PRODUCT / PROCESS CHANGE NOTIFICATION PCN Date: 9NOV2017 P1/2

Similar documents
Change Notification Cisco R2

Change Notification Cisco R2

Zener Diodes with Surge Current Specification

TVS Diodes Axial Leaded 30 kw > 30KPA-HRA series. Features. 30 kw 8.0 W 400 A. -55 to 175 C. Notes: 8.0 C/W

5KP-HR Series. TVS Diodes Axial Leaded 5 kw > 5KP-HR series. Description. Uni-directional

15KPA-HRA Series. TVS Diodes Axial Leaded 15 kw > 15KPA-HRA series. Descritions

BZD27C3V6P to BZD27C200P

DATA SHEET. BZD23 series Voltage regulator diodes DISCRETE SEMICONDUCTORS Jun 10. Product specification Supersedes data of October 1991

DATA SHEET. BZT03 series Voltage regulator diodes DISCRETE SEMICONDUCTORS Jun 11. Product specification Supersedes data of April 1992

MUR120 Series. SWITCHMODE Power Rectifiers MUR105, MUR110, MUR115, MUR120, MUR130, MUR140, MUR160 ULTRAFAST RECTIFIERS 1.

EALP05RDBRA0 LAMP. Features. Description. Applications. Choice of various viewing angles. Available on tape and reel. Reliable and robust

1224SUBC/C470/S400-A4

LAMP SUGC/S400-A5

204-10SDRD/S530-A3 LAMP. Features. Description. Applications. Revision 1. LifecyclePhase: Expired Period: Forever. Choice of various viewing angles

CONTENTS TABLE OF MAIDA S HISTORY TERMINOLOGY & GENERAL SPECIFICATIONS. iii. LEAD CODES and TAPE & REEL STANDARD SERIES 1 HC SERIES 17

5mm Infrared LED HIR7373B/L289

333-2SURC/H3/S530-A4 LAMP. Features. Description. Applications. 1 Ver.:2 Release Date:12/13/2016 狀態 :Approved( 正式發行 )

5mm Infrared LED,T-1 HIR323C

5mm Infrared LED EAILP05RDDB1

LAMP 339-9SUGSURSUBC/S1174

3mm Infrared LED,T-1 HIR204C

LAMP 336SURSYGWS530-A3

Aluminum Capacitors +85 C, Miniature, Axial Lead

82C288 BUS CONTROLLER FOR PROCESSORS (82C C C288-8)

MS52XX-C&T SMD Pressure Sensor

Series AM3T-VZ 3 Watt DC-DC Converter

Preliminary Datasheet

NON-CATALOG. Features excellent image rejection, 27 db typ. low conversion loss, 7.0 db typ. aqueous washable J-leads for strain relief

ASDX Series Silicon Pressure Sensors

FEATURES AND BENEFITS. Meets UL/EN/IEC , 4Th ed. For EMC*

AMS 2710 PCB pressure sensor module with V output

Wet Tantalum Capacitors Tantalum Case with Glass-to-Tantalum Hermetic Seal CECC Approved

Surface Mount NTC Thermistors. Link: RT Tables. NST Series

Typical Performance 1. LTE 20M ACLR dbm. 2 OIP3 _ measured on two tones with a output power 5dBm/ tone, F2 F1 = 1 MHz.

CD4008BMS. CMOS 4-Bit Full Adder With Parallel Carry Out. Features. Pinout. Logic Diagram. Applications. Description.

Sensoric 4-20 ma Transmitter Board Operation Manual

Monolithic Amplifier CMA-81+ Wideband, High Dynamic Range, Ceramic. DC to 6 GHz. The Big Deal

Technical Data Sheet 339-9SUGSURSUBC/S1182. Features. Descriptions. Applications. Device Selection Guide

DIY - PC - Interface for Suunto Cobra/Vyper/Mosquito

AMS 6915 Board mount pressure sensor with digital output (I²C)

SMDJ-HR Series. TVS Diodes Surface Mount 3000W > SMDJ-HR series. Description. Uni-directional

SPECIFICATIONS FOR APPROVAL

MS54XX Miniature SMD Pressure Sensor

SDP1108/SDP2108 Low Differential Pressure Sensor with fast response time

Parametrable / Programmable Pressure Transmitter

AMS 6916 Board mount pressure sensor with ratiometric analog output

PolySwitch Radial-leaded Resettable Devices

IEP SENSOR BRACKET CHECKOUT AND VERIFICATION. This is a non-hazardous test.

