UCT OPERATING MANUAL UCT POSITIVE PRESSURE MANIFOLD.

Similar documents
Gema s OptiColor System

APCF1 Model Tripod.

INSTALLATION INSTRUCTIONS

URGENT MEDICAL DEVICE RECALL : /29/ C Z

WORKSTATIONS mysite User Guide. mysite Workstation System User Guide

WA270 Water Broom Important Safety Instructions Assembly Operation Maintenance Service Information

A Guide to Relocating Hazardous Materials

Rev B Medivators Inc.

Large Diameter TECTITE Installation and Specifications Manual

Sponge-Jet Continuous VAC- Recovery System User Manual

Fume Hood User Guidelines

Down and Out Mount Assembly & Installation Directions

Installation Manual for VersaScreen Pro and VersaScreen IceBlaster Gutter Protection Products. Table of Contents

Plain Language Summary

Nordson AP-300/600 Plasma Systems Operational Manual July 2017

Complex Care Hub Manual: High Flow Nasal Prong (HFNP) Oxygen Therapy

Sponge-Jet Media Recycler User Manual

How to Install a Toilet By See Jane DrillTM Copyright 2013, All Rights Reserved

Content. Support Pack. Support Pack

Field Instruction. 5.2 Poles Inspection and Support Prior to Commencement of Work

Management: Shop Coordinator, Shop Supervisor and Fire Safety Staff

patient education program 4156 South 52 nd Street, Omaha, NE ChildrensOmaha.org/HomeHealthcare

General Industry Toolbox Talks. Providing Excellence in Regulatory Compliance Management Systems

BaseStation 1000 Irrigation Controller Keeping a Pond or Cistern Full

CONFINED SPACES SAFETY & HEALTH ISSUES AND REGULATORY COMPLIANCE

Livermore Harley Owners Group RIDING WITH LIVERMORE HOG

Black Brant Vb. Please read and understand all instructions before building!

OPERATIONS CHALLENGE 2017

Winthrop University - Safety in the Chemistry Laboratory

Tubing Group Guide. Wilmot Mountain Tubing, a Vail Resorts Company Fox River Rd. Twin Lakes, WI 53181

Concept 305 P. Pre-installation Guide IMPORTANT!

SPARC Match Rules v1.2

Standard Operating Procedure

Guidelines for Handling of Nuclear Gauges

Weather Balloon Altitude Control System. Tim Basta, Trevor Clark, Scott Miller Date: 9/15/2014

CITY OF SACRAMENTO. Regulatory Compliance Program

EDS Instruction Manual

SAFE WORK METHOD STATEMENT FOR: Maintlink PTY LTD

Let s explore and find what works!

Lab rotation on vacuum techniques and thermal imaging

243 Service Regulators

Urinalysis Collection Odyssey House of Utah

Owner: USA Division Safety Revision No: 00 Date last revised: 01/14/2013

GALENA FIRE DEPARTMENT Standard Operating Guideline ICE AND WATER RESCUE. Fire Chief Signature

Slim Down and Out Swivel Mount Assembly & Installation Directions

SENIOR STARS HOCKEY LEAGUE

Brazed Plate Heat Exchanger Operating & Instruction Manual U K Exchangers Ltd Unit 55, Stilebrook Road Olney Buckinghamshire MK46 5EA

Fundamentals of Successful Pole Vaulting Anthony Bertoli University of Northern Iowa

Sponge-Jet Feed Unit User Manual

Kennecott Utah Copper Corporation Safety and Health Standards

CELEBRATING 12 YEARS OF WINDSOR CHEER!! WHY CHOOSE NORTHSTAR CHEER? scheduled to become the next new addition to the Olympics!

Lab Pilot Fermenter Type LP351, 75 Liters OPERATING INSTRUCTIONS

Exposure Control Plan

!! 1st/ 2nd Grade. 3rd Grade

Policy and Procedures

Winthrop University - Safety in the Chemistry Laboratory

WELCOME MESSAGE. Welcome to the 2016 Hub City Hustle Triathlon!

