ETL listed for installations within 5 ft. (1.5M) of outer edge of water

Similar documents
ETL listed for installations within 5 ft. (1.5M) of outer edge of water

Fiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual

Installation Instructions

TurboDraft Fire Eductor

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

PRE-PURCHASE DECISIONS...1 BEFORE DELIVERY...1

Appendix B Harris County Standard Operating Procedure for Determining In Situ Hydraulic Performance of High Flow Rate Bioretention Media

Bermad Pressure Reducing. Model: 42T

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Pool Name Length Width Lineal Ft. Gallons Weight $ Price $

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Dry Hydrants. The installation of a non-pressurized pipe system into local water sources provides a ready means of supplying water to fire engines.

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS & PRODUCT MANUAL CMP SERIES

Halsey Taylor Owners Manual STOP!

LoneStar Fiberglass Pools. Do-It-Yourself. Installation Manual

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions

kēlo LED Light Installation Instructions

Winter Shut Down Procedure

START UP MANUAL MADE IN USA REV US and Foreign patents and patents pending see

Basic layout 2016 IRRIGATION-MART. Check (Non- Leak) Valve. Friction Fit. Sprinkler. Figure 1 - Hanging Sprinkler & Check Valve Assembly

Installing ASI Umbilical Delivery Systems

MDX² INSTALLATION MANUAL (RETROFIT FIBERGLASS, VINYL & CONCRETE POOLS WITH MDX)

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

Air Intake Snorkel Kit

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Hydraulic Punch Drivers

FNFB-30 (30 FT FIELDPRO FOOTBALL BACKSTOP SYSTEM) Installation Instructions

Operation Manual. Carbon Filtration Industrial Drive, Orlinda, TN fax

FITNESS, SAFETY & MEDICAL SUPPLIES

icon i150 / i350 Installation / Operation Manual

GREIG FILTERS, INC. OPERATION MANUAL

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

Swimming Pool Requirements

COUNTER CURRENT UNIT. Instruction Manual

W A S T E W A T E R T R E A T M E N T S Y S T E M S

ARCHITECTURAL GUIDELINES FOUR-PIECE COMMERCIAL

ARCHITECTURAL GUIDELINES 1000 S

Cozumel Turbodraft. Operational Considerations

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

Nicheless LED Lighted Bubbler

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

Blue Points 1 ¼ WELL POINT INSTALLATION INSTRUCTIONS

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS CMP SERIES. Brilliant Wonders LED BUBBLERS

Pure Water Power Purification System 4-Stage RODI Operations Manual

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

Model 420-HY Pressure Regulating Hydrant Valve

WATERFALLS DECK JETS SCONCES. Waterfall, - Cut the waterfall notch in the inner edge of the bond beam at the stee tive cover nd protec a

SEP 100 D.E. SEPARATION TANK

Jet Swim Installation instruction

ARCHITECT GUIDELINES 1000 T

ARCHITECTURAL GUIDELINES ONE-PIECE COMMERCIAL

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

FUEL PUMP UPGRADE KIT INSTALLATION INSTRUCTIONS PART NUMBER R

PO Box 1130 Ballston Lake, NY Tel. : (518) Fax: (518) Pool Skimmer

Waterblade Installation Manual

WW-730. Pressure Sustaining/Relief Control Valve

Installation Manual. Model # SF-3W 9/16/03 REV 1. Arch Chemicals, Inc Lower River Road. P.O. Box 800 Charleston, TN PULSAR

Supplementary Operation, Assembly, Maintenance Manual for F3-42 model and optional attachments

TurboDraft. Fire Eductor Operating Instructions.

BS Series Basket Strainer

Discharge Relief Valve Operation & Maint.

Crystal Spring Feeder Protocols

MANUAL BE SERIES Test Benches

LAZY RIVER 3 3 PUMP LOCATION

Installation and Use Manual

Installation and Operation Instruction Manual INSMAN-200. Industrial Sand Media And Deep Bed Sand Media Filters

Office Use Only Fee Paid

PAGE (Rev. A - 06/17)

Swimming Pools, Hot Tubs and Spas

Guide of the BrickIt balloon system for LEGO Blimps

Accu-Tab PowerBase 3070AT by Axiall Corporation

Irrigation System Winterization and Pressurization Procedures

RESIDENTIAL SWIMMING POOLS AND SPAS A GUIDE FOR HOMEOWNERS

SHEER DESCENT & WATERFALL SPILLWAYS

SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

ARCHITECTURAL GUIDELINES FOUR-PIECE RESIDENTIAL

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

Pressure Compensating (PC) Spray Stakes

SWIMMING POOL REQUIREMENTS

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12)

