Organic Elemental Analysis Series II CHNS/O Elemental Analyzer. proven performance. reliable results

Similar documents
Organic Elemental Analysis Series II Nitrogen Analyzer. proven performance. reliable results

High Automation of Thermo Scientific FlashSmart CHNS/O Analyzer using the MultiValve Control (MVC) Module

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

ONH836 Series: Oxygen/Nitrogen/Hydrogen by Inert Gas Fusion

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Gas Chromatography. MS Vent Enhancement to the PreVent System to Optimize Operation with the TurboMass, TurboMass Gold, and Clarus 500 GC/MS Systems

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

ON736 Series: Oxygen/Nitrogen by Inert Gas Fusion

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

Model Description

Rapid and Reliable Detection of Dissolved Gases in Water

Your local gas generation partner. Precision series Modular gas generation solution for GC.

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Versatility. Accuracy. Compact. Versa. Automated Headspace Vial Sampler

Major Design Features

Complete Range of Force Tensiometers

Setting a New Standard in Flash Chromatography Performance

VT900A + VAPOR. Technical data. One Solution. Auto-detection to Ensure Patient Safety. Key benefits and features

LUMAZOTE T ECHNICAL BRO CHU RE

APPLICATION NOTE. GC Integrated Permeation Device

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

LINEAR TRANSFORMATION APPLIED TO THE CALIBRATION OF ANALYTES IN VARIOUS MATRICES USING A TOTAL HYDROCARBON (THC) ANALYZER

GCMSD-Headspace Analysis SOP

Using the PreVent System in Time-Saver Mode with the AutoSystem XL Gas Chromatograph and the TurboMass Mass Spectrometer

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Improve Process Reliability

Now it is. easy to switch. CHS TM Steroid Profiling kit and software. Brochure not for distribution in the USA and Canada

Ruskinn Hypoxia and Anoxia Workstations. innovation in incubation

PE 2400 II CHN/S Operating Instructions Revised 05/29/2015 S.V.

HumiSys HF High Flow RH Generator

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

OMCL Network of the Council of Europe QUALITY ASSURANCE DOCUMENT

TROUBLESHOOTING. Dwell Volume Revisited. Gradient transfer does not have to be problematic.

HiQ laboratory gas generators.

Vehicle and Engine Emissions Testing

The benefits of the extended diagnostics feature. Compact, well-proven, and flexible

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

EasyLine Continuous Gas Analyzers. So smart, they re simple

Toxicology Gas Chromatography-Mass Spectrometry (GC-MS)

CHAPTER 16 %UHDWKLQJ*DV0L[LQJ3URFHGXUHV

Retention Time Locking: Concepts and Applications. Application

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Sorbent Pen Heavy & Labile SVOC s Taints, Off-Flavors, Odors

EASYTOUCH. Because automation makes it all so simple. pentairpool.com

29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

Application Note. Rapid performance verification of AZURA systems with refractive index detector. Summary. Introduction

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Application Note AN-107

GAS FILLING MACHINES PROCESS MONITORING PRESSURE BALANCE

ISO INTERNATIONAL STANDARD

Optimizing Gas Supply for Industrial Lasers

ISO INTERNATIONAL STANDARD

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

Series Environmental Chambers

Pneumatic high-pressure controller Model CPC7000

APPLICATION NOTE. Fast Analysis of Coal Mine Gas Using the INFICON 3000 Micro GC ABSTRACT

Multiple Gas#5 GC configuration Jan 2016

Constant Pressure Inlet (CCN) Operator Manual

METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS. 1.2 Scope. This method is applicable for the

METHOD 3A - DETERMINATION OF OXYGEN AND CARBON DIOXIDE CONCENTRATIONS IN EMISSIONS FROM STATIONARY SOURCES (INSTRUMENTAL ANALYZER PROCEDURE)

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Discovery HP-TGA 75/750. Site Preparation Guide

extraction of EG and DEG from the matrix. However, the addition of all diluent at once resulted in poor recoveries.

ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation

INFLUENCE OF MEASURING PROCESS AUTOMATION ON UNCERTAINTY OF MASS STANDARD AND WEIGHTS CALIBRATION.

