Installation and service should be performed by a qualified service professional.

Similar documents
BY HYDROHOIST BOATLIFTS

BY HYDROHOIST BOATLIFTS

OPERATION. Thank You. General Operation. Lowering the Lift. Raising the Lift. Safety Tips

RAM 4021-DPX Operation Manual

RAM 4021 Operation Manual

Model PSI Compressor with 3-Gallon Air Tank 12VDC

R E D I C O N T R O L S

This document to be used with Hurley traditional Davits

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

2,500/4,000 LB Easy Riser Vertical Cable Feighner Lift

AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide

Instruction Sheet. CP2000: 2000 lb Cable Puller IMPORTANT RECEIVING INSTRUCTIONS SAFETY ISSUES

Underwater Housing for Canon EOS M

Concentrate Distribution System (Stand Mounted) A-CDS-70-X & A-CDS-TANK-X-ST Industrial Drive, Orlinda, TN 37141

OPERATION and MAINTENANCE Guide

SP-110 Autopilot OPERATION

User Manual GRI- 1500Li

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

444C DUAL PERFORMANCE VALUE PACK

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

SANP ACTING RELAYS YT-520/525/530 SERIES

VL 2K LIFT D-L WINCH INSTRUCTIONS (Applies to P/Ns , , , , , )

STYRIGGER PRODUCT MANUAL

Gemini Owner s Manual

SPECIFICATIONS APCEPH1

400C & 450C DUAL PERFORMANCE VALUE PACKS

LOCK UP VALVES YT-400/405/430/435 SERIES

OWNER'S MANUAL FISHING AND PONTOON BOAT ANCHOR WINCH. 24' Class Rope Anchor Winch

Shoreline Cantilever Lift 2500lb Capacity Models: (108" inside width) - Part # (120" inside width) - Part #

DURAS INFLATABLE BOAT OWNER'S MANUAL

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

Manual Leveling Control Installation/Operation

Welcome to the World of In-Home Gardening! Simple Steps to Get Your AeroGarden Up and Growing (No Tools Required)

Endo-Flush Order # ZUTR30004 OPERATION MANUAL. Zutron Medical, LLC W 98 th St #40-27 Lenexa, KS Phone Fax

Apex Evaporator Manual

In Vivo Scientific, LLC INSTRUCTION MANUAL

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

1020 Industrial Drive, Orlinda, TN fax

PC1131 Electric Air Compressor

KJ4000 Operating Instructions & Parts Manual NSN

Operator s Manual. with Maintenance Schedule. Fourth Edition Second Printing Part No

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

product manual HM-4140, HM-4150, HM-4160 HM-4160A HM-4150 Humboldt FlexPanels

Cocoa Patio Pond with Lit Spillway

Pressure Relief Valve Instruction Manual

C - SERIES. Height Adjustable Portable Goal Supports. Installation & Owner s Instructions C1000 C2000. Made in the USA

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Progression 24LD Stern Drive

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM

For ELECTRIC ANCHOR WINCH Models: T Pontoon 35 T sw Salt Water Series Coastal 35

03 Vessel Fitness and Safety

MODEL NUMBER: P PORTABLE COMPRESSOR

For ANCHOR WINCH Model: T Big Water 45 T sw Salt Water Series Big Water 45

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Portable Oil Lube Air Compressors

QUALITY ALUMINUM BOAT LIFTS, INC. INSTRUCTIONS. Dominator Lake Lift

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

icreasepro Creaser Operators Manual

Welcome to the World of In-Home Gardening! Simple Steps to Get Your AeroGarden Up and Growing (No Tools Required)

OPERATION INSTRUCTIONS Form 6899-TE, Four-Post Lift Rack. MODELS L451 and L454 (all model variations) Copyright 2014 Hunter Engineering Company

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

CONTENTS AIRBERTH OWNER S MANUAL I 3

! WARNING! IMPORTANT HPA AIR TANK SAFETY INSTRUCTION AND GUIDELINES ! WARNING! IMPORTANT SAFETY INSTRUCTION AND GUIDELINES

