INSTRUCTION MANUAL EBA-75 CLOSED-CIRCUIT ESCAPE RESPIRATOR (CCER) CAPACITY 3

Similar documents
INSTRUCTION MANUAL FOR EBA MINUTE SELF-CONTAINED SELF RESCUER (SCSR) Manual Number: NH13747 Revision: A, ECN 2384 September 7, 2001

OCENCO M-20.3 Capacity 1 - Closed Circuit Escape Respirator (CCER) Emergency Escape Breathing Device (EEBD)

Ocenco Incorporated. M-20 Self Contained Self Rescuer Instruction Manual

OCENCO M-20.2 Self-Contained Self-Rescuer Emergency Escape Breathing Device

Care and Maintenance of the Ocenco EBA 6.5 Self-Contained Self-Rescuer

Instructor s Manual for M-20.2 EEBD & M-20.2T Training Model

APPLICATION & LIMITATIONS:

6A.004 SCBA MAINTENANCE. Policy Number. Page 1 of 5 SCOPE

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Organic Vapor/P95, Disposable

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Disposable

MMR Air Mask With. with Quick-Connect Hose

MSA AUER SSR 30/100 MSA AUER SSR 30/100 B

MSA AUER SSR 90 [K60]

5.0 INSPECTING, FILLING AND LABELING SMALL CYLINDERS

BCF WORK INSTRUCTION Respirator Inspection/Cleaning/Maintenance/Repair and Storage

Care and Maintenance of the Draeger OXY K Plus Self-Contained Self-Rescuer

STATEMENTS OF FACT BENCH BG-4 CONTEST. 1. A positive pressure leak could be caused by a leakage in or at device components.

Checklist for care of Respirators

PremAire INSTRUCTIONS FOR DUAL-SUPPLY MODE OF OPERATION

Fire Escape Hood OPERATION AND INSTRUCTIONS

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

Product Information News

Operating Manual MSA SSR 30/100 / MSA SSR 30/100 B EN K/20/S. Order No /01. MSAsafety.com

Phalanx Alpha Phalanx Beta and Ultra Elite

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

Operation Manual Guillotine Cutter RC-5

60 Minutes Self Contained Self Rescuer. Donning Procedures for Person-Wearable Self Contained Self Rescuer

ExtendAire TM II. Intermediate Pressure Accessory Kit USER INSTRUCTIONS

UltraFilter. respirator. with Ultravue or Ultra Elite Facepiece. instructions for use and care

BioPak 240 Revolution

STATEMENTS OF FACT BENCH BG-4 CONTEST. 1. A positive pressure leak could be caused by a leakage in or at device components.

Rev. B. Operating Instructions

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

Donning Personal Protective Equipment

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

WW-730. Pressure Sustaining/Relief Control Valve

RB70 Automatic Diluent Valve Maintenance Manual. Version 1.1 November 2006 Written by Tino de Rijk. Page 1 of 23

Respiratory Protection. Program

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

Rapid Survival System

BioPak 240 Revolution

TECHNICAL DATASHEET ELSA MUSTER ESCAPE BREATHING APPARATUS DESCRIPTION APPLICATIONS

Entry to these spaces must be rigorously controlled to prevent serious injury or death.

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

City of Minot Specifications SCBA

XpressFill XF2500 Counter Pressure Filler. Operating Instructions

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 11 Specifications and Overview Revised

Owner s Manual for Assembly, Operating & Maintenance of

XpressFill XF4500 Counter Pressure Filler. Operating Instructions

A. Evaluation of the written program

ALERT SERVICE LETTER

Bermad Pressure Reducing. Model: 42T

E3628 THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING. Leader s Guide ERI Safety Videos EMPLOYEE TRAINING

INSTALLATION, OPERATION AND SERVICE MANUAL ABS AIR BAG LIFT

30T A/Manual Hydraulic Shop Press

COLUMBUS STATE COMMUNITY COLLEGE EMPLOYEE SAFETY MANUAL

Texas Department of Insurance. Respiratory Protection. Provided by. Workers Health & Safety HS01-027B (1-06)