PULSAR ZERO Flow sensitive Unloader valve

Exercise 2: Reviewing the Workplace Inspection Checklist (30 min) p

Cantilever Beam Bending of Soft Tissue

MECHANICS & TECHNIQUES 3PO

Pressure reducing valve. Type UZRB6

Come Back to Ground! 1. Introduction

Swim Around Lido Key Saturday, April 22, 2017 Race and Safety Plan

Care and Maintenance of Polytan STI Athletics Surfaces

Liquid Nitrogen (LIN) Supply and Safety Plan. May 30, 2018

Let s go through the mechanics of air resistance that way we can understand why an aero helmet may be a good option for someone.

Confined Space Entry

V O L L E Y B A L L C A R N I V A L

Description: Model Number: Robinhood Canopy RHCVI9G

Check the medication record to see what medicine is due at that time;

Technical Data Sheet EW1 Top coats

MODELS. 2 & 4 Versions. SUITABLE FOR WET LOCATIONS in the following locations or unclassified locations:

A Quick Guide to Laboratory Safety Inspections At NMT

Hot Work Policy and Procedures

Field Instruction. Refer to General Safety Requirements in FI 10.6 Vegetation Management Work.

INSTRUCTIONS Sanctioning a 3PAR Competition

Pro HD. Introducing the Pro HD blokart, developed specifically for Rental / Commercial operators.

Technical Documentation

PRE-FILL INSPECTION OF CUSTOMER OWNED CYLINDERS

Visit Leader Emergency Action Card

Warranty & Service Information Proprietary Notice: Limited Warranty: Service Support:

LARZEP, S.A. LARZEP AUSTRALIA PTY. LTD.

Prospect Park Baseball Association PEE WEE DIVISION RULES Revised January, 2011

Hazard Assessment and Respiratory Protection Reference Guide (OSHA)

Espa Pumps (UK) Ltd Riverside Avenue West Lawford, Manningtree Essex CO11 1UN

Demonstrate the capability to carry out emergency response functions in an unannounced exercise or drill.

2016 AWWA/WEA Spring Conference ACTUATORS AND VALVE TECHNOLOGY/ ACTUATOR SIZING SCOTT J. OLIVER CAROTEK, INC. APRIL 2016

Arterial and Venous Patient Training Arm

PMI Advanced Media Bubble Point Tester

Ball coupling FIRG / FIRG-Q

Complex Care Hub Manual: Basic Life Support for Children with a Tracheostomy

All Students MUST fly with the assistance of a Club approved Instructor until such time as he/she has passed his/her Wings Test.

Technical Data Sheet DW1 Undercoats

RBC Canadian Open. Practice Facility. RBC Canadian Open. 1 Championship Manual

Installing the ACT D MAND KONTROLS Systems

There are a number of different types of feeding tubes. These include a:

Instructions for use. turbomax pro 24 E 28/2 E

Note: Other Divisions (ex: Research Operations) may have additional or more stringent requirements in addition to this procedure.

Opportunity for Public Participation. Plain Language Summary

Transcription:

FORENSICS OPERATING MANUAL 1 2731 Bartram Rd Bristl, PA 19007 USA POSITIVE PRESSURE MANIFOLD

POSITIVE PRESSURE MANIFOLD MANUAL POSITIVE PRESSURE EXTRACTION OPERATION INSTRION Thery f Operatin 2 The Psitive Pressure Extractin Manifld (PPM) is a mechanical wrkstatin that is used t facilitate the prcess f sample preparatin using slid phase extractin (SPE) cartridges. The PPM utilizes pressurized gas (i.e. cmpressed nitrgen r air) t mve sample slvent thrugh SPE cartridges at a cntrlled rate f flw. The PPM has tw (2) adjustable regulatrs designed with restrictrs t allw a fine (lwer) (Regulated Flw) and a carse (higher) (Dry / Full Flw) adjustment during the extractin prcedure. SHIPPING CONTENTS (1) 4 x 12 psitin Psitive Pressure Manifld (1) Waste cllectin rack, stpcck and tubing (1) Elutin rack (16 mm r 13 mm cllectin tubes) (1) ¾ 4 x 12 psitin Slid Phase Extractin plate (Standard 10 ml/15 ml rack included with each system. See page 10 fr available adaptr plates). ACCESSORIES REQUIRED FOR OPERATION ¼ O.D. plastic rigid tubing rate fr a minimum f 80 t 100 psi. Gas surce (Nitrgen r Air). ¼ cmpressin fitting fr attachment t gas surce. In-line gas filter (ptinal - suggested if using unfiltered cmpressed gas.) 2731 Bartram Rd Bristl, PA 19007 USA