The. «Modular Alliance» Gas Generators. ALLIANCE, the partnership that keeps the gas flowing. One step ahead!

Operation of the Perkin Elmer TGA-GC/MS

THE PMI AUTOMATED GAS/HELIUM PYCNOMETER PYC-G100A

Micro Motion 3098 Gas Specific Gravity Meter

AKTA pure 25 New Owner s Intro

EasyTouch. Because automation makes it all so simple. Pool and Spa Control Systems. by Pentair Water Pool and Spa

Agilent 7800 ICP-MS. Specifications and Typical Performance. Fast track metals analysis with Solution-Ready ICP-MS

School of Chemistry SOP For Operation Of Glove Boxes

Automatic Isokinetic Sampler. ST5 Evo

The instrument will process the samples one by one till all the samples have been cleaned up.

Experiment GC : Analysis of BTEX by GC-FID

Tensiometer For the measurement of surface and interfacial tension

H 2. Sensor Series Take no risk! Install a Hydrogen Sensor in your Gaschromatograph

Superior Result from Analytical Instruments The constant purity of the nitrogen improves system stability and ensures reproducible results

Quantos Automated Dosing Solution Preparation Precise concentrations Process compliance Minimize out-of-specs

Calibration Requirements for Direct Reading Confined Space Gas Detectors

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

V10K GAS FEED SYSTEM WALLACE & TIERNAN PRODUCTS

FROG-4000 TM Chemical Analysis System

INTRODUCTION. The Quantum Technology system has the following advantages:, as it does not need plastic gas-bags which are volume-consuming,

no peaks missing peaks too small peaks increasing retention decreasing retention

6890 GC Site Preparation

Elimination of Percent Level H 2 S Calibration Gas from Flare Gas Monitoring Systems Measuring Total Sulfur, H 2 S and BTU.

Series 7250 Ruska High-Speed Digital Pressure Controller. GE Sensing. Features

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

Transcription:

Organic Elemental Analysis 2400 Series II CHNS/O Elemental Analyzer proven performance reliable results

2400 Series II CHNS/O Elemental Analyzer raising the standard Q U I C K G L A N C E One analyzer with three modes of operation: CHN, CHNS and Oxygen Advanced combustion design for handling virtually any type of sample Frontal Chromatography for simple, reliable and accurate measurements NEW EA 2400 Data Manager software for easy data handling The PerkinElmer 2400 Series II CHNS/O Elemental Analyzer (2400 Series II) is a powerful instrument for the rapid determination of the carbon, hydrogen, nitrogen, sulfur or oxygen content in organic and other types of materials. It has the capability of handling a wide variety of sample types in the field of pharmaceuticals, polymers, chemicals, environmental and energy, including solids, liquids, volatile and viscous samples. Based on the classical Pregl-Dumas method, samples are combusted in a pure oxygen environment, with the resultant combustion gases measured in an automated fashion. The design has been field-proven in thousands of laboratories around the world. High-speed microprocessor control, solid-state components and built-in diagnostics provide confidence in performance and reliability. 2

The new EA 2400 Data Manager simplifies data handling and allows convenient storage and reporting capabilities. In addition, PerkinElmer offers the best quality reagents to provide the highest measurement of accuracy and precision. Unlike other elemental analyzer designs, the 2400 Series II has easy access to all components for routine care and maintenance. Multiple modes of operation The 2400 Series II offers multiple analysis options: CHN, CHNS or Oxygen mode. As a user, you may choose one or more options to meet your laboratories needs. Changeover to different modes of operation only requires a few simple steps. The optional Column Switching Accessory (CSA) makes switching to the Oxygen mode very convenient. The CHN mode is the most widely used of the analysis modes. A range of reagents and the ability to optimize the combustion parameters offer flexibility for analyzing virtually any sample types. Interfering elements such as halogens and sulfur are removed before detection. The CHNS mode is specifically designed to simultaneously determine carbon, hydrogen, nitrogen and sulfur in organic materials. The Oxygen mode is optimized for the automatic determination of oxygen in organic materials by pyrolyzing the sample. Upgradeability The 2400 Series II can be upgraded at any time to add additional mode capability to suit the needs of your laboratory. Automated weight entry Accurate weighing of samples is a prerequisite for organic elemental analysis since results are presented on a weight percent basis. To avoid transcription errors, the 2400 Series II provides automatic weight entry from the cost-effective PerkinElmer AD-6 Autobalance as well as other ultra microbalances. Using proven PerkinElmer balance technology, the AD-6 ultra mircobalance provides exceptional resolution and accuracy for the best results. www.perkinelmer.com 3

