Gaseous oxygen technical grade Specification

Similar documents
Svensk läkemedelsstandard

Svensk läkemedelsstandard

Svensk läkemedelsstandard

Date of Shipment: Xxxxx 00, 20xx 3402c National Institute of Advanced Industrial Science and Technology National Metrology Institute of

tbs TDC8(5630)P 3 Draft Tanzania Standard Textiles Ropes Specifications: Part 2. Ropes made from Man-made fibres (First edition)

Svensk läkemedelsstandard

ISO INTERNATIONAL STANDARD. Welding consumables Gases and gas mixtures for fusion welding and allied processes

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

CORESTA RECOMMENDED METHOD Nº 67

ExamLearn.ie. The Air & Oxygen

VOLUMETRIC TECHNIQUES

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

Experiment #2. Density and Measurements

Standard Test Procedures Manual

OPERATING INSTRUCTIONS

ISO INTERNATIONAL STANDARD. Flow-metering devices for connection to terminal units of medical gas pipeline systems

ISO INTERNATIONAL STANDARD

PERFORMANCE SPECIFICATION PROPELLANT, HYDROGEN

CHAPTER 16 %UHDWKLQJ*DV0L[LQJ3URFHGXUHV

DURING the course of certain investigations it became

A-A June 2000 SUPERSEDING BB-N-411C 3 January 1973 COMMERCIAL ITEM DESCRIPTION NITROGEN, TECHNICAL

ISO INTERNATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD

METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS. 1.2 Scope. This method is applicable for the

Lab Equipment ANALYTICAL BALANCE

HiQ laboratory gas generators.

BRITISH STANDARD BS 341-4: Transportable gas container valves. Part 4: Pressure relief devices ICS

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Gases and welding distributors continue

State of Nevada Department of Transportation Materials Division METHOD OF TEST FOR SAND EQUIVALENT

DEMONSTRATION 2.1 PROPERTIES OF CO 2. Chapter 2: Gases

States of Matter. Q 7. Calculate the average of kinetic energy, in joules of the molecules in 8.0 g of methane at 27 o C. (IIT JEE Marks)

This document is a preview generated by EVS

METHOD 204F--VOLATILE ORGANIC COMPOUNDS CONTENT IN LIQUID INPUT STREAM (DISTILLATION APPROACH) 1.1 Applicability. This procedure is applicable for

ISO 2503 INTERNATIONAL STANDARD

DRAFT IN WIDE CIRCULATION Document Despatch Advice

COMMERCIAL ITEM DESCRIPTION NITROGEN, TECHNICAL

This document is a preview generated by EVS

Funsheet [WHAT IS PRESSURE AND TEMPERATURE] Gu 2015

PERFORMANCE SPECIFICATION PROPELLANT PRESSURIZING AGENT, ARGON

ISO INTERNATIONAL STANDARD

ISO/TR TECHNICAL REPORT. Natural gas Calibration of chilled mirror type instruments for hydrocarbon dewpoint (liquid formation)

ISO INTERNATIONAL STANDARD. Gas cylinders Cylinder valves with integrated pressure regulators Specification and type testing

Model: AT-1000 L.P.G. FREEZE VALVE

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

Pharmaceutical Grade Nitrogen & Gardner Denver / CompAir PSA Nitrogen Gas Generation Systems

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

ASTM D86 - Procedural Outline

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

Respiratory Protective Equipment

CHAPTER 5 : THE AIR AROUND US

This standard is due for Five Year Review. This process is required by the SEMI Regulations to ensure that the standard is still valid.

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

Hands-On Experiment Density and Measurement

Measuring Mass and Volume

Calcimeter Instruction Manual

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

17. CARGO MEASUREMENT AND CALCULATION

SOUTH AFRICAN NATIONAL STANDARD

Model: AT-1000 L.P.G. FREEZE VALVE

ISO 407 INTERNATIONAL STANDARD. Small medical gas cylinders Pin-index yoke-type valve connections

This test shall be carried out on all vehicles equipped with open type traction batteries.

Chapter 7. Coal Cargoes. Properties and Characteristics 7.1

Chapter 13 Gases. H. Cannon, C. Clapper and T. Guillot Klein High School. Pressure/Temperature Conversions

Columbus Instruments

PRE LABORATORY ASSIGNMENT: Lab Section Score: /10 READ THE LAB TEXT BEFORE ATTEMPTING THESE PROBLEMS!