Differential Probes TDP1500 and TDP3500 Datasheet

Type 160 Metallized Polyester Radial Lead Capacitors

SX150A. Features. Typical Applications. Description

Asynchronous, Cascadable 8K/16K/32K/64K x9 FIFOs

Surface Mount Specialty Polymer Solid Aluminum Electrolytic Capacitors

Technical Note. NOR Flash Cycling Endurance and Data Retention. Introduction. TN-12-30: NOR Flash Cycling Endurance and Data Retention.

256/512 /1K /2K/4K x 9 Asynchronous FIFO

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

SENSORS Pressure CALDARO

Watts. xppower.com. Input. General. Environmental. Output. EMC & Safety. Output Voltages from 2.5 V to 48 V. Non-standard Outputs Available

ATM - Analog Pressure Transmitter

Qualification of Fastrak & First Gen Product to Railway applications Shock and Vibration Standard EN 61373

User s Guide Temperature Sensor Converter TSC-599

Miniature Pressure Sensors

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

MS54XX Miniature SMD Pressure Sensor

XSL-360-5E. UV LED 5 mm TECHNICAL DATA. Absolute Maximum Ratings (T a =25 C) Specifications (If=20mA, T a =25 C) Drawing

PRODUCT SPECIFICATION. SFP+ Cage and Cage Assembly 1 of 8 A

Amplified Middle Pressure Sensors

ISO INTERNATIONAL STANDARD. Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using high viscosity fluid

256/512/1K/2K/4K x 9 Asynchronous FIFO

Product Specification Spring Finger

(TRCM) Wire Wound RF SMD Inductor

Type 715P/717P, Orange Drop, High Voltage, Polypropylene Film/Foil

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

BOURNS INDUCTIVE COMPONENTS

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

Programmable pressure and temperature transmitters PTM/RS485

APG. Intrinsically Safe, Heavy Duty Pressure Transducer Series: PT-400

Stand-Alone Bubble Detection System

MS54XX Miniature SMD Pressure Sensor

Pressure Sensor Bridge Configurations

EPRB-2 Pressure Transducer

ATM/Ex - Analog Pressure Transmitter

Specification for Approval

广东锐陆光电科技有限公司 GUANG DONG ELITE PHOTOELECTRIC TECHNOLOGY CO.,LTD. Product Specification

Genesis MX SLM-Series

Specification for Approval

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified

AIS-360 ARINC LS/HS ADAPTER

Programmable pressure and temperature transmitters PTM/RS485

RESISTORS, HEATERS, FLEXIBLE, SINGLE AND DOUBLE LAYER. ESCC Detail Specification No. 4009/002

Agilent Wedge for Probing High-Pitch ICs A Hands-Free Solution for Probing Fine-Pitch ICs

! Warning, refer to accompanying documents.

datasheet M25S 24VDC motor Features & benefits

Specification for Approval

COMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x

ATM.ECO - Analog Pressure Transmitter

ATM.1ST/Ex - High Precision Transmitter

Visualize Nitrogen Gas Consumption

Transcription:

PRODUCT / PROCESS CHANGE NOTIFICATION PCN-000439 Date: 9NOV2017 P1/2 Semtech Corporation, 200 Flynn Road, Camarillo CA 93012 Semtech Canada Corporation, 4281 Harvester Road, Burlington, Ontario L7L 5M4 Canada Semtech Irvine, 5141 California Ave., Suite 100, Irvine CA 92617 Semtech Neuchatel Sarl, Route des Gouttes d Or 40, CH-2000 Neuchatel Switzerland Semtech Bristol - EMEA Limited, Block B, St James Court, Great Park Road, Bristol BS32 4QJ, UK Semtech Corpus Christi SA de CV, Carretera Matamorros Edificio 7, Reynosa, Tamaulipas, Mexico 88780 Semtech Plano, 1101 Resource Drive, Suite 121, Plano TX 75074 Part Number(s) Affected:.TCT Change Details Customer Part Number(s) Affected: N/A Description, Purpose and Effect of Change: a. For the benefit of our customers, Semtech has qualified additional manufacturing capacity for protection products. a. The additional assembly and test site: Diodes, Shanghai, China. b. POD update in the datasheet. POD update to dimension A and A2 Dimensions as outlined below Change Classification Major Minor Is Now: POD Was:- POD Dim Min Nom Max Min Nom Max A 0.89-1.2 0.89-1.12 A2 0.88-1.1 0.88-1.02 Impact to Form, Fit, Function Impact to Data Sheet Yes No New Revision or Date Sep2017 N/A Impact to Performance, Characteristics or Reliability: There is no impact to Function or Reliability for this change. There is an update to the POD in the datasheet. Implementation Date 7FEB2018 Work Week TBA Last Time Ship (LTS) Of unchanged product Sample Availability Not Applicable Additional Capacity 9NOV2017 Affecting Lot No. / Serial No. (SN) Qualification Report Availability Supporting Documents for Change Validation/Attachments: Reliability Report Updated Datasheet. Yes No Not Applicable Included in attachment Rev 3 Semtech Corporation 200 Flynn Road Camarillo Ca 93012 Phone +1 (805) 498-2111

PRODUCT / PROCESS CHANGE NOTIFICATION PCN-000439 Date: 9NOV2017 P2/2 Semtech Business Unit: Semtech Contact Info: Issuing Authority Les Fang Yuen Semtech Corporation Sr. Eng Manager, QA 200 Flynn Road Camarillo, CA 93012 Email: lfangyuen@semtech.com Phone:: (949) 269-4443 [office] FOR FURTHER INFORMATION & WORLDWIDE SALES COVERAGE: http://www.semtech.com/contact/index.html#support Rev 3 Semtech Corporation 200 Flynn Road Camarillo Ca 93012 Phone +1 (805) 498-2111

Rel Job Detail Report by Sublot, by Sequence Contact: Gurmail Sajjan (805) 480 2142 gsajjan@semtech.com Businessunit Protection Reljob# Part_Number, Job Name/Type Fab, Package Rel Job Status Key Dates:. 6359 Package Qual New Product on qualified process with unqualified package ASMC12TVS SOT-23 Rel Testing Complete Passes All Requirements. Job Accepted: 30-May-2017 Requested CD: Actual Start Date: 15-May-2017 ECD for Conditional: Job ECD: 25-Jul-2017 Completed Tasks 1.0 Lot AER4153 AssemblyLot AER4153 DateCode 1719 Seq TaskCode SampleSize Criteria Complete Failures DataSource Results/Comments 1 Data-Prep None None 19-May-2017 Camarillo 2 HTRB_Pre_Elect_150 C_RT24 210 Pass on Zero Fails 07-Jun-2017 0 Camarillo 3 HTRB_150 C_Real Time_0024 210 Pass on Zero Fails 23-Jun-2017 0 Camarillo 4 HTRB_Pre_Elect 210 Pass on Zero Fails 22-May-2017 0 Camarillo 5 BI_BD_Valid NA Meet HTOL Schematics 22-May-2017 Camarillo 6 HTRB_150 C_0072 105 Pass on Zero Fails 26-May-2017 0 Camarillo 7 HTRB_150 C _0408 105 Pass on Zero Fails 09-Jun-2017 0 Camarillo 8 HTS_Pre_Elect 77 Pass on Zero Fails 23-May-2017 0 Camarillo 9 HTS_0168 77 Pass on Zero Fails 30-May-2017 0 Camarillo 10 HTS_0500 77 Pass on Zero Fails 16-Jun-2017 0 Camarillo 11 HTS_1000 77 Pass on Zero Fails 06-Jul-2017 0 Camarillo 12 85/85_W/Pre_Pre Elec 40 0 24-May-2017 0 Camarillo 13 85 C/85%RH_BD_Valid 40 Pass on Zero Fails 24-May-2017 0 Camarillo 14 85/85_120hr_On/Off 40 Pass on Zero Fails 31-May-2017 0 Camarillo 15 Pre_Conditioning_Level_1 NA MSL 1 19-May-2017 0 Camarillo Tuesday, July 25, 2017 Page 1 of 6

