Vapor Intrusion. Sampling Solutions VAPOR INTRUSION. Sampling Solutions

Similar documents
Sorbent Pen Heavy & Labile SVOC s Taints, Off-Flavors, Odors

EAS Basic Soil Gas Sampler

Environmental. Gas Canister sampling and analysis. EQLF, Cambridge, July 20 th Right Solutions Right Partner

DETERMINATION OF TETRAHYDROTHIOPHENE IN AMBIENT AIR BY GAS CHROMATOGRAPHY WITH A PFPD DETECTOR COUPLED TO A PRECONCENTRATION TECHNOLOGY

STANDARD OPERATING PROCEDURES

STANDARD OPERATING PROCEDURES

Super-Clean Gas Filters from Restek

Major Design Features

2 Sentry MCL Installation, Operation & Maintenance

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

STANDARD OPERATING PROCEDURES

Description Advanced Features Typical Applications

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

APPLICATION NOTE. GC Integrated Permeation Device

Avenger Model 33M Installation & Operation Instructions

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Exhibit 4. Determination of Static Pressure Performance of the Healy Clean Air Separator (Executive Orders VR-201-N and VR-202-N)

6890 GC Site Preparation

Supporting Information for Micro-Collection of. Gases in a Capillary Tube: Preservation of Spatial

Tank Blanketing Pressure Regulators RHPS Series

Vapor Sorption Analyzer

CSA Sample Draw Aspirator Adapter Operator s Manual

ATIS OPERATION MANUAL

Versatility. Accuracy. Compact. Versa. Automated Headspace Vial Sampler

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

ISO INTERNATIONAL STANDARD

Oxygen Contamination

VIC offers a variety of Calibrated Gas Leaks

The Principles of Vacuum Technology

The New PHD 4 Portable Helium Detector

INSTALLATION AND OPERATING INSTRUCTIONS

HP/UHP Spring-Loaded Regulator

Precision Pressure Regulators. Precision Fluidics

GILMONT ACCUCAL FLOWMETERS

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER COMPOSITE GAS SAMPLER

AIR DRIVEN LIQUID PUMPS AIR DRIVEN AIR AMPLIFIERS AIR DRIVEN GAS BOOSTERS HIGH PRESSURE VALVES, FITTINGS AND TUBING TEST AND CALIBRATION EQUIPMENT

M-CTE250(T)(i) TM. Micro-Chamber/Thermal Extractor Operator Manual. Version February 2012

INTRODUCTION. The Quantum Technology system has the following advantages:, as it does not need plastic gas-bags which are volume-consuming,

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Full-Vacuum Chlorinator C 2212 MB / 1

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

STANDARD OPERATING PROCEDURES

Best Practice for Identifying Leaks in GC and GC/MS Systems

Methods for Measuring Groundwater Elevation and Vacuum Pressure During Soil Vapor Extraction

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Solid Indicator (Non-mixer) Model CP-30SI

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

B. Assemble the Method-25 sample train with a heated probe/filter.

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Schroeder Check Test Point System

OPERATING INSTRUCTIONS

Basic & Controlled Atmosphere Glove Boxes

11/22/ (4) Harmonization: <846> SPECIFIC SURFACE AREA

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

Instruction Manual Updated 7/26/2011 Ver. 2.2

2 Sentry MVS Installation, Operation & Maintenance

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?

RK-IR Sample Draw Aspirator Adapter Operator s Manual

UT 3000 Mercury Ultratracer

Installation, Operation & Maintenance Manual

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

LGSS Liquefied Gas & VSS Vapor (Gas) LGSS VSS LGSS. Features and Benefits

Technical Bulletin AL-134

RDK-408D2 Cold Head. Technical Manual. SHI-APD Cryogenics Inc Vultee Street Allentown, PA U.S.A. Revision A: September 2005

Specialty Gas Equipment Catalogue

Installation, Operation, and Maintenance Manual

Considerations and Best Practices for Maintaining Your Agilent GC s Split/Splitless Injection Port

Neotecha Tank Sampling Sapro

Installation, Operation & Maintenance Manual

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Manual Solvent Purification System. Innovative Technology, Inc.

Model Description

Residual Gas Analysis Systems for Industry

Flexible Engineered Solutions International CALM Buoy Swivels

Chlorinator MODEL MK-I

Installation, Operation, and Maintenance Manual

Sample C ylinde rs, Acce ssorie s, and O utage Tube s

Demystifying the Process of Calibrating your Thermal Desorption Gas Chromatography System using Compressed Gas Standards.

