Process Dynamics, Operations, and Control Lecture Notes - 20

Similar documents
CONTROL VALVE WHAT YOU NEED TO LEARN?

LABORATORY EXERCISE 1 CONTROL VALVE CHARACTERISTICS

Hydronic Systems Balance

Application Worksheet

INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR NPTEL ONLINE CERTIFICATION COURSE. On Industrial Automation and Control

Pressure Control. where: p is the pressure F is the normal component of the force A is the area

This portion of the piping tutorial covers control valve sizing, control valves, and the use of nodes.

Pumping Systems for Landscaping Pumps, Controls and Accessories. Mark Snyder, PE

Cavitation in Valves

EDUCTOR. principle of operation

Gerald D. Anderson. Education Technical Specialist

The Discussion of this exercise covers the following points:

Tutorial. BOSfluids. Relief valve

International Journal of Technical Research and Applications e-issn: , Volume 4, Issue 3 (May-June, 2016), PP.

Characterizers for control loops

PROCESS MONITORING AND CONTROL

TUTORIAL. NPSHA for those who hate that stuffy word. by Jacques Chaurette p. eng. copyright 2006

Practical Guide. By Steven T. Taylor, P.E., Member ASHRAE

Fundamentals of Hydronic Design. Fundamentals of Hydronic Design. Fundamentals of Hydronic Design. Fundamentals of Hydronic Design

A centrifugal pump consists of an impeller attached to and rotating with the shaft and a casing that encloses the impeller.

VB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions

Modeling a Pressure Safety Valve

Applied Fluid Mechanics

Numerical Simulations of a Train of Air Bubbles Rising Through Stagnant Water

Aspects of Flow Control in Metering Henry Gomes SGS Kuwait WLL

XDF BURNERS DUAL FUEL EXCESS AIR BURNER FEATURES DESCRIPTION EXCESS AIR OPERATION

MODELING AND SIMULATION OF VALVE COEFFICIENTS AND CAVITATION CHARACTERISTICS IN A BALL VALVE

V311. Venta. Three-way Plug Valve, Flanged PN 16

Digital Level Control One and Two Loops Proportional and Integral Control Single-Loop and Cascade Control

VB-7212 Series. Application. Features. Applicable Literature. 5/8" O.D., 45 SAE Flared Stem Up Open, Two-Way Valves General Instructions

TWO PHASE FLOW METER UTILIZING A SLOTTED PLATE. Acadiana Flow Measurement Society

FILTER BYPASS CONTROL

Using the CONVAL software for the petrochemical plant control valves checking. Case study

Pump-Fan-Compressor Sizing

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

Appendix A Frequently Asked Questions

SIZING THE WELL-X-TROL

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

FUNDAMENTALS OF PRESSURE REGULATORS ROBERT BENNETT MANAGER OF TRAINING ELSTER AMERICAN METER

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Wind Regimes 1. 1 Wind Regimes

CONTROL VALVE FROM CONTROL LOOP THEORY PERSPECTIVE: An overview

BACK PRESSURE / SUSTAINING

VB-7211 Series. Application. Features. Applicable Literature. 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions

LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary

Modeling Case Study: Surge Tanks, Valves, Level sensors, and modeling

Comments on Homework. Quiz. Class 3 - Pressure. Atmospheric Pressure. 2. Gauge vs. Absolute Pressure. 1. Definitions. Temperature conversion

Chapter 3: Fluid Statics. 3-1 Pressure 3-2 Fluid Statics 3-3 Buoyancy and Stability 3-4 Rigid-Body Motion

BACK PRESSURE / SUSTAINING

Cover Page for Lab Report Group Portion. Pump Performance

Fail Operational Controls for an Independent Metering Valve

Anemometry. Anemometry. Wind Conventions and Characteristics. Anemometry. Wind Variability. Anemometry. Function of an anemometer:

VBS-9263 Series. Application. Features. Applicable Literature

COMPARING PLUG & SEAT REGULATORS & CONTROL VALVES. Lamar Jones. Equipment Controls Company 4555 South Berkeley Lake Road Norcross, GA 30071

Example: Calculate the density of methane at 50 psig and 32 ⁰F. H.W. In previous example calculate the density of methane in gm/m 3.