Rel Job Detail Report by Sublot, by Sequence Contact: Gurmail Sajjan (805) 480 2142 gsajjan@semtech.com 16 Pre_Elect_Precond 231 Pass on Zero Fails 23-May-2017 0 Camarillo 17 Precond_Temp_Cyc_5cyc 231 Pass on Zero Fails 23-May-2017 0 Camarillo 18 Precond_HTS_24hr 231 Pass on Zero Fails 24-May-2017 0 Camarillo 19 Precond_85/85_NoElec168hr 231 Pass on Zero Fails 31-May-2017 0 Camarillo 20 Precond_260 C_IR_Ref_Char 231 Pass on Zero Fails 31-May-2017 0 Camarillo 21 T/C_Pre_Elect 77 Pass on Zero Fails 31-May-2017 0 Camarillo 22 T/C_wPre_0250 77 Pass on Zero Fails 06-Jun-2017 0 Camarillo 23 T/C_wPre_0500 77 Pass on Zero Fails 13-Jun-2017 0 Camarillo 24 T/C_wPre_1000 77 Pass on Zero Fails 21-Jun-2017 0 Camarillo 25 Cross_Section TC 1000 Cyc 15 21-Jun-2017 Camarillo 26 85 C/85%RH_W/Pre_Pre Elec 77 Pass on Zero Fails 21-May-2017 0 Camarillo 27 85 C/85%RH_BD_Valid 77 Pass on Zero Fails 01-Jun-2017 0 Camarillo 28 85 C/85%RH_Biased_168hrs 77 Pass on Zero Fails 08-Jun-2017 0 Camarillo 29 85 C/85%RH_Biased_500hrs 77 Pass on Zero Fails 23-Jun-2017 0 Camarillo 30 85 C/85%RH_Biased_1000hrs 77 Pass on Zero Fails 14-Jul-2017 0 Camarillo 31 Cross_Section 85 C/85%RH 15 14-Jul-2017 Camarillo 32 CSAM Analysis 22 Pass on Zero Fails 24-May-2017 0 Camarillo 33 Precond_Temp_Cyc_5cyc 22 Pass on Zero Fails 25-May-2017 0 Camarillo 34 Precond_HTS_24hr 22 Pass on Zero Fails 26-May-2017 0 Camarillo 35 Precond_85/85_NoElec168hr 22 Pass on Zero Fails 02-Jun-2017 0 Camarillo 36 Precond_260 C_IR_Ref_Char 22 Pass on Zero Fails 02-Jun-2017 0 Camarillo 37 CSAM Analysis 22 Pass on Zero Fails 06-Jun-2017 0 Camarillo 38 Construct_Package 5 unique packaged devices minimum. No Major Findings, Q&R to review construction analysis report. 12-Jun-2017 0 Camarillo 39 Rider_Card_Wash/Bake 231 22-May-2017 0 Camarillo 40 Pack_Clos 0 0 17-Jul-2017 Camarillo Tuesday, July 25, 2017 Page 2 of 6