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Connectors. SECTION 2 OF 3 SECTIONS ON CONNECTORS VHP Tees and Crosses. Top Seller SEE STARRED PRODUCTS. VHP Tees & Crosses for Capillary Tubing

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

Air Quality 2b - PFGC/FID Analysis of Benzene and Toluene in Automobile Emissions

EFFECT OF PACKING MATERIAL AND CONFIGURATION ON ISOLATION VALVE STUFFING BOX LEAKAGE AT CRITICAL OPERATING CONDITION

Compatible with a Wide Range of Gases or Liquids for Laboratory or Plant Applications

Markes Thermal Desorption Systems Site Preparation Page 1 of 8

BIMBAR INFLATABLE PACKERS AND ACCESSORIES

Binks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator)

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

CORESTA RECOMMENDED METHOD Nº 67

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

Valve INV-907. Instructions. 1 Introduction. 2 Installation. Safety. Unpacking. Installing the valve

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

Transcription:

Vapor Intrusion Sampling Solutions VAPOR INTRUSION Sampling Solutions

The All-In-One Soil Gas Sampling Solution Solutions for all 1 2 3 4 ZONES Indoor Air Quality Soil gas levels inside structures. Sub Slab / Vapor Intrusion Reveals the soil gas concentrations right below buildings & potential for vapor intrusion over time. Monitoring Well 4 For measuring soil gas concentrations anywhere in the Vadose Zone. Surface Measurements Determine contamination levels at the surface, or rate of emission from the surface into the air. Vadose Zone Capillary Zone Ground Water Table 1

Advantages of Soil Gas Sampling with Canisters Sampling soil gas into canisters provides significant advantages over the use of passive adsorbent samplers with regard to both maintaining the integrity of the sample in the field and ensuring that the best analytical technique is used in the laboratory. Canisters eliminate the need for pumps, batteries, and media selection, and the same sampling approach can be utilized for any gas concentration while being universal for all compounds. Furthermore, humidity and temperature concerns inherent with tube sampling do not affect canister accuracy. Entech has a long history of engineering turn-key solutions specific to the environments being sampled. Designed with feedback from numerous sampling professionals, the Chameleon provides an all-in-one solution that is changing the way soil gas studies are conducted world-wide. Sampling systems must be considered an extension of the laboratory. The Chameleon improves the accuracy of soil gas sampling by applying basic principles of gas chromatography. Chameleon maximizes recovery while minimizing carryover to yield the most accurate soil gas sample train available. Ensure all surfaces are inert (Entech Silonite coated stainless steel). Minimize surface area and shorten path lengths to canister. Minimize leak prone connections by engineering and machining custom solutions. Eliminate absorption (no plastic tubing where possible). Prove system is leak-tight before delivery to field. Isolate the flow path from the outside world during transportation. The Chameleon Soil Gas Sampling Train One Sample Train for All Soil Gas Sampling Techniques!! Well Monitoring with Gas Shroud Sub-Slab VOC Sampler Active SVOC Sorbent Pen Sampler Dynamic or Static Surface Flux Sampler 2

Sub-Slab & Vapor Intrusion Monitoring No Grout. No Mess. No Contamination. Better Results. Monitor gases directly under the slab of buildings to determine the potential for intrusion into the indoor environment. A vacuum tight seal is made through the building s foundation, with a unique triple seal using two O-rings and a water dam that ensures that only gases from beneath the slab will be drawn into the sample train and canister. After sampling, the slab face sealing fitting is removed allowing a temporary plug to be installed. Chameleon Soil Gas Sampler shown with Entech Sub-Tight Sampler. Advantages: Most reliable, non-contaminating slab vapor seal on the market. Shortest and most inert flow path ensures complete recovery and no sample carryover. Chameleon controls the flow rate to avoid disturbing the equilibrium of VOCs between gas, adsorbed soil, and dissolved water phases. Avoids the use of contaminating plastic tubing. All surfaces are Silonite ceramic lined stainless steel to prevent outgassing of contamination while ensuring maximum compound recovery. Compatible with Entech Soil Gas Shroud for "complete flow path" leak testing right up to the canister. 3