Principle of operations Separation Detection Combustion Mixing Reduction Figure 1. 2400 Series II CHNS/O Schematic CHN and CHNS A schematic diagram of the PerkinElmer 2400 Series II CHNS/O Elemental Analyzer is shown in Figure 1. The CHN and CHNS modes are based on the classical Pregl-Dumas method where samples are combusted in a pure oxygen environment, with the resultant combustion gases measured in an automated fashion. The 2400 Series II system is comprised of four major zones: Combustion Zone Gas Control Zone Separation Zone Detection Zone In the Combustion Zone, samples encapsulated in tin or aluminum vials are inserted automatically from the integral 60-position autosampler or manually using a single-sample auto injector. 4

In the presence of excess oxygen and combustion reagents, samples are combusted completely and reduced to the elemental gases CO 2, H 2 O, N 2 and SO 2. Users have the flexibility of optimizing static and dynamic combustion conditions to meet the specific sampling need of their laboratory. The combustion products are then passed to the Gas Control Zone of the 2400 Series II. The PerkinElmer 2400 CHN Elemental Analyzer Steady State Readout H 2 0 C0 2 Gases are captured in the mixing chamber of the Gas Control Zone. Here, gases are rapidly mixed and precisely maintained at controlled conditions of pressure, temperature and volume. The result is the thorough homogenization of product gases. After homogenization of product gases, the mixing chamber is depressurized through a column in the Separation Zone of the instrument. The separation approach used is a technique known as Frontal Chromatography. As the gases elute, as illustrated in Figure 2, they are measured by a thermal conductivity detector in the Detection Zone of the analyzer. Since measurements in this design are made as stepwise changes from the carrier gas baseline, the variations associated with the quantification of peak signals in other CHNS/O analyzers is eliminated. Baseline N 2 Figure 2. Chromatogram Oxygen The oxygen determination method used with the 2400 Series II analyzer is based on the classical Unterzuacher method which incorporates the modifications of Oita, Conway and Culmo. The sample is pyrolyzed in a helium/hydrogen (95%:5%) atmosphere at 1,000 C. The resulting products of reaction containing oxygen are converted to carbon monoxide over the platinized carbon reagent. The carbon monoxide and other gases pass through a scrubber where interferences are removed. The carbon monoxide is then controlled, separated and determined in the same fashion as above. www.perkinelmer.com 5

special features Operating gases In the CHN and CHNS modes, operating gases include oxygen, for combustion of sample materials, and a carrier gas either helium or argon. The use of argon as an optional carrier gas is unique to this design and assures cost-effective use of the Elemental Analyzer in those areas of the world where helium is difficult to obtain due to price or availability. In the Oxygen mode the operating gas is helium when using silver vials or helium/hydrogen mixture when using tin vials. Optimized combustion flexibility for best performance Combustion is the most critical step to the success of the measurements and ultimately affects the accuracy and precision of the final result: the weight percent of the element or elements being measured. The 2400 Series II provides advanced combustion conditions of temperature, time and available oxygen (or pyrolysis gas in the case of Oxygen mode). The user has the flexibility to increase the sample s combustion time in the oxygen atmosphere as well as the amount of oxygen that is introduced allowing for complete combustion of virtually any type of sample. Gas control zone The thorough mechanical homogenization of product gases under the controlled conditions of pressure, temperature and volume are important in order to achieve the most precise results. Laboratory efficiency The 2400 Series II offers fast analysis times, optimizing efficiency and precision. A typical CHN analysis is accomplished in under six minutes, CHNS in eight minutes and oxygen in four minutes. A unique wake-up routine allows the automatic equilibration and standardization of the 2400 Series II at an operator-selected date and time. This feature allows the system to be ready when you are. A 60-position autosampler allows unattended operation night or day. The autosampler design has been tested through millions of cycles, both in accelerated quality assurance testing, and most importantly, in labs like yours throughout the world. Diagnostic routines monitor electronic and pneumatic components for proper operation and alert the operator in the rare event that a failure is encountered. A programmable gas saver valve allows for the automatic reduction of carrier gas flow rate when the analyzer is not in use. Consumables Only the best reagents, tubes and sample vials assure optimum analyzer performance. Every genuine PerkinElmer consumable and reagent is of high quality and designed specifically for your PerkinElmer instrument. Convenient kits for 2,000, 4,000 or 10,000 experiments simplify ordering and eliminate waste. Frontal Chromatography for highest reliability In the 2400 Series II, there is selective retention of the gases to produce a steady-state, stepwise signal rather than a peak signal (see Figure 2). This technique allows for a simpler, more reliable and accurate determination of the combustion gases than other CHNS/O systems which use a peak separation method. Figure 3. CHNS kit (500) www.perkinelmer.com 6