Booster Pump PB4-60 Replacement Kits

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

HIGH RATE BASKET STRAINER

Instructions for SILEX 1C Mixed bed cartridge filter

Side-of-Pole Mount for 1 Module (SPM1) For Module Types A & B

RESIDENTIAL SWIMMING POOL REQUIREMENTS

PRO SINK -R 1 and 2. Dilution system CONTENTS

NOTICE WARNING MDX-R3 FOR FIBERGLASS POOLS OWNER S MANUAL AND INSTALLATION GUIDE SUBMERGED SUCTION OUTLET FOR MULTIPLE DRAIN USE FOR USE ON FLOOR

SKIMMER FOR CONCRETE POOLS OWNER S MANUAL AND INSTALLATION GUIDE

To purchase replacement parts and accessories, or to obtain technical assistance, visit:

FloWash. Industrial Filter Cart

SKIMMER FOR CONCRETE POOLS OWNER S MANUAL AND INSTALLATION GUIDE

Multi-Probe Sampling System User Guide & Manual

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Above Ground Pool In-Stock Pool Sale

LINDGREN-PITMAN, INC. LS-3 / LS-4 Line Setter

WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.

Installation and Operation Manual. Jandy Fiberglass Sand Filters. JS Series Sidemount Sand Filters WARNING

Transcription:

Fiberstars Light Streams Mini Laminar Installation Manual (LSML) 3072091 ETL listed for installations within 5 ft. (1.5M) of outer edge of water 79-15056-00 Rev. A Page 1 of 6

SAVE THESE INSTRUCTIONS! These directions are provided to ensure the proper installation and operation of Fiberstars Light Streams Mini Laminar flow fountain. The maximum lighted distance of the laminar stream should be considered 3ft height and 5ft in distance. If the laminar arc is over the recommended distance, there is a high degree of probability that the lighting will not travel the full distance to the bottom of the laminar flow. Also, if the throw distance is over the recommended distance, the lighting will also fail to go the full distance of the laminar stream. IMPORTANT: Read and follow all safety and installation instructions carefully. The product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and hazard involved. IMPORTANT GENERAL SPECIFICATIONS: 1. The water supply to the Light Streams Laminar fountains should be filtered with a cartridge filter. Sand filter and DE filters will likely produce small particles of debris that will clog the filter screens internal to the laminar flow fountains. 2. Water supply is dependent upon 3 important factors: a. Pump size if dedicated pump is used it must be a minimum of a ½ hp and supply proper flow rate at 16 ft of head. b. Plumbing pipe size c. Number of laminar flow fountains on system NOTE: GENERAL RULE OF THUMB IS THAT EACH MINI LAMINAR REQUIRES A MINIMUM OF 5 GPM. SEE FOLLOWING SECTION ON DESIGN CRITERIA THE LAMINAR FLOW DECK BOX IS MADE OF ABS MATERIAL. USE ONLY ABS-PVC GLUE WHEN MAKING ANY PLUMBING CONNECTIONS TO THIS DECK BOX 3. Each Fiberstars Light Streams Mini Laminar flow fountain requires 12VAC. Minimum sized conduit is 3/4. Run the supplied 100ft of 12VAC wire from the Light Streams LED driver through the conduit back to the location of your transformer (not included). 79-15056-00 Rev. A Page 2 of 6

4. Fiberstars Light Streams Mini Laminar flow fountains can be placed in most locations from concrete decks, raised bond beams or even soft scapes. Be sure that the distance from the interior pool wall to the mini laminar flow fountain is no further than 2 feet. This would allow the lighted laminar flow stream to be 3 feet into the pool interior. 5. Each fountain requires a 1 PVC water supply that is reduced to 3/4 to connect to the bottom of the deck box. 6. Each mini laminar should also have a gate valve installed for flow adjustment. All gate valves should be located as close as possible to the equipment pad area to reduce water turbulence from entering the mini laminar fountain. 7. On main water supply line install a check valve. 8. A plumbing loop should be utilized. Recommended Plumbing Schematic INSTALLATION OF THE MINI LAMINAR FLOW DECK BOX 1. Reconfirm that fountain is no further than 2 feet away from water surface interior. 2. Prepare location by digging hole 2 feet in diameter and depth. A. For in deck applications Level the lid to the finished grade level of decking. B. For planter areas Laminar lid should be 2 inches ABOVE the landscape area to prevent materials from intruding or washing into the fountain itself. 3. Remove the laminar flow fountain from the deck box assembly and undo the hose connection at the bottom of the fountain. 4. Plug hose (with included plug), utilizing stainless steel clamp for pressure testing. 5. Place the deck box into the excavated hole with the drain stand pipe pointing in the direction of the desired water flow (towards pool interior). This will place the water connection at the very rear of the Laminar, opposite of the pool wall. 6. The bottom of the deck box can be supported by utilizing the 1 PVC support connection. The support pipe should be approximately 4 in length. You may also support the deck box to any decking rebar to help maintain the proper level by using the rebar support (4) wings in deck box. 7. Attach the 1 PVC water supply line to the reduced ¾ water inlet connection. 79-15056-00 Rev. A Page 3 of 6