Rel Job Detail Report by Sublot, by Sequence Contact: Gurmail Sajjan (805) 480 2142 gsajjan@semtech.com 2.0 Lot AER4177 AssemblyLot AER4177 DateCode 1719 Seq TaskCode SampleSize Criteria Complete Failures DataSource Results/Comments 1 Data-Prep None None 19-May-2017 Camarillo 2 HTRB_Pre_Elect_150 C_RT24 210 Pass on Zero Fails 07-Jun-2017 0 Camarillo 3 HTRB_150 C_Real Time_0024 210 Pass on Zero Fails 29-Jun-2017 0 Camarillo 4 HTRB_Pre_Elect 210 Pass on Zero Fails 22-May-2017 0 Camarillo 5 BI_BD_Valid NA Meet HTOL Schematics 22-May-2017 6 HTRB_150 C_0072 105 Pass on Zero Fails 26-May-2017 0 Camarillo 7 HTRB_150 C _0408 105 Pass on Zero Fails 09-Jun-2017 0 Camarillo 8 HTS_Pre_Elect 77 Pass on Zero Fails 23-May-2017 0 Camarillo 9 HTS_0168 77 Pass on Zero Fails 30-May-2017 0 Camarillo 20 Precond_260 C_IR_Ref_Char 154 Pass on Zero Fails 31-May-2017 0 Camarillo 21 T/C_Pre_Elect 77 Pass on Zero Fails 31-May-2017 0 Camarillo 22 T/C_wPre_0250 77 Pass on Zero Fails 06-Jun-2017 0 Camarillo 23 T/C_wPre_0500 77 Pass on Zero Fails 13-Jun-2017 0 Camarillo 24 T/C_wPre_1000 77 Pass on Zero Fails 21-Jun-2017 0 Camarillo 25 Cross_Section TC 1000 Cyc 15 21-Jun-2017 Camarillo Tuesday, July 25, 2017 Page 3 of 6 Camarillo 10 HTS_0500 77 Pass on Zero Fails 16-Jun-2017 0 Camarillo 11 HTS_1000 77 Pass on Zero Fails 06-Jul-2017 0 Camarillo 12 85/85_W/Pre_Pre Elec 40 Pass on Zero Fails 24-May-2017 0 Camarillo 13 85 C/85%RH_BD_Valid 40 Pass on Zero Fails 24-May-2017 0 Camarillo 14 85/85_120hr_On/Off 40 Pass on Zero Fails 31-May-2017 0 Camarillo 15 Pre_Conditioning_Level_1 NA MSL 1 19-May-2017 0 Camarillo 16 Pre_Elect_Precond 231 Pass on Zero Fails 23-May-2017 0 Camarillo 17 Precond_Temp_Cyc_5cyc 231 Pass on Zero Fails 23-May-2017 0 Camarillo 18 Precond_HTS_24hr 231 Pass on Zero Fails 24-May-2017 0 Camarillo 19 Precond_85/85_NoElec168hr 231 Pass on Zero Fails 31-May-2017 0 Camarillo

Rel Job Detail Report by Sublot, by Sequence Contact: Gurmail Sajjan (805) 480 2142 gsajjan@semtech.com 26 85 C/85%RH_W/Pre_Pre Elec 77 Pass on Zero Fails 31-May-2017 0 Camarillo 27 85 C/85%RH_BD_Valid 77 Pass on Zero Fails 01-Jun-2017 0 Camarillo 28 85 C/85%RH_Biased_168hrs 77 Pass on Zero Fails 08-Jun-2017 0 Camarillo 29 85 C/85%RH_Biased_500hrs 77 Pass on Zero Fails 23-Jun-20177 0 Camarillo 30 85 C/85%RH_Biased_1000hrs 77 Pass on Zero Fails 14-Jul-20177 0 Camarillo 31 Cross_Section 85 C/85%RH 15 14-Jul-2017 Camarillo 32 CSAM Analysis 22 Pass on Zero Fails 24-May-2017 0 Camarillo 33 Precond_Temp_Cyc_5cyc 22 Pass on Zero Fails 25-May-2017 0 Camarillo 34 Precond_HTS_24hr 22 Pass on Zero Fails 26-May-2017 0 Camarillo 35 Precond_85/85_NoElec168hr 22 Pass on Zero Fails 02-Jun-2017 0 Camarillo 36 Precond_260 C_IR_Ref_Char 22 Pass on Zero Fails 02-Jun-2017 0 Camarillo 37 CSAM Analysis 22 Pass on Zero Fails 06-Jun-2017 0 Camarillo 38 Rider_Card_Wash/Bake 213 22-May-2017 0 Camarillo 39 Pack_Clos 0 0 17-Jul-2017 Camarillo 3.0 Lot AER4178 AssemblyLot AER4178 DateCode 1719 Seq TaskCode SampleSize Criteria Complete Failures DataSource Results/Comments 1 Data-Prep None None 19-May-2017 Camarillo 2 HTRB_Pre_Elect_150 C_RT24 210 Pass on Zero Fails 13-Jun-2017 0 Camarillo 3 HTRB_150 C_Real Time_0024 210 Pass on Zero Fails 29-Jun-2017 0 Camarillo 4 HTRB_Pre_Elect 210 Pass on Zero Fails 22-May-2017 0 Camarillo 5 BI_BD_Valid NA Meet HTOL Schematics 22-May-2017 6 HTRB_150 C_0072 105 Pass on Zero Fails 26-May-2017 0 Camarillo 7 HTRB_150 C _0408 105 Pass on Zero Fails 09-Jun-2017 0 Camarillo 8 HTS_Pre_Elect 77 Pass on Zero Fails 23-May-2017 0 Camarillo 9 HTS_0168 77 Pass on Zero Fails 30-May-2017 0 Camarillo Tuesday, July 25, 2017 Page 4 of 6 Camarillo 10 HTS_0500 77 Pass on Zero Fails 16-Jun-2017 0 Camarillo 11 HTS_1000 77 Pass on Zero Fails 06-Jul-2017 0 Camarillo