Entech s Slab-Tight Sub-Slab Sampler Complete the Sampling with Chameleon & Silonite MiniCan Face-sealing Bonnet PN SG-SS-Bonnet-QT Entech s unique Slab-Tight sub-slab sampler eliminates interferences created by grout and other slab sealing materials. Grout may contain contaminants that can positively bias the results. Added Down-hole moisture from the grout may affect the solid/liquid/gas phase equilibria. The Entech Slab-Tight sub-slab sampler makes a mechanical connection and seal with no chance of contaminating the collected soil gas. Tracer Gas Shroud for butane or helium leak checking is available. DESCRIPTION PART # Sub-Slab Vapor Intrusion Canister Sampling Kit (50cc/min) SG-SS-50-Kit (600cc, 1L, or 1.4L Cans sold separately) Anchor, Wedge, and Plug Kit SG-SS-AWP-Kit Tool to expand anchor into the concrete SG-SS-Expander Bonnet with QT Fitting SG-SS-Bonnet-QT Bonnet Wrench - Tightens and releases Bonnet to concrete SG-SS-Bonnet-Wrench 50cc/min Chameleon with FQT on Inlet & Outlet SG-CHAM-QQ-050 Down-Hole Gauge for measuring vacuum below ground soil SG-CHAM-DHG 50cc plastic preflush syringe and needle 07-20050 Sub-Slab Vapor Intrusion Canister Sampling Kit (50cc/min) w/ Tracer Gas Shroud (600cc, 1L, or 1.4L Cans sold separately) SG-SS-SHR-50-Kit 50cc/min Chameleon Shroud Sample Train (w/ 3 way valve & magnetic latch) SG-CHAM-TC-050-S Slab PN SG-SS-50-Kit Anchor, Wedge, and Plug Kit SG-SS-AWP-Kit Tool to expand anchor into the concrete SG-SS-Expander Bonnet with QT Fitting SG-SS-Bonnet-QT Bonnet Wrench - Tightens and releases Bonnet to concrete SG-SS-Bonnet-Wrench Down-Hole Gauge for measuring vacuum below ground soil SG-CHAM-DHG 50cc plastic preflush syringe and needle 07-20050 Tracer Gas Shroud for Helium SG-He-Shroud 3-Way, w/ FMQT & 1/8 to 1/4 Tube Adapters SG-SHR-APVI INDIVIDUAL PARTS PN SG-SS-SHR-50-Kit PART # Slab Anchor & Plug Kit - Not reuseable. One needed per installation SG-SS-AWP-Kit Shroud Foam Sealing Ring SG-SHR-RNG Dual Canister Adapter w/ 2 Female Micro-QT Valves 39-99014QT 600mL MiniCan with Micro-QT Valve 29-MC600QT 1L Silonite MiniCan 29-MC1LQT Helium Analyzer (0.1-100%) SG-He-Analyzer Soil Gas Drill Kit SG-SS-DRILL-Kit 4

Tracer Gas Shroud For Vapor Intrusion Helium Source Helium Analyzer Fill to (20%) in Shroud Verify <1% Down-Hole Helium Diffuser He Analyzer Line Out Purge/Helium Monitor Select Valve 1. Pre-Purge/Helium in Soil Gas Test 2. Off 3. Helium Level in Shroud Test Soil Gas Select Valve 1. Pre-Purge/Helium Gas Test 2. Off 3. Sample Chameleon, with 1/4 tube inlet and Compression outlet 50cc/min for Slab-Tight Samplers, 100 to 200cc/min for Permanent Wells 5

Soil Gas with Sorbent Pens SVOC Recovery During Vapor Intrusion Sampling Sorbent Pens are designed to collect VOCs and SVOCs, depending on the adsorbent selected SVOCs will not transfer through lines or come out of canisters quantitatively. The correct adsorbent must be chosen to allow collection and then release by thermal desorption in the laboratory. The Sorbent Pen allows active sampling by connecting the outlet of the Chameleon to an evacuated canister with a restricted flow similar to our CS1200. Active sampling will provide non bias concentrations of PCB, Dioxins, Diesel and other SVOC's in the soil gas matrix. Sub-Slab Vapor Intrusion Semi-Volatiles Sampling Kit For Recovering PCBs, Diesel, and other SVOCs DESCRIPTION PART # Sub-Slab Sampling, 10cc/min with Down-hole Gauge Kit SG-SS-SP-10-Kit (600cc, 1L, or 1.4L Cans sold separately) Anchor, Wedge, and Plug Kit SG-SS-AWP-Kit Sorbent Pen Compatible Bonnet and Water Dam SG-SS-Bonnet-SP Diffusive Air Monitoring Sorbent Pen w/ Tenax TA (35/60) SP-DSP-T3560 10 cc/min Chameleon with Female MQT Inlet/Outlet SG-CHAM-QQ-010 Down-Hole Gauge for measuring vacuum below ground soil SG-CHAM-DHG 50cc plastic preflush syringe and needle 07-20050 INDIVIDUAL PARTS PART # Slab Anchor and Plug Kit - Not reuseable. One needed per installation. SG-SS-AWP-Kit 600mL MiniCan with Micro-QT Valve 29-MC600QT 1L Silonite MiniCan 29-MC1LQT 6

Learn more about us: entechinst.com facebook.com/entechinst twitter.com/entechinst linkedin.com/company/entech-instruments-inc Entech Instruments 2207 Agate Court Simi Valley, CA 93065 Phone: 805-527-5939 Vapor Intrusion Sampling 180131-3.0 2018 Entech Instruments. Silonite, MiniCan, and Slab-Tight are trademarks of Entech Instruments. All Rights Reserved.