DESCRIPTION OF PPM UNIT & CONTROLS Dimensins f unit: The psitive pressure manifld is 16.25 wide, 13 deep, and 20 high. The Raise and Lwer switch is used t put the extractin rack int prper psitin during sample preparatin. The pressurized gas will mve the slid black plastic extractin rack up r dwn depending n the switch psitin. 3-Psitin Tggle Switch This switch is used t adjust the flw mechanism t ne f the three (3) desired psitins (Regulated, Off, r Dry/Full). By turning the knb t each psitin, the PPM will allw the rate f flw thrugh the manifld plate as adjusted and shwn n the pressure gauge. Regulated Flw Adjustment This gauge is cnsidered a fine adjustment because it has a restrictr, which will nt allw excessive flw thrugh the manifld plate. The adjustment knb is used t regulate the flw during the extractin prcedure. 3 T adjust, pull the knb ut and turn clckwise t increase and cunterclckwise t decrease the gas flw t the desired rate. Push the knb in t lck the adjustment knb int psitin. By turning the center tggle switch t Regulated Flw the gas will begin t flw at the rate in relatin t the pressure gauge under the adjustment dial. (It is recmmended t use 80-100 psi gas flw frm the main gas surce t maximize the PPM efficiency. The regulated flw shuld be adjusted t apprximately 10-20 psi t btain a rate f flw between 1-2 ml/ minute.) POSITIVE PRESSURE MANIFOLD (Nte: This is a guideline; an actual flw setting must be made since the rates thrugh the clumns culd change based n surce gas pressure, srbent type, srbent amunt, extractin fluid, sample matrix, etc.) 2731 Bartram Rd Bristl, PA 19007 USA

POSITIVE PRESSURE MANIFOLD MANUAL Dry/ Full Flw Adjustment This gauge is used t maximize the amunt f gas flw thrugh the PPM and extractin tubes. There is a wider range flw restrictr assciated with this gauge that allws a larger vlume f gas t flw at a higher rate thrugh the PPM. This setting is used during the drying step r when higher flw rates are required fr samples due t sample matrix r prcedure requirements. The adjustment knb is used t regulate the flw during the extractin prcedure. T adjust, pull the knb ut and turn clckwise t increase and cunterclckwise t decrease the gas flw t the desired rate. Push the knb in t lck the adjustment knb int psitin. By turning the center tggle switch t Dry/ Full Flw the gas will begin t flw at the rate in relatin t the pressure gauge under the adjustment dial. 4 Rw Tggle Switches These switches are used t turn On/Off the flw t rws 2-4. The rws 2-4 can be turned On/Off as desired during the extractin prcedure. The switch fr rw 1 is munted n the back f the unit. This allws fr n / ff cntrl fr rw 1. The rws are cunted 1-4 starting frm frnt t back facing the PPM. The rate flw thrugh each rw is determined by the tggle switch set t Regulated, Dry/Full r Off. 2731 Bartram Rd Bristl, PA 19007 USA

