FireLock NXT Dry Valve. System No. Submitted By Spec Sect Para Location Date Approved Date FIRE PROTECTION PRODUCTS DEVICES

Similar documents
FireLock NXT Dry Valve. System No. Submitted By Spec Sect Para Location Date Approved Date

FireLock NXT Preaction Valve with Series 798 Pneumatic/Pneumatic Actuator

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q= Cv S

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

I-769P.AC/ELEC.PNEU FireLock NXT AutoConvert Preaction Valve

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Dry 132a. October 1, 2008

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50)

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA OBSOLETE

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE. 4. TECHNICAL DATA Approvals:

TECHNICAL DATA DELUGE VALVE, MODEL F-1 STRAIGHT THROUGH STYLE

GENERAL DESCRIPTION MODEL RCW DRY SYSTEM CONFIGURATION. Technical Support Airpark Dr. Standish, MI 48658

TECHNICAL DATA. than the water inlet pressure to the concentrate

TECHNICAL DATA. Notes: For use with Trim Charts on Pages 2-4

TECHNICAL DATA. System water supply pressure enters the priming chamber of the deluge valve (A.1) through the 1/4 (8 mm) priming line, which

MODEL RCW DRY SYSTEM VALVE

TECHNICAL DATA. Trimpac 257a. September 16, 2013

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA. Trimpac 256a. October 31, 2013

TECHNICAL DATA CAUTION

GW DRY PIPE VALVE INSTALLATION & OPERATION 100mm (4 ) 150mm (6 )

TECHNICAL DATA. Trimpac 244a. September 16, 2013

TECHNICAL DATA ACCELERATOR MODEL E-1

TECHNICAL DATA. Deluge Valves 211a. November 30, 2007 DELUGE VALVE MODEL E-1 ANGLE STYLE 3 (DN80), 4 (DN100) & 6 (DN150)

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

TECHNICAL DATA. Deluge Valves 218a. November 30, 2007 DELUGE VALVE MODEL F-1 STRAIGHT THROUGH STYLE 2-1/2 (DN65) - 8 (DN200)

Wet pipe low flow foam/water system

TotalPac X Single interlock Preaction system Electric release

Features. Model DDX-LP Dry Pipe Valve System 2 (50 mm), 2½ (65 mm), 3 (80 mm), 76 mm, 4 (100 mm), 6 (150 mm), 165 mm & 8 (200mm) Listings & Approvals

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

MODEL RCW NON-INTERLOCK PREACTION SYSTEM

Data Sheet Issue A

End Connection. Thread x Thread N/A N/A N/A N/A Flange x Flange N/A

Model DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction.

Features. Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

Technical Data. UL Listing is based on the following criteria:

Worldwide Contacts. End Connection

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

MODEL UM UNIVERSAL MANIFOLD ASSEMBLY (With or Without Control Valve) 1¼", 1½", 2", 2½", 76.1mm, 3", 4", 6",165.1mm, 8"

Features. Model EX Low Pressure Dry Pipe Valve System 2 (DN50), 2½ (DN65), 3 (DN80), 76 mm, 4 (DN100 ), 6 (DN150), 165 mm & 8 (DN200)

TECHNICAL DATA OBSOLETE

Model DPV-1 Dry Pipe Valve External Resetting. General Description. Technical Data. Page 1 of 20 AUGUST 2018 TFP1020. Worldwide Contacts

TECHNICAL DATA OBSOLETE

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

Horizontal Bladder Tanks

TECHNICAL DATA. Trimpac 247a_Euro. September 16, 2013

Vertical Bladder Tanks

TECHNICAL DATA. Page 1 of 12

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY PNEUMATIC RELEASE. 1. DESCRIPTION (Refer to Figures 1, 2 or 3.