100C Air Compressor Kit

200 PSI COMPRESSORS - MODEL NUMBERS

2 GAL AIR COMPRESSOR OPERATOR S MANUAL 1/3HP/2-GALLON IMPORTANT: READ THIS OPERATOR S MANUAL BEFORE USING

HAS2400 Hepa Air Scrubber

Manual. FRESH AERO OneOP Model PC (Portable Compressors) Tire Inflator. Where Imagination Meets Innovation

DuPont Personal Protection Instruction Manual for Universal Pressure Test Kit No

Air Tractor Preventative Maintenance Manual And Troubleshooting

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

03/07/2014 V

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13

IMPORTANT SAFETY INSTRUCTIONS

S/Y MORSKI ZEKAN TECHNICAL INFORMATION

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

200 PSI FAST-FILL AIR SOURCE KIT

with O 2 Controller Instruction Manual

VERTICAL AIR COMPRESSORS

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Lock Up Valves YT-400, YT-405 USER'S MANUAL

Yoke Block Instruction Manual

MODEL NUMBER: P PORTABLE COMPRESSOR

Lockout / Tag out Program

Operating Manual. Model 25200B/25202B Refrigerant Recovery Unit. (Not for use in automotive R-134a applications)

CROSSBOWS SAFETY INFORMATION. FIRestorm ASSEMBLY INSTRUCTIONS and OWNERS MANUAL. Outdoors. Outdoors. Please keep for future reference

BS2000 MOTOR ELECTRONICS, INC. PROTECTION INSTRUCTION MANUAL. (407) Phone: Website:

XpressFill XF4500 Counter Pressure Filler. Operating Instructions

Instruction Manual: VelectriX Ascent 29 MTB

UE- 90- X X X X X X O P E R AT I N G M A N UA L 0 TO 90 HYDRAULIC UPENDER

Installation of Your SprayMaster System

5.0 INSPECTING, FILLING AND LABELING SMALL CYLINDERS

Transcription:

Damage to your lift or vessel can result from improper initial setup of the system. Consult a HydroHoist Certified Installer for initial setup and support Installation and service should be performed by a qualified service professional. To avoid the risk of electric shock make sure the control is disconnected from any power supply during installation. The GFCI supplied with your control is designed for outdoor applications but is NOT to be submerged or directly sprayed with water. Keep the GFCI from being directly sprayed by the exhaust port of the control. Verify that your power receptacle is clean and is supplying between 110VAC 120VAC with at least 15 amps of service. Keep children away. Do not allow yourself to be distracted or walk away from the lift during operation. Do not overload the lift. Make sure your boat bilge pump is set for automatic. Significant water accumulation in the bilge may overload the lift. Make sure any ballast tanks are empty before lifting the boat. Lift is not designed for lifting people. No persons should be under the boat while it is in the suspended position. Weight must be distributed equally side to side and bow to stern before lifting, otherwise the boat will not center properly and appear to be misaligned on the lift. Symbols: Informational purposes WARNING

Control Configurations The HarborHoist is a versatile boat lift system. The control and functionality of this type of lift will vary with capacity. See the table below for the type of control for your lift. 4 Valve Control Lift Capacity Control Configuration 4400, 6600, 8800 4 Valve 8800 Short, 12000, 15000, 18000, 20000 5 Valve 25000 6 valve Control Configurations and Functionality Button Control: A: LEVEL - Levels lift B: UP - Raises lift C: STOP - Stops all operation of lift D: DOWN - Lowers lift LEDs: A: *Front Port (FP) - valve LED B: Port (P) C: Level (L) D: *Rear Port (RP) - valve LED E: *Front Starboard (FS) - valve LED F: Starboard (S) G: *Rear Starboard (RS) - valve LED H: Power (PWR) * Is illuminated when valve is open

5 & 6 Valve Control Button Control: A: AUX - Puts air in auxiliary tanks only B: UP - Raises lift C: STOP - Stops all operation of lift D: Down - Lowers lift LEDs: A: *Front Port (FP) - valve LED B: Port (P) C: Auxiliary (AUX) D: *Rear Port (RP) - valve LED E: *Front Starboard (FS) - valve LED F: Starboard (S) G: *Rear Starboard (RS) - valve LED H: Power (PWR) I: *Auxiliary Tank (AUXT) - valve LED * Is illuminated when valve is open

