MANY REQUIREMENTS - ONE SOLUTION: SCENTY control

Similar documents
IBEDA GAS MIXERS HIGHEST PRECISION FOR YOUR WELDING AND CUTTING PROCESSES

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

PHOENIX L300i Best-in-class Helium Leak Detectors

We measure it. For gas and water installers. testo hpa. bar

2018 National Metal and Nonmetal Mine Rescue Contest. Technician Team Competition Written Test (Dräger BG-4) Good Luck!

Apollo Safety Features

Nothing's as cool, as a freshwater pool. easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

Transmitter CS 21 Operation Manual

CO 2 and O 2 scrubbers

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

High Pressure Breathing Air Compressors

EasyLine Continuous Gas Analyzers. So smart, they re simple

Columbus Instruments

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Aqua-DP. Aqua-DP Waterproof Dissolved Oxygen - ph -mv Temperature Meter. TPS Australia - Quality hand-made instruments since 1968.

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Flow metering in gases Introduction to COMBIMASS family

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

GAS FILLING MACHINES PROCESS MONITORING PRESSURE BALANCE

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

B-DETECTION PLUS THE NEXT GENERATION MOBILE AND STATIONARY GAS MEASUREMENT SYSTEMS

GENO -Flushing Compressor Product Data Sheet F 02

VACCUPERM Vacuum chlorine gas dosing systems

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

Dräger X-dock Frequently Asked Questions

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Technical Data Sheet MF010-O-LC

Optical Interferometric Gas Concentration Meter FI-8000 Operating Manual (PT3-052)

Technical Data and Specifications

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:

Instruction Manual Dräger MSI P7 and MSI P7 plus

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

CAPITAL CONTROLS SERIES NXT3000

CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Ruskinn Hypoxia and Anoxia Workstations. innovation in incubation

Quick Start Guide. A. Hardware installation B. Software installation C. Start the software for the first time D. Do your first measurement

CCS240 and CCS241. Technical Information. Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly

G100 RANGE G100, G110, AND G150 OPERATING MANUAL

NGN Series nitrogen generator

HumiSys HF High Flow RH Generator

RAM Operation Manual

EasySas. The most advanced airlock electronics on the market. Recyclable product. Eco-design. Energy savings

X-dock Software History

Transmitter CS 21 Operation Manual

RAM 4021-DPX Operation Manual

130 SSP Soluble Salt Profiler

Pressure Calibrators. Series PC..., PM...

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2

Simple, Robust, Reliable Measures ph Doses either acid (lower) or alkali (raise) Displays ph, Total Dose Count (DCT) and Dose Count per hour (DC/h)

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Panther 5 Acute Care Ventilator

TABLE OF CONTENTS INTRODUCTION 3 SAFETY PRECAUTIONS 3 PACKAGE CONTENTS 4 DEVICE OVERVIEW 4 BUTTON OPERATION SUMMARY 5 BASIC OPERATION 6

THE WATER-COOLED INDUSTRIAL RANGE

SCAM T.P.E. WATER TREATMENT SYSTEM SWT- AP AUTOMATIC PURGE

Narkomed MRI-2. A perfect fit for the MRI environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Optical Interferometric Gas Concentration Meter FI-8000 Operating Manual (PT3-052)

Control & Maintenance. INT69 Diagnose INT69 TM Diagnose. Protect the heart of your system

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

TransPort PT878GC Panametrics Portable Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

Pneumatic service kit Model CPG-KITP

Using the UltraRAE. Firmware 2.35

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

BUBBLER CONTROL SYSTEM

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

CALIBRATION KIT. Instruction Manual

MEDIANA HEARTON AED A15. Mediana Automated External Defibrillator A15

Operating Instructions DB41

INSTRUCTION MANUAL FOR. Chlorinator M 3600 C Controlmatik ABW

...makes sense! Combined CO 2 /O 2 analyzers. Monitor your process in real-time: OUR CER. BlueSens.com

Gas-Detection Instruments

h2000 plus HyDROGEN LEAk DETECTOR

Quick Installation Guide Doc nr.: C Date:

Synthetic air supply by WITT hygienic, safe, cost-effective!