USING THE MANIFOLD FOR EXTRACTION After cnnecting the ¼ inch gas line t the back f the manifld (quick hse cnnect), adjust the pressure t between 80-100 psi frm the gas surce. Befre putting n the manifld racks and plates, test the maniflds supprt arms by switching the Raise / Lwer tggle switch. The black supprt arms shuld raise and lwer as the tggle switch is adjusted. There will be a lw hissing sund frm the pneumatic pistn system. The manifld waste rack is fitted with a drain and stpcck / hse assembly t be used t cllect waste during the extractin prcedure.the waste cntainer has tw pin cnnects n the underside that fit int the tw screw tps n the manifld rack. This will ensure the stability f the waste rack when the rack is mved during the extractin prcess. The clumn plate (e.g. ¾ metal plate with 4 x 12 drilled penings) is placed n the tp prtin f the rack. These reversible plates are als pre-drilled t fit nt the tp f either the extractin r cllectin rack with the psitin pins. 5 With the waste cntainer and tp plate in place, psitin the rack n tp f these black supprt arms and easily slide int and ut f the wrking manifld psitin. There are als tw pins n the frnt f the black supprt arms. These pins are psitined s as t nt allw the rack t cme ff the supprt arms during the extractin prcedure. An imprtant pint regarding the manifld rack: There are handles n either side f the extractin / cllectin rack fr gripping the racks fr psitining and remval. These racks will nly fit prperly int the wrking manifld if the handle psitins are frward t the frnt f the manifld. It becmes bvius if it is incrrectly placed n the black supprt arms because the 4 x 12 frit penings n the underside f the chassis will nt align prperly with the extractin clumns. 2731 Bartram Rd Bristl, PA 19007 USA

POSITIVE PRESSURE MANIFOLD MANUAL MAINTENANCE OF MANIFOLD The manifld requires regular upkeep t preserve the full functinality f the unit. Daily cleaning f any slvent r spills (as needed) n any f the manifld surfaces is suggested. Use slvents such as Methanl, Water, r Is-prpanl t wash the surface f the manifld. It is recmmended t use water first fllwed by an alchl t help dry the unit. Ensuring clean air (free f il, water, and particulates) is imprtant t the maniflds prper functin. The in line air filter (Part Number VMFPPMRAF) attached t the back f the manifld shuld be mnitred fr cndensatin r ther cntaminatin issues. If the filter lks wrn r filled with water, replacement may be required. The brwn rubber gaskets (VMFPPMGSKBL) n the underside f the manifld are recmmended t be replaced at least tw (2) times a year. (A) 6 (B) T replace these gaskets simply peel back the ld gasket frm the bttm f the manifld. Then cntinue by remving the plastic peel frm the bttm f the gasket and attaching the gasket t the bttm f the frit plate. (A) (B) If any psitin n the manifld becmes clgged it may be necessary t replace the restrictr plate. T replace the restrictr plate, turn the manifld upside dwn and remve the base plate. Peel back the brwn gasket frm the frit plate. Lsen the 12 screws with a Phillips screw driver r pwer drill. Remve the restrictr plate by simply pulling it ff f the manifld. (Nte it may be necessary t use a flat head screw driver t pry up the plate if it is nt separating frm the manifld). Replace the range gasket n the tp f the new restrictr plate. Clean as much f the remaining adhesive with a razr t get a gd seal f the range gasket. It is best t attach this directly t the frit plate befre re-securing it t the manifld. Place the restrictr plate back n the unit by replacing the 12 screws. (D nt ver tighten screws). Replace the brwn rubber gasket n the bttm f the restrictr plate making sure the hles n the gasket line up with the hles n the manifld. If the lift arms are hesitating r nt mving freely, lubricate the pistn inside the back f the unit with either silicne grease, r sme ther type f metal lubricant. This will help insure prper mvement f the lift arms. 2731 Bartram Rd Bristl, PA 19007 USA

REPLACEMENT PARTS AND ACCESSORIES Descriptin Adapter extractin plate t accmmdate 1 ml extractin tubes. Adapter extractin plate t accmmdate 3 ml extractin tubes. Adapter extractin plate t accmmdate 6 ml extractin tubes. Installatin kit (25 ft ¼ O.D. tubing, in line air filter, 2 - ¼ cmpressin fittings Waste cntainer - wastebin with draining kit (10 ft tubing + stpcck) 16 x 100 mm elutin rack 13 x 100 mm elutin rack. Replacement in line air filter Replacement clumn sealing gasket (brwn) Replacement clumn sealing gasket (range) Arm Restrictr Plate Lift Plate Part Number VMFPPMRKA1 VMFPPMRKA3 VMFPPMRKA6 VMFPPMIK VMFPPMWBND VMFPPMCRKG16 VMFPPMCRKG13 VMFPPMRAF VMFPPMGSKBL VMFPPMGSKOR VMFPPMARM VMFPPMFRPLT VMFPPMLPLT 7 2731 Bartram Rd Bristl, PA 19007 USA