Four Valve Control General Operation Familiarize yourself with the Control Box. We have created a simple to use 4 BUTTON user interface consisting of UP, STOP, DOWN, and LEVEL buttons. These are the basic functions for operating the HarborHoist lift. The state-of-the art valve controls and circuitry will insure that your lift comes up level each and every time you lift your boat from the water. Lowering the lift: Make sure the Power LED is illuminated and flashing Press the DOWN button, this will open the valves Allow the lift to submerge (walkways will remain above water) Untie lift safety lines from boat Board the boat only after it clears the lift Raising the lift: Make sure the Power LED is illuminated and flashing Float boat into established balanced lifting position on the lift Tie off safety lines to the boat Everyone must exit the boat before lifting Press UP button Once the lift is fully raised, air bubbles will be visible exiting from ALL main tanks Press STOP on control Re level the lift: If for some reason the lift should become out of level while in the up position perform the following: Press the LEVEL button. This will open up the valves necessary and lower the high points of the lift to make it level. The control will shut off once the lift is level. You can then proceed with either lifting or lowering the lift as desired Note: you may want to check for leaks in the air system, this could be the cause of the lift becoming unlevel over time.

Four Valve Control General Operation Express Lowering: This feature lowers the lift as fast as possible only when a boat is NOT present on the lift or in the rare stance it goes into safety shut down mode. Press DOWN + LEVEL at the same time and hold for 5 seconds How the leveling sensor controls the lift During the lifting or lowering mode the controller will try to keep the lift within ±2 degrees of level, when in this state all valves are open, feeding air to all tanks to give maximum performance. If the sensor determines it is out by more than ±2 degrees the appropriate logic is applied to valve configuration to bring it back into level. Safety shut down mode In the rare instance that the lift is unable to correct the lifting and it becomes out of level by more than ±10 degrees the lift will go into Safety Shut Down Mode. The PORT and STARBOARD LEDs on the controller will flash back and forth. The control is in a locked-out state. To UNLOCK 4 Valve CONTROLLER from shut down mode Push the STOP button to clear the safety shut down mode. Then press and hold for 5 seconds the DOWN + LEVEL button and all valve LEDs will turn on indicating all air valves are open allowing the lift to submerge. When the lift is completely submerged you can then re-lift the vessel by pressing the UP button. The cause of the lift not being able to maintain a level lift could be the location of vessel. The vessel may need to be relocated on the lift or equipment onboard relocated. See trouble shooting for more details.

Five and Six Valve Control General Operation Familiarize yourself with the Control Box. We have created a simple to use 4 BUTTON user interface consisting of UP, STOP, DOWN, and AUX buttons. These are the basic functions for operating the HarborHoist lift. The state-of-the-art valve controls and circuitry will insure that your lift comes up level each and every time you lift your boat from the water. Lowering the lift: Make sure the Power LED is illuminated and flashing Press the DOWN button, this will open the valves Allow the lift to submerge (walkways will remain above water) Untie lift safety lines from boat Board the boat after the boat clears the lift Raising the lift: Make sure the Power LED is illuminated and flashing Float boat into established balanced lifting position on the lift Tie off safety lines to the boat Everyone must exit the boat before lifting Press UP button Once the lift is fully raised, air bubbles will be visible exiting from ALL main tanks Press STOP on control AUX lift: The Aux feature will allow you to utilize the full lifting capacity of a lift system with auxiliary tanks. By pushing the AUX button it will close the main tank air valves and direct all air to the auxiliary tanks allowing them to be emptied completely of water, giving you the maximum lifting capacity of the system. The AUX button should only be utilized when the lift has reached full lifting capacity on the main tanks. Verify all the main tanks have bubbled out Press the AUX button on the controller When the auxiliary tanks have bubbled out press the STOP button

