BHEL/Trichy-14 CCDP SYSTEM DESCRIPTION FOR DOME VALVE:

Similar documents
T E N D E R Tender # T SCOTT SCBA AIR PACKS AND ACCESSORIES SAINT JOHN FIRE DEPARTMENT

NIT LIMITED NO. NC-105-P-SCS-NOCB CYLINDERS & REGULATORS

DEPARTMENT OF CHEMICAL ENGINEERING INDIAN INSTITUTE OF TECHNOLOGY MADRAS CHENNAI , INDIA

For Department of CSSD

NIT LIMITED NO. NC-185-SCS-P-NOCB ARGON & NITROGEN CYLINDER WITH REGULATOR

NIT LIMITED NO. RD-NC-40-SPS-PH

Knife Gate Valves Pricelist 2017

THE MAHARASHTRA STATE CO-OPERATIVE BANK LTD

Indian Institute of Technology Kanpur Samtel Centre for Display Technologies

OIL INDIA LIMITED (A Government of India Enterprises) 4, India Exchange Place Kolkata -1 INVITATION TO E-BID UNDER COMPOSITE BID SYSTEM

ASSAM UNIVERSITY, SILCHAR. NOTICE INVITING TENDER No._AU/SPE/191/18 Date: 14/12/2018

BHARAT HEAVY ELECTRICALS LIMITED CORPORATE RESEARCH & DEVELOPMENT DIVISION VIKASNAGAR, HYDERABAD , INDIA ENQUIRY

To, All concerned. Subject: - Notice Inviting Tender (NIT) for Printing of all books and booklets of NMPB regd. Sir,

Invitation of quotation For Dilator & Metal Catheter Set At All India Institute of Medical Sciences, Jodhpur

TENDER SPECIFICATION No: 12/ of SUPERINTENDING ENGINEER (CTI & ENQUIRIES), Dt

INVITATION FOR QUOTATION. TEQIP-III/2019/mmug/Shopping/51

AIRMASTER SERIES RF AUTOMATIC DEWATERING VALVES. For the purging of water from compressed air systems WHERE DO YOU NEED AUTOMATIC DEWATERING VALVES

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

CENTRE OF BIOMEDICAL RESEARCH

TENDER FOR SUPPLY OF MEDICAL GASES

BOXING FEDERATION OF INDIA

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Choosing the right miniature instrument and control valve is a snap

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

Town of Wells Vehicle Bid Package

4/2 way Pneumatic Solenoid Valve

OFFICINE OROBICHE S.p.A. 1/9

F.No DM(RH)U-16/19/2/ Med. Gases/2003 Dt

GUJARAT STATE ELECTRICITY CORPORATION LIMITED

Medical Superintendent

M A B MAB INFLATABLE GASKET SLIDE VALVES SERIES TSV FOR POWDERED AND GRANULAR SOLID MATERIALS

Specifications of Cryogenic vacuum jacketed valves

HUMIDITY CONTROLLED PROBE STATION (Total Budget: 0.55 crores INR) S.No. Item Unit Qty Make

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

INSTALLATION & MAINTENANCE INSTRUCTIONS - ORIGINAL VERSION AVK KNIFE GATE VALVES

776 Cryogenic Safety Valve

Xpress L90LS Directional Control Valve. Catalog HY /UK December, 2001

SPORTS AUTHORITY OF INDIA NETAJI SUBHAS REGIONAL CENTRE, SAROJINI NAGAR, KANPUR ROAD, LUCKNOW

Precision Rotary Airlocks and Diverter Valves

QUOTATION. Procurement of Equipments for sports

BHARAT PETROLEUM CORPORATION LIMITED A INSTALLATION, SEWREE FORT ROAD SEWREE (E), MUMBAI

CHECK-VALVES Automatically Position Themselves by the Natural Forces of the Conveying Air. A PNEUMATIC CONVEYING SYSTEM PATENT #: 5,160,222

STATUTORY PRESSURE TESTING AND PAINTING OF LPG CYLINDERS

tel: fax: web:

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Bray/ VAAS O-Ported Series Knife Gate Valve 770/780 Series Operation and Maintenance Manual

Flow control valves Series RFU - RFO 2/

Industrial Hydraulic Pumps T6EDC. We are doing our parts to keep you moving! Denison Vane Technology, fixed displacement

OPERATION MANUAL PNEUMATIC VALVES

TECHNICAL DATA. Q = C v P S

CAPITAL CONTROLS SERIES NXT3000

FEPA PNEUMATICALLY AND SOLENOID ACTUATED VALVES, ONE UNIT MOUNTED TYPE VPG

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

Pressure and Vacuum Switches for Process Applications

Tender No.513-U/16/30/Med.Gases/ESICH/TLI Date: TENDER FOR SUPPLY OF MEDICAL GASES ************ Earnest Money Deposit (EMD)

TECHNICAL DATA. Q = C v P S

Safety. Operating instructions Magnetic relief valve VAN DANGER. Contents WARNING CAUTION. Changes to edition 11.11

REQUEST FOR BIDS For Intake Tunnel Project Bid Notice

TECHNICAL DATA. Q = C v P S

- Written price quotations are valid for 30 days from the date of the quote unless otherwise noted.