BERMAD Waterworks. Pressure Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

V43 Pressure Actuated Water Regulating Valve

TECHNICAL DATA CAUTION

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

Model MTB-ASME Horizontal Bladder Tanks

BERMAD Waterworks. Pressure-Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features

MODEL UMC UNIVERSAL MANIFOLD CHECK ASSEMBLY

VERTICAL BLADDER TANK

Model MTB-ASME Vertical Bladder Tanks

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Preaction System with DV-5 Deluge Valve Single Interlock, Supervised Wet Pilot Actuation 1-1/2 thru 8 Inch (DN40 thru DN200) General Description

Model MTB-ASME Vertical Bladder Tanks

MODEL UMC UNIVERSAL MANIFOLD CHECK ASSEMBLY

FIRE PROTECTION PRODUCTS

OBSOLETE. Wet pipe low flow manifold system

HORIZONTAL BLADDER TANK

TECHNICAL DATA Q= C. Table 1 - Specifications

Type 1098-EGR. Pilot-Operated Valve Link Regulators. Features. Fisher Controls

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

a pilot sprinkler were to be closed after its initial operation, for example a remote manual control station).

Anti-flood device Model B-1

FIRE SPRINKLER PRODUCTS PRODUCT CATALOG

Bermad Pressure Reducing. Model: 42T

Worldwide Contacts.

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

TECHNICAL DATA. Table 1 - Specifications

Models 106-RF / 206-RF Rate of Flow Control Valve

BEFORE SALES AFTER SALES

Installation, Operation and Maintenance Manual for Back Pressure Regulator

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

Instructions for Installation, Operation, Care and Maintenance

The TYCO Model PRV-1 Pressure. Reducing Valves described herein must be installed and maintained in compliance with this document and with the

WaterSource Heat Pump Hose Kit Performance Specification-Summary

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

NOTICE The Model DPV-1 Dry Pipe Valves and

1 Exam Prep. Tabs and Highlights

MWEA MAINTENANCE SEMINAR SPECIALTY VALVES POWER GLOBES

Speed control assembly model A-1

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Preaction System with Model DV-5 Deluge Valve Single Interlock, Supervised Dry Pilot Actuation 1-1/2 thru 8 Inch (DN40 thru DN200)

Transcription:

* * * * ME: 248-98-E CSFM: 7770-0531-117 VNIIPO The patent-pending Victaulic Series 768 FireLock NXT is a low differential, latched clapper valve that uses a unique direct acting diaphragm to separate system water supplies from dry-pipe sprinkler systems. * see page 12 for European trim PTENT PENDING FETURES Clapper Latch Clapper Seal Seat Exaggerated for clarity Diaphragm ssembly Note: Valve is shown in the set position The low differential, unique latch and actuator design of the valve allows the valve to be reset without opening the valve. The low differential design is not subject to water columns. The valve allows the water to operate a water motor alarm and/or electric pressure alarms, which continue until the flow of water stops. With the optional accelerator, the valve can be configured to respond faster for use in larger systems, or where faster response times are required. The valve is rated to 300 psi/2065 kpa water working pressure and is factory tested hydrostatically to 600 psi/4135 kpa for sizes 1 1/2 8"/40 200 mm. VdS trim configurations are approved to 16 BR (see page 12). Required air pressure for all trim variations is 13 psi/90 kpa. The Series 768 is available grooved x grooved. Standard grooved dimensions conform to NSI/ WW C606. The Victaulic Series 768 FireLock NXT is made of high-strength, low-weight ductile iron, and it offers easy access to all internal parts. ll internal parts are replaceable. Maintenance and service can be performed without removing the valve from its installed position. The rubber clapper seal is replaced easily without removing the clapper from the valve. The valve is painted inside and out to increase corrosion resistance. The body is tapped for main drain and all available trim configurations. Installation Options The Victaulic Series 768 FireLock NXT is available bare, or in the following configurations: Pre-trimmed The pre-trimmed valve comes completely assembled with all necessary trim components. Vic-Quick Riser The Vic-Quick Riser comes completely pre-trimmed and includes a shut off valve (uses a Series 705W FireLock Butterfly valve request publication 10.18; for 1 1/2 and 2"/40 and 50 mm sizes, the Vic-Quick Riser comes with a Series 728 Ball Valve request publication 10.17) for system shut off, pre-set pressure switches, and a drain kit for ease of installation. For complete Vic-Quick Riser information request publication 30.20. Series 745 FireLock Fire-Pac (vailable in North merica only) The Fire-Pac is a completely pre-assembled fire protection valve that provides maximum service in a minimal enclosed space. The unit includes a water supply shutoff valve, the sprinkler system fire protection valve, alarm line pressure switches, air supervisory pressure switches, supervisory pump switches, and digital pressure gauges that are easily viewed through a window in the cabinet door. For complete Fire-Pac information request publication 30.23. Optional accessories ship separately. JOB/OWNER CONTRCTOR ENGINEER System No. Submitted By Spec Sect Para Location Date pproved Date 1

