Directions for Use. Vivaflow 50 50R

Similar documents
User Guide. Amicon Stirred Cells. Cat. No. UFSC05001, 50 ml UFSC20001, 200 ml UFSC40001, 400 ml

A Perspective on Filter Cartridge Issues

OVERVIEW METCELL SPECIFICATIONS. Lab scale nanofiltration equipment The METcell Range

1020 Industrial Drive, Orlinda, TN fax

Standard Flexel 3D bioprocessing bags for Palletank

16 Ideal for standard laboratory chromatography. 19 High temperature columns ideal for flow chemistry

Vibro -LE Manual. Please be sure to read this entire user manual prior to use of the equipment. Please read all safety instructions carefully.

Techcon Systems TS1254 Pressure Pot

Stirred Ultrafiltration Cells Models 8003, 8010, 8050, 8200, User Guide

Valve INV-907. Instructions. 1 Introduction. 2 Installation. Safety. Unpacking. Installing the valve

Operating Guidelines for PermSelect Modules Liquid Contacting

OPERATING MANUAL LO-CROSS-FLOW CF M

Stirred Ultrafiltration Cells

Solvent Resistant Stirred Cells for Ultrafiltration and Filtration Applications

BIOSTAT CultiBag RM Culturing Convenience

6900 Maintenance Instruction System Flush

These variables can be accessed by holding the UP button for 5 seconds.

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

Preparation of a new hollow fiber cartridge

User's Manual. MixRite TF 10. Edition 05.08

Multi-Probe Sampling System User Guide & Manual

Concentration and diafiltration of viral antigens with SmartFlow TFF

Fiber Optic SMA Z-Flow Cell Manual Version 2.1

Operating Instructions Model and Hydrostatic Test Pump

PROTEAN plus Multi-Casting Chamber. Instruction Manual

Zero Head Space Extractor. Catalogue No. YT HW. Operation and Maintenance Manual

O P E R A T O R S M A N U A L

Techcon Systems TS1258 Pressure Pot

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

2D Labtainer BioProcess Container (BPC) systems

Manual Solvent Purification System. Innovative Technology, Inc.

Membrane Air Dryer. IDG1-C06 Series IDG1-C06-P Series

WHITE PAPER Overview of Diaphragm and Chemical Seals

GE Healthcare. BPG Columns. Instructions for Use

A Quick Start Guide for the ER 4123D CW-Resonator

Cavitron DualSelect. Introduction ENGLISH. Directions For Use. Cavitron DualSelect Dispensing System ENGLISH 1

Using the Akta Prime plus October 22, 2012

InFlow Modular perfusion bioreactor

AKTA 3D SOP. Click on the System Control tab. This screen has 4 windows.

DISSOLUTION TEST FOR SOLID DOSAGE FORMS

EcoCell Vertical Electrophoresis Unit

Manual. Online Degasser DDG-75. Manual Degasser DDG-75 April DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE Hockenheim Germany

NanoSight NS300. NanoSight NS300. Operation instructions. Laser Spectroscopy Labs, UCI

SOLVENT PURIFICATION SYSTEMS

Oxygen Dipping Probe PSt3 / PSt6 / PSt9

3-Way Decoking Valve Option - Installation and Operation Instructions Accessory G Background

POWER FLUSH KIT INSTRUCTIONS

Nothing's as cool, as a freshwater pool. easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump

After filling the pool with clean water in the summer, two basic factors can take place due to the exposure of water to the sun and the air.

