Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection

Similar documents
Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

Serie 06-M6. Swing wafer check valve. made in. Application fields. Check valves E U R O P E WATER CONDITIONING INDUSTRY

Differential Pressure Control Valve (DPCV)

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

DN 65 to 100 R.F. PN10 flanges + 5 C + 65 C Max Pressure : 10 Bars Specifications : Brass check valve Controlable With valves DN1/2

Description. Functions. Technical data. Applications. Tests. On-Off 2 levels float control valve, closing at high level and opening at low level.

Materials : Carbon steel ASTM A216 WCB

DN 1/2" to 2" Female BSP + 0 C C Max Pressure : 16 Bars Specifications : Stainless steel removable filter Female / Female With draining valve

Materials : Stainless steel ASTM A351 CF8M

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

Materials : Brass body dezincification-resistant up to DN1 1/4

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Flanged pressure reducer/stabilizer VRCD

STAP. Differential pressure controller DN

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron EN GJL 250 body. Reinforced lug for DN200 :

CLASS TLP Pressure Reducing Valve

Wastewater combination air valve in stainless steel AISI 316 Mod. SCS

776 Cryogenic Safety Valve

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

FITTINGS AND VALVES Düker Plunger Valve RKV Type 7015 Professional control of flow rates, reservoir levels and pressures Safe, hygienic and durable!

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Pressure Reducing Valve DMV 750 set range: bar

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

Materials : Brass body dezincification-resistant

ACCREDITED. Technical specifications series

REDUCED PRESSURE ZONE DEVICES SERIES PRODUCT CODES OPERATION HIGH HAZARD RATING. 15mm - 50mm FEATURES APPLICATION DESCRIPTION

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

HYDRAULIC CONTROL VALVES

TEC 1/2 3/ /4 1 1/ /2 3 4 DN A B 125,5 125,

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

CALEFFI. Reduced pressure zone backflow preventer. 574 series 01022/18 NA D E C F B D E. Function

Mounting and Operating Instructions EB 3009 EN. Self-operated Regulators. Type RS Check Valve (backflow protection)

STAP. Differential pressure controllers DN , ANSI flanges

Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN

Installation and operating instructions KEMPER Backflow Preventer BA Figure 361

Pressure Reducing Valve for Steam Type 2333 A

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

TEC 1/2 3/4 DN A B C 32,25 32,25 F Kg/cm 2 bar LBS - psi

Ref GAS WAFER BUTTERFLY VALVE. Model/Ref:

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Art PRESSURE REDUCER

HERZ-Motorised flow controler

AVP-F. p setting range (bar) Code No. 003H6200

DN 3/8" to 4" Female BSP - 10 C C Max Pressure : 16 Bars up to DN 2 Specifications : Removable stainless steel filter Female / Female

Forged stainless steel ASTM A182 F316

756 Safety Relief Valves

Pressure Relief Valve DHV 718

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Type Type Differential Pressure Regulators (opening)

WW-720. Pressure Reducing Control Valve

Pressure reducing valves Index

Pressure independent control valve (PICV) FLOWMATIC

Mounting and Operating Instructions EB 2555 EN. Self-operated Pressure Regulators. Pressure Reducing Valves Type 50 ES Type 50 EM.

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Two-port seat valves

VALVES HIDROMATIC VALVE.

Tank Blanketing Pressure Regulators RHPS Series

Pressure reducing station. ARI-Pressure reducing station, self-acting or with electro-pneumatic control. ARI-PREsys -S. Pressure reducing station

Type overview. R B2 en-gb subject to changes 1

C 10 Pressure Reducing Valve

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

Pressure reducing station. ARI-Pressure reducing station, self-acting or with electro-pneumatic control. ARI-PREsys -S. Pressure reducing station

Overview of types. Technical data. Safety notes

TECHNICAL DATA. Q = C v P S

STAP. Differential pressure controller DN 15-50

2-Port Seat Valves with Flange, PN 16

AIR RELIEF VALVES NETWORK PROTECTION

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

Installation & Operation Manual Proven Quality since 1892

TW Temperature Control Valve

Materials : Forged carbon steel A105N

STAP. Differential pressure controllers DN , ANSI fl anges

Pressure reduction controller (PN 16, 25, 40)