Five and Six Valve Control General Operation Express Lowering: This feature lowers the lift as fast as possible only when a boat is NOT present on the lift or in the rare instance it goes into safety shut down mode. Press DOWN + AUX at the same time and hold for 5 seconds How the leveling sensor controls the lift During the lifting or lowering mode the controller will try to keep the lift within ±2 degrees of level, when in this state all valves are open feeding air to all tanks to give maximum performance. If the sensor determines it is out by more than ±2 degrees the appropriate logic is applied to the valve configuration to bring it back into level. Systems with auxiliary tanks will only fill when the lift is within ±2 degrees of level. Safety shut down mode In the rare instance that the lift is unable to correct the lifting and it becomes out of level by more than ±10 degrees the lift will go into safety shut down mode. The PORT and STARBOARD LEDs on the controller will flash back and forth. The control is in a locked-out state. To UNLOCK 5 & 6 Valve CONTROLLER : Push the STOP button to clear the safety shut down mode. Then press and hold for 5 seconds the DOWN + AUX button and all valve LEDs will turn on indicating all air valves are open allowing the lift to submerge. When the lift is completely submerged you can then re-lift the vessel by pressing the UP button. The cause of the lift not being able to maintain a level lift could be the location of vessel. The vessel may need to be relocated on the lift or equipment onboard relocated. See troubleshooting section for more details.

Tie Off Mooring Information (Mooring ropes not included) Tie the lift off using a tie off method similar to mooring a boat in a slip. The goal is to restrain the lift as much as possible but still leaving enough slack in the lines that the lift can still raise and lower properly. Use a good mooring rope that has enough strength for the size of boat and lift you are installing. Minimum Rope Dia. of 3/8 for boats up to 25, 1/2 for boats up to 35, and 5/8 for boats up to 45. There are several variables involved in rope selection and tie of locations so be sure that you check the mooring regularly for any changes in rope condition, tie off points, etc. Be sure that all tie off points are in good condition and are structurally sound enough to handle the load the mooring will apply. Recommended: Double Braid Nylon Dock lines.

Vessel Loading Proper loading of your vessel onto the lift is extremely important Failure to load properly could cause improper lifting of your vessel. Verify that the that the equipment weight is distributed evenly on the vessel to keep the Center of Buoyancy (CB) with in manufacture s limits. When loading, the CB of the vessel should with in 1 foot forward or aft of the CB of the lift. This should make for a level lift. Contact the vessel manufacture for CB of your vessel To promote water drainage to the rear of the vessel it is recommended that the vessel CB be aft of the lift CB Some service vessels which are heavy and short in length and utilize a lift with auxiliary tanks may need to adjust auxiliary tank locations. Contact customer support or an authorized dealer if you feel you may have a vessel of this type. Many of today s vessels have built in ballast tanks to create additional wake or fishing boats for bait and fish. These should be completely emptied before lifting the vessel. If not damage could occur to the boat, lift or dock. CB of 4400

CB of 6600 CB of 8800 CB of 8800 Short

CB of 12000 CB of 15000 CB of 18000

CB of 20000 CB of 25000

Safety Tips Test GFCI on a monthly basis To test: Plug in cord to power source Observe light is on TEST RESET INDICATOR LIGHT Push test observe light is off Press reset and verify light is on Preventative Maintenance Because of the harsh environments in which the HarborHoist G1.5 can be installed, it is very important to inspect your HarborHoist occasionally to ensure it is at peak performance. (Operating Properly) On a monthly basis inspect and ensure the following: GFCI trips and resets properly when the TEST and RESET buttons are pressed (see GFCI Test Procedure) All air hoses are firmly attached, clamps are tight, and there are no apparent leaks All the aluminum components are structurally sound and no heavy corrosion is visible The hull pads (if equipped) are structurally sound with no severe cracking or damage All mounting / attachment brackets are secure If rope mooring is used, inspect the ropes for any issues that may compromise the integrity Most importantly, run your blower fan at least once a month even during the off season. Press UP button on the control and let it run about 1 minute to help keep the motor contacts and brushes clean If your lift is equipped with an external level sensor, verify it is secured to the lift and no damage to the sensor or cable is present