Type C-CUT. Quickstart. English Deutsch Français

P/N: IND-DP Industrial Drum Pumps

AKTA ION EXCHANGE CHROMATOGRAPHY SOP Date: 2/02/05 Author: A DeGiovanni Edited by: C. Huang Reviewed by:

Type T-CUT PP. Operating Instructions. Bedienungsanleitung Manuel d utilisation

AKTA pure 25 New Owner s Intro

This Page Intentionally Left Blank 2

Technical Service Bulletin June 2015 TSB122.06

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

Radnoti Liver Perfusion System

Clean Regulator/Fluororesin Type

Instructions For Use. USD 2474a. Pall Minidisc Filter Capsules with Ultipor DV20 Virus Removal Filter Membrane

Type T-CUT. Operating Instructions. Bedienungsanleitung Manuel d utilisation

This Page Intentionally Left Blank 2

Technical Information

Keofitt Aseptic Sampling Bag (Pat. pend.) Item no , & User Manual

KEOFITT ASEPTIC SAMPLING BAG (PAT. PEND.) Item no , & User Manual

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order. Option. Symbol.

SOP: Buck Scientific BLC-20P HPLC Operation

ANION SELF-REGENERATING SUPPRESSOR 300 (ASRS 300 (4-mm), P/N ) (ASRS 300 (2-mm), P/N )

ULTRA PURE SYSTEMS 625 GPD RODI INSTALLATION AND OPERATION MANUAL

CS Controlled Dissolved Gas assembly with optional CS Air Aspirator assembly. Installation and Operation information

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Blaustein Atomizer (BLAM) Multi-jet Model. User s Manual

REVERSE OSMOSIS WATER FILTRATION SYSTEM MODEL EWR 4075 INSTRUCTION MANUAL

Instruction Manual Updated 7/26/2011 Ver. 2.2

Pilot Check Valve: Metal Body Type

AKTA MC SOP Page 1 9/27/04 AKTA METAL CHELATING SOP

Agilent 1290 Infinity Pump Head Maintenance

Minipuls evolution fitted with three 4-channel Medium Flow pump heads. one 4-channel Medium Flow pump head and one 2-channel High Flow pump head

PRESSURE MYOGRAPH - 114P PULSATILE PRESSURE MYOGRAPH - 112PP

DRAFT Standard Operating Procedure Ultrafiltration and Reverse Osmosis

PRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09

order-no: / 13 Kunden-Nummer Kunden-Name Aktualisierungsdatum checked (140/140) 1, 2-dichloroethane

ACV-10 Automatic Control Valve

Rev. A Jul 07 Part # SS VD510-SS INSTRUCTION MANUAL DISPENSING VALVE MODEL VD510-SS INSTRUCTION MANUAL

Technical Service Bulletin October 2013 TSB135.03

Type C-CUT. Operating Instructions. Bedienungsanleitung Manuel d utilisation

BS ml Bottle Sampling Unit

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

Same as 90P except has Teflon seals extending the range of chemicals that can be pumped.

Flow experiment with the ibidi pump system and µ-slide I 0.6 Luer

Technical Service Bulletin Oct 2017 TSB122.07

INSTRUCTION MANUAL FOR POLYKEG DISPOSABLE KEG

Siphon vessel / Priming aid

Strength. NORMAPLAST Plastic Products. The best way to connect hose and tube NORMAPLAST

ISOMEGA BLADDER PUMPS

TANK LINING RESISTANCE GUIDE I-19

Model 2000 High-performance Ultrafiltration Cell

Axial Compression Packing Method

Emulsiflex C3 Homogenizer Protocol

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Solid Indicator (Non-mixer) Model CP-30SI

Transcription:

Directions for Use Vivaflow 50 50R 200 85030-519-25

Contents Vivaflow 50 3 Single Module 3 Linked Modules 4 Diafiltration Desalting 5 Concentration 6 Recovery 6 System Components 7 Technical Specifications 7 Performance Characteristics 8 Ordering Information 9 Chemical Compatibility 10 Vivaflow 50R and Vivaflow 200 11 Operation of Single Module 11 Operation of Two Modules 12 13 Diafiltration Desalting 14 Concentration 14 Recovery 14 Technical Specifications 15 Cleaning 16 Storage 16 Performance Characteristics 17 18 Ordering Information 19 20 Chemical Compatibility 21 2