specifications 2400 Series II CHNS/O Elemental Analyzer Analysis mode options: Option 1, CHN mode Option 2, CHNS mode Option 3, Oxygen mode Upgradeability Analysis times Sample size The CHN mode is the most universal of the analysis modes because of the combination of the reagent design and the Optimize Combustion control parameters. Interfering elements (halogens and sulfur) are removed. The CHNS mode is designed to handle conventional organics. This mode is specifically designed to include sulfur, which reduces universality. This includes limiting the range of sample types and sample size (1 to 2 mgs recommended). Metal cations are excluded. Special care must be used in calibration and blanks for lower levels of sulfur. The Oxygen mode is designed to handle conventional organics. This mode excludes compounds containing phosphorous, fluorine, silicon and metal cations. Samples containing mineral matter must be demineralized prior to analysis. The user may choose any or all modes. The 2400 Series II may be freely upgraded at any time to add additional mode capability to suit the needs of the laboratory. CHN: 6 min, CHNS: 8 min, Oxygen: 4 min 0 to 500 mgs, depending on sample type. Small samples will generally be limited by weighing errors, but may be used. Large samples are limited by the sample matrix and content (see Analytical Range). Analytical Element Range (mgs) detector range C 0.001-3.6 S 0.001-2.0 H 0.001-1.0 O 0.001-2.0 N 0.001-6.0 Analytical Mode Helium Carrier Gas Argon Carrier Gas performance* Accuracy[%] / Precision [%] Accuracy[%] / Precision [%] Based upon organic CHN < 0.3 / < 0.2 < 0.4 / < 0.3 standards CHNS < 0.3 / < 0.2 < 0.5 / < 0.4 Oxygen < 0.3 / < 0.2 < 0.4 / < 0.3 0.1% = 100 ppm Best performance requires an ultra microbalance *with 95% confidence limits for an organic standard material weighed with a PerkinElmer AD-6 Series ultra microbalance. 7

EA 2400 Data Manager... This powerful data management software is intuitive and user-friendly, providing a wide range of standard features and capabilities giving you more flexibility. Combined with the proven 2400 CHNS/O Series II Elemental Analyzer, PerkinElmer customer service and support, and the highest quality reagents and supplies, you can be sure you are receiving a complete, robust system for accurate, reliable material characterization. Software capabilities The 2400 Series II data manager is a SQL-based software. It allows the use of a standard PC to collect and store data, perform advanced calculations, recalculate a result, run queries (searches), generate statistics, create reports and archive data. For regulated environments, it is compliant with 21 CFR Part 11. The software lets you: Browse a list of run results that have been collected from the instrument. Browse a list of instrument diagnostic messages such as leak test results or instrument status information. Browse a list of user-defined queries that enable you to search for a specific set of run results. In addition you can also: Filter the browsing to show specific run results. Search for run results by date and time, user ID, Project ID, mode, run type and sample ID. Customize the columns you wish to display in the results table. Select multiple runs to perform advanced calculations, recalculations or statistical analyses. Figure 5. Advanced Calculations screen Advanced calculations Advanced Calculations are standard features in the software allowing users to: Perform Elemental Ratio calculations of H/C, N/C, S/C or C/N. Determine the simplest Empirical Formula of a sample to help to confirm an unknown. Determine % Polymer in a co-polymer formulation or blend using a hetero-element. Analyze Mixtures when a reasonable element differential exists between two compounds. Figure 4. Run Results screen www.perkinelmer.com 8

