Gb, x d I Mb, x e I Mb, x ta IIIC a IP6X C A G Class I, iv 1 & 2, Groups A,,C, ; nclosure type 4X : Class I, Zone 1, TC C-G.ГБ05.00138 x d IIC Gb U, x e IIC Gb U, x ta IIIC a U GYJ13.1142X x d IIC Gb G3836.1,2,3 Available with an integral O Ring seal. or such options please add above, e.g. 784RM2M2. -60 C to +200 C rass (standard), lectroless Nickel Plated rass, Aluminium, Stainless Steel (rass, Metric) orward MTRIC emale (rass, ) orward emale ore iameter C Overhang lats Hex Ø 784M2M2 M20 X 1.5 15.0 M20 X 1.5 784T1T1 1/2 0.79 1/2 14.3 61.0 56.0 46.0 50.6 7 784M3M3 M25 X 1.5 15.0 M25 X 1.5 784T2T2 3/4 0.79 3/4 20.1 66.0 62.0 50.0 55.0 10 784M4M4 M32 X 1.5 15.0 M32 X 1.5 784T3T3 1 0.98 1 26.4 70.0 70.0 60.0 66.0 15 784M5M5 M40 X 1.5 15.0 M40 X 1.5 784T4T4 1-1/4 1.00 1-1/4 32.6 75.0 77.0 65.0 71.5 25 784M6M6 M50 X 1.5 15.0 M50 X 1.5 784T5T5 1-1/2 1.06 1-1/2 44.2 94.0 88.0 75.0 82.5 30 784M7M7 M63 X 1.5 15.0 M63 X 1.5 784T6T6 2 1.57 2 56.1 103.0 103.0 90.0 99.0 45 or material options please add the following suffix to the ; rass (no suffix required), Nickel Plated rass 5, 316 Grade Stainless Steel 4, Copper ree Aluminium 1

PX784RX SRIS 45 arrier Union *Ordered seperately arrier Union with 45 bend Type PX784RX with lameproof x d IIC & Increased Safety x e II forms of protection. The CMP Type PX784RX Metallic arrier Union is designed to allow connection of rigid and flexible conduit, or terminated Cable Glands, to any fixed equipment at a 45 angle. The PX784RX Union provides a running connection by means of an integral coupling arrangement that eliminates the need to rotate the conduit, or cable, or equipment to achieve a correct termination. The PX784RX also incorporates a barrier compartment. The ease of installation offered by the PX784RX arrier Union consequently makes the process of removing the conduit or other terminated cable entry device from the equipment a simple, fast and effective one. Type PX784RX II 2 G x d IIC Gb, x e IIC Gb, x ta IIIC a IP6X x d IIC Gb, x e IIC Gb, x d I Mb, x e I Mb, x ta IIIC a IP6X C A G Available in rass, lectroless Nickel Plated rass, Aluminium or Stainless Steel these arrier Unions are approved for use in conjunction with Class I, iv 1 and 2, x d and x e certified equipment and cable entry devices, and can also be supplied with thread conversion between the forward and rear threads to either a reduced size or a variety of different thread types, e.g. Metric to, or to metric. If 2 separate enclosures are required to be connected together please contact CMP Class I, iv 1 & 2, Groups A,,C, ; nclosure type 4X : Class I, Zone 1, TC C-G.ГБ05.00138 x d IIC Gb U, x e IIC Gb U, x ta IIIC a U Available with an integral O Ring seal. or such options please add above, e.g. PX784RXRM2M2. or epoxy compound version please remove RX from ordering reference -60 C to +85 C rass (standard), lectroless Nickel Plated rass, Aluminium, Stainless Steel (rass, Metric) MTRIC orward emale Size (rass, ) orward emale Size iameter over Cores C. number of Cores Overhang lats Hex Ø PX784RXM2M2 M20 X 1.5 15.0 M20 X 1.5 PX784RXT1T1 1/2 0.79 1/2 12.6 11 61.0 56.0 46.0 50.6 7 PX784RXM3M3 M25 X 1.5 15.0 M25 X 1.5 PX784RXT2T2 3/4 0.79 3/4 17.5 21 66.0 62.0 50.0 55.0 10 PX784RXM4M4 M32 X 1.5 15.0 M32 X 1.5 PX784RXT3T3 1 0.98 1 23.6 38 70.0 70.0 60.0 66.0 15 PX784RXM5M5 M40 X 1.5 15.0 M40 X 1.5 PX784RXT4T4 1-1/4 1.00 1-1/4 30.0 59 75.0 77.0 65.0 71.5 25 PX784RXM6M6 M50 X 1.5 15.0 M50 X 1.5 PX784RXT5T5 1-1/2 1.06 1-1/2 41.0 59 94.0 88.0 75.0 82.5 30 PX784RXM7M7 M63 X 1.5 15.0 M63 X 1.5 PX784RXT6T6 2 1.57 2 53.7 89 103.0 103.0 90.0 99.0 45 or material options please add the following suffix to the ; rass (no suffix required), Nickel Plated rass 5, 316 Grade Stainless Steel 4, Copper ree Aluminium 1