Vivaflow 50 Designed for single use only. Anything else constitutes improper use. Filtrate vessel Sample diafiltration reservoir (VFA006) Pink flow restrictor Diagram 1: Vivaflow 50 set up Single module 1. Set up the system as illustrated in Diagram 1. Note the positioning of the flow restrictor on the return line. 2. Vivaflow membranes contain trace amounts of glycerine and sodium azide. To remove these chemicals and to check the security of the tube connections, it is recommended to rinse the module, and to test the system at full pressure before introducing the sample. 3. Place 500 ml deionised water in a suitable reservoir. The Vivaflow sample diafiltration reservoir (prod. no. VFA006) is recommended. 4. Pump liquid through the system to purge any air pockets. The recirculation rate should be in the range 200 400 ml/min, and suitable flow should exit the filtrate line. If used, the pressure indicator (prod. no. VFA020), should read approximately 2.5 bar. 5. Allow 400 ml to pass into the filtrate vessel. Check for any leakage at tubing connection points. Drain the system and empty or replace the filtrate vessel, (see recovery section). The system is now ready for use. 3

T-connector Interconnector Pressure indicator Diagram 2: Setting up multiple Vivaflow 50 cassettes Linked modules 1. Set up the system as illustrated in Diagram 2. Link the required number of modules by sliding the tongue and groove edges together. Note the positioning of the flow restrictor on the return line. 2. Use series interconnectors, (prod. no. VFA031), to connect a single row of modules. Detailed ordering information for system components to be found of page 7, Diagram 4. 4. The flow path of the system can be configured to suit the membrane sample combination. Most solutions are better suited by modules connected in parallel. Very low viscosity solutions favour modules connected only in series. Rinse the system as detailed under single module operation. 3. In addition, use T-connectors, (prod. no. VFA030), to connect two rows of modules in parallel. 4

Diagram 3: Buffer exchange diafiltration with Vivaflow 50 Diafiltration Desalting 1. Set up the system as illustrated in Diagram 3 for linked modules. If only one module is required, connect it in place of the linked modules. 2. Rinse the system as detailed previously. 5. As the volume in the 500 ml reservoir decreases, the vacuum created draws exchange solvent through the feed line from the larger reservoir. Over 99% solvent exchange can be accomplished with an exchange volume approximately 5 times the volume of the sample. 3. Either place the solution to be purified in the 500 ml sample diafiltration reservoir (prod. no. VFA006), or concentrate a larger volume to 500 ml or less so that it is fully contained in the 500 ml reservoir. Ensure the reservoir lid is firmly closed. 4. Fill a large feed reservoir with exchange solvent and pump sample through the system as for concentration. 5

Concentration 1. Fill the feed reservoir with sample solution. When initial volumes larger than 500 ml are required, place 500 ml in the sample diafiltration reservoir, the remaining volume in another suitable container and connect the vessels as detailed in the diafiltration section. Alternatively, use a larger container for the entire sample volume and immerse the feed and return lines directly into the liquid. 2. Pump liquid through the system. The recirculation rate should be in the range 200 400 ml/min, and suitable flow should exit the filtrate line. If used, the pressure indicator, (prod. no. VFA020), should read approximately 2.5 bar. Recovery 1. Disconnect the feed line from the lid of the 500 ml reservoir or when using a different container, remove the feed line from the sample. 2. Pump residual system volume back into the reservoir container. (When parallel modules are used with viscous solutions, ensure that all modules are empty by pinching the tubing between each of the stacks of modules in turn). 3. For a more complete sample recovery rinse approximately 5 10 ml per module of water or sample buffer through the system, and recover as before. 3. Concentrate the sample to the desired volume.! Warning: Do not run the same section of tubing through the pump head for longer than six hours, over use of tubing will result in significant pressure drop and ultimately, failure. 4. When the desired volume has been reached, reduce the recirculation rate to 20 40 ml/min and recirculate the concentrated sample for 1 2 minutes to maximise recovery. 6