Rel Job Detail Report by Sublot, by Sequence Contact: Gurmail Sajjan (805) 480 2142 gsajjan@semtech.com 12 85/85_W/Pre_Pre Elec 40 24-May-2017 0 Camarillo 13 85 C/85%RH_BD_Valid 40 Pass on Zero Fails 24-May-2017 0 Camarillo 14 85/85_120hr_On/Off 40 Pass on Zero Fails 31-May-2017 0 Camarillo 15 Pre_Conditioning_Level_1 NA MSL 1 19-May-2017 0 Camarillo 16 Pre_Elect_Precond 231 Pass on Zero Fails 23-May-2017 0 Camarillo 17 Precond_Temp_Cyc_5cyc 231 Pass on Zero Fails 23-May-2017 0 Camarillo 18 Precond_HTS_24hr 231 Pass on Zero Fails 24-May-2017 0 Camarillo 19 Precond_85/85_NoElec168hr 231 Pass on Zero Fails 31-May-2017 0 Camarillo 20 Precond_260 C_IR_Ref_Char 231 Pass on Zero Fails 31-May-2017 0 Camarillo 21 T/C_Pre_Elect 77 Pass on Zero Fails 31-May-2017 0 Camarillo 22 T/C_wPre_0250 77 Pass on Zero Fails 06-Jun-2017 0 Camarillo 23 T/C_wPre_0500 77 Pass on Zero Fails 13-Jun-2017 0 Camarillo 24 T/C_wPre_1000 77 Pass on Zero Fails 21-Jun-2017 0 Camarillo 25 Cross_Section TC 1000 Cyc 15 21-Jun-2017 Camarillo 26 85 C/85%RH_W/Pre_Pre Elec 154 Pass on Zero Fails 31-May-2017 0 Camarillo 27 85 C/85%RH_BD_Valid 154 Pass on Zero Fails 01-Jun-2017 0 Camarillo 28 85 C/85%RH_Biased_168hrs 154 Pass on Zero Fails 08-Jun-2017 0 Camarillo 29 85 C/85%RH_Biased_500hrs 154 Pass on Zero Fails 23-Jun-2017 0 Camarillo 30 85 C/85%RH_Biased_1000hrs 154 Pass on Zero Fails 14-Jul-2017 0 Camarillo 31 Cross_Section 85 C/85%RH 15 14-Jul-2017 0 Camarillo 32 CSAM Analysis 22 Pass on Zero Fails 24-May-2017 0 Camarillo 33 Precond_Temp_Cyc_5cyc 22 Pass on Zero Fails 25-May-2017 0 Camarillo 34 Precond_HTS_24hr 22 Pass on Zero Fails 26-May-2017 0 Camarillo 35 Precond_85/85_NoElec168hr 22 Pass on Zero Fails 02-Jun-2017 0 Camarillo 36 Precond_260 C_IR_Ref_Char 22 Pass on Zero Fails 02-Jun-2017 0 Camarillo 37 CSAM Analysis 22 Pass on Zero Fails 06-Jun-2017 0 Camarillo 38 Rider_Card_Wash/Bake 231 22-May-2017 0 Camarillo Tuesday, July 25, 2017 Page 5 of 6