Model: 43T. Bermad Pressure Relief Valve

Focus Area Campaign for November 2014 SCBA

Course Firefighter I. Unit II Safety and Orientation

Features. Description

DBML-60/80 Squeeze Tool

CS150 CAP STAPLER OWNER S MANUAL

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

Combination Breathing Apparatus

Installation Instructions and valve Maintenance Rev. 0 of 21/09/15

98695A01 - THE CONCEPT OF THE DIVATOR FAMILY

Installation and Service Manual

ALLEGRO INDUSTRIES SERIES 9910 (LP) CONTINUOUS FLOW, SUPPLIED AIR HOOD RESPIRATORS P/N 9910 P/N 9910R P/N 9910D P/N 9910DS P/N 9912D

Tire Inflation Cage Kit For servicing only single piece automotive, and most light truck tire/wheel assemblies

Speed control assembly model A-1

SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL

Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150

Part # Balanced SCUBA Regulator Assembly for M-48 SuperMask and MOD-1 Installation Guide

Training. Testor Training Manual

SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL

Combination Breathing Apparatus

NO SMOKING WHEN OXYGEN IS IN USE.

Self-Rescue Equipment and Skill Development for Mine Escape

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

Pressure Relief Valve Instruction Manual

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

1200B2 Series Service Regulators. Instruction Manual

User Information Sheet 013

TABLE OF CONTENTS PART 2 - CONFINED SPACES

Warning: NEVER ALTER TEST EQUIPMENT

Frigitronics CRYO-PLUS

PPE: RESPIRATORY PROTECTION EQUIPMENT

1805 Series Relief Valves

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

LUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010

WW-720. Pressure Reducing Control Valve

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

LEAK SEALING SYSTEMS

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

DIVATOR THE COMPLETE DIVING SYSTEM INTERSPIRO PRODUCT CATALOG

Head Cover BE-12 Series

KMB 18/28 (BANDMASK) OVERHAUL, MAINTENANCE, AND INSPECTION CHECKLIST APPENDIX A

Transcription:

INSTRUCTION MANUAL FOR THE EBA-75 CLOSED-CIRCUIT ESCAPE RESPIRATOR (CCER) CAPACITY 3 Manual Number: NH24053 Revision: A, ECN 3590 December 14, 2015 Page 1 of 13

CONTENTS PAGE INTRODUCTION... 3 GENERAL INFORMATION. 3 WARNING... 3 SYSTEM DESCRIPTION & OPERATION 3 OCENCO EBA-75 FUNCTIONAL DIAGRAM 4 INSTRUCTIONS FOR USE.. 5 INSTRUCTIONS FOR USE FOR USER AT REST... 5 INSPECTION & MAINTENANCE.. 6 INSPECTION CHECKLIST. 7 OCENCO EBA-75 PARTS DIAGRAM 8 SPECIFICATIONS. 10 DISPOSAL 11 REGISTRATION. 11 INSTRUCTION & APPROVAL LABEL.. 12 Page 2 of 13

INTRODUCTION This manual describes the specifications of the Ocenco EBA-75 and explains the proper use of the unit. This manual also identifies key components and their functions. It demonstrates the proper procedures for donning and using the Ocenco EBA-75 and the procedures to be followed in performing daily and 90-day inspections. GENERAL INFORMATION The EBA-75 has been approved by MSHA/NIOSH under 42 CFR 84 as a Capacity 3, Closed-Circuit Escape Respirator (CCER). Similarly, the EBA-75 has the ability to provide a person with up to 6.5 hours of oxygen if he remains at rest and follows the procedures necessary for maximum conservation of oxygen as explained in the section titled Instructions for Use for User at Rest. Because the EBA-75 is a life-saving escape device, each person using the unit should: 1) Be thoroughly familiar with and trained in the procedures for donning, wearing, and inspecting the unit as explained in the Instructions for Use section on page 5 and the Inspection and Maintenance section on page 6. 2) Avoid physical abuse to the unit. 3) Follow all NIOSH and MSHA recommendations regarding the use of self-contained self-rescuers. WARNING The EBA-75 was designed and approved solely as an exit or escape device. The unit is not intended or approved as an entry and rescue breathing apparatus. Furthermore, the unit was not designed or approved for fire fighting or underwater breathing. SYSTEM DESCRIPTION & OPERATION The EBA-75 is a closed circuit self-contained self-rescue device designed to be wearable with an additional protected harness for shoulder support. The unit is housed in a rugged transparent polycarbonate case to permit rapid, easy visual inspection of all components and to give each user greater confidence and familiarity in using the system. The EBA-75 system consists of two simple sub-systems: 1) The compressed oxygen supply circuit, and 2) The closed breathing circuit. The following descriptions refer to the included EBA-75 functional diagram shown on the next page. Page 3 of 13