789 SRIS 90 Union Union With 90 end Type 789 with lameproof x d IIC & Increased Safety x e II forms of protection. The CMP Type 789 Metallic Union is designed to allow connection of rigid and flexible conduit, or terminated Cable Glands, to any fixed equipment. The 789 Union provides a running connection at an angle of 90 by means of an integral coupling arrangement that eliminates the need to rotate the conduit, or cable, or equipment to achieve a correct termination. The ease of installation offered by the 789 Union consequently makes the process of removing the conduit or other terminated cable entry device from the equipment a simple, fast and effective one. Available in rass, lectroless Nickel Plated rass, Aluminium or Stainless Steel these Unions are approved for use in conjunction with Class I, iv 1 and 2, x d and x e certified equipment and cable entry devices, and can also be supplied with thread conversion between the forward and rear threads to either a reduced size or a variety of different thread types, e.g. Metric to, or to metric. A General Purpose Industrial version is also available. If 2 separate enclosures are required to be connected together please contact CMP Type 789 NPSI Certificate II 2 G x d IIC Gb, x e IIC Gb, x ta IIIC a IP6X x d IIC Gb, x e IIC Gb, x d I Mb, x e I Mb, x ta IIIC a IP6X Class I, iv 1 & 2, Groups A,,C, ; nclosure type 4X : Class I, Zone 1, TC C-G.ГБ05.00138 x d IIC Gb U, x e IIC Gb U, x ta IIIC a U GYJ13.1142X x d IIC Gb C A G Available with an integral O Ring seal. or such options please add above, e.g. 789RM2M2. G3836.1,2,3-60 C to +200 C rass (standard), lectroless Nickel Plated rass, Aluminium, Stainless Steel (rass, Metric) orward MTRIC emale Size (rass, ) orward emale ore iameter C Overhang lats Hex Ø 789M2M2 M20 X 1.5 15.0 M20 X 1.5 789T1T1 1/2 0.79 1/2 14.3 63.0 64.0 46.0 50.6 7 789M3M3 M25 X 1.5 15.0 M25 X 1.5 789T2T2 3/4 0.79 3/4 20.1 71.0 70.0 50.0 55.0 10 789M4M4 M32 X 1.5 15.0 M32 X 1.5 789T3T3 1 0.98 1 26.4 76.0 78.0 60.0 66.0 15 789M5M5 M40 X 1.5 15.0 M40 X 1.5 789T4T4 1-1/4 1.00 1-1/4 32.6 84.0 85.0 65.0 71.5 25 789M6M6 M50 X 1.5 15.0 M50 X 1.5 789T5T5 1-1/2 1.06 1-1/2 44.2 96.0 97.0 75.0 82.5 30 789M7M7 M63 X 1.5 15.0 M63 X 1.5 789T6T6 2 1.57 2 56.1 109.0 115.0 90.0 99.0 45 or material options please add the following suffix to the ; rass (no suffix required), Nickel Plated rass 5, 316 Grade Stainless Steel 4, Copper ree Aluminium 1

PX789RX SRIS 90 arrier Union *Ordered seperately arrier Union with 90 bend Type PX789RX with lameproof x d IIC & Increased Safety x e II forms of protection. The CMP Type PX789RX Metallic arrier Union is designed to allow connection of rigid and flexible conduit, or terminated Cable Glands, to any fixed equipment at a 90 angle. The PX789RX Union provides a running connection by means of an integral coupling arrangement that eliminates the need to rotate the conduit, or cable, or equipment to achieve a correct termination. The PX789RX also incorporates a barrier compartment. The ease of installation offered by the PX789RX arrier Union consequently makes the process of removing the conduit or other terminated cable entry device from the equipment a simple, fast and effective one. Type