8. Install 3/4 PVC pipe for 12VAC cable run. 9. Install 1 PVC pipe for drain line connection. IT IS IMPERATIVE THAT ALL MINI LAMINAR FLOW FOUNTAINS HAVE PROPER DRAINAGE. 10. Fill excavated area with gravel until gravel reaches approximately 1 up on bottom of deck box. 11. Finish your deck material installation making sure that the Light Streams Mini Laminar flow fountains remain level. Utilizing the 3 Adjustable Deck Flange adjust to match your deck height. After deck box has been installed and system has been pressure tested, the mini laminar flow fountain itself may be reinstalled. IT IS EXTREMELY IMPORTANT THAT THE WATER SUPPLY TO EACH MINI LAMINAR IS ALLOWED TO BE FLUSHED SO THAT ALL MATERIAL THAT MIGHT BE IN THE LINES ARE BLOWN FREE PRIOR TO BEING REINSTALLED INTO THE LAMINAR FLOW DECK BOX. ADJUSTING WATER FLOW The water flow is determined by two factors: GPM water flow and angle of laminar. Set angle of your laminar flow by using the two adjustment knobs on the inside the deck box on either side of the laminar. Adjust your distance by opening or closing each respective gate valve until the desired distance is achieved. MAXIMUM HEIGHT IS 3 OVER POOL WATER LEVEL AND DISTANCE IS 5 FEET. Initial start up should be done gradually, allowing each mini laminar to fill with water slowly and allowing air to escape. Failure to do so may cause damage to unit and plumbing. DO NOT EXCEED 15 GPM PER MINI LAMINAR OR DAMAGE CAN BE DONE INTERNALLY. IMPORTANT NOTES AND REMINDERS Minimize the number of plumbing fittings in the water run to cut down flow restrictions and water turbulence. Laminar flow fountains are susceptible to wind conditions and the higher the angle of your fountain the more they may be effected. If your area has regular amounts of high 79-15056-00 Rev. A Page 4 of 6

winds you may consider moving the laminars closer to the pool edge and decreasing the angle of the fountain. FOR WINTERIZATION, LOOSEN STAINLESS STEEL CLAMP ON WATER SUPPLY HOSE, REMOVE HOSE FROM BARBED FITTING, BLOW WATER LINES CLEAR AND INSTALL PLUG TO SEAL THE WATER HOSE. If internal screens of the Light Streams Mini Laminar become obstructed, this will affect the laminar stream or light output. To correct this, please remove the Light Streams Laminar fountain from the deck box assembly and apply water pressure at the mini laminar fountain exit point. This will back flush the laminar and allow debris to be exited from the bottom. After back flushing, reinstall the Light Streams Mini Laminar fountain and adjust water flow and angle for desired effect. Pipe Size # of Mini Laminars # of units A B C 1 2 3 4 1 1" 1" 3/4" GPM 6 14 24 32 Head (FT) 16 19 26 36 2 1.5" 1" 3/4" 3 2" 1.5" 3/4" 4 2" 1.5" 3/4" C C C C = Optional Valves B Plumbing Loop To Pool By Pass valve Check Valve A Main Supply Line Fiberstars Light Streams Mini Laminar Flow and Plumbing Chart 79-15056-00 Rev. A Page 5 of 6

Rebar Support Wings Mini Laminar Lid Adjustment Knobs LED Driver Light Streams Mini Laminar Deck Box 1 Drain line (Make Sure Faces Water Flow Direction) 3/4 Conduit Figure A 3 Adjustable Height Deck Flange Mini Laminar 3/4 Conduit Fiber Tightening Fitting Barbed Water Supply Fitting 3/4 Water Inlet 10 9 Rebar Support Wing Rebar Support Wing 13 ¾ Water Inlet Figure B ¾ Conduit 1 Drain Lin Figure C 1 Stand Pipe Support 79-15056-00 Rev. A Page 6 of 6