System Components Pink flow restrictor on the return line Inconnectors (Prod. No. VFA031) Pressure Indicator (Prod. No. VFA020) Stand (Prod. No. VFA016) T-Connectors for running 2 stacks (Prod. No. VFA030) Masterflex easy load pump head (Prod. No. VFA012) Masterflex pump CE 230V US 115V (Prod. No. VFP001 VFP002) Diagram 4: System componets for setting up multiple Vivaflow 50 units Table 1: Technical Specifications Dimensions Overall L H W 107 84 25 mm Channel W H 15 mm 0.3 mm Active membrane area 50 cm 2 Hold up volume (module) 1.5 ml Min recirculation volume < 10 ml Non recoverable hold-up < 0.5 ml Operating Conditions Pump flow Maximum pressure Maximum temperature 200 400 ml/min 3 bar (45 psi) 60 C 7

Materials of Construction Main housing Flow channel Membrane support Seals and O rings Pressure indicator Flow restrictor Fittings Tubing Polycarbonate TPX (PMP) TPX (PMP) Silicone Polypropylene, SS Spring, Polypropylene Nylon PVC (medical grade) Table 2: Performance characteristics Time to concentrate up to 20x (min.) at 3 bar inlet pressure, 20 C Single Three Solute Recovery % Device Devices 250 ml Start 1 L Start Direct 10 ml rinse Vol. min. Vol. min. BSA 1.0 mg/ml (66,000 MW) 5,000 MWCO PES 34 49 96% > 99% 10,000 MWCO PES 22 32 94% > 99% 30,000 MWCO PES 22 32 92% 99% 50,000 MWCO PES 20 29 92% 98% γ Globulins 1.0 mg/ml 100,000 MWCO PES 43 62 92% 98% 100,000 MWCO RC 40 58 92% 98% 100,000 MWCO Hydrosart 40 58 92% 98% Yeast 1.0 mg/ml (S.Cerevisiae) 0.2 µm PES 33 47 92% 98% 8

Ordering Information Vivaflow 50 include filtrate tube, size 16 peristaltic tubing, Pack Size Prod. No. flow restrictor and fittings and 1 + Series Interconnector 3,000 MWCO (PES) 2 VF05P9 5,000 MWCO (PES) 2 VF05P1 10,000 MWCO (PES) 2 VF05P0 30,000 MWCO (PES) 2 VF05P2 50,000 MWCO (PES) 2 VF05P3 100,000 MWCO (PES) 2 VF05P4 0.2 µm (PES) 2 VF05P7 100,000 MWCO (RC) 2 VF05C4 Vivaflow 50 complete system comprises Pump (240 V), easy load pump head (size 16), tubing, 1 VFS502 500 ml sample diafiltration reservoir, module stand, pressure indicator, T connectors, series interconnectors Pump (115 V), easy load pump head (size 16), tubing, 1 VFS504 500 ml sample diafiltration reservoir, module stand, pressure indicator, T connectors, series interconnectors Vivaflow 50 PVC tubing and fittings Size 16 PVC pump tubing (3 metres, 3.2 +1.6 mm) Flow restrictor set (2+0.4, 0.6, 0.8 mm) T connectors for running 2 stacks (2 pieces) Series interconnectors (6 pieces) Female luer fittings (10 pieces) VF50 tubing kit (2+1 m size 16 PVC tubing with inlets fittings, 2+50 cm size 16 PVC tubing with 0.6 mm flow restrictors, 1+ series inlet connections) Flow restrictor 0.6 mm (6 pieces) VFA004 VFA009 VFA030 VFA031 VFA032 VFA034 VFA035 Vivaflow 50 accessories Masterflex economy drive variable speed peristaltic pump (230 V) VFP001 Masterflex economy drive variable speed peristaltic pump (115 V) VFP002 500 ml sample and or diafiltration reservoir VFA006 Masterflex easy load pump head size 15 VFA013 Masterflex easy load pump head size 16 VFA012 Vivaflow 50 stand VFA016 Pressure indicator (1 3 bar) VFA020 9