Rel Job Detail Report by Sublot, by Sequence Contact: Gurmail Sajjan (805) 480 2142 gsajjan@semtech.com 39 Pack_Clos 0 0 17-Jul-2017 Camarillo Tuesday, July 25, 2017 Page 6 of 6

Asymmerical TVS Diode for Extended Common-Mode RS-485 PROTECTION PRODUCTS Description The transient voltage suppressor (TVS) diode is designed for asymmetrical (12V to -7V) protection in multi-point data transmission standard RS-485 applications. The may be used to protect devices from transient voltages resulting from electrostatic discharge (ESD), eletrical fast transients (EFT), and lightning. The features more than 500 Watts (tp = 8/20 μs) of power handling capability to accommodate the higher transient voltage levels which may be expected in extended commom mode applications. This provides higher equipment reliability and eliminates the guess work required when using Zener diodes that are not rated to handle such transient conditions. The replaces four discrete components by integrating two 12V and two 7V TVS diodes in a single package. The integrated design aids in reducing voltage over-shoot associated with trace inductance. The low clamping voltage of minimizes the stress on the protected transceiver. Features Transient Protection to s IEC 61000-4-2 (ESD): ±30kV (Air), ±30kV (Contact) s IEC 61000-4-4 (EFT): 40A (5/50ns) s IEC 61000-4-5 (Lightning): 21A for 12V TVS & 38A for 7V TVS (tp = 8/20µs) Protects two +12V to -7V lines Peak pulse power (tp = 8/20μs): 500-700W Low capacitance Low clamping voltage Solid-State Silicon-Avalanche Technology Mechanical Characteristics JEDEC SOT23 Package Molding Compound Flammability Rating: UL 94V-0 Pb-Free, Halogen Free, RoHS/WEEE compliant Marking: 712 Packaging: Tape and Reel Applications RS-485 tranceivers with extended common mode range Security systems Automatic Teller Machines HFC systems Networks Circuit Diagram Schematic and Pin Configuration I/O 1 I/O 2 1 2 3 12V 12V 7V 7V GND 3 1 2 SOT23 (Top View) Final Datasheet Rev 6.0 10/17/2017 www.semtech.com Page 1 Semtech

Absolute Maximum Ratings Rating Symbol Value Units Peak Pulse Power (tp = 8/20µs) P PK 550-700 W Peak Pulse Current (tp = 8/20µs), Pin 1 or 2 to Pin 3 Peak Pulse Current (tp = 8/20µs), Pin 3 to Pin 1 or 2 I PP 21 ESD per IEC 61000-4-2 (Contact) (1) 30 V ESD per IEC 61000-4-2 (Air) (1) ESD 30 Lead Soldering Temperature T L 260 (10 sec.) O C Operating Temperature T J -55 to +125 O C Storage Temperature T STG -55 to +150 O C 38 A kv Electrical Characteristics (T=25 O C unless otherwise specified) Parameter Symbol Conditions Min. Typ. Max. Units Pin 1 or Pin 2 to 3 12 Reverse Stand-Off Voltage V RWM Pin 3 to Pin 1 or 2 7 Reverse Breakdown Voltage V BR I t = 1mA, Pin 1 or 2 to Pin 3 13.3 V I t = 1mA, Pin 3 and Pin 1 or 2 7.5 V R = 12 V, Pin 1 or Pin 2 to 3 1 Reverse Leakage Current I R V R = 7 V, Pin 3 to Pin 1 or 2 20 I PP = 5A, Pin 1 or 2 to Pin 3, tp = 8/20µs 20 Clamping Voltage V C I PP = 5A, Pin 3 to Pin 1 or 2, tp = 8/20µs 10 I PP = 21A, Pin 1 or 2 to Pin 3, tp = 8/20µs 26 Clamping Voltage V C I PP = 38A, Pin 3 to Pin 1 or 2, tp = 8/20µs 19 Junction Capacitance C J V R = 0V Pin 1 or 2 to Pin 3 75 Pin 3 to Pin 1 or 2 75 V R =12V Pin 1 or 2 to Pin 3 57 V R =7V Pin 3 to Pin 1 or 2 35 V μa V V pf Notes: (1): ESD Gun return path to Ground Reference Plane (GRP) (2): Transmission Line Pulse Test (TLP) Settings: tp = 100ns, tr = 0.2ns, I TLP and V TLP averaging window: t 1 = 70ns to t 2 = 90ns. (3): Dynamic resistance calculated from I TLP = 4A to I TLP = 16A. Final Datasheet Rev 6.0 10/17/2017 www.semtech.com Page 2 Semtech