EA 2400 Data Manager Study newly synthesized organic compounds for the amount of Solvent of Crystallization. Correct the result % on all elements to a dry basis when the moisture content is known. Determine the Heating Value in kj/g of a material when the CHNS and O percentages are known. This is defined as the theoretical amount of energy released as the material combusts in the oxygen atmosphere. Diagnostics The diagnostic information provided from the instrument is stored providing a permanent record of instrument history and status. Enhanced security for regulated environments In response to 21 CFR Part 11 and the increasing data security requirements in some industries, PerkinElmer s Enhanced Security (ES) feature offers the technical compliance tools needed to meet these mandatory regulations. Queries The Query (search) Setup capability allows you to select criteria to be used to generate a very specific search of the run results in the database. Query definitions can be saved and made available to all users or only the user that created the query. Figure 6. Statistical Analyses screen Statistical analyses Statistics provide a method or basis to better understand your data. The EA 2400 Data Manager offers a choice of Average, Standard Deviation, Variance and Relative Standard Deviation analysis. Reporting and exporting If you wish you can print the table of selected runs or an entire results table, or you can use one of the available predefined report templates. You may chose to either print the hard copy and/or save the report using pdf-, doc- or rtf- file format. Figure 7. Search screen Data can be exported to a csv- or xls- file format. www.perkinelmer.com 9

special features 2400 Series II CHNS/O Elemental Analyzer Optimized combustion Gas control zone Diagnostics Wake-up Shutdown Gas saver Run counters Advanced calculations Automatic weight transfer Helium or argon carrier gas Copper reagent reduction Column switching accessory Offers advanced combustion conditions for static and dynamic step. Users optimize temperature, time and available oxygen. Controls pressure, temperature and volume of the product gases. Monitors electronic and pneumatic components continuously, assuring best instrument performance. Allows automatic instrument startup, equilibration and calibration at any operator-selected time and date. Allows for the automatic reduction of operating temperatures at operator-selected time and date. Provides automatic reduction of carrier gas flow rate with a built-in valve at an operator-selected time and date. Aids in routine maintenance procedures and monitors reagent and expendable components. Allows calculations on filters and for polymers, element ratios, mixtures, simplest empirical formula, heating valve, calculates solvent of crystallization or results on dry basis. Eliminates transcription errors and simplifies operations through automatic weight transfer using a PerkinElmer cost-effective AD-6 ultra microbalance, Mettler UMX2 or Sartorius SE2. Accepts argon as a substitution for the system carrier gas in areas where helium is difficult to obtain or is high in price. Allows for the reduction (with 5-8% H2 gas mixture) of the copper reagent for reuse at operator-selected time and date. The Column Switching Accessory (CSA) is available to conveniently switch columns from CHN or CHNS mode to the Oxygen mode. Physical details Power requirements Bench space 100 VAC ±10% Width 61 cm (24 in) 120 VAC ±10% Depth 55 cm (22 in) 230 VAC ±10% Height 55 cm (22 in) Weight ±45 kg (100 lbs) PerkinElmer Life and Analytical Sciences 710 Bridgeport Avenue Shelton, CT 06484-4794 USA Phone: (800) 762-4000 or (+1) 203-925-4602 www.perkinelmer.com For a complete listing of our global offices, visit www.perkinelmer.com/lasoffices 2005 PerkinElmer, Inc. All rights reserved. The PerkinElmer logo and design are registered trademarks of PerkinElmer, Inc. Enhanced Security is a trademark and PerkinElmer is a registered trademark of PerkinElmer, Inc. or its subsidiaries, in the United States and other countries. All other trademarks not owned by PerkinElmer, Inc. or its subsidiaries that are depicted herein are the property of their respective owners. PerkinElmer reserves the right to change this document at any time without notice and disclaims liability for editorial, pictorial or typographical errors. 007390_01 Printed in USA