High Performance BSP Dial Up Pattern Pressure Reducing Valve

VB85/ Pressure regulating valve (Unloader)

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves

TECHNICAL DATA. Q = C v P S

Pressure Reducing Valve DMV 750

BCV31 DN20 - Blowdown Control Valve

STAINLESS STEEL LOW PRESSURE REDUCING VALVE LPRV ELITE

BTV. Internally threaded 2-way control valve. Flow characteristics. Function

SV5 Safety Valve Installation and Maintenance Instructions

2-port seat valves PN25 with externally threaded connections

HEAVY DUTY KNIFE GATE VALVE

Telefon (+45) Telefax (+45)

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Seated valves VRB 3, VRG 3

Slam Shut Valves SCN

Si C132. Safety valves for pressure relief in accordance to PED, DIN/EN and ASME. Engineering GREAT Solutions

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

WW-730. Pressure Sustaining/Relief Control Valve

HUPF Series DESCRIPTION APPLICATION INSTRUCTION SHEET GAS PRESSURE REGULATOR WITH INCORPORATED FILTER EN1C-0003NL05 R1205.

Transcription:

Flanged back flow preventer with controllable reduced pressure zone made in Application fields WATER FIRE FIGHTING DRINKING WATER 64 www.brandoni.it

The ECO 3F flanged backflow preventers, which have a controllable reduced pressure zone, type BA EN77, are approved in conformity with EN2729 and are manufactured in accordance with the most severe product norms and in conformity with the quality requirements of EN ISO 900. They consist of 2 spring check valves and a chamber situated between the spring check valves that contain a security valve, which in the event of backflow, isolates the primary network from the user network. The backflow might be caused by siphoning (the entry pressure decreases due to ruptures in the piping upstream, the water supply is interrupted, partially draining parts of the piping, as a result of the events upstream) or by increasing counter pressure (the pressure of the user network is higher than the pressure in the primary network due to overpressure caused, for example, by incoming water pumped from a private water well). Backflow preventers are indispensable to prevent contamination of the distribution network of the drinking water from entering from connected user units (for example, washing machines, boilers, industrial plants, hospitals, laboratories, fire fighting plants). For correct installation, it is necessary to install a filter upstream with respect to the backflow preventer, in order to prevent problems caused by dirt and residual parts present in the piping, such as shut-off valves upstream and downstream with respect to the backflow preventer. Series ECO3F backflow preventer, even if marked PN0 for the purposes of reference normative EN2729, due to its design and testing characteristics is suitable for installation in firefighting networks with service pressure of 2 bar. 2 4 3. Very compact design, one of the smallest backflow preventers, which allows easy installation in limited spaces. 2. Test points fitted with mini-valves, for controlling the absolute and differential pressure in the upstream and intermediate zones. Together with the ECO3 TEST, these allow checking the function of the backflow preventer. 3. Internal and external epoxy coating. 4. Easy maintenance due to removable cover. Accessories Special version ECO3 TEST: control instrument Pre-assembled unit Refer to specifications on page 69 In conformity with EN77, BA type Homologated in accordance to EN2729 Construction and testing norms (correspondences): Flanges: EN 092 Marking: EN9, EN2729 Testing: 00% testing in accordance with EN2729 www.brandoni.it 65