These Terms and conditions apply to audit trails incorporated in weighing and measuring devices and systems 1.

WF STEUERUNGSTECHNIK GMBH. INFORMATION and TECNICAL DESCRIPTION

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

RS D RSF D with direct drive

O NEof Premium tools for professionals!

WITT-GASETECHNIK GMBH & CO KG

Operating manual for the pressure transducer unit CCS 1000

EtO Micro-Dose Sterilization

Product Information. Three in One: Gas Meter Tariff Device Volume Corrector. Ultrasonic Gas Meter ECOSONIC X12

Digital pressure gauges

CITREX H4 Mobile gas flow analyser. The ideal mobile device for flow and pressure analysing.»

The anaesthesia workstation focused on you

Model : LMW-9620 Please read this manual carefully before using the instrument Labnics Equipment

* Analysis of TCG ( Total Combustible Gas ) and 6 kinds of Gases * High Sensitivity for C 2

Airox Supportair Ventilator

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

Portable Multi-Gas Monitor RX-8500/RX-8700 Operating Manual (PT0-136)

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP

Frazier Permability Tester & Average Fiber Diameter Analyzer. Permeability measurement according to ISO: 4003 & ASTM D standard

Transcription:

MANY REQUIREMENTS - ONE SOLUTION: SCENTY control NOW BRAND NEW AtmoCheck mobile RELIABLE CONTROL AND MONITORING OF Degreening Sprouting inhibition For fast and independent monitoring of residual gases Growth promotion

SCENTY control Control and monitoring of ripening processes By accurately metering the supply of either pure ethylene gas or a mixture of nitrogen and ethylene, the ripening process of fruits and vegetables can be scheduled to occur at a specific planned time. However, with certain fruits and vegetables, ethylene can produce exactly the opposite results as it can inhibit sprouting. SCENTY control one solution for many areas of application: Degreening Growth promotion Sprouting inhibition With SCENTY you can increase the quality of your products since chemical anti-sprouting products are no longer necessary. Degreening or storage becomes residue free and without chemicals. THE COMPONENTS Perfectly adapted GSC 200ETH SCENTY Flow Control SCENTY GWA 201 This compact unit allows you to control the correct dosage. In addition to the main valve, it is also equipped with a pressure reducer and a flow regulator. This is the evaluation unit with an integral LCD screen. LED indicators show the current state of each individual process. This well-engineered and reliable component ensures that all ripening and storage processes of your products are completed safely. This electrochemical gas measuring sensor has been developed specifically for use with degreening and sprouting inhibition. The SCENTY control can be accurately adjusted to perfectly meet your application requirements, due to its high degree of accuracy and the wide measurement ranges of its sensor. The use of proven Gore-Tex technology ensures that it remains waterproof whilst giving optimum gas permeability. Gore-Tex is a registered trademark of W.L. Gore & Associates

APPLICATION EXAMPLE with premixed ethylene and nitrogen gas Premixed gases of ethylene and nitrogen are non-flammable due to the inert gas content. Therefore, specific fire or explosion protection measures are not required in the ripening rooms when using premixed gases and SCENTY control. Nevertheless, we recommend the use of gas detection systems which are designed for use in the food industry and which also ensure safety. With this reliable and proven hardware, the ripening and storage processes of all of your products will always be safe and consistent. In addition, we recommend that you observe and comply with the instructions in the safety data sheet and the IGS safety recommendations. THE SCENTY control REGULATOR UNIT The system for operation with premixtures Premixture Dosing Controller Ripening gas Measurement SCENTY control consists of an evaluation unit to which an ethylene gas sensor is connected. The current concentration of ethylene is continuously shown on the integrated LCD display. LED indicators show whether ethylene is being rendered intert, or if the system is in standby mode. The supplied flow control unit is equipped with a pressure reducer, a flow regulator and the main solenoid valve. If the minimum threshold value is not maintained, the SCENTY control automatically readjusts the amount of ethylene being dosed and switches off the gas when the maximum concentration is reached. By viewing the flowmeter and adjusting the corresponding regulator valves, it is easy to set exactly the correct dosage (l/min). The system operates fully independently, and can be upgraded easily with minimal technical knowledge. An equipment cabinet for holding the individual cylinders or cylinder bundles, the pressure reducer and the tapping points can be obtained from your gas supplier.

