O.K. Safety first. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA CDN USA

Similar documents
The installation and maintenance of this product must be done under the supervision of an experienced. Safety first O.K. IFGC CSA UL ANSI NFPA

CSA: Certified File No Never perform work if gas pressure or power is applied, or in the presence of an open flame. Safety first O.K.

CSA: Certified File No Never perform work if gas pressure or power is applied, or in the presence of an open flame. Safety first O.K.

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

The installation and maintenance of this product must be done under the supervision of an experienced. Safety first IFGC CSA UL ANSI NFPA

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Dual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series

Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

Commonwealth of Massachusetts Approved Product Approval code G

SPECIFICATIONS. Normally closed automatic shutoff valve with proof of closure. Fast opening, fast closing. ATTENTION

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure. DMV-ZRD/612 Series DMV-ZRDLE/612 Series

SPECIFICATIONS ATTENTION

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

FRS 7../6 series are CSA Certified: ANSI Z21.80 / CSA 6.22 Class I. Commonwealth of Massachusetts Approved Product Approval code G

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

SPECIFICATIONS CAPACITY

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Dual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

Dual Modular Safety Shutoff Valve with NEMA 4x Enclosure. DMV-D/604L Series DMV-DLE/604L Series

Dual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series

Valve Proving System VDK 200 A S06*

O.K. Safety first USA CDN. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA. MBC-VEF 1000/2500/4000 GasMultiBloc

Line Pressure Regulator. Class I or Class II. FRS 7../6 Series

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

Safety Shutoff Valves MVD/6 Series MVDLE/6 Series

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA. MBC-SE 1000/2500/4000 GasMultiBloc

Butterfly Control Valve. DMK/6 Series

Commonwealth of Massachusetts Approved Product Approval code G

Line Pressure Regulators Class I or Class II. FRS 7../6 Series

Valve Proving System VDK 200 A S02

Gas Appliance Pressure Regulators and. Line Pressure Regulator. FRS 7../6 Series FRS 5... Series

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

SPECIFICATIONS ATTENTION

Gas Pressure Switch for DMV safety shutoff valves

Pressure Switch for gas and air GGAO-A4

Ratio Regulator Zero Governor. FRG/6 Series

Pressure Switch for gas and air

BGA158 Series CE Approved Class A Shutoff Gas Valve

BGA158 Series CE Approved Class B Shutoff Gas Valve

BGA158, BGA171 and BGA110 Series Shutoff Gas Valve

Dual Solenoid Gas Valve Installation

Gas Pressure Switch for DMV safety shutoff valves

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

Pressure switch for gas and air

GM-7000 Series CE Approved Gas Control Valve

BGC258 Series BASOTROL Gas Valve

SPECIFICATIONS FRS. 2 1/2 DN (ISO) Flanged. FRS DN (ISO) Flanged

G96 Series BASOTROL Dual Operator Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

GM Series Dual-Block Multi-Function Gas Control Valves

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G92 Series BASOTROL Automatic Pilot Gas Valve

Gas Pressure Switch for DMV safety shutoff valves

GS-20/25 and GS-40/45 Series Single-block Multi-function Gas Control Valves

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function Gas Control Valves

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Pressure Switch for gas and air

Old documentation - Only for your information! Product is not available anymore!

Safety. Operating instructions Magnetic relief valve VAN DANGER. Contents WARNING CAUTION. Changes to edition 11.11

VMR VMR-OTN VMR 6 bar

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 055 D01

Old documentation - Only for your information! Product is not available any more!

4/2 way Pneumatic Solenoid Valve

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves single-stage atmospheric operating mode GB-(LEP) 057 D01

Old documentation - Only for your information! Product is not available any more!

V5097A-E Industrial Gas Valves

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Integrated gas-air system GB-GD 057 D01

PGM PREPIPED GAS MANIFOLD

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

EVRM-NC EVRM-6NC. delta-elektrogas.com. Safety solenoid valves for gas Manual reset - Normally closed DN10 DN300.

H15 Series BASO 100% Shutoff, Automatic Pilot Valve

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) B01

North American Orifice Metering System

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

36H SERIES Combination Gas Valve

Magnetic level switch type MR783 Instruction Manual

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

Installation Instructions

Inverse Prop. Pressure-Relief Cart., Size 2 4

Safety. Operating instructions Solenoid valve for gas VG 10/15 VG 65 DANGER. Contents WARNING CAUTION. Changes to edition 11.14

V5097A-E Industrial Gas Valves

PRO-50 Instrument Supply Regulator

Proportional Pressure-Relief Cartridge Valve, Size 2...4

V5197A. Firing Rate Gas Valve APPLICATION FEATURES PRODUCT HANDBOOK

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

WhirlWind Combined fully integrated gas/air control and safety system GB-WND 055 D01

Transcription:

HPSV 10020/604 High Pressure Safety Shutoff Valve Installation Instructions USA CDN Table of Contents Table of Contents...Page 1 Approvals...Page 1 Attention...Page 1 Specification...Page 2 Installation Position...Page 3 Mounting....Page 3 Wiring...Page 4 Painting Valve...Page 4 Protection from Radiant Heat...Page 4 Dimensions...Page 5 Valve Leakage Test...Page 6 Flow Curve...Page 7 Accessories & Replacement... Page 8 Approvals CSA Certified: File No. 1010989 ANSI Z21.21 / CSA 6.5 C/I Marking CGA 3.9 Attention The installation and maintenance of this product must be done under the supervision of an experienced and trained specialist. Never perform work if gas pressure or power is applied, or in the presence of an open flame. [V] [A] [Hz] [VA] Check the ratings in the specifications verify sure that they are suitable for your application. 1 8 Explanation of symbols 1, 2, 3... = Action = Instruction Please read the instruction before installing or operating. Keep the instruction in a safe place. You find the instruction also at www. dungs.com If these instructions are not heeded, the result may be personal injury or damage to property. Any adjustment and applicationspecific adjustment values must be made in accordance with the equipment manufacturers instructions. Safety first O.K. IFGC CSA UL ANSI NFPA On completion of work on the safety shutoff valve, perform a leakage and function test. This product is intended for installations covered by, but not limited to, the following fuel gas codes: CSA B149.1 (for Canada), the International Fuel Gas Code, and NFPA 54 or the following equipment codes and standards: CSA B149.3 (for Canada) or NFPA 37. Warning: During normal operation, coil is getting hot. (max. 176 F / 80 C)

Specification HPSV 10020/604 Normally closed automatic shutoff valve. Fast opening, fast closing. [PSI] [V] [A] [Hz] [VA] Max. Operating Pressure 100 PSI (689 kpa) factory rating 60 PSI (413 kpa) as per ANSI Z21.21/ CSA 6.5 C/I and 100 PSI as per CGA 3.9 Burst Pressure Rating 500 PSI (3447 kpa) Electrical Ratings Available 24 VDC Power Consumption 45 W F Ambient / Fluid Service Temperature CSA -20 F to +140 F -29 C to +60 C Factory +5 F to +140 F -15 C to +60 C Storage Temperature -40 F to +185 F -40 C to +85 C NEMA EN 161 Degree of Protection NEMA 4/IP65 Suitable for hazardous locations Class I, Division 2, Groups C and D, Temperature code T4A. Operating Time 100 % duty cycle Closing Time < 1 s Opening Time < 1 s Gas Connection Type 2 flat face flange per ANSI B16.5 Class 150 Gas Gases Dry, natural gas, propane, butane; other noncorrosive gases as well as waste-gases and bio-gases containing up to a maximum 0.1 % by volume (1000 ppm) of H 2 S, dry. Intended for gaseous fuels only. Cannot be used with non-compressible fluids (liquids) of any kind. (A dry gas has a dew point lower than + 15 F and its relative humidity is less than 60 %.) Materials in contact with Gas Housing: Anodized Aluminium and Steel, free of non-ferrous metals Sealings on valve seats: NBR-based rubber. Vibration Resistance According to MIL 810 Profile Vibration Strainer Built-in 1 mm stainless steel mesh strainer, installed upstream of the valve seat. Electrical Connection Quick disconnect according to MIL ACS02A-10SL-04P-003 According to CSA C22.1 Part 1 2 8

Installation Position Installation Position Safety shutoff valve from vertically upright to horizontal. Mounting HPSV 10020/604 Flanged Mounting Procedure 1. Only install the HPSV 10020/604 safety valve downstream of a 50 micron max. gas filter and with the gas flow matching the direction indicated by the arrows on the casting. 2. Mount the HPSV 10020/604 to a flat face B16.5 flange with the solenoid vertical to horizontal. 3. Insert proper flange seal. 4. Insert studs, tighten in a crisscross pattern to ensure uniform tightness. 5. Do not overtighten studs. Follow the maximum torque values listed. 6. After installation is complete, perform a leak test. (see Valve Leakage Test ) A manual shutoff valve and a leak test connection shall be installed downstream of the valve in order to provide for proper valve leakage testing. Stress free assembling! 19 Chrome Steel Made in Germany [Ib-in] 18 Recommended Torque for Studs Studs M16 X 65 mm (DIN 939) T max 1327 [Ib-in] (150 Nm) Recommended Installation Inlet Pressure HPSV 10020/604 Safety Shutoff Valve 50 micron max. gas filter HPSV 10020/604 Safety Shutoff Valve Leak Test Connection Leak Test Connection Manual Shutoff Valve 3 8