Flanged backflow preventer with controllable reduced pressure zone 4 S.4 S.5 S.2 S. 4 S.3 R2.5 R2.4 R2.7 2 R.6 R.2 R. R.3 R.4 R.5 S.6 S.8 S.0 S. S.7 S.9 3 R2.2 R2. R2.3 R2.6 6 Materials 2 3 4 5 6 R. R.2 R.3 R.4 R.5 R.6 R2. R2.2 R2.3 R2.4 R2.5 R2.6 R2.7 S. S.2 S.3 S.4 S.5 S.6 S.7 S.8 S.9 S.0 S. Component Body Bonnet Bottom cap Cover Valve M/F ½ Drain conveyor Upstream check valve seat Upstream check valve flange Upstream check valve shutter Upstream check valve spring Upstream check valve stem Upstream check valve seal Downstream check valve gasket Downstream check valve plate Downstream check valve shutter Downstream check valve spring Downstream check valve stem Downstream check valve seal Downstream check valve retaining ring Equalizer Equalizer bush Lip seal Membrane Membrane bearing plate Stem Relief valve shutter Relief valve spring Relief valve seat Relief valve ring nut Relief valve seal O-ring Nuts and bolts Material DN 65 DN 80 DN 00 DN 50 EN GJL 250 EN GJL 250 EN GJL 250 AISI 304 Brass Polypropylene PPO Noryl PPO Noryl AISI 302 Silicon rubber POM Delrin AISI 302 Silicon rubber AISI 304 PTFE + carbon NBR EPDM + Nylon AISI 304 PPO Noryl AISI 302 AISI 304 CUZn40Pb2 Silicon rubber NBR AISI 304 66 www.brandoni.it

backflow preventer A W N H H n x D S S2 S3 F C Dimensions (mm) DN 65 80 00 50 A 360 400 450 540 H 200 24 234 259 H 290 34 347 370 N 37 57 63 86 W 89 230 230 276 S/2/3 75/90/20 C EN092 PN0 85 200 220 250 F 60 85 200 20 n x D 4 x 8 8 x 8 8 x 8 8 x 22 Weight (kg) DN 65 80 00 50 kg 30 40 46 73 pre-assembled unit Bv G G Hmax A Dimensions (mm) DN 65 80 00 50 G 95 0 25 70 G 68 95 224 300 Unit with ball valves A 990 070 80 440 Hmax unit 200 24 234 259 Bv 230 280 360 560 kg 65 94 4 27 Unit with butterfly valves DN 65 80 00 50 A 742 802 904 32 Hmax unit 200 29 239 290 Bv 70 206 206 285 kg 5 73 90 60 Unit with gate valves A 990 070 80 440 Hmax unit 247 300 322 408 Bv 60 200 200 250 kg 72 95 8 209 www.brandoni.it 67

Flanged backflow preventer with controllable reduced pressure zone Maximum pressure Temperature Pressure 0 bar Temperature min C Max C 0 65 Head loss Fluid: water (m H2O = 0,098bar) bar.5 DN65 DN80 DN00 DN50 0.5 0 00 mc/h Kv - DN chart DN 65 80 00 50 Kv 64 85 29 235 Minimum flow rate (mc/h) in function of head loss ( accorging to EN 2729:2002 ) DN 65 80 00 50 Head loss bar 35,8 54,3 84,8 90,9 Head loss,5 bar 47,8 72,4 3, 254,5 68 www.brandoni.it

Versions Back flow preventer ECO 3F Homologated EN 2729 Body: EN GJL 250 Temp: 0 +65 C Coating: RAL 5002 colour Accessories ECO 3 TEST Control instrument. Composed of instruments, pre-assembled circuit, accessories for connection to the valve and the instructions for the testing of the correct working of the back flow preventer. Special version Pre-assembled unit Unit composed of 2 shut-off valves (ball valves, butterfly valves or gate valves), filter, back flow preventer VALVE VALVE FILTER BACk FLOW PREVENTER www.brandoni.it 69

Flanged backflow preventer with controllable reduced pressure zone Instruction and Recommendations The information provided here is delivered with each product, and contains Instructions for use and maintenance ; it is also available on our website: www.brandoni.it (download section) OPERATING PRINCIPLE NORMAL OPERATION: REGULAR FLOW Under normal conditions, the relief valve is closed, and the water flows through the 2 check valves (R and R2). Due to the head loss of valve, the pressure in the intermediate section is at least 40 millibar less than the upstream pressure. This difference acts upon the membrane and closes the relief valve. R S R2 NO FLOW: NORMAL PRESSURE The check valves ( and 2) are closed and the relief valve remains closed. BACK PRESSURE: DOWNSTREAM OVERPRESSURE The downstream check valve (R2) closes, preventing potentially contaminated water from flowing into the supply pipe. If the downstream check valve is not perfectly watertight, the polluted water can seep into the central chamber. As the pressure in the central chamber increases, the relief valve opens and the polluted fluid discharges. BACK-SIPHONAGE: UPSTREAM DEPRESSION If the upstream pressure accidentally decreases, the check valves ( and 2) automatically close; so the pressure difference between the upstream section and the central section is reduced; the spring opens the relief valve and the central chamber empties. Consequently, the flow between the upstream area and the downstream area is interrupted, making it completely safe. The empting of the central chamber causes a fall in pressure and brings the valve back to the initial safety conditions. 70 www.brandoni.it