Table 3: Chemical Compatibility for the Vivaflow 50 Solution PES RC Acetic acid (25%) OK OK Acetone NO NO Ammonium hydroxide (5%) OK OK Ammonium sulfate sat. OK OK DMEM OK OK Ethanol (70%) OK OK Ethyl acetate NO NO Formaldehyde (30%) OK OK Formic acid (5%) OK OK Guanidine HCl (6 M) OK OK Hydrocarbons, Aromatic NO? Hydrocarbons, Chlorinated NO NO Hydrochloric acid (1 M) OK NO Isopropanol NO NO Lactic acid (5%) OK OK Mercaptoethanol (10 mm) OK OK Methanol (60%) OK OK n-butanol (70%) OK OK Solution PES RC Peracetic acid (0.2%) OK OK Phenol (1%) OK? Phosphate Buffer (1 M) OK OK Pyridine NO NO RPMI-1640 OK OK Sodium azide OK OK Sodium deoxycholate (5%) OK OK Sodium hydroxide (1 M) NO NO Sodium hydroxide (0.1 M) NO NO Sodium hypochlorite (0.02%)?? Sodium nitrate NO NO Sulfamic acid (5%) OK NO Surfactants (0.1%) OK OK Toluene NO NO Trichloroacetic acid (10%) NO? Trifluoroacetic acid (10%) OK NO Urea (8 M) OK OK OK = Acceptable? = Questionable NO = Not recommended 10

Vivaflow 50R and Vivaflow 200 Diagram 5: Vivaflow 50R and Vivaflow 200 set up Operation Single Vivaflow 50R or Vivaflow 200 Modules Assembly and rinsing single module 1. Set up the system as illustrated above in Diagram 5.. Note the positioning of the flow restrictor on the return line. A set of flow restrictors of different gauges (Product No. VFA009), is available for use with solutions of unusually high or low viscosity.! Warning: Ensure Luer connections are secure before operation. 2. Vivaflow membranes contain trace amounts of glycerine and sodium azide. To remove these chemicals and to check the security of the tube connections, it is recommended to rinse the module, and to test the system at full pressure before introducing the sample. 4. Pump liquid through the system to purge any air pockets. The recirculation rate should be 200 400 ml/min, and suitable flow should exit the filtrate line. If used, the pressure indicator should read approximately 2.5 bar. 5. Allow 400 ml to pass into the filtrate vessel. Check for any leakage at tubing connection points. 6. Drain the system and empty or replace the filtrate vessel (see Recovery section). The system is now ready for use. 3. Place 500 ml deionised water in a suitable reservoir. 11

Diagram 6: Setting up two Vivaflow 50R units Operating two Vivaflow 50R or two Vivaflow 200 Modules Assembly and rinsing two modules 1. Set up the Vivaflow 50R system as illustrated in Diagram 6 and the Vivaflow 200 System as illustrated in Diagram 7 system as illustrated above.! Warning: Ensure Luer connections are secure before operation. 2. Vivaflow 50R: Use two T-connectors (VFA030) to connect to the inlets of both Vivaflow 50R modules. Vivaflow 200: Use the Y-connector, (VFA005) to connect to the inlets of both Vivaflow 200 modules. The size 15 tubing connected to the Y-connector is the inlet tubing for the pump. Use a size 15 pump head. 12

Diagram 7: Setting up two Vivaflow 200 units 3. Note the positioning of a flow restrictor on the return line from each Vivaflow 200 module. Vivaflow membranes contain trace amounts of glycerine and sodium azide. To remove these chemicals and to check the security of the tube connections, it is recommended to rinse the module, and to test the system at full pressure before introducing the sample. 6. Allow 800 ml to pass into the filtrate vessel. Check for any leakage at tubing connection points. 7. Drain the system and empty or replace the filtrate vessel (see Recovery section). The system is now ready for use. 4. Place 1 litre of deionised water in a suitable reservoir. 5. Pump liquid through the system to purge any air pockets. The recirculation rate should be 500 900 ml/min, and suitable flow should exit the filtrate line. If used, the pressure indicator should read approximately 2.5 bar. 13