DIMENSIONS THE 4 INCH/114.3 MM UL LISTED, FM PPROVED CONFIGURTION IS SHOWN BELOW 1 1/2 2"/48.3 60.3 MM CONFIGURTIONS CONTIN 3/4"/19 MM DRIN VLVES. 2 1/2 3"/73.0 88.9 MM CONFIGURTIONS CONTIN 1 1/4"/31 MM DRIN VLVES. 4 8"/114.3 219.1 MM CONFIGURTIONS CONTIN 2"/50 MM DRIN VLVES. G E F D *D1 *B1 *1 B J H C Full Open K *E1 Nominal Size Inches/ mm Size Dimensions inches/mm ctual Outside Diameter Inches/ mm 1 B B1 C D D1 E E1 F G H J K prx. Weight Ea. lbs/kg 1 ½ 1.900 9.00 16.43 27.25 39.50 13.75 16.00 5.25 8.50 9.50 21.25 3.04 9.17 6.98 16.7 43.0 40 48.3 228.60 417.32 692 1003 349 406 133 215 241 539 77.21 232.91 177.29 7.6 19.5 2 2.375 9.00 16.43 27.25 39.50 13.75 16.00 5.25 8.50 9.50 21.25 3.04 9.17 6.98 17.0 43.0 50 60.3 228.60 417.32 692 1003 349 406 133 215 241 539 77.21 232.91 177.29 7.7 19.5 2 ½ 2.875 12.61 16.50 32.25 44.25 13.50 16.00 17.50 5.25 9.00 9.25 21.25 3.90 10.50 6.93 41.0 65.0 65 73.0 320.29 419.10 819 1123 342 406 444 133 228 234 539 99.06 266.70 176.02 18.7 29.5 76.1 mm 3.000 12.61 16.50 32.25 44.25 13.50 16.00 17.50 5.25 9.00 9.25 21.25 3.90 10.50 6.93 41.0 65.0 76.1 320.29 419.10 819 1123 342 406 444 133 228 234 539 99.06 266.70 176.02 18.7 29.5 3 3.500 12.61 16.50 32.25 44.25 13.50 16.00 17.50 5.25 9.00 9.25 21.25 3.90 10.50 6.93 41.0 65.0 80 88.9 320.29 419.10 819 1123 342 406 444 133 228 234 539 99.06 266.70 176.02 18.7 29.5 4 4.500 15.03 19.78 33.50 45.50 15.00 15.75 20.50 5.25 9.00 10.75 21.00 6.25 9.62 8.46 59.0 95.0 100 114.3 381.76 502.41 850 1155 381 400 520 133 228 273 533 158.75 244.34 214.88 26.7 43.0 165.1 mm 6.500 16.00 22.00 34.00 46.00 15.50 17.00 22.00 5.25 8.50 11.50 20.50 6.20 9.62 8.84 80.0 116.0 165.1 406.40 558.80 863 1168 393 431 558 133 215 292 520 157.48 244.34 224.53 36.2 52.6 6 6.625 16.00 22.00 34.00 46.00 15.50 17.00 22.00 5.25 8.50 11.50 20.50 6.20 9.62 8.84 80.0 116.0 150 168.3 406.40 558.80 863 1168 393 431 558 133 215 292 520 157.48 244.34 224.53 36.2 52.6 8 8.625 17.50 22.94 33.50 45.50 16.75 20.00 25.25 6.25 8.75 12.75 18.50 6.05 9.40 10.21 122.0 158.0 200 219.1 444.50 582.67 850 1155 425 508 641 158 222 323 469 153.67 238.76 259.33 55.3 71.6 NOTES: The dimension coupling is not shown in order to clarify dimensional callouts. Components shown as dotted lines denote optional equipment. * Measurements denoted with an asterisk take optional equipment into account. Optional drain connection kit is shown for reference and takeout dimensions. Without Trim With Trim _2