IMPORTANT: PRIOR TO INSTALLATION A correct example of how to install the backflow preventer is shown in Fig. A.. The device must be located in a common, easily accessible area of the building, it must be ventilated and not subject to flooding. (The preventer should preferably be placed outside building works and above the soil). 2. The backflow preventer must be located away from every area that may be flooded, always considering the highest level that water may reach in adjacent areas, in case of frequent flooding. 3. Around the device, there must be enough room to enable easy installation or removal. It must be easily accessible for repair work and working tests. FIG. A CEILING Maximum hight for water mains and drains Drains Water mains 0,5m min 0,5m min Discharge to drains 0,5 -,5m 4. When the device is placed in an installation which FLOOR may pollute the drinking water supply network, all networks supplying sanitary or food processing systems must be installed upstream with respect to the backflow preventer and the downstream network must be marked with the conventional safety signs and colours, in accordance with UNI 5634P regulations. 5. The opening of the relief valve must enable the water to drain off as a result of gravity. 6. When running a test with the ECO3TEST device, pressure gauges must be at the same height as the backflow, to ensure correct measurement by the differential pressure gauge. 7. The discharge device must not give off toxic fumes into the room. The discharged waters must not be harmful to the environment: the health authorities should be consulted in the cases established by the current regulations. 8. The leakage recovery system, located under the bleed valve mouth, and the discharge water recovery works must have a minimum section, corresponding to the following values: DN 65 80 00 50 Internal diameter of drain pipe 75 / 90 / 20 CONVEYOR ASSEMBLY 2 3 /2. Insert the upper cover into the drain conveyor 2 3 3. Fix the cover to the back flow preventer with the plugs included www.brandoni.it 7

Flanged backflow preventer with controllable reduced pressure zone INSTALLATION Follow the directions as shown in Fig B. FIG. B CEILING DRAINS Water mains Discharge to drains FLOOR. Install an interception valve x upstream with respect to the backflow preventer. 2. Install an interception valve y downstream with respect to the backflow preventer. 3. When the valves are closed install a strainer with a bleed plug upstream with respect to the preventer, making sure that water flows in the direction indicated on the body. WARNING The strainer is essential if the preventer is to work properly. Make sure that, during the installation there are no residual parts in the pipes that may serious damage to the device. 4. Install the backflow preventer between the strainer and the downstream valve, always following the direction indicated on the body 5. Close valves -2-3 6. Remove the plastic protection cap located under the bleed valve 7. Fix the bleed pipe 8. Slowly open the upstream valve x 9. Slowly open the preventer valves, in the order 3-2-, from downstream to up upstream; let them bleed, and close 0. Slowly open the downstream valve y. The backflow preventer is now working. Make sure that the relief valve does not leak. In case of leakage, check if there are pressure decreases in the upstream section. 72 www.brandoni.it

MAINTENANCE MAINTENANCE OF THE RELIEF VALVE - Unscrew the cap bolts - Take out and replace the CLOSING DEVICE S S R MAINTENANCE OF THE UPSTREAM - Unscrew the nut and take out the shutter of upstream valve R - Replace the seal R2 MAINTENANCE OF THE DOWNSTREAM - Take out the upstream valve R2 by acting on the elastic ring - Unscrew the nut - Replace the seal SPARE PARTS (CODES) SPARE PARTS ECO3F.065 ECO3F.080 ECO3F.00 ECO3F.50 R K025996C80 K030996C80 K040996C80 K060996C80 R2 K025997C80 K030997C80 K040997C80 K060997C80 Rs K025998C80 K030998C80 K040998C80 K060998C80 Upstream valve seal 02507C70 030078C70 040078C70 06007C70 Downstream valve seal 025078C70 03007C70 04007C70 060078C70 www.brandoni.it 73