APPLICATION EXAMPLE System operating with pure ethylene Certain application processes do not allow the use of premixed gases. SCENTY control EX is the solution for operation with flammable gas. SCENTY control EX significantly reduces the risk of explosions. Safety is one of our top priorities. Ripening gas Flow sensor 100% ethylene Ripening gas/ ventilation Dosage (flowbox) Control Ethylene measuring sensor SCENTY control / SCENTY control EX Safe, proven technology Please see our optional solutions on the next page Technical Data SCENTY control / SCENTY control EX Housing Plastic wall housing Protection Class IP65, SCENTY control EX suitable for installation in EX areas Measuring Points 1 Measuring sensor, optionally available with up to 8 measuring points (SCENTY control 801) Measuring Range 0-10 ppm, 0-25 ppm, 0-2000 ppm Flow Rate 0-2 l/min., 0-10 l./min., 0-25 l./min. Larger ranges are available on request. Display Ethylene concentration LED Display Operating, alarm, fault and maintenance signal Manual Alarm Prevention Menu function allows Alarm Prevention in certain special cases System Fault message, alarm message, watchdog function, self-monitoring, system clock, cold start, check alarm, sensor / calibration monitoring, maintenance interval monitoring Electrical Supply 110-230V 50/60Hz or 24VDC Data logger added options with SCENTY control 801 Measurement data and alarm memory via SD card with read-out via included PC software and USB interface

AtmoCheck Mobile For fast and independent monitoring of residual gases AtmoCheck mobile for ethylene was developed specifically for greenhouse application. This practical measuring device is particularly well suited for mobile measurement of ethylene concentrations. Fixed measuring sensor Hard to reach areas can be measured easily and reliably with the suction lance that is part of the system. AtmoCheck mobile is characterised by its comfortable, easy operation, fast response and high degree of accuracy. Permanent monitoring takes place via the fixed measuring sensor Scenty control EX. (see inside pages) Use AtmoCheck Mobile to check independently and quickly. Different measuring ranges from 0-10, 0-25, 0-100, 0-200 and 0-2000 ppm are available. The large size LCD is easy to read and displays the actual concentration of ethylene. AtmoCheck Mobile is also available as an optional dual function analysing device for the simultaneous measurement of CO 2 and ethylene concentration. Integral battery gives unrestricted power-independent operation. (Charger included) Flexible hose Measuring lance Handheld device AtmoCheck Mobile in a handy case with complete accessories including Suction lance with handle, with handle approx. 35 cm long Flexible PVC hose with bayonet coupling. Approx. length 100 cm. The AtmoCheck Mobile comes in a handy carrying case with a wide range of accessories. The AtmoCheck Mobile charger for the integral battery comes with power plug adapters for home and abroad. 2 suction filters

SCENTY control EX Installation in EX areas Additional model for use with pure ethylene. The tapping and regulator units are suitable for installation in EX areas. The evaluation unit is installed outside of the EX areas. Consult your gas supplier regarding this matter. EX area SCENTY control OPTIONS for even more reliability and control SCENTY control TOTAL You can use a battery powered electronic flowmeter from the compact series as an added option. The integrated flow meter displays the total amount of ethylene used and can be read daily. Air flow sensor The use of pure ethylene should be accurately regulated, ensuring that there is always an adequate flow velocity in the air supply duct. An optional flow sensor can be integrated into the system to adjust the gassing cycles of the supply and circulating air. Rev.I_032015_Br_SCENTY control_a4_engl subject to technical alterations HTK Hamburg GmbH Frahmredder 49 22393 Hamburg Limit switch for ventilator flaps Switch-off the SCENTY control during the aeration phases. An optional limit switch can be integrated to monitor when the ventilator flaps are open, and automatically pause gas dosing accordingly. This not only ensures optimum regulation of ethylene for your processes, it also saves you gas. Phone: +49 (0)40-600 3838-0 Fax: +49 (0)40-600 3838-99 E-Mail: info@htk-hamburg.com Internet: www.htk-hamburg.com www.htk.hamburg