1) Compressed Oxygen Supply Circuit Medical grade oxygen is stored in a DOT approved refillable oxygen bottle that has been pressurized to 2250 psi and holds 110 liters of oxygen. The oxygen flow is controlled through a series of valves and is activated by turning the ON/OFF valve counterclockwise. The pressure gauge is visible at all times. The oxygen moves through the ON/OFF valve into a pressure reducing regulator that reduces the oxygen pressure to 100 psi. The oxygen then passes from the pressure-reducing regulator through a hose and into the demand regulator. The demand regulator provides a constant flow of 1.6 liters per minute with a minimum of 40 liters per minute upon demand. The oxygen then moves through an additional hose from the demand regulator to the breathing bag. 2) Closed Breathing Circuit The breathing bag is the reservoir of breathable gas and is constructed of durable urethane coated nylon. Oxygen is inhaled from the breathing bag through an inhalation tube and mouthpiece. The expired breath moves through the mouthpiece and to the CO2 scrubber through an exhalation tube. The CO2 scrubber is constructed of steel with a lithium hydroxide bed to remove CO2 from the expired breath. The scrubbed breath then re-enters the breathing bag through a tube connected to the bottom of the scrubber and is mixed with fresh oxygen. A relief valve is located in the center of the breathing bag to vent any excess pressure and to maintain the exhalation pressure of the breathing circuit within safe limits. EBA-75 FUNCTIONAL DIAGRAM ON-OFF VALVE * ACTIVATES SYSTEM * PERMITS OXYGEN CONSERVATION PRESSURE GAUGE * READS 2000-2500 PSI WHEN CHARGED * VISIBLE DURING USE ON DEMAND REGULATOR * PROVIDES CONSTANT FLOW OF 1.6 LITERS PER MINUTE * PROVIDES MINIMUM DEMAND FLOW OF 40 LITERS PER MINUTE MOUTHPIECE & VALVE ASSEMBLY * CONTROLS INHALATION AND EXHALATION * REDUCES DEAD SPACE FRANGIBLE DISC * SAFETY RELIEF * BOTTLE PRESSURE RELIEVES AT 4800 PSI PRESSURE REGULATOR * REDUCES PRESSURE TO 100 PSI RELIEF VALVE * RELIEVES EXCESS PRESSURE OF THE BREATHING BAG SCRUBBER * REMOVES CO 2 OXYGEN BOTTLE * ALUMINUM CYLINDER * 110 LITERS * MEDICAL GRADE OXYGEN * D.O.T. APPROVED * REFILLABLE BY OCENCO * 5000 P.S.I. TEST BREATHING BAG * VOLUME - 5 LITERS Page 4 of 13

INSTRUCTIONS FOR USE (1) Pull latch release rod. (2) Lift and pull each latch ring to release bands. (3) Remove cover from base. Grab the two handle straps and pull case apart, discard cover and rubber seal. (4) Open oxygen valve fully counterclockwise, in direction of arrow. (5) Place neck strap over head. (6) Pull mouthpiece toward face. The mouthpiece plug will automatically be removed from the mouthpiece. Insert mouthpiece and breathe through mouth only. Use head strap for additional support of mouthpiece, if required. (7) Apply noseclips to nose. Do not attempt to inhale or exhale through your nose. (8) Purge bag: Exhale into mouthpiece, hold breath and deflate bag by pressing on bag, then inhale through the mouthpiece, and breathe normally. Gas will vent through the relief valve. Do not remove mouthpiece or nose clip during purge. (9) Adjust neck strap for comfort. (10) Wrap waist harness around waist, clip and adjust for fit by pulling on strap end. (11) To fit the goggles, pull the goggles over the head. After donning the goggles, prescription eyeglasses can be donned by guiding the eyeglass temples through the channels provided. (12) ESCAPE Proper handling, maintenance, and other information as supplied in this manual are essential to the effective use of the EBA-75. The user should be familiar with Instructions for Use 1-12 before attempting to use the EBA-75. INSTRUCTIONS FOR USE FOR USER AT REST THE FIRST OBJECTIVE IS TO ESCAPE. In the event escape from an oxygen deficient atmosphere cannot readily be achieved, the EBA-75 can operate for up to 6.5 hours when the user is at rest. Listed below are the steps required to extend the oxygen supply of the EBA-75 past one hour if the unit is to be used by a man at rest. Rest is defined as a man sitting with no activity. (1) Purge bag: Exhale into mouthpiece, hold breath and deflate bag by pressing on bag, then inhale through the mouthpiece, and breathe normally. (2) When bag fills, close oxygen valve, clockwise. (3) When bag becomes low, open oxygen valve, counterclockwise. (4) Repeat steps 2 and 3 until no longer at rest. Note: Performance of the EBA-75 under the User At Rest procedure, not a requirement of 42 CFR Part 84, Subpart O, has not been evaluated by NIOSH/MSHA. Page 5 of 13