TECHNICAL DATA. Q = C v P S

TURNKEY PROPOSAL FOR SNG SYSTEM RANSOME RW900E WATERBATH VAPORIZER WITH MPM50C MIXER

OP11 OVERALL SPECIFICATIONS

Installation, Operation, & Maintenance Manual

3-Way Safety Block DSV

AIR LOCK RELAY STANDARD SPECIFICATION

TECHNICAL DATA OBSOLETE

TECHNICAL SPECIFICATION FOR PNEUMATICALLY OPERATED GLOBE VALVES HANDLING WATER

Modulating liquid level regulators, servo-controlled PMFL / PMFH and SV

Product Bulletin No.: D99-RRV2015-PIB-001

ROTATING DISK VALVES INSTALLATION AND MAINTENANCE 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6

OPERATION, INSTALLATION, & MAINTENANCE MANUAL. for. Aircon Flex-air AN Airlocks

Application Note. Safety Sub-function PUS Category 1, up to PL c. Application Note PUS, Category 1, up to PL c M20 S22 R20 M1 Q20

Kinetics Fluid Systems - Process Flow Products. 18 February

CSIR-NATIONAL GEOPHYSICAL RESEARCH INSTITUTE (COUNCIL OF SCIENTIFIC & INDUSTRIAL RESEARCH) Uppal Road, Hyderabad (Telangana.

ASSE International Product (Seal) Listing Program. ASSE Performance Requirements for Air Valve and Vent Inflow Preventer

SAN ANTONIO WATER SYSTEM PURCHASING DEPARTMENT FORMAL INVITATION FOR BIDS ANNUAL CONTRACT FOR VERTICAL SHORES PARTS AND SERVICE ADDENDUM 1

Telefon (+45) Telefax (+45)

Air preparation units

Nugget 120 V14 Series

DS MB, MBF THREE PORT VALVES

Water Safety Shut-off Valve HON 790

Bushing Viton O-ring (Other material available) Anti-Static Device

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

Series C8/CR Cryogenic

Pressure and Flow Control Valves DBGM, German and European Patents

PRE BID QUERIES FOR CNG & CITY GAS DISTRIBUTION FOR HYDERABAD. Clause No. Description in tender documents Clarifications / Request for change

Nugget 120 V14 Series

Plummer Block Housings

Engineered Valves Group. Revision 2. FABRI-VALVE High Performance Knife Gate Valve.

PILOT OPERATED RELIEF VALVE SAFETY PRODUCTS THAT PROTECT EQUIPMENT, LIVES & THE ENVIRONMENT

Liquid level regulating valves Types PMFL / PMFH and SV

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

NATIONAL INSTITUTE OF ANIMAL BIOTECHNOLOGY (NIAB)

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Breather Control V1.4. Installation Manual

Mark 958 Series Sanitary Gas Back Pressure Regulators

BHAGYANAGAR GAS LIMITED (A JOINT VENTURE OF HPCL & GAIL)

NATIONAL CENTER FOR COMBUSTION RESEARCH AND DEVELOPMENT (NCCRD) INDIAN INSTITUTE OF TECHNOLOGY MADRAS CHENNAI , INDIA

/ FLT-M Quick Clean Rotary Airlock Valve Operators Manual. Kice Industries, Inc. RAV-M RAV-M

Transcription:

BHEL/Trichy-14 CCDP SYSTEM DESCRIPTION FOR DOME VALVE: The Dome Valve is a pressure tight, power operated Valve for application in Material Inlet / Vessel Discharge / Line Change over etc. The Valves should be provided with an Inflatable sealing arrangement. It should be designed to open and close by actuating a Pneumatic Cylinder by an external 5/2 Solenoid Valve. Sealing of inflatable seal is to be done by another external 3/2 Solenoid Valve. Scope of supply: Dome valve 100 NB & 200 NB with complete assembly. Dome & top plate, air limit switch, neoprene insert seal & air cylinder but with pneumatic panel consisting solenoid valve & pressure switch. Technical Specification: 1. Number of Dome valves with accessories: a. 200 NB Valve : 2 Number b. 100 NB Valve : 2 Number 2. Operation : Pneumatic 3. Type & connection : Flanged 4. Valve working pressure : Restricted to 6 Kg/cm 2 (g) 5. Available Instrument air pressure : 6 Kg/cm 2 (g) 6. Spare Parts : Should be easily replaceable 7. Pneumatic Cylinder Make : Rotex or equivalent 8. Pneumatic Limit Switch Make : Rotex or equivalent 9. 5/2 Solenoid valve for each valve : 1 No (110 VAC, 50 Hz) 10. 3/2 Solenoid valve for each valve : 1 No (110 VAC, 50 Hz) 11. Pressure switch for each valve : 1 No 12. Hardness : 150-250 BHN or more 13. Material of construction a. Body, Top Plate, Spigot, Insert Ring : CI or equivalent b. Drive and Driven Shafts : SS or equivalent c. Dome : Graded Cast Iron or equivalent d. Inflatable Seals : Silicon e. Shaft Seals : Viton or equivalent f. V Ring Seals : Neoprene or equivalent g. Top Plate to Body Gasket : Neoprene or equivalent

An ISO 9001 Company Bharat Heavy Electricals Limited R & D and Coal Research Coal Research Centre Tiruchirappalli 620014, Tamil Nadu, India COMMERCIAL TERMS AND CONDITIONS FOR SUBMISSION OF OFFER 1.0 QUOTATIONS Bidders shall submit the offer in TWO INNER ENVELOPES as indicated below which shall be sealed in one outer envelope. Envelope I This sealed envelope should contain all the copies of technical bid together with un-priced commercial bid. This envelope should be clearly marked Part I - Technical and commercial bid, indicating Enquiry No., Due Date and Address & Reference of the Bidder. Envelope II This sealed envelope should contain price details. This envelope should be clearly marked Part II - Price bid, indicating Enquiry No., Due Date and Address & Reference of the Bidder. Both the envelopes ( Part I & II) shall be put in one cover, duly sealed, superscribing as Part I and Part II of Enquiry No., due date of opening and the address and reference of the Bidder. The above offer should reach this office on or before the due date by 14.00 Hrs (IST). Late offers will not be considered. We suggest you to send the offer by SPEED POST. Tender should not be addressed to any Individual s name but only by designation to: AGM / R&D and Coal Research Purchase Department Coal Research Centre (WRI Complex) BHARAT HEAVY ELECTRICALS LIMITED TIRUCHIRAPALLI - 620 014 TAMIL NADU, INDIA Contact Phone No. 0431-257 7152 / 257 7558 Tenders should be free from CORRECTION AND ERASURES, Corrections if any, must be attested. All amounts shall be indicated both in words as well as in figures. Where there is difference between amount quoted in words and figures, amount quoted in words shall prevail. Offers should be in ENGLISH and accompanied by detailed technical literature, catalogue and details of process facility in ENGLISH.

2.0 PART I (TECHNICAL & COMMERCIAL BID) 2.1 Technical This part shall include / indicate the following: Offer should contain complete scope of supply with all technical details, specifications, delivery and other commercial terms and conditions. 2.2 Commercial This part shall include / indicate the following: 2.2.1. Port of shipment / Station of despatch 2.2.2. Terms of payment 2.2.3. Taxes & duties applicable. 2.2.4. Delivery Schedule 2.2.5. Offer validity 2.2.6. Country of origin 2.2.7. A copy of Un-Priced Part II i.e., a copy of the Price Bid without the price details to be enclosed. 3.0 PART II (PRICE- BID) This part should contain the schedule of price particulars and to be co-related to the technical details provided in Part I. 4.0 OPENING OF TENDERS The Part I - Technical & commercial bid alone would be opened on the Tender opening date. The Part II - Price bid of Technically suitable Bidders alone would be opened. The Technically suitable Bidders would be informed about the tender opening date. Clarifications if any required by BHEL for Technical evaluation would be sought from Bidders before opening of Part II - price bid. 5.0 GENERAL 5.1. Incomplete offers will not be considered. 5.2. Terms of Delivery: Bidders are required to quote their best delivery period. Foreign Bidders should submit their offer for net FOB - Nearest Sea Port / Air Port. Indian Bidders should submit their offer for Ex-Works /F.O.R basis. Delivery shall be counted from the date of Letter of Intent. 5.3. Taxes and Duties : All Taxes and Duties payable as extra to the quoted price should be specifically stated in offers along with CST & TIN No etc., failing which the purchaser will not be liable for payment of such Taxes and Duties. Note : We are not eligible to issue C Form.