Wiring Wiring the HPSV 10020/604 1. Disconnect all power to the leads before wiring to prevent electrical shock and equipment damage. 2. Connect the 24 VDC power to the connector 271568 or a similar one. Connector and valve are not polarity sensitive. 3. Install the connector on the valve 4. The connector and the cable shall be suitable for 24 VDC and capable of at least 2 A and rated for at least 75 Electrical Connection 2 Poles connector type Amphenol ASC02A-10SL-04P-003. Connections are not polarity sensitive. + + All wiring must comply with local electrical codes and regulations. Label all wires prior to disconnection when servicing valves. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. DC No protection elements (diode, fuse, VDR) are implemented in the valve. No rectifier or polarization diodes are applied. There is a direct connection to the solenoid windings. Therefore, the coil is not polarity sensitive. Painting Valve It is not recommended that this valve be painted. Painting covers date codes and other labels that identify this valve. If the valve needs to be painted, a paint free of volitile organic compounds (VOC s) must be used. VOC s can damage valve o-rings, resulting in external gas leakage over time. Protection from Radiant Heat Radiant heat must be considered as a heat source that could result in an ambient temperature higher than the rating of this valve. Note: When installed in hazardous locations, the wiring shall be Ex ia, Ex ib, Ex ic, or Nonincendive field wiring, as defined under the Canadian Electrical Code, C22.1 or the National Electrical Code, NFPA 70. During the painting process, use measures that will allow the valve s date code and other labeling information to be legible after the paint is dry. Provide propor shielding to protect against radiant heat. 4 8

Dimensions c g e Upstream 1/4 NPT Tap Downstream 1/4 NPT Tap a f b d Type Order No. Dimensions [inch] Dimensions [mm] HPSV 10020/604 VIP 270890 2.95 75 a b c d e f g 8.82 224 6.30 160 6.02 153 9.84 250 2.09 53 2.52 64 Weight [lbs] [kg] 13.2 6,0 5 8

Valve Leakage Test This leak test procedure tests the valve seat sealing capabilities of the safety shutoff valve. Only qualified personnel should perform this test. It is required that this test be done on the initial system startup, and then repeated at least annually. Possibly more often depending on the application, environmental parameters, and the requirements of the authority having jurisdiction. Setup This test requires the following: A) Test connection installed downstream of the safety shutoff valve to make the required 1/4 hose connection in step 4. B) A transparent glass of water filled at least 1 inch from the bottom. C) A proper leak test tube. An aluminum or copper 1/4 rigid tube with a 45 cut at the end that is then connected to a 1/4 flexible hose of some convenient length provides for a more accurate leakage measurement. However, a 45 cut at the end of the 1/4 flexible hose will suffice, but it will not likely be as accurate as the rigid tube. Leak Test Procedure Use the illustration below as a reference. 1. Close the downstream manual shutoff valve, or safety shutoff valve. 2. Open the downstream test connection and connect the 1/4 flexible hose. 3. Provide for some time to allow potential leakage to charge the test chamber before measuring valve seat leakage. 4. Immerse the 1/4 in. tube vertically 1/2 in. (12.7 mm) below the water surface. If bubbles emerge from the 1/4 tube and after the leakage rate has stabilized, count the number of bubbles. 5. If the number of bubbles exceeds 6 within 10 s, replace the valve. After completing the above tests proceed as follows: 6. Verify that the downstream manual shutoff valve is closed. 7. Remove the flexible hose, and close the test connection. 1/4 Flex Hose 1/4 Rigid Tube 6 8

Flow Curve Pressure drop for other gases To determine the pressure drop when using a gas other than natural gas, use the flow formula below and f value located in the table below to determine the corrected flow rate in CFH through the valve for the other gas used. For example, when using propane, divide the volume (CFH) of propane required for the application by the calculated value f (f = 0.66 for propane). Use this corrected flow rate and the flow curve on the next page to determine pressure drop for propane. 7 8 Determining equivalent flow through valves using another gas f = V gas used = V Natural gas x f Density of Natural gas Density of gas used Type of gas Density [kg/m 3 ] s.g. Natural gas 0.81 0.65 1.00 Butane 2.39 1.95 0.58 Propane 1.86 1.50 0.66 Air 1.24 1.00 0.80 f

Accessories & Replacement Replacement Coil Valve Type Voltage Order No. HPSV 10020/604 (VIP Coil) 24 VDC 270888 Connector 2 Poles (RoHS) 271568 We reserve the right to make modifications in the course of technical development. Karl Dungs, Inc. 3890 Pheasant Ridge Drive NE Suite 150 Blaine, MN 55449, U.S.A. Phone 763 582-1700 Fax 763 582-1799 e-mail info@karldungsusa.com Internet http://www.dungs.com/usa/ Karl Dungs GmbH & Co. KG P.O. Box 12 29 D-73602 Schorndorf, Germany Phone +49 (0)7181-804-0 Fax +49 (0)7181-804-166 e-mail info@dungs.com Internet http://www.dungs.com 8 8