PERFORMNCE Hydraulic Friction Loss The chart below expresses the flow of water at 65ºF/18ºC through a full open valve. 6.0 5.0 4.0 PRESSURE DROP PSI 3.0 2.0 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 1½"/40mm 2"/50mm 2½"/65mm and 76.1mm 3"/80mm 4"/100mm 8"/200mm 6"/150mm and 165.1mm 0.2 0.1 10 20 30 40 60 80 100 200 300 400 600 1,000 2,000 4,000 6,000 10,000 20,000 800 3,000 8,000 FLOW RTE GPM Frictional Resistance The chart below expresses the frictional resistance of Victaulic Series 768 FireLock NXT in equivalent feet of straight pipe. Nominal Size Inches/ mm Size ctual Outside Dia. Inches/ mm Equivalent Length of Pipe Feet meters 1 ½ 1.900 3.00 40 48.3 0.914 2 2.375 9.00 50 60.3 2.743 2 ½ 2.875 8.00 65 73.0 2.438 76.1 mm 3.000 8.00 76.1 2.439 3 3.500 17.00 80 88.9 5.182 4 4.500 21.00 100 114.3 6.401 165.1 mm 6.500 22.00 165.1 6.706 6 6.625 22.00 150 168.3 6.706 8 8.625 50.00 200 219.1 15.240 _3

C v VLUES C v values for flow of water at +60 F/+16 C through a fully open valve are shown in the table below. Formulas for C v values: P = Q 2 C v 2 Q = C v x P Where: Q = Flow (GPM) P = Pressure Drop (psi) C v = Flow Coefficient Size Nominal Size Inches/ mm ctual Outside Dia. Inches/ mm C v /K v (Fully Open Valve) 1 ½ 1.900 60 40 48.3 52.0 2 2.375 110 50 60.3 95.0 2 ½ 2.875 180 65 73.0 156.0 76.1 mm 3.000 180 76.1 156.0 3 3.500 200 80 88.9 173.0 4 4.500 350 100 114.3 302.8 165.1 mm 6.500 1000 165.1 865.0 6 6.625 1000 150 168.3 865.0 8 8.625 1500 200 219.1 1499.1 OPERTION The Series 768 contains a clapper, which has a replaceable rubber seal. The clapper makes contact with the valve s seat ring, which has access holes leading into an intermediate chamber in the valve. The diaphragm contacts the latch, and the latch holds the clapper closed. In the closed position, the valve diaphragm is maintained in the extended position by the water supply pressure from upstream of the water supply control valve. The diaphragm latch holds the clapper in the closed position. The Series 776 Low Pressure ctuator (LP) maintains the water, and the system s air pressure controls the LP. Required air pressure is 13 psi/90 kpa. The design of the 776 actuator does not require the traditional air cushion of 10 20 psi/69 138 kpa. Excess air pressure above 13 psi/90 kpa will cause a delay in valve operation. Once the system s air pressure reduces to the trip point, the LP opens and allows the water supply pressure in the diaphragm to release (i.e. an open sprinkler). This release allows the latch to move to its open position, permitting the clapper to pivot freely, thus allowing water into the system. Water enters the intermediate chamber of the valve through the holes in the seat ring. The water flows from the intermediate chamber to the alarm line, which activates the system s alarms. The alarms continue to sound until the flow of water stops. When the flow of water stops, the spring-assisted valve clapper returns to the closed position. The valve acts as an alarm check valve until the system is back in service as a dry system, according to the proper procedure. _4