INSPECTION AND MAINTENANCE Inspection guidelines are based on the deployment of the device. If the EBA-75 is carried daily it is to be inspected daily. If the EBA-75 is stored according to an approved MSHA storage plan, it is to be inspected every 90 days. If the EBA-75 is stored in a protective storage container on a vehicle the inspections outlined below are not necessary except for the 90-day inspection. The EBA-75 is housed in a rugged transparent polycarbonate case. The case enables the user to inspect the unit easily and in a minimum amount of time. The daily inspection as well as the 90-day inspection should consist of the following: (1) Check the oxygen pressure gauge. The pressure gauge reading is normally 2250 psi at 70 F. Remove from service if below 2000 psi or above 2500 psi at 70 F. If the case is damaged and the gauge cannot be read, the unit must be removed from service. (2) Make sure that all the latch seals are not broken. Two seals are provided, one for each band. If both seals are broken, remove the unit from service. (3) Inspect the apparatus for indications of abuse. If the view through the case is obstructed such that a proper examination cannot be performed (e.g. scuff marks, stickers, and paint) the unit must be removed from service. Indications of abuse are listed below. If any of these signs are present the unit must be removed from service. a. Case cracked, burned, or deformed b. "U" seal bulged out, rolled or torn c. Loose parts Bottle strap (stainless steel) Scrubber canister not in mounts Screws or inserts d. Bottle pad (red rubber) cut or displaced e. Pressure gauge bent or indicator needle broken f. Scrubber dented g. Dirt, debris, or moisture inside case h. Handle loops broken (the plastic loops that hold the handle straps) i. One or both of the two handle straps (black nylon straps) missing or broken (4) Make sure that the yellow mouthpiece plug is in the mouthpiece. Remove the unit from service if the plug is removed. If the EBA-75 fails any of the above inspections, it should be removed from service and returned to Ocenco, Incorporated. A summary of the inspection points is given on the next page. Page 6 of 13

INSPECTION CHECKLIST Remove the unit from service if any of the following conditions are evident: 1. View through clear case obstructed by scuffmarks, stickers, etc. 2. Gauge pressure below 2000 psi or above 2500 psi at 70 F 3. No factory installed latch seals attached 4. "U" seal bulged out, rolled or torn 5. Case cracked, burned, or deformed 6. Mouthpiece plug (yellow rubber) not in place 7. Loose Parts Bottle strap (stainless steel) Scrubber canister not in mounts Screws or inserts 8. Bottle pad (red rubber) cut or displaced 9. Pressure gauge bent or indicator needle broken 10. Scrubber canister dented 11. Dirt, debris, or moisture in case 12. Handle loops broken (the plastic loops that hold the handle straps) 13. One or both of the two handle straps (black nylon straps) missing or broken. 14. Inspect the factory service date label on the base and remove unit if past the mandatory factory service date. IN-SERVICE TESTING & TRAINING In-service EBA-75s selected for training or testing purposes must meet all of the inspection criteria listed above, and shall have been maintained in accordance with the stated conditions of this manual. Devices that fail visual inspection, are deployed outside the conditions of use, or are past their service life date, must be removed from service and shall not be used for training or testing purposes. Further, the EBA-75 donning instructions must be followed without omissions or additions to the stated procedure. Failure to follow the proper donning instructions may result in reduced respiratory protection. Page 7 of 13

EBA-75 PARTS DIAGRAM 1 2 3 4 13 INHALATION TO MOUTHPIECE 5 6 INHALATION FROM UPPER END OF BREATHING BAG EXHALATION TO UPPER END OF SCRUBBER 8 9 ON FROM DEMAND REGULATOR 12 7 10 11 FROM LOWER END OF SCRUBBER TO LOWER END OF BREATHING BAG 1. NECK HARNESS 2. NOSE CLIP 3. GOGGLES 4. MOUTHPIECE 5. PRESSURE GAUGE 6. ON-OFF VALVE 7. OXYGEN BOTTLE 8. DEMAND REGULATOR 9. MOUTHPIECE PLUG 10. SCRUBBER 11. WAIST HARNESS 12. RELIEF VALVE 13. BREATHING BAG Page 8 of 13