The Use of a Process Simulator to Model Aeration Control Valve Position and System Pressure

INTRODUCTION TO REGULATOR AND RELIEF VALVE SIZING. Introduction

Pressure and Flow Control Valves DBGM, German and European Patents

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

Test Report # Rev 0. Adiabatic Compression With Constant Bleed Valve

CASH VALVE TYPE KP BACK PRESSURE VALVES

V43 Pressure Actuated Water Regulating Valve

Smart Water Application Technologies (SWAT)

VB-7213 Series. Application. Features. Applicable Literature. 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions

SINGLE VALVE WITH LOW-FLOW BYPASS

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

OVERVIEW. Flow Coefficient C v. Operating Conditions. Specific Gravity

CHEMICAL ENGINEERING LABORATORY CHEG 239W. Control of a Steam-Heated Mixing Tank with a Pneumatic Process Controller

Seated valve for steam (PN 25)

The Advancement of Pressure Independent Technology

Control Valve : The Final Control Element. Nimish Shah

Comments on Homework. Class 4 - Pressure. Atmospheric Pressure. Gauge vs. Absolute Pressure. 2. Gauge vs. Absolute Pressure. 1.

Valve Sizing Considerations. Steven Hocurscak Metso Automation

RadKits (Piping Packages)

Assistant Lecturer Anees Kadhum AL Saadi

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Balancing HVAC Hydronic Systems Part 3: Flow Measurement Valves

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

second test was conducted using at 3/4inch nozzle to determine a practical maximum pressure for the pump.

Pressure is defined as force per unit area. Any fluid can exert a force

Integrating Aeration Blowers with Most-Open-Valve

Device Description. Operating Information. CP Q (eq. 1) GT. Technical Bulletin TB-0607-CFP Hawkeye Industries Critical Flow Prover

REFERENCE GUIDE. Rev. 0 15/09/2016

Irrigation &Hydraulics Department lb / ft to kg/lit.

****** * EX * ****** DWN W.W.POWELL CALCULATION OF FLOW LOSSES IN INLET CHK D.PAPA AND DISCHARGE HEADERS ASSOCIATED WITH

THE INNER WORKINGS OF A SIPHON Jacques Chaurette p. eng. January 2003

Plant design and control valve selection under increasing cost and time pressure - Part I

Pressure Measurement

Joint Expo 2012 February 7-8, 2012 BASIC HYDRAULICS

VB-7263 Series. Application. Features. Applicable Literature

PURE SUBSTANCE. Nitrogen and gaseous air are pure substances.

Liquid Level Measurement

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

2/2-Way Solenoid Control Valve

Fluid Flow. Link. Flow» P 1 P 2 Figure 1. Flow Model

Old-Exam.Questions-Ch-14 T072 T071

Optimizing Compressed Air Storage for Energy Efficiency

International Research Journal of Electronics and Computer Engineering Vol 1(3) Oct-Dec 2015

Lift for a Finite Wing. all real wings are finite in span (airfoils are considered as infinite in the span)

Balancing Valves. Applications/ Features: Ordering Information: Accessories:

Transcription:

Lesson 0. Control valves 0.0 Context Controller output is a signal that varies between 0 and 100%. Putting this signal to use requires a final control element, a device that responds to the controller output signal by manipulating the process. In chemical processes, this is most often a valve, so that the controller output changes a flow rate. This control valve contributes a gain and requires time 0.1 Construction Control valves are throttling valves, with an automatic actuator. A common design will use air and spring to move a diaphragm, which is connected to the stem, and thus the valve plug (trim). The air pressure varies between 3 and 15 psig to drive the valve through its full range. Fail-open or fail-close may be accomplished with either the actuator design (spring on top or bottom) or the valve body design (relative position of plug and seat ring). Typical applications: open for cooling water; closed for reactants. The example shows a valve that could be called either fail-open or air-to-close. At 3 psig, or 0 psig if the air pressure fails, the valve will be fully open. At 15 psig, the valve will be fully closed. air 0. Flow and head loss through fully-open valves Remember your fluid mechanics: for flow going through some obstruction (such as a pipe fitting or a valve), we relate the friction loss to the flow rate by a resistance coefficient, or a loss coefficient. For turbulent flow, the loss coefficient does not vary much with flow rate. P v ρ = K (0..1) where P is the change in static pressure due to friction, ρ is the fluid density, K is the loss coefficient, and v is the cross-sectional average velocity at the entrance or exit. Control valve capacity (that is, flow when fully open) is designated by a flow coefficient C v. 1