MTERIL SPECIFICTIONS Body: Ductile iron conforming to STM -536, grade 65-45-12. Ductile iron conforming to STM 395, grade 65-45-15, is available upon special request. Clapper: luminum bronze UNS-C95500 Latch: luminum bronze UNS-C95500 Shaft: Stainless 17-4 Clapper Seal: Peroxide cured EPDM, STM D2000 Bushings/Seat O-rings: Nitrile Springs: Stainless Steel (300 Series) Diaphragm: Peroxide cured EPDM with fabric reinforcement Bill of Materials 1 Valve Body 12 Cover Plate 2 Clapper 13 Cover Plate Gasket 3 Clapper Seal 14 Cover Plate Bolts* 4 Seal Ring 15 Latch 5 Seal Washer 16 Latch Spring 6 Seal Retaining Ring 17 Latch Spring Bushing and O-ring (Qty. 2) 7 Seal ssembly Bolt 18 Diaphragm 8 Bolt Seal 19 Diaphragm Cover 9 Clapper Spring 20 Diaphragm Cover Cap Screws (Qty. 8) 10 Clapper Shaft 21 Latch Shaft 11 Clapper Shaft Bushing and O-ring (Qty. 2) 20 19 17 18 11 15 1 21 17 16 2 10 3 11 12 13 9 5 4 14 Exaggerated for clarity 7 8 6 * NOTE: The 1½-inch/48.3-mm and 2-inch/60.3-mm valve sizes contain washers under the heads of the cover plate bolts. _5

TRIM PCKGE DETILS Trim Packages: NOTE: See page 11 for details of trim and page 12 for details of European trim. 1 Galvanized components 2 Series 776 Low-Pressure ctuator The Series 776 Low-Pressure ctuator is pneumatically actuated and requires only 13 psi/90 kpa minimum air pressure, regardless of the system supply pressure. This actuator allows the system to operate with a low air or gas pressure of 7 psi/48 kpa. Request submittal 30.65. 3 ll Required Pipe and Fittings 4 ll Standard Trim ccessories 5 ll Required Gauges Optional Trim Package: 1 Black Trim for Foam Systems If the valve is intended for use in a foam system, black trim must be ordered, per NFP requirements. Specify this requirement on the order. Optional ccessories: Series 746-LP Dry ccelerator The Series 746-LP Dry ccelerator is required when the Series 768 is installed in large systems to improve response time. Request submittal 30.64. Series 760 Water Motor larm The Series 760 Water Motor larm is a mechanical device that sounds when a sustained flow of water occurs (such as with an open sprinkler). Request submittal 30.32. Series 75B Supplemental larm Device The Series 75B Supplemental larm Device is designed to provide a continuous alarm for systems equipped with a mechanical device. Request submittal 30.33. Series 75D Water Column Kit The Series 75D Water Column Kit is designed to minimize residual water in the riser from collecting above the clapper. Request submittal 30.34. larm Pressure Switch larm Pressure Switches are designed to activate electrical alarms and control panels when a sustained flow of water occurs (such as with an open sprinkler). ir Supervisory Pressure Switch ir Pressure Supervisory Switches are used to monitor low system air pressure and are factory pre-set. ir Supply System The air supply system contains all components for establishing and maintaining air in the system. The compressor, low-pressure alarms, ball valves, and required trim are included in the air supply system. ir Compressor (See page 8 for more on the Victaulic Series 7C7 Compressor Package) ir Maintenance Trim ssembly larm Panels Drain Connection Kit _6

IR SUPPLY REQUIREMENTS The required air pressure for Series 768 FireLock NXT s is 13 psi/90 kpa minimum, regardless of the system supply water pressure. ir pressures should be kept below 18 psi/124 kpa, unless a Series 746-LP Dry ccelerator is installed. Systems with air pressures higher than 18 psi/124 kpa may require the addition of a Series 746-LP Dry ccelerator. If multiple Series 768 FireLock NXT s are installed with a common air supply, isolate the systems with a spring-loaded, soft-seated ball check valve to ensure air integrity for each system. Good practice is to include a ball valve for isolation and service of each individual system. The engineer/system designer is responsible for sizing the compressor so that the entire system is charged to the required air pressure within 30 minutes. DO NOT oversize the compressor to provide more airflow. n oversized compressor will slow down or possibly prevent valve operation. If the compressor fills the system too fast, it may be necessary to restrict the air supply. Restricting the air supply will ensure that air being exhausted from an open sprinkler or manual release valve is not replaced by the air supply system as fast as it is being exhausted. COMPRESSOR SIZING 12 COMPRESSOR REQUIREMENTS 20 psi/138 kpa 13 psi/90 kpa 10 REQUIRED FLOW RTE (CFM) 8 6 4 2 0 50 300 550 800 1050 SYSTEM CPCITY (in gallons) 1300 1550 1800 _7