FLUORESCENCE DETERMINATION OF OXYGEN

INTERNATIONAL STANDARD

Measuring Carbon Dioxide in Breath

Any laboratory is equipped with specific tools, equipment,

800.Keen.Gas

DETECTION EQUIPMENT - TESTING

Superior Result from Analytical Instruments The constant purity of the nitrogen improves system stability and ensures reproducible results

Unit 11 Gas Laws Chapters 13 of your textbook

Example: 25 C = ( ) K = 298 K. Pressure Symbol: p Units: force per area 1Pa (Pascal) = 1 N/m 2

Exhibit 4. Determination of Static Pressure Performance of the Healy Clean Air Separator (Executive Orders VR-201-N and VR-202-N)

This document is a preview generated by EVS

The Decomposition of Potassium Chlorate

International Civil Aviation Organization DANGEROUS GOODS PANEL (DGP) MEETING OF THE WORKING GROUP OF THE WHOLE. Montreal, 18 to 22 April 2005

This document is a preview generated by EVS

Model PDT Dewpoint Transmitter

What I have learned about SF 6 gas testing.a Practical explanation

Rosemount 3159 Nuclear Qualified Remote Diaphragm Seal

Cryogenics is the science of ultra low temperatures. Low temperatures are achieved by the liquefaction of gases.

Material Safety Data Sheet (MSDS)

Chapter 13 Gases, Vapors, Liquids, and Solids

Experiment 18 Properties of Gases

Working in Gas Hazard Areas

ISO 9597 INTERNATIONAL STANDARD. Cement Test methods Determination of setting time and soundness

Background Statement for SEMI Draft document 4657B NEW STANDARD: SPECIFICATIONS FOR TUNGSTEN HEXAFLUORIDE (WF 6 )

Tex-414-A, Air Content of Freshly Mixed Concrete by the Volumetric Method

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certificate of Secondary Education

11/22/ (4) Harmonization: <846> SPECIFIC SURFACE AREA

Gas Laws. Figure 1: Experimental Set-up with Leveling Bulb. GCC CHM 151LL: Gas Laws GCC, 2019 page 1 of 8

REGISTRATION EXAMINATION, NOVEMBER 2017 TRADESMAN GASFITTER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

Gas Laws. 2 HCl(aq) + CaCO 3 (s) H 2 O(l) + CO 2 (g) + CaCl 2 (aq) HCl(aq) + NaHCO 3 (s) H 2 O(l) + CO 2 (g) + NaCl(aq)

ISO 6570 INTERNATIONAL STANDARD. Natural gas Determination of potential hydrocarbon liquid content Gravimetric methods

Transcription:

CDC 09 (5010) P3 Rev. TZS 217:1984 FINALIZED TANZANIA STANDARD Gaseous oxygen technical grade Specification TANZANIA BUREAU OF STANDARDS. 2 nd edition TBS 2017

0. FOREWORD 0.1. This Tanzania Draft Standard was prepared by the Technical Committee CDC 09 Gases Products under the supervision of Chemicals Divisional Standards Committee, and it is in accordance with the procedures of the bureau. 0.2. In the preparation of this standard assistance was derived from: BS 4364:1968 Specification for industrial oxygen, published by the British Standards Institution, Oxygen Specification, prepared at the 53 rd JECFA (1999), published by FAO in FNP 52 Add 7 (1999), IS 309: 2005 Specification for compressed oxygen gas, published by Bureau of Indian Standards. 0.3. For the purpose of deciding whether a particular requirement of this standard is complied with, the final value observed or calculated expressing the result(s) of a test or analysis shall, be rounded off in accordance with TZS 4:1979 (see clause 2). The number of significant places retained in the rounded off value should be the same as that of the specified value in this standard. 1. SCOPE 1.1. This Draft Tanzania Standard describes the requirements and methods of sampling and test for gaseous oxygen (technical grade) intended for industrial uses e.g. welding and cutting operations. 1.2. This draft Tanzania Standard does not cover oxygen intended for aviation and medical or inhalation uses. 2. Normative references The following normative references are indispensable for the application of this standard. For dated references, only the edition citied applies. For undated references, the latest edition of the normative references (including amendments) applies TZS 4, Rounding off numerical values TZS 59, Water distilled quality Specification TZS 97, Specification for identification of contents of industrial gas cylinders 3. Requirements 3.1. General requirements 3.1.1. Gaseous oxygen of technical grade shall be colourless and odourless. 3.1.2. Gaseous oxygen of technical grade bursts into flame when in contact with the glowing splinter. 3.2. Specific requirements The gaseous oxygen of technical grade shall comply with specific requirements specified in Table 1 when tested in accordance with the methods prescribed therein. 0