Concentration 1. Fill the feed reservoir with sample solution. 2. Pump liquid through the system. The recircu lation rate should be 200 400 ml/min, (500 900 ml/min for two modules), and suitable flow should exit the filtrate line. If used, the pressure indicator should read approximately 2.5 bar.! Warning: Do not run the same section of tubing through the pump-head for longer than 6 hours, overuse of tubing will result in significant pressure drop and ultimately, failure. Diagramm 8: Buffer exchange Desalting with Vivaflow 50R and Vivafow 200 Diafiltration Desalting 1. Set up the system as illustrated in Diagram 8. 2. Rinse the system as detailed previously. 3. Place the solution to be purified in a suitable diafiltration reservoir. For volumes up to 500 ml the Vivaflow 500 ml sample diafiltration reservoir (VFA006), is recommended. Ensure the lid is firmly closed. 4. Fill the large feed reservoir with exchange solvent and pump sample through the system as for concentration. 3. Concentrate the sample. 4. When nearing the desired volume, reduce the recirculation rate to 20 40 ml/min and recirculate the concentrated sample for 1 2 minutes to increase sample recovery. Recovery 1. Remove the feed line from the sample. 2. Pump residual system volume back into the reservoir container. 3. For a more complete recovery, rinse 25 50 ml of water or sample buffer through the system, and recover as before. 5. As liquid passes through the membrane, the vacuum created in the diafiltration reservoir draws in exchange solvent through the feed line from the large reservoir. Over 99% solvent exchange can be accomplished with an exchange volume of approximately 5 times the sample volume. 14

Table 4: Technical specifications Vivaflow 50R and Vivaflow 200 Dimensions Vivaflow 50 R Vivaflow 200 Overall L H W 100 100 24 mm 126 138 38 mm Channel W H 7.5 0.4 mm 10 mm 0.4 mm Active membrane area 50 cm 2 200 cm 2 Hold up volume (module) 1.7 ml 5.3 ml Min. recirculation volume 10 ml < 20 ml Non recoverable hold-up < 0.5 ml < 1 ml Materials of construction Vivaflow 50R and Vivaflow 200 Main housing Acrylic Flow channel Acrylic Membrane support Polypropylene Seals and O rings Silicone Pressure indicator Polypropylene, SS spring Flow restrictor Polypropylene Fittings Nylon Tubing PVC (medical grade) Operating conditions Vivaflow 50R and Vivaflow 200 Pump flow 200 400 ml/min Maximum pressure 4 bar (60 psi) Pressure drop across inlet outlet 0.5 bar (7 psi) Maximum temperature 60 C 15

Cleaning and storage information only for Vivaflow 50R and Vivaflow 200 Cleaning Vivaflow 50R and 200 modules may be used several times if cleaning and storage instructions are followed. 1. Flush the system with 200 ml of deionised water with the filtrate going to waste. Storage To store Vivaflow 50R and Vivaflow 200 after cleaning, fill module with deionised water and 10% ethanol. Seal inlet, outlet and filtrate ports and refrigerate at approximately 4 C. 2. Place the feed, return and filtrate lines in a suitable container for the cleaning solution. 3. Prepare cleaning solutions suitable for the membrane. I. Polyethersulfone membranes: 250 ml of 0.5 mm NaOCl in 0.5 M NaOH II. Hydrosart membranes: 250 ml of 0.5 M NaOH 4. Recirculate at 50 100 ml/min for 30 40 minutes. 5. Drain the system and recirculate 250 ml of deionised water through the system for 5 10 minutes. 6. Drain and discard rinse solution and flush with a further 500 ml of deionised water with the filtrate going to waste. The system is now ready for further use. 16