Control will not power on Troubleshooting Verify GFCI has not tripped Verify GFCI on dock receptible has not tripped. Verify dock power is on Verify cable or power connection is not damaged (unplug before inspection) Over time the lift lowers on its own Leaky air hose, tank or fitting While operating DO NOT unplug the control, doing so will allow the valves to remain open. When operating press STOP then wait 5 seconds before unplugging control. This will allow all valves time to close properly before power is removed Lift is not lifting the vessel level Re-position the vessel on the lift Verify weight is distributed evenly in the vessel Verify ballast tanks, bait or live wells do not have water remaining in them Verify the lift raises level when vessel is not on the lift If lift is not level, verify sensor is connected to the frame properly and no damage has occurred to it or its cable The level sensor may need to be calibrated back to zero level (See Calibrating the level sensor to zero level on instructions) PORT and STARBOARD LEDs will flash together rapidly on the control The level sensor has lost communication with the control. Contact your local dealer or HarborHoist customer service support for assistance

Calibrating the level sensor to zero level Do this step when the vessel is NOT on the lift A. Press the UP button, this will raise the lift to its highest point B. Each main tank must be bubbling from the relief hole in its bottom before pressing STOP The lift MUST be in a fully up position before performing this operation Push and hold the UP and DOWN buttons at the same time until the PORT and STAR- BOARD LED s flash together 5 times C. Your level sensor is now recalibrated and your lift is now set and ready to use. If your level sensor ever loses communication with the controller the middle PORT and STARBOARD LEDs will flash continuously together rapidly. Contact your local dealer or HarborHoist customer service support for assistance

Boat Fitment Take care to clear shafts, thru hull fittings, chines, etc. Keel of boat must NOT rest on cross beam and should clear the beam by at least 1 inch. Center of gravity (CG) of the boat, must be in the the center of the lift (unless Auxiliary tanks are used) bow to stern and port to starboard. This will evenly distribute the load over the lift allowing for maximum lift height and maintain the appearance of the lift floating level. For boats with Auxiliary Tanks - the goal is to have the same lifting forces behind the CG of the boat as in front, in order to achieve good balance. The simple method for this is to have the same amount of tank forward of the CG of the boat as behind the CG. For Auxiliary tank lifts adjust the 8 long center tanks to help accomplish this. Additional adjustment can be made by shifting the boat fore and aft. The main tanks have a total tank length of 43 4 of tank for an 8 main tank unit. A 12K lift has an additional 8 of tank available, the 15K and 18K have 16 additional each (18K are wider, deeper tanks). The CG of the boat, when located with the transom at the end of the lift, should never be forward of the Center of the lift. This condition suggests another set of Main tanks may be needed due to length (if it is over by less than 18 the boat can be shifted back). If the Auxiliary tank(s) is completely behind the CG of the boat, moving the tank further back amplifies the lifting effect of the rear (much like moving the smaller child further away from the pivot on a teeter totter.) If you need to move the Auxiliary tank back further than the end of the lift, be sure you have enough space available between the outdrives and the tanks to avoid damage to one or the other. It is the responsibility of the End User to insure that: The lift is installed by a certified HydroHoist Installer The lift is operated in a safe manner Regular inspection is made of the lift components All safety and warning labels are understood No alterations or modifications may be made to the HydroHoist equipment without the express written consent of HydroHoist Marine Group. Re-installation, adjusting the bunks, and or adjusting the tank beam spacing of the equipment must be performed to the standards set forth by HydroHoist Marine Group. It is the obligation of the end user to inform all equipment operators of the above conditions. Owners Manuals and Safety Warning Decals are available on request from HydroHoist Marine Group.

Warranty and Registration What Is Not Covered By This Warranty. HydroHoist does not warrant any product, component or part (a) That is not manufactured by HydroHoist (b) That is not installed or serviced by employees or contractors of HydroHoist or an Authorized HydroHoist Dealer (c) Damage caused by failure to provide a suitable installation environment for the lift (d) Damage caused by the use of the lift for purposes other than those for which it was designed (e) Damage caused by disaster such as fire, flood, wind and lightning (f) Damage caused by unauthorized attachments or modification (g) Damage caused by operation, maintenance or repair of the product contrary to written instructions from HydroHoist (h) Damage during shipment (i) Damage caused by any other abuse or misuse by the Consumer (j) Which has an altered or defaced service number Parts and Customer Service Contact Customer service, parts and shipping: Customerservice@boatlift.com Product Registration Verify that your authorized HydroHoist dealer did register your HarborHoist product. If the lift is not registered warranty support may be limited. Go to www.boatlift.com to register your lift