Table 1 Specific requirements of gaseous oxygen technical grade S/ No. Characteristic Requirement Test method (i) Oxygen, %, (v/v), min. 99.0 Annex A (ii) Dew drop a), ºC, min. -40 Annex B (iii) Carbon monoxide, v/v, max. Annex C (iv) Carbon dioxide, v/v, max. Annex C (v) Methane b), v/v, max. Annex D NOTE: a) The dew drop test shall be carried out at atmospheric pressure b) Oxygen gas produced by air separation process shall not normally contain any carbon dioxide, carbon monoxide and hydrocarbon in terms of methane. Presence of these impurities in gaseous oxygen of technical grade normally is expected from other methods. 4. Sampling Sampling and criteria of finding conformity of the requirements of this standard shall be done in accordance with method described in Annex E. 5. Packaging and marking 5.1. Packaging The gaseous oxygen of technical grade shall be packaged in compressed gas cylinder(s). 5.2. Marking The marking and labelling shall be in accordance with TZS 97. 6. Quality of reagents Analytical grade reagents and distilled water that comply with TZS 59 or deionized water of equivalent purity shall be used for the appropriate tests. 1

Annex A (Normative) Determination of purity of oxygen gas A.1 Apparatus A.1.1 The apparatus shall be as shown in Figure 1. Figure 1 - Assembly of apparatus for determination of oxygen A- levelling tube B- Burret 2

C- Copper wire container D - Round Flask? E- stockock F - Connector G -Lute H - Stop cock A.1.2 Copper wire A.2 Reagents A.2.1 Ammonia solution Dissolve 550 g of ammonium chloride (NH4Cl) in 1085 ml of water and to this solution add 917 ml of ammonium hydroxide solution of relative density equals to 0.90. A.3 Procedure A.3.1 Invert the copper wire container C, remove the bung and fill it with copper wire in spiral or other form. Then fill it with ammonia solution to replace the bung. Return C to upright position. Pour the ammonia solution into the levelling tube A until it is about three quarters full. Then operate the three-way stopcock E and H so that burette B is in communication with the atmosphere through inlet E, and by raising levelling tube A, completely fill burette B. keeping A raised, turn E, so that B is in communication with C, and allow the solution to pass into C, until D is half full. Close E, lower A and operate E to draw from C into B. close E when capillary of E is full of liquid. Raise A and operate E to expel gas from B to the atmosphere through F, closing E when the capillary H is full of liquid. Fill the lute G with a head of about 50 mm of water and connect F with sample gas and purge the gas from the lute G. Draw in the sample through F (taking care that no air is sucked in through F during this operation), until the liquid level in B is at the zero mark and is at the same level with that in A. Pass the gas into C by suitably operating the cock B, and raising A. shake thoroughly and then draw back the unabsorbed gas into B by lowering A and operating the cock E, until a little solution from the capillary trickles down into B in order to ensure that the capillary plug of cock E is filled with liquid before levelling up and reading the volume of the gas. Repeat the process a number of times until no further absorption takes place. A.3.2 Renewal of the solution When the solution is spent, close E, remove the bung from C and drain out the solution from C and D. Invert C and fill it with fresh solution. Replace the bung and set C and D in proper place and in upright position. Now add fresh solution to the partially spent solution of A and repeat the process as indicated in A.3.1. 3

A.4 Calculation Where: = Volume of the gas sample taken for the test, in ml and, = Volume of the gas after absorption, in ml. 4

Annex B (Normative) Determination of moisture (water vapour) B.1 General Presence of moisture in oxygen gas shall be determined by dew point or by weight of moisture content. For dew point determination, electrolytic hygrometer, frost or dew point hygrometer, and capacitance hygrometer shall be used. For determination of weight of moisture content, absorption method shall be followed. The procedure to be followed for determining the dew point by hygrometer method shall depend upon type of apparatus to be used and manufacturer s instruction. B.2 Electrolytic hygrometer The method is based on absorption and electrolysis if water vapour present in the sample gas. The electrolytic current given a direct measurement of water vapour present in the gas flowing through the instrument at steady rate. The exact procedure to be followed shall depend on the type of apparatus to be used. The instrument manufacturer s instruction in this regard shall be followed. B.3 Frost or dew point hygrometer A metal surface on the hygrometer is cooled so that dew or frost is formed from the vapour content of the gas at a particular pressure which may be observed optically in the apparatus. The temperature at which the dew or frost is formed is a measure of water vapour content of the gas. The exact procedure to be followed shall depend upon the type of apparatus to be used. The instrument manufacturer s instructions in this regard shall be followed. B.4 Capacitance hygrometer The method is based on the change of capacitance of the sensor when a sample gas containing water vapour passes through it. The change in capacitance gives a direct measurement of water vapour present in the gas. The procedure to be followed shall depend on the type of apparatus to be used. The instrument manufacturer s instructions in this regard shall be followed. B.5 Absorption method B.5.1 Apparatus The apparatus consists of the following parts assembled as shown in Figure 2. B.5.1.1 Gas meter, accurate to 1 percent. B.5.1.2 Absorption Train, three U tubes containing phosphorous pentoxide connected in a series to the gas meter. The one near to the gas meter will serve as a guard to prevent moisture from backing into the first tube. 5