PX789RX II 2 G x d IIC Gb, x e IIC Gb, x ta IIIC a IP6X x d IIC Gb, x e IIC Gb, x d I Mb, x e I Mb, x ta IIIC a IP6X C A G Available in rass, lectroless Nickel Plated rass, Aluminium or Stainless Steel these arrier Unions are approved for use in conjunction with Class I, iv 1 and 2, x d and x e certified equipment and cable entry devices, and can also be supplied with thread conversion between the forward and rear threads to either a reduced size or a variety of different thread types, e.g. Metric to, or to metric. If 2 separate enclosures are required to be connected together please contact CMP Class I, iv 1 & 2, Groups A,,C, ; nclosure type 4X : Class I, Zone 1, TC C-G.ГБ05.00138 x d IIC Gb U, x e IIC Gb U, x ta IIIC a U Available with an integral O Ring seal. or such options please add above, e.g. 7PX89RXRM2M2. or epoxy compound version please remove RX from ordering reference -60 C to +85 C rass (standard), lectroless Nickel Plated rass, Aluminium, Stainless Steel (rass, Metric) MTRIC orward emale Size (rass, ) orward emale Size iameter over Cores C. number of Cores Overhang lats Hex Ø PX789RXM2M2 M20 X 1.5 15.0 M20 X 1.5 PX789RXT1T1 1/2 0.79 1/2 12.6 11 63.0 64.0 46.0 50.6 7 PX789RXM3M3 M25 X 1.5 15.0 M25 X 1.5 PX789RXT2T2 3/4 0.79 3/4 17.5 21 71.0 70.0 50.0 55.0 10 PX789RXM4M4 M32 X 1.5 15.0 M32 X 1.5 PX789RXT3T3 1 0.98 1 23.6 38 76.0 78.0 60.0 66.0 15 PX789RXM5M5 M40 X 1.5 15.0 M40 X 1.5 PX789RXT4T4 1-1/4 1.00 1-1/4 30.0 59 84.0 85.0 65.0 71.5 25 PX789RXM6M6 M50 X 1.5 15.0 M50 X 1.5 PX789RXT5T5 1-1/2 1.06 1-1/2 41.0 59 96.0 97.0 75.0 82.5 30 PX789RXM7M7 M63 X 1.5 15.0 M63 X 1.5 PX789RXT6T6 2 1.57 2 53.7 89 109.0 115.0 90.0 99.0 45 or material options please add the following suffix to the ; rass (no suffix required), Nickel Plated rass 5, 316 Grade Stainless Steel 4, Copper ree Aluminium 1

NWCASTL (Headquarters) Tel: +44 (0) 191 2657411 ax: +44 (0) 1670 715 646 -Mail: customerservices@cmp-products.com CMP Products 36, Nelson Way, Nelson Park ast Cramlington, Northumberland N23 1WH, United Kingdom HOUSTON (Texas Inc) Tel: +281 776 5201 ax: +281 776 5223 -Mail: houstonoffice@cmp-products.com CMP Products Texas Inc 5222 N. Sam Houston Pkwy. Houston, Texas, 77032, USA PRTH, WA Tel: +61 8 9249 4508 ax: +61 8 9249 4608 -Mail: perthoffice@cmp-products.com CMP Products Pty Ltd Unit 3-22 Harlond Avenue, Malaga, WA 6090 Australia RISAN, QL Tel: +61 7 3801 0301 ax: +61 7 3801 0300 -Mail: qldoffice@cmp-products.com CMP Products Pty Ltd Unit 2 / 1-5 Knobel Court, Shailer Park, QL 4128 Australia UAI Tel: +971 4 887 1012 ax: +971 4 887 1015 -Mail: meoffice@cmp-products.com CMP Products Middle ast Office Office 6WA Room 134, PO OX 371725 ubai Airport ree Zone, ubai, United Arab mirates PUSAN Tel: +82 51 780 5300 ax: +82 51 780 8348 -Mail: pusanoffice@cmp-products.com CMP Products (Korea) Ltd 19 Rm1915 Centum IS Tower, #1209, Jaesong1-dong, Haeundae-gu, usan, South Korea, 612051 SINGAPOR Tel: +65 6466 6180 ax: +65 6466 9891 -Mail: seaoffice@cmp-products.com CMP Products (S..A) Pte Ltd. 21 Toh Guan Road ast, #09-03, Toh Guan Centre, Singapore 608609 SHANGHAI Tel: +86 21 6093 2633 ax: +86 21 6093 2630 -Mail: shanghaioffice@cmp-products.com CMP Products ivision Room 304, uilding 7, No.1888 XinJinqiao Road Pudong, Shanghai 201206, P.R. China CMP PROUCTS TPC 201 - Issue 2-07/14 JOHANNSURG Tel: +27 79 866 2171 ax: +27 86 554 3240 -Mail: africaoffice@cmp-products.com CMP Products 49 New Road, lock A, Ground loor Midrand,1685, Johannesburg, S.A