Typical Characteristics Non-Repetitive Peak Pulse Power vs. Pulse Time Power Derating Curve Peak Pulse Power - P PP (kw) 10 1 0.1 Pin 3 to Pin 1 or 2 Pin 1 or 2 to Pin 3 % of Rated Power or I PP 120 100 80 60 40 T A = 25 O C 0.01 0.1 1 10 100 1000 Pulse Duration - tp (µs) 20 0 DR040514-25-125-150 0 25 50 75 100 125 150 Ambient Temperature - T A ( O C) Clamping Voltage vs. Peak Pulse Current (tp = 8/20µs) Capacitance vs. Reverse Voltage 30 80 25 70 Clamping Voltage - V C (V) 20 15 10 5 0 Pin 1 or 2 to Pin 3 Pin 3 to Pin 1 or 2 8x20us 7V 0 5 10 15 20 25 30 35 40 Peak Pulse Current - I PP (A) Capacitance - C J (pf) 60 50 40 30 20 10 0 T A = 25 O C. f = 1 MHz. Pin 3 to Pin 1 or 2 0 2 4 6 8 10 12 14 Reverse Voltage - V R (V) Pin 1 or 2 to Pin 3 _AR_CAPvV TLP IV Curve (Pin 1 or 2 to Pin 3) TLP IV Curve (Pin 3 to Pin 1 or 2) 35 30 25 T A = 25 O C t P = 100ns, t R = 0.2ns t MEAS = 70-90ns 5 0-5 T A = 25 O C t P = 100ns t R = 0.2ns t MEAS = 70-90ns TLP Current (A) 20 15 10 5 0 _TLP_POS -5 0 5 10 15 20 25 TLP Voltage (V) TLP Current (A) -10-15 -20-25 _TLP_NEG -30-14 -12-10 -8-6 -4-2 0 TLP Voltage (V) Final Datasheet Rev 6.0 10/17/2017 www.semtech.com Page 3 Semtech

Typical Characteristics ESD Clamping Voltage (+8kV Contact per IEC 61000-4-2) ESD Clamping Voltage (-8kV Contact per IEC 61000-4-2) 180 0 Clamping Voltage - V C (V) 160 140 120 100 80 60 40 20 T A = 25 O C. Waveform IEC61000-4-2 +8kV. Measured with and corrected for 50Ω, 40dB Attenuator. 50Ω Scope Input Impedance, 2GHz BW. ESD Gun Return connected to Ground Reference Plane. _P8_ESD Clamping Voltage - V C (V) -20-40 -60-80 -100-120 -140-160 T A = 25 O C. Waveform IEC61000-4-2-8kV. Measured with and corrected for 50Ω, 40dB Attenuator. 50Ω Scope Input Impedance, 2GHz BW. ESD Gun Return connected to ESD Ground Plane. 0-10 10 30 50 70 90 Time (ns) _IEC_N8_ESD -180-10 10 30 50 70 90 Time (ns) Final Datasheet Rev 6.0 10/17/2017 www.semtech.com Page 4 Semtech

Application Information Device Connection for Protection of Two RS-485 Data Lines EIA RS-485 specifies a ±7V ground difference between devices on the bus. This permits the bus voltage to range from +12V (5V + 7V