BSE OR RISER-MOUNTED COMPRESSORS For base or riser-mounted compressors, the recommended air pressure of 13 psi/90 kpa is the on or low pressure setting for the compressor. The off or high pressure setting should be 18 psi/124 kpa. Victaulic offers the Series 7C7 Compressor package for FireLock NXT devices which is riser-mounted and pre-set for the FireLock NXT pressure requirements as stated above. For information on the Series 7C7 package, consult publication 30.22. The Series 7C7 Compressor package is only available in North merica. When a base or riser-mounted air compressor supplies air to a Series 768 FireLock NXT, it is not necessary to install the Victaulic Series 757 Regulated ir Maintenance Trim ssembly (MT). In this case, the airline of the compressor connects to the trim at the fitting where the Series 757 Regulated MT is normally installed (refer to the applicable trim drawing). If the compressor is not equipped with a pressure switch, the Series 757P ir Maintenance Trim ssembly with Pressure Switch should be installed. For information on the Series 757 Regulated ir Maintenance Trim ssembly, see publication 30.35. For information on the Series 757P ir Maintenance Trim ssembly, see publication 30.36. SHOP IR OR TNK-MOUNTED IR COMPRESSORS In the event a compressor becomes inoperative, a properly sized tank-mounted air compressor provides the the greatest protection for systems. When shop air or a tank-mounted air compressor is used, the Series 757 Regulated MT must be installed. The Series 757 Regulated MT provides proper air regulation from the air reservoir to the sprinkler system. For tank-mounted air compressors, the recommended air pressure of 13 psi/90 kpa should be used as the set point for the air regulator. The on pressure of the compressor should be at least 5 psi/ 34 kpa above the set point of the air regulator. _8

SERIES 757 REGULTED IR MINTENNCE TRIM SSEMBLY NOTICE Victaulic recommends a maximum of two Series 768 FireLock NXT s per Series 757 Regulated MT Bill of Materials 1 1 8"/3.2 mm Restrictor 2 Slow Fill Ball Valve (Normally Open) 3 ir Regulator 4 Strainer (100 Mesh) 5 Spring-Loaded, Soft-Seated Ball Check Valve 6 Fast Fill Ball Valve (Normally Closed) 1 2 6 3 5 4 Exaggerated for clarity SERIES 757P IR MINTENNCE TRIM SSEMBLY WITH PRESSURE SWITCH NOTICE Victaulic recommends a maximum of two Series 768 FireLock NXT s per Series 757P MT with Pressure Switch 6 Bill of Materials Item Qty. Description 1 1 Restrictor (½-inch NPT) 2 1 Strainer (½-inch NPT) 3 1 Swing Check (½-inch NPT) 4 1 Slow-Fill Ball Valve (Normally Open) 5 1 Spring-Loaded, Soft-Seated Check Valve 6 1 Pressure Switch 7 2 Compression Fitting, Straight (¼-inch NPT x ¼-inch Tube) 8 1 Copper Tubing (¼-inch OD) 9 11 Close Nipple (½-inch NPT x 1.13) 10 1 Nipple (½-inch NPT x 4.00) 11 1 90 Female Elbow (½-inch NPT) 12 4 Female Tee (½-inch NPT) 13 3 Union (½-inch NPT) 14 2 Reducing Bushing (½-inch NPT x ¼-inch NPT) 15 1 Fast-Fill Ball Valve (Normally Closed) 16 1 Pressure Switch Isolation Ball Valve (Normally Open - Lockable) 2 8 7 13 5 FROM COMPRESSOR 3 1 10 14 16 9 12 15 4 11 Exaggerated for clarity TO SYSTEM _9