Table 5: Performance characteristics Vivaflow 50R Time to concentrate up to 20x (min) at 3.0 bar inlet 2.5 bar outlet pressure, 20 C start volume Average flux Recovery % 250 ml ml/min Direct 25 ml rinse Lysozyme 0.25 mg/ml (14,000 MW) 5,000 MWCO Hydrosart 70 3.4 96% 98% 10,000 MWCO Hydrosart 23 10.3 94% 96% BSA 1.0 mg/ml (66,000 MW) 10,000 MWCO Hydrosart 24 9.9 98% > 99% 30,000 MWCO Hydrosart 15 15.8 97% > 99% γ Globulins 1.0 mg/ml (150,000 MW) 100,000 MWCO Hydrosart 46 5.2 97% > 99% Start volume 1 litre (one Vivaflow 50R at 3 bar) 10,000 MWCO Hydrosart BSA 1.0 mg/ml 95 10.0 98% > 99% Start volume 1 litre (two Vivaflow 50R in parallel at 3 bar) 10,000 MWCO Hydrosart BSA 1.0 mg/ml 48 19.8 98% > 99% 17

Table 6: Performance characteristics Vivaflow 200 Time to concentrate up to 20x (min.) at 3 bar inlet pressure, 20 C start volume Average flux Recovery % 1 litre ml/min Direct 25 ml rinse Lysozyme 0.25 mg/ml (14,000 MW) 2,000 MWCO Hydrosart 160 6 97% > 99% 3,000 MWCO PES 180 5 97% > 99% BSA 1.0 mg/ml (66,000 MW) 5,000 MWCO PES 29 33 98% > 99% 5,000 MWCO Hydrosart 70 14 98% > 99% 10,000 MWCO PES 23 41 96% > 99% 10,000 MWCO Hydrosart 35 27 98% > 99% 30,000 MWCO PES 25 38 96% 99% 30,000 MWCO Hydrosart 20 48 96% > 99% 50,000 MWCO PES 22 43 96% 98% γ Globulins 1.0 mg/ml (average 160,000 MW) 100,000 MWCO PES 54 18 96% 99% Yeast 1.0 mg/ml (S. Cerevisiae) 0.2 µm PES 11 86 92% 98% Dilute solute concentration, start volume 1 litre at 3 bar, 10,000 MWCO PES BSA 0.001 mg/ml 18 52 90% 98% BSA 0.01 mg/ml 20 47 92% 98% BSA 0.1 mg/ml 21 45 94% 99% Start volume 5 litres (two Vivaflow 200 in parallel at 3 bar) 10,000 MWCO PES BSA 1.0 mg/ml (66,000 MW) 67 70 97% > 99% 18

Ordering Information Vivaflow 50R modules include pressure indicator, flow restrictor Qty per Prod. no. and size 16 pvc peristaltic tubing and fittings box 5,000 MWCO Hydrosart 1 VF05H1 10,000 MWCO Hydrosart 1 VF05H0 30,000 MWCO Hydrosart 1 VF05H2 100,000 MWCO Hydrosart 1 VF05H4 Vivaflow 200 modules include pressure indicator, flow restrictor Qty per Prod. no. and size 16 pvc peristaltic tubing and fittings box 3,000 MWCO PES 1 VF20P9 5,000 MWCO PES 1 VF20P1 10,000 MWCO PES 1 VF20P0 30,000 MWCO PES 1 VF20P2 50,000 MWCO PES 1 VF20P3 100,000 MWCO PES 1 VF20P4 0.2 µm PES 1 VF20P7 2,000 MWCO Hydrosart 1 VF20H9 10,000 MWCO Hydrosart 1 VF20H0 30,000 MWCO Hydrosart 1 VF20H2 100,000 MWCO Hydrosart 1 VF20H4 Vivaflow 50R 200 complete system comprises Pump (240 V), Easy load pump head (size 16), tubing, 1 VFS202 500 ml sample diafiltration reservoir Pump (115 V), Easy load pump head (size 16), tubing, 1 VFS204 500 ml sample diafiltration reservoir 19