F full = C v P ρ / ρ ref (0..) where the reference density is that of water at 60F (999.0 kg m -3 ). Although it is usually stated simply as a number, C v is actually a dimensional quantity with particular units. gal in C v (=) (0..3) min 0.5 lbf C v is characteristic of a fully open valve. It's the horizontal flow in gpm of 60F water under a 1 psid drop (there are no elevation contributions to the pressure drop used in this definition; it's all friction loss). Manufacturers determine C v experimentally by measuring the flow and pressure drop with the valve fully open, then using (0..). Of course, the C v formula (0..) is related to the loss coefficient formula (0..1). The dimensionless K can be expressed in terms of C v and the area of the valve nozzles (standard pipe sizes from tables). Thus, this K is based on the average velocity in the pipeline, not the interior of the valve. K = A p ρ r C v (0..4) To the extent that K is constant, so will C v be constant with flow rate. 0.3 Inherent characteristics (flow as a function of opening) As a valve closes, it admits less flow for a given pressure drop. Thus flow is a function of pressure drop P and γ, the fractional opening of the valve (0 < γ < 1). We put the γ-dependence into a function φ that decreases monotonically from 1, for the fully open valve, to zero for a closed valve. F = C v φ(γ ) P ρ ρ r (0.3.1) The function φ(γ) is called the inherent characteristic of the valve. Manufacturers determine characteristics experimentally by measuring flow and pressure drop at various valve openings. Ideally, the pressure drop would be kept constant, as if the valve were installed between two tanks and fed between constant liquid levels. However, (0.3.1) can be used with any pair of flow and pressure drop measurements.

F F γ There are 3 ideal types that real valves approximate: Constant dp %F dec inc % open Linear for liquid level control ϕ( γ )= F = γ (0.3.) F full constant P Increasing-sensitivity (equal percentage) for pressure and flow control ( )= F ϕ γ = R (1 γ ) (0.3.3) F full constant P where R is the maximum rangeability; that is, the ratio between the fully open flow rate and some minimum flow. R is often 30 to 50. Notice that this is not the practical rangeability, because the valve should usually operate between about 10 and 80% open. Notice also that (0.3.3) predicts that the minimum flow occurs when the valve is fully closed, so it's not to be believed for small openings. Decreasing-sensitivity (quick-opening) for shut off and fast flow Equal-percentage is most commonly used. 3

Inherent characteristics can be expressed in terms of the loss coefficient through (0..4). This allows the valve to be described with its associated piping in a mechanical energy balance. For a linear valve, K (linear ) = A p γ = K fullyopen γ (0.3.4) ρ r C v where A p is the flow area of the valve nozzles. Similarly, for an equal percentage valve, K = A p R (1 γ ) = K fully open R (1 γ ) (0.3.5) (eq%) ρ r Cv In general, for manufacturer's data that express fractional flow as some function of opening, A p K = ρr C v φ (γ ) = K fully open φ (γ ) (0.3.6) In (0.3.4-6) we are representing K as a function of valve opening γ; i.e., the loss coefficient at any particular valve condition. C v, however, is the published capacity of the valve, a constant in the equations. 0.4 Installed characteristics We have defined the inherent characteristic as the function φ(γ), a property of the valve. To make use of a valve, we install it in piping, and we want to know the dependence of flow on valve opening. This installed characteristic is given by F F = φ( γ ) P P full γ = 1 γ (0.4.1) In general, installed characteristics differ from inherent characteristics. This does not represent some alteration in the valve φ(γ) has not changed. Rather this behavior is the result of the pressure drop across the valve varying as the valve is opened. Consider a control valve in series with a pump and other equipment. 4

