Résumé: Abstract: Mots clés: Flottage; tube pré-lubrifié; broyage; chantier mobile. Keywords: Floating; pre-lubricated ducts; crushing; mobile site

Similar documents
Work Standard CABLE PULLING OPERATIONS

Installation Guideline for Placing Fiber Optic Cable into an Underground Duct

Underground Cable Installation Practices

STRATOS. High performance fiber ropes for logging applications

Protected Microducts, Overview and Current Trends

2 FUSION FITTINGS FOR USE WITH POLYETHYLENE PRESSURE PIPES DESIGN FOR DYNAMIC STRESSES

RECOMMANDATION GÉNÉRALE D UTILISATION PORTE-CLIPS PORTE-LANGUETTES 16 VOIES HYBRIDE

Typical Strength of Glued Connection. Typical Strength of Screwed Connection

General No. 25 and D-25 Handy Operating Instructions

TRAC. Document de référence 2011/03 Reference Document 2012/03

HBLT-A1 LIQUID LEVEL SENSOR

Distributeurs commande manuelle à levier

Friction occurs when surfaces slide against each other.

Siting and Installation Manual

TECHNICAL HANDBOOK nvent CADDY Speed Link Manual. SLS Locking Device

P R I M A X. The Most Advanced Shoring Devices SAFER - FASTER - DEEPER - CHEAPER THE ULTIMATE SHORING TECHNIQUES ARE NOW ON YOUR HANDS

USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH

Made of Chloraflon, 5 Years warranty Resists to chlorine chemical attacks

Acoustic Pulse Reflectometry Brings an End to Tube Inspection Sampling By Dr. Noam Amir, Chief Technology Officer, AcousticEye

Visio Solaire CAS DE POSE

INTERVAL RUNNING V2.65 FOR: Vivoactive and HR, Tactic Bravo, FR230/235/630 (V2.4: FR20XT)

ROLL FORMER CORP. ROLL FORMER CORP. Manufacturers of quality roll forming equipment leading

Requalification of Pressure Equipment

1.2 Example 1: A simple hydraulic system

TB 42. Low maintenance effort saves on time and costs. High variability for vehicle types, construction and expan- sion options

ASSEMBLY AND OPERATING MANUAL LTW MAXI TRENCH BOX

Sustainable Installation & Maintenance Methods Keith McDermott Commercial Director for Tidal Energy Mike Wilson - Managing Director Mike Wilson

ASSEMBLY AND OPERATING MANUAL LTW SHORING BOXES VB 100 & VB 120

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual

DEVELOPMENT OF A ROBUST PUSH-IN PRESSUREMETER

This document is a preview generated by EVS

FTC130 Transmitter. Operating Manual

FINALIZATION OF THE HAND DUG WELL. Version : April 2009 Published by : Foundation Connect International Autors : Henk Holtslag & John de Wolf

BRINGING A NEW DIMENSION TO PIPELINE PIGGING. By: David Aitken, Aubin Group, UK

Aquashield to Mitigate Water Ingress of Gas Pipes

Module 2, Add on Lesson Depth Sensor. Teacher. 90 minutes

Research on Small Wind Power System Based on H-type Vertical Wind Turbine Rong-Qiang GUAN a, Jing YU b

Control the air. Control your business.

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

SCOTT PLASMA 4 BIKE OWNER S MANUAL

USER S GUIDE & SAFETY MANUAL USER S GUIDE & SAFETY MANUAL Duct Rodder

REQUIREMENTS AND HAND-OVER DOCUMENTATION FOR ENERGY-OPTIMAL DEMAND-CONTROLLED VENTILATION

WHAT DETERMINES THE STRENGTH OF A SNOW ANCHOR? HOW STRONG DOES A SNOW ANCHOR SYSTEM HAVE TO BE?

Rejuvenation Instructions

ASCE D Wind Loading

ASSEMBLY AND OPERATING MANUAL LTW SHORING BOXES VB 60

The club and town of Condé sur l Escaut, judo capital on October 21 st 2017

Deborah Houssin-Agbomson, Jean-Yves Letellier, Philippe Renault, Simon Jallais

Flexfence Swaging Unit. Product Manual. Release 02/16.

PN LINE. Technical remarks PN 11 PN 13 PN 14 PN 15 PN 17 PN 18 PN 20 PN 23 PN 25 PN 26 PN 27 PN 28 PN 29 PN 37 PN 38 PN 39 PN 40 PN 43 PN 10 8_9 10_12

Guidelines for Property owners dealing with Blocked Ducting.