Vivaflow 50R 200 accessories Masterflex economy drive variable speed peristaltic pump (230V) VFP001 Masterflex economy drive variable speed peristaltic pump (115V) VFP002 500 ml sample and or diafiltration reservoir VFA006 Masterflex easy load pump head size 16 VFA012 Masterflex easy load pump head size 15 VFA013 (only for operating two Vivaflow 200) Size 15 pvc pump tubing and Luer fittings (3 m, 4.8 + 2.6 mm) VFA003 Size 16 pvc pump tubing and Luer fittings (3 m, 3.2 + 1.6 mm) VFA004 Flow restrictor set (2 + 0.4, 0.6, 0.8 mm) VFA009 Female luer fittings size 16 (10 pieces) VFA032 Flow restrictors 0.6 mm (6 pieces) VFA035 Female luer fittings size 15 (10 pieces) VFA036 Flow restrictor set (2 + 0.4, 0.6, 0.8 mm) VFA009 Female luer fittings size 16 (10 pieces) VFA032 Flow restrictors 0.6 mm (6 pieces) VFA035 Female luer fittings size 15 (10 pieces) VFA036 Vivaflow 200 tubing and fittings for operation two modules Y connector (size 15 to 2 + size 16, Luer fittings) Masterflex easy load pump head size 15 Vivaflow 50R tubing a fittings for operation of two modules T-Connector VFA005 VFA013 VFA030 20

Table 7: Chemical Compatibility for Vivaflow 50R and Vivaflow 200 Solution PES HY Acetic acid (25%) OK OK Acetone NO NO Ammonium hydroxide (5%) OK OK Ammonium sulfate sat. OK? DMEM OK OK Ethanol (70%) OK OK Ethyl acetate NO NO Formaldehyde (30%) OK OK Formic acid (5%) OK OK Guanidine HCl (6 M) OK OK Hydrocarbons, Aromatic NO NO Hydrocarbons, Chlorinated NO NO Hydrochloric acid (1 M) OK OK Isopropanol NO NO Lactic acid (5%) OK OK Mercaptoethanol (10 mm) OK OK Methanol (60%) OK OK n-butanol (70%) OK OK Solution PES HY Peracetic acid (0.2%) OK NO Phenol (1%) OK NO Phosphate Buffer (1 M) OK OK Pyridine NO NO RPMI-1640 OK OK Sodium azide OK OK Sodium deoxycholate (5%) OK? Sodium hydroxide (1 M) OK OK Sodium hydroxide (0.1 M) OK OK Sodium hypochlorite (0.02%) OK NO Sodium nitrate NO OK Sulfamic acid (5%) OK? Surfactants (0.1%) OK OK Toluene NO NO Trichloroacetic acid (10%) NO OK Trifluoroacetic acid (10%) OK OK Urea (8 M) OK OK OK = Acceptable? = Questionable NO = Not recommended 21

22

23

Sartorius Stedim Biotech GmbH August-Spindler-Strasse 11 37079 Goettingen, Germany Phone +49.551.308.0 Fax +49.551.308.3289 www.sartorius.com Copyright by Sartorius Stedim Biotech GmbH, Goettingen, Germany. All rights reserved. No part of this publication may be reprinted or translated in any form or by any means without the prior written permission of Sartorius Stedim Biotech GmbH. The status of the information, specifications and illustrations in this manual is indicated by the date given below. Sartorius Stedim Biotech GmbH reserves the right to make changes to the tech nology, features, specifications, and design of the equipment without notice. Status: March 2014, Sartorius Stedim Biotech GmbH, Goettingen, Germany Printed in Germany on paper that has been bleached without any use of chlorine W Publication No.: SLU6097-e140308 Ver. 03 2015