FIC Imagine the valve being fully open, accounting for some portion of the total pressure drop in the piping. Now close the control valve to an intermediate opening. Its loss coefficient K is now increased, but the flow resistance of the rest of the piping has not changed. Thus the valve is now responsible for a greater fraction of the total piping pressure drop. This effect is exacerbated when the supply head decreases with increasing flow, as with a centrifugal pump. head pump curve arrows show valve contribution to head loss. partially open fully-open valve fixed piping static head flow Therefore, at the intermediate valve opening, there is a greater pressure drop across the valve than when fully open. Naturally, this drives a greater flow than would be observed had the pressure drop remained unchanged. The result is an approach of the equal-percentage inherent characteristic toward a linear installed characteristic. The installed characteristic is determined by the properties of the valve (the inherent characteristic) and the piping system that surrounds it. Suppose that the manipulated variable is a stream that circulates through equipment in a piping loop, driven by a pump. From the mechanical energy balance on the loop, the pump head TDH is expended on fixed friction loss in the piping and equipment and variable friction loss in the valve. 1 F TDH (F ) = [ K piping + K cv (γ )] g A p (0.4.) TDH(F) is the pump curve; K cv is the inherent characteristic, expressed as a loss coefficient by (0.3.6). Velocity has been expressed as the flow rate 5

F divided by an appropriate pipe area. From (0.4.), combined with the pump curve, the installed characteristic (F/F full vs. γ) can be found. 0.5 Using the valve in a control system: valve gain Installed characteristics become important in designing control systems, because the dependence of F on γ should not show sensitive regions that would make control difficult. Consider this portion of the control loop: SP + E CO MV MV CV - G c G t G v G p The controller output CO is converted by the transducer into a signal MV' that varies between 3 and 15 psig. The valve transfer function G v relates the air pressure in the control actuator to the flow that passes through the valve. Leaving aside questions of transient response, let us look only at the gain. Suppose the simplest case, that the installed characteristics (0.4.1) are linear. Then MV 3 F = F full γ = F full 15 3 (0.5.1) where MV' has units of psi. In deviation variables, this becomes F * = F full MV * (0.5.) 1psi or * F (s) F full Gv (s) = MV * (s) = 1psi f (s) (0.5.3) where f(s) represents dynamic characteristics of the valve. Thus the gain, i.e., the impact the controller can have on manipulated flow, increases with F full, as would be supplied by a larger valve. Suppose that the installed characteristic is some arbitrary nonlinear function ψ(γ). Then the characteristic would be linearized around the reference condition for control design. 6

F * = F full ψ γ MV * = F full ψ MV * γ s MV s 1psi γ s (0.5.3) The control engineer must examine the degree of nonlinearity, represented by the magnitude of the partial derivative. If it shows significant variation (say, a factor of ) over the domain of γ, then the valve gain, and thus the loop gain, will vary with operating condition. Thus a control system designed to be stable at one reference condition γ s might be unstable at another condition. 0.6 Using the valve in a control system: valve dynamics Most often it is sufficient to describe the valve by a first-order transfer function. The gain relates the flow capacity to the 1 psi range of driving pressure. The characteristic time increases with the size of the valve. 0.7 Specifying a valve At the minimum you must specify a size and a type. In general, select the type on process grounds: for example, if the stream is clean, use a globe valve. If it contains solids, you may want to go to a ball valve. If you need lower pressure drop, use a butterfly valve. To select the size, you need first to specify normal, maximum, and minimum flows that your process requires. For example, if you are supplying heating oil to a reboiler, set the normal flow for the design heat duty and the extreme flows to handle the upsets you realistically expect. You will also need to decide how much pressure drop you can reasonably expend on the valve. With the valve fully open, for example, the pressure drop across the valve should be about half that across the rest of the piping in the flow loop. Knowing a flow rate and the pressure drop, you will know the product C v φ(γ) by (0.3.1). You must now make some decision about the valve characteristic. For initial estimates, you might presume a linear characteristic and see if your operation will take place between 10 and 80% of stem travel for the expected min to max flows. If you need much greater rangeability, you may have to use multiple valves, as described by Shinskey (1996). The end result is a valve C v that can handle the maximum required flow at somewhat less than fully open Now select a valve from a catalog that meets the required C v. The next step is to calculate the installed characteristics for the catalog C v and inherent characteristics, combined with your piping system. From this, determine whether the selected valve has reasonably constant gain (slope of the installed characteristic) between min and max flows. 7

Try to satisfy these conditions some may well be in conflict, so that judgement is in order. Slope of installed characteristics should vary less than 50% over the range of use Max expected flow < 80% open (as installed) Min expected flow > 10% open (as installed) Valve loss at max flow should be about half of the balance-ofpiping head loss. Calculate rangeability from the useful range of the installed characteristics (= 80%/10%), not the full range (= 100%/5%). 8