COMPRESSOR REQUIREMENTS Compressor Requirements and Settings for Series 768 FireLock NXT s Installed with Series 746-LP Dry ccelerators Set the air regulator of the Series 757 Regulated MT to 13 psi/90 kpa. THE SERIES 757P IR MINTENNCE TRIM SSEMBLY WITH PRESSURE SWITCH MUST NOT BE USED ON FIRELOCK NXT DRY VLVE INSTLLED WITH SERIES 746-LP DRY CCELERTOR. When a Series 768 FireLock NXT is installed with a Series 746-LP Dry ccelerator, the Series 757 Regulated MT must be used. NOTE: The use of an air regulator with a base or risermounted compressor could cause short cycling, resulting in premature wear of the compressor. In the event a compressor becomes inoperative, a properly sized tank-mounted air compressor provides the greatest protection for systems installed with a Series 746-LP Dry ccelerator. In this situation, air can be supplied continuously to the sprinkler system for an extended time period. NOTE: The Series 757 Regulated MT must be used with a tank-mounted air compressor or shop air system that continually supplies air to a Series 768 FireLock NXT installed with a Series 746-LP Dry ccelerator. The air regulator of the Series 757 Regulated MT is a relief-type design. ny pressure in the system that is above the set point of the air regulator will be released. Therefore, charging the air regulator above the set point could cause premature operation of a valve installed with a Series 746-LP Dry ccelerator. NOTE: The series 746-LP should not be used above 30 psi. If higher pressures are required, the series 746 should be used. Settings for ir Supervisory Pressure Switches and larm Pressure Switches ir supervisory pressure switches are required for dry systems and must be set according to the following instructions. NOTE: Switches for Vic-Quick Risers are pre-set at the factory. Wire the air supervisory pressure switches to activate a low-pressure alarm signal. NOTE: In addition, the local authority having jurisdiction may require a high-pressure alarm. Contact the local authority having jurisdiction for this requirement. Set the air supervisory pressure switches to activate at 2 4 psi/14 28 kpa below the minimum air pressure required, but not lower than 10 psi/69 kpa. Wire the alarm pressure switch to activate a water flow alarm. Set the alarm pressure switch to activate on a pressure rise of 4 8 psi/28 55 kpa. Remote System Test Valve Requirements The remote system test valve (inspector s test connection) should contain a UL Listed and/or FM pproved valve (normally closed), which can be opened to simulate the operation of a sprinkler. The remote system test valve (inspector s test connection) should be located at the most hydraulically demanding location in the release system. NOTE: Multiple restrictions on the remote system test valve (inspector s test connection) may slow the air decay rate and cause the system to respond slower than required. The remote system test valve (inspector s test connection) should terminate with an orifice equal to the smallest orifice in the releasing system. The remote system test valve (inspector s test connection) is used to ensure that water reaches the most remote part of the system within 60 seconds. _10

EXPLODED VIEW DRWING TRIM COMPONENTS ( TRIM) Series 768 FireLock NXT (Optional ccessories lso Shown) Bill of Materials 1 Series 768 FireLock NXT 2 FireLock Rigid Coupling (Optional/ Sold Separately Comes Standard when VQR ssembly is Ordered) 3 Water Supply Main Control Valve (Optional/Sold Separately Comes Standard when VQR ssembly is Ordered) 4 Drain Swing Check Valve 5 Drip Cup with Cap 6 larm Pressure Switch (Optional/Sold Separately Comes Standard when VQR ssembly is Ordered) 7 Series 729 Drip Check Valve 8 Diaphragm-Charge-Line Ball Valve (Normally Open) 9 3-in-1 Strainer/Check/Restrictor ssembly 10 Series 760 Water Motor larm (Optional/Sold Separately) 11 12 larm Test Ball Valve Diaphragm-Charge-Line Pressure 18 Gauge (0-300 psi/0-2068 kpa/0-20.7 Bar) 13 Series 749 uto Drain 22 14 Series 746-LP Dry ccelerator ssembly (Optional/Sold Separately) 15 Series 776 Low-Pressure ctuator 16 ir Manifold 17 ir Supervisory Pressure Switch (Optional/Sold Separately Comes Standard when VQR ssembly is Ordered) 18 System Pressure Gauge (0-80 psi/0-552 kpa/0-5.5 Bar with Retard) 19 Water Supply Main Drain Valve - Flow Test 20 Water Supply Pressure Gauge (0-300 psi/0-2068 kpa/0-20.7 Bar) 21 Drain Connection Kit (Optional/Sold Separately Comes Standard when VQR ssembly is Ordered) 22 Gauge Valve 23 System Main Drain Valve 24 Series 748 Ball Check Valve 17 23 20 22 19 24 Note 1 From System ir Feed 16 21 11 4 14a 14b 5 14 Location 1 To Drip Cup Location To System 15 13 To Drip Cup Location 22 12 7 9 10 2 To Drip Cup Location 8 6 3 Exaggerated for clarity From Water Supply Optional devices include the Series 75D Water Column Device Kit and the Series 75B Supplemental larm Kit. NOTE 1: Connection point for the Series 75D Water Column Device Kit. For installation of the Series 75B Supplemental larm Device, refer to the instructions supplied with the product. _11