B.5.2 Procedure Figure 2 - Assembly of apparatus for determination of moisture B.5.2.1 Absorption of the moisture from a known volume of oxygen gas by anhydrous calcium chloride (CaCl2), or phosphorous pentoxide (P2O5) or Silica Gel or mol. sieve held in a series of U tubes. B.5.2.2 Quantity of gas flow through U tube train shall be measured by a rotometer or any other type of flow meter having accuracy of not less than 5 percent. Flow rate shall be about 500 l/h and not more to ensure complete absorption of oxygen in the hygroscopic chemicals held in the U tube train. B.5.2.3 U tube train filled with hygroscopic chemicals shall be initially heated to 100ºC or more depending on the chemical for 1 h to drive away any moisture absorbed previously by chemicals. The two ends of U tube train shall be firmly closed with rubber stopper not to allow ingress of atmospheric air. Weight of the whole U tube shall be taken on a sensitive chemical balance of accuracy not less than 1 percent. The U tube train shall be heated again in two intervals for 15 min each and weighed again after each 15 minutes heating to see that there is no further moisture from the chemical have been removed. B.5.2.4 At least one cylinder full of oxygen gas at full filling pressure having 6 to 7 m 3 of oxygen gas shall be connected to the U tube train through pressure regulator and flow meter. The entire quantity of oxygen gas from the cylinder shall be passed through U tube train at a rate about 500 l/h and when the cylinder is empty in about 10 h. Both end of the U tube train shall be firmly closed with rubber stopper not to allow any moisture from the air to get in. B.5.2.5 U tube train after absorption of moisture from oxygen gas shall be weighed in a chemical balance and weight of moisture absorbed from oxygen gas shall be found by the difference in 6

weight of the U tube train before commencement of flow off oxygen and after completion of the flow of oxygen. B.5.3 Calculation B.5.3.1 Volume of total oxygen gas flow shall be checked from the flow meter. Alternatively, total quantity of oxygen gas flow can be found out from water capacity of gas cylinder punched on the body of the cylinder and the difference between the initial full pressure of oxygen gas in the cylinder and the final pressure of oxygen in the gas cylinder when flow is stopped. The quantity of gas flow can be found out in the following manner. The water capacity of gas cylinder punched on the body : litre Pressure of the gas cylinder full with oxygen : bar Pressure in oxygen gas cylinder when flow from cylinder is stopped : bar shall be converted to by applying the gas law, If chemical balance employed for weighment is not enough sensitive, in that case gas from more than on oxygen cylinder may be passed to increase absorption of more moisture and thereby to increase the weight of the U tube train for easier weighment. B.5.3.2 The weight of moisture absorbed in the U tube train in grams divided by the volume of oxygen passed in Nm 3, shall show moisture content, in g/nm 3. B.5.3.3 The above test shall be repeated 3 times and the average moisture content in g/nm 3 shall be determined. This shall not be more than 0.102 g/nm 3 corresponding to -40ºC dew point. 7

Annex C (Normative) Determination of volume fraction of carbon monoxide and carbon dioxide C.1 The method for determination of volume fraction of carbon monoxide and carbon dioxide present in oxygen shall use the principle of infrared absorption in specific wavelength by different molecules. Scanning infrared spectrometer shall be used after calibration. Instruction of the manufacturers of the instruments shall be followed for calibration and calculation of volume fraction of carbon monoxide and carbon dioxide. C.2 Alternatively, pass 1050 ± 50 ml of the gas sample through carbon monoxide or carbon dioxide detector tube at the rate specified for the tube, depending on what you are measuring at that particular moment. For carbon monoxide, the indicator change shall not correspond to more than 10 µl/l while for carbon dioxide shall not correspond to more than 300 µl/l. 8

Annex D (Normative) Determination of volume fraction of hydrocarbons D.1 Gas chromatograph with flame ionization detector, gas sampling valve, suitable valve to backflash hydrocarbon to detector shall be used for determination of volume fraction of hydrocarbon. Nitrogen gas shall be used as carrier gas. Instruction of the manufacturer of the instrument shall be followed for calibration and calculation of volume fraction of hydrocarbons in oxygen gas. 9

Annex E (Normative) Sampling of gaseous oxygen of technical grade E.1 Procedure E.1.1 On regular production, two samples selected at random shall be tested per hour of compression. E.1.1.1The production shall be declared as conforming to this standard, if the sample passes the oxygen and moisture content test. E.1.1.2 However, if the sample fails in the oxygen and moisture content test, then sampling frequency shall be doubled until all samples pass for consecutive 2 h. 10

Annex F (Informative) Determination of odour F.1 Carefully open the container valve to produce moderate flow of gas. Do not direct the gas stream towards the face, but deflect portion of the stream toward the nose: no appreciable odour shall be discernible. 11