REQUIRED HANDLE STRAP (ATTACHED TO BASE) 15 19 14 MFG: XXXX CARRY: XXXX STORE: XXXX 17 16 OPTIONAL SHOULDER STRAP ATTACHED TO COVER REQUIRED HANDLE STRAP (ATTACHED TO COVER) 18 14. FACTORY SERVICE LABEL 15. LATCH PIN 16. LATCH RELEASE RINGS 17. LATCH SEALS 18. BAND 19. HANDLE STRAP Page 9 of 13

SPECIFICATIONS The EBA-75 has been designed to provide respiratory protection during escape from oxygen deficient or hazardous atmospheres. This device enables the user to breathe independently of the ambient atmosphere for a minimum period of 60 minutes. Performance Data Capacity 110 liters of oxygen Note: proper use of the device for "User at Rest" - 6.5 hours maximum Dimensions 21.8 x 30.2 x 11.7 cm (8.6 x 11.9 x 4.6 in) Weight 8 lbs. (carry in operation) Operating Environment Minimum operating temperature 32 F (0 C) Nominal cylinder pressure 2000 to 2500 psi. Service life The EBA-75 is designed for a service life of fifteen years if properly inspected and if the conditions of use are observed. A Mandatory Factory Service action shall occur ten years from the date of manufacture if the units have been stored and five years from the date of manufacture if the units have been carried. The end of service life for the EBA-75 is fifteen years from the date of manufacture regardless of the deployment method. The Conditions of Use for the EBA-75 are: A. Daily and 90-Day Inspections as defined in this manual. B. Caring for the EBA-75 as defined in this manual. C. Acceptable Storage of the EBA-75: the EBA-75 must be stored in an Ocenco approved carry case and securely fastened to a wall or other substantial structure. Devices stored on vehicles must be secured against movement in a fully enclosed metal container. D. Acceptable Carry of the EBA-75: the EBA-75 must be carried in an Ocenco approved carry case. Scrubber life is limited to one escape event or one oxygen charge. NOTE: If escape is necessary don the device regardless of temperature. DISPOSAL Safe disposal is necessary after the EBA-75 has been used, fails inspection, or has exceeded the fifteen year service life. Ocenco EBA-75s must be disposed of in accordance with hazardous material disposal regulations. Page 10 of 13

REGISTRATION The National Institute for Occupational Safety and Health (NIOSH) requests, but does not require, that purchasers of this respirator register each unit with NIOSH. Registration will enable NIOSH, which approved this model of respirator, to attempt to notify you if a problem is discovered that might affect the safety or performance of this respirator. Registration will also assist NIOSH in locating deployed units to periodically evaluate whether this respirator model is remaining effective under field conditions of storage and use. Page 11 of 13

Ocenco Incorporated 10225 82 nd Ave. Pleasant Prairie, WI, 53158 USA (262) 947-9000 Model: EBA-75 CAP 3-M-110L CLOSED-CIRCUIT ESCAPE RESPIRATOR SELF-CONTAINED BREATHING APPARATUS THIS RESPIRATOR IS APPROVED ONLY IN THE FOLLOWING CONFIGURATIONS: Model Name EBA-75 TC - Protection 1 Part Number 900300 Cautions and Limitations 2 13G-0005 SC/ESC/CAP 3-M-110L X JMNO 1. PROTECTION SC Self-contained ESC Escape CAP Capacity 2. CAUTIONS AND LIMITATIONS J - Failure to properly use and maintain this product could result in injury or death. M - All approved respirators shall be selected, fitted, used and maintained in accordance with MSHA, OSHA, and other applicable regulations. N - Never substitute, modify, add, or omit parts. Use only exact replacement parts in the configuration as specified by the manufacturer. O - Refer to the User s Instructions and/or maintenance manuals for information on the use and maintenance of this respirator. Page 12 of 13

LakeView Corporate Park 10225 82nd Avenue Pleasant Prairie, Wisconsin 53158-5801 United States of America Telephone: (262) 947-9000 Telefacsimilie: (262) 947-9020 www.ocenco.com Page 13 of 13