POSITIVE PRESSURE MANIFOLD MANUAL 8 PRICES AND TERMS Our prices are subject t change withut ntice. The price in effect when we receive yur rder will apply. All prices are in US Dllars and are F.O.B. Lewistwn, PA 17044. Terms f payment are net 30 days. MINIMUM ORDERS We welcme all rders, therefre, we d nt have a minimum rder requirement. When rdering, please include yur purchase rder number, cmplete Ship T and Bill T address, catalg number, quantity, and descriptin f prduct(s). Als include yur name and a phne number where yu can be reached shuld we have any questins cncerning yur rder. SHIPMENTS Nrmal prcessing is within 24 hurs after receipt f an rder. Unless special shipping requests have been made, ur trained staff will send all rders by UPS Grund service. The apprpriate shipping charges (freight & insurance csts) will be added t the invice, unless therwise instructed by the custmer. SPECIAL PRICING We ffer special pricing fr vlume purchases and standing rders. These discunts apply t bnded phase extractin clumn purchases nly. Please call a sales representative fr mre infrmatin n special pricing qualificatins. WARRANTY PROGRAM After the initial 90 day perid, a service agreement with can be arranged. The service agreement will entail the fllwing: Upn the need fr repair, the wner f the manifld will submit an pen PO t fr repair. will ship a temprary laner manifld (at n charge) t the custmer t be used until their manifld can be repaired. The ttal cst f shipping t and frm s facility fr the custmer s manifld will be the respnsibility f the custmer The ttal cst f parts needed t repair manifld(s) will be the respnsibility f the custmer The ttal cst f shipping f the laner manifld will be incurred by will perfrm a thrugh inspectin f the manifld which at minimum will include: Cntact Us Each psitin f the individual (4) plates f the PPM will be checked fr flw thrugh. If there is significant restricted flw t any f the sample psitins, the plate will be cleaned and re-tested. The pistn s lubricatin will be checked t insure prper peratin. The gaskets will be examined fr wear r fracturing. The individual plates will be inspected fr any lse screws hlding the plates t the bdy f the manifld. Any additinal maintenance r repair beynd the scpe f this agreement will be charged at the discretin f, LLC. RETURN POLICY Our Quality Manager will handle all returns. Befre returning merchandise, please call t btain a return authrizatin number frm the quality manager. We will need t knw the reasn fr the return, date f purchase, purchase rder number and invice number in rder t issue a return authrizatin number. Return merchandise must be received befre a credit can be issued. Returns will nt be accepted after 90 days. A restcking fee f 25% f the price paid, r a minimum f $25.00 (whichever is greater) will be charged n all returns. SAFETY This equipment, when used prperly, is safe. Prper PPE, as determined by yur rganizatin, shuld be wrn at all times while using this equipment. Prper handling techniques fr chemicals and bilgical agents shuld be fllwed at all times. Cmpressed gas r nitrgen is used t perate the equipment. Cmpressed gas r nitrgen tubing shuld be securely fitted and lcked int the equipment t prevent the cmpressed gas r nitrgen tubing frm lsening and ptentially striking the peratr. Cmpressed gasses and equipment shuld be handled under prper ventilatin t prevent xygen displacement r txic atmspheres. Operatrs f this equipment must be aware f the pssible pinch pints. Pinch pints are lcated n the restrictr plate, as it is raised and lwered and n the waste tray and extractin plate pints f cnnectin. Phne: 215.781.9255 800.385.3153 Fax: 215.785.1226, Inc. 2731 Bartram Rd. Bristl, PA 19007 Email: inf@unitedchem.cm Web: 2731 Bartram Rd Bristl, PA 19007 USA 7109-03-01 FORENSICS