132 Series. QuickSetter+ Balancing Valve with flow meter NA Function

INSTRUCTIONS FOR USE BENCH OF FLOW CONTROL AND SEALING MOLD

METRO System Design. Witt&Sohn AG Aug-11

High-performance submersible pressure transmitter For level measurement Model LH-10

INSTRUCTION MANUAL. Demountable Ice Bath Pools

ASVAD THE SIMPLE ANSWER TO A SERIOUS PROBLEM. Automatic Safety Valve for Accumulator Depressurization. (p.p.)

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

Flowmeter. Original operating manual DFM

Analysis of dilatometer test in calibration chamber

Job Sheet 12. Feeding Conductors into Conduit OBJECTIVE PROCEDURE

Multi Fibres. MiniFant M99 insulation blowing MacHinE

APPENDIX D Oil Loading Pipeline - Options

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

Page 1

STRAIGHT CONNECTOR 5 80 N N N N N N N. Copyright 2016 by K-net All Rights Reserved

03/07/2014 V

TIGHTNESS. Glass sealing Thanks to our glass-sealing technology, ODU products can meet the most demanding tightness requirements.

P/N for 1.25" SDR P/N for 1.50" SDR P/N for 2.00" SDR

FIBERGLASS MULTI-GARD MULTI-CELL RACEWAY

Design of an Automated Perfusion Pump James J Higham

Vacuum Excavation in the vicinity of the Wellington Electricity Network

Project Title: Pneumatic Exercise Machine

Internal Sealing of Masts

Instruction Manual. Pipe Friction Training Panel

Figure 1 Schematic of opposing air bearing concept

THE INNER WORKINGS OF A SIPHON Jacques Chaurette p. eng. January 2003

TECHNICAL DESCRIPTION

Cable in Duct Installation: Lubrication Makes the Difference

Discussion and guidance on the definition and qualification of porous loads

CABLE PULLING GUIDELINES

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

In Vessel Composter Installation & Commissioning Manual

Halsey Taylor Owners Manual STOP!

Socket P2RF-05-S P2RF-08-S Clip & Release Lever Nameplate R99-11

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

Arbor Terminator Press Operation Manual For IDT Connectors Order No Engineering No: AM

Fluids always move from high pressure to low pressure. Air molecules pulled by gravity = atmospheric pressure

Transport, mobility and active walking

Semoflex Roboschlepp The PUR cable for cable chains

Rajat Rastogi. Senior Lecturer, Civil Engineering Department, Engineering College Kota Kota , Rajasthan, India

CONTENTS ORIGINAL MANUAL Page General warning 3 Technical data 3. Description of equipment. Rigging arrangements 3. Installing the wire rope 5. Releas

Review: Fluids. container into which it has been poured. changes gases are compressible. pressure changes

Septic Tank Buoyancy Control 101. David Lentz, P.E.

TDUX Inflatable Duct Sealing System 1.0 General Product Information

Product Range Trench Shoring.

Atlas Copco Tools & Assembly Systems. Air Line Accessories Optimizers- FRL

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)

Water Flow Regulators. The Leading Water Flow Regulator Worldwide. Essential Equipment For every injection and blow molding machine

Transcription:

JICABLE 03 A.10.5. Innovative installation method using water as a carrying fluid do install power cables in-pre lubricated ducts in trenches of reduced dimensions C. TRICHARD, Netconcept, France C. BLANC, Novoplastic, France G. PLUMETTAZ, Plumettaz SA, Switzerland. Abstract: This method consists in using pre-lubricated PE ducts in which frictions are considerably diminished, in injecting pressurized water into the duct to carry the cable forward, thus avoiding the sticking effect due to the electrostatic field, and reduce friction heating, in pushing the cable with caterpillars and pulling it with a shuttle-head or, depending on the cable type, in letting the cable being pushed by the drag of the water flow. Advantages of this method: Cable placing does not depend on the duct building activities: reduced site neighborhood disturbance «- Greater cable lengths between splices or manholes Almost no efforts exerted on the cables: greatly reduced installation risks Possibility to follow much more complex routes Résumé: Cette méthode consiste à utiliser des conduits pré lubrifiées en PE pour abaisser les frottements, ï injecter sous pression de l'eau dans la conduite poui porter le câble, annulant ainsi l'effet de collage dû ai champ électrostatique et limitant les échauffements par friction, à pousser le câble par des chenilles et ï le tirer au moyen d'une tête faisant furet ou, selon l«type de câble par la traînée provoquée le flux d'eau. Avantages de la méthode : Insertion des câbles indépendante du génie civil des conduites : impact réduit des chantiers sur le voisinage. Plus grandes longueurs de câbles sans jonction ni chambre Pratiquement plus d'efforts sur les câbles risque d'installation considérablement réduit Possibilité de parcours beaucoup plu: complexes. Keywords: Floating; pre-lubricated ducts; crushing; mobile site Mots clés: Flottage; tube pré-lubrifié; broyage; chantier mobile Review: pulling method Characteristics of the method: Presently, electric power cables are pulled into dry ducts, which are lubricated as the cables are being installed. This method presents following inconveniences: a) integrity of the cable sheath: During pulling operations the cable sheaths are subject to severe damages, to such an extent, that some companies have been looking for a device enabling them to check the quality of the thus installed cable on site. b) integrity of the duct: During operation the pulling line can cut into the duct walls over bends, sometimes cutting right through the walls. c) installation setup: The forces encountered with this method, ofter require line-pulls of several tons applied at the head of the cable and exerting mechanical stresses on it, and the use of powerful, cumbersome and costly means. d) installation lengths: Installation lengths depend on the sinuosity of the route and this in all directions. The pulling method, where the traction force is exerted at the cable extremity, is particularly penalizing. Indeed, the pulling force grows exponentially as the cable passes over bends. It can rapidly 348

reach the maximum installation load allowed for said cable, thus severely limiting the installation lengths over tortuous routes. e) disturbance of the neighborhood: The use of these powerful means produce important obstructions in the traffic lanes and occupy large ground space, with increased inconveniences for the neighbouring population during the whole duration of the works. f) removal of cables by pulling: Such an operation is very questionable under these conditions and in most cases impossible. Pushing/floating cable installation method: In order to offer a truly improved cable installation method, it seemed necessary to involve all actors concerned: - power cable supplier - civil engineering specialist - manufacturer of pre-lubricated plastic ducts - cable installation machine constructor - radically different cable installation method Technical improvements brought forth by the various actors: a) Power cables: The evolution of installation techniques allowed to validate the placement of lighter power cables with lesser mechanical resistance b) civil engineering: with ducts offering increased mechanical protection, trench dimensions can be reduced. Furthermore, on-site crushing of the dug out material, in order to re-use it as backfilling, is also cost-saving, as need for off-site backfilling material becomes redundant. c) pre-lubricated ducts: The coefficient of friction of a manually lubricated dry duct is of approx. 0.12, whereas that of a duct with inner Teflon coating is of approx. 0.06, hence the friction forces are greatly reduced, particularly in bends where they grow exponentially [1]. d) pushing-floating installation method: The idea of replacing air by water has been in use for about fifteen years in the telecommunications field. It allowed for increased installation distances by a factor of 4 to 10, depending on the sinuosity of the route, and at the same time for reduced installation time and personnel, especially at the duct end [2] [3]. Operating principle: There are two possible operating modes, depending on the duct size: either pushing-floating, or pushingfloating-pulling. However, the operating principle of the two modes basically remain the same. PUSHING Pushing-floating Direction of water flow.!! i i ;! i- i- i- s- i- i- i- i- i- i- i i- i- > t FLOATING Pushing-floating-pulling Direction of water flow - j. j. j. ± l!! I 1- i t PUSHING FLOATING PULLING Installation by pushing and floating the cable is safe for personnel and equipment alike as: Installation forces are distributed and kept low by: - Pushing the cable at the duct inlet - Taking advantage of the Archimedes uplift forces exerted on the cable, due to the presence of water in the duct. Said uplift will reduce the friction forces caused by the weight of the cable as normally encountered in dry ducts. - Using the drag forces exerted on the cable by the water flow, or using a shuttle to pull the cable. These installation modes are also efficient as: - One installation team is needed at the drum side only (cable inlet side) with the following tasks: o Monitoring of the correct feeding of cable into the duct o Uncoiling the cable drum o Operating the water supply pump and injection device, operating the cable pusher - The installation speed can reach 50 m per min. depending on drum size and weight, also on quality of drum handling equipment. Types of installed products: Particularly medium-voltage cables are available on the market, either as single phase elements or three- 349

350

351

352