EXPLODED VIEW DRWING TRIM COMPONENTS (EUROPEN TRIM ) Series 768 FireLock NXT (Optional ccessories lso Shown) VNIIPO Bill of Materials 1 Series 768 FireLock NXT 2 FireLock Rigid Coupling (Optional/Sold Separately Comes Standard when VQR ssembly is Ordered) 3 Water Supply Main Control Valve (Optional/ Sold Separately Comes Standard when VQR ssembly is Ordered) 4 Drain Swing Check Valve 5 Drip Cup with Cap 6 larm Pressure Switch (Optional/Sold Separately Comes Standard when VQR 17 ssembly is Ordered) 7 Series 729 Drip Check Valve 8 Diaphragm-Charge-Line Ball Valve (Normally Open) 9 3-in-1 Strainer/Check/Restrictor ssembly 18 23 10 Series 760 Water Motor larm (Optional/Sold Separately) 11 larm Test Ball Valve 22 12 Diaphragm-Charge-Line Pressure Gauge (0 300 psi/0 2068 kpa/0 20.7 Bar) 13 Series 749 uto Drain 14 Series 746-LP Dry ccelerator ssembly (Optional/Sold Separately) 15 Series 776 Low-Pressure ctuator 20 16 ir Manifold 17 ir Supervisory Pressure Switch (Optional/Sold Separately Comes Standard when VQR 22 ssembly is Ordered) 18 System Pressure Gauge (0 80 psi/0 552 kpa/0 5.5 Bar with Retard) 19 Water Supply Main Drain Valve Flow Test 20 Water Supply Pressure Gauge (0 300 psi/0 2068 kpa/0 20.7 Bar) 21 Drain Connection Kit (Optional/Sold Separately Comes Standard when VQR ssembly is Ordered) 22 Gauge Valve 23 System Main Drain Valve 24 Series 748 Ball Check Valve 25 Water Motor larm Shutoff Valve (Normally Open)* 19 24 Note 1 From System ir Feed 16 21 11 2 3 14a 14b 5 14 Location 4 1 To Drip Cup Location To System 13 To Drip Cup Location 22 15 12 7 To Drip Cup Location 8 9 6 25 10 *Item 25, water motor alarm shutoff valve, can be closed to prevent water from flowing into the Series 760 Water Motor alarm during conditions that are not favorable for the alarm to sound (i.e. during a trip test). From Water Supply _12

_13

_14

_15

WRNING WRNING This product must be installed by an experienced, trained installer, in accordance with the instructions provided with each valve. These instructions contain important information. Failure to follow these instructions may result in serious personal injury, property damage, or valve leakage. If you need additional copies of this product literature or the valve installation instructions, or if you have any questions about the safe installation and use of this device, contact Victaulic Company, P.O. Box 31, Easton, P 18044-0031 US, Telephone: 001-610-559-3300. WRRNTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. ll products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. WCS-7BCHWM For complete contact information, visit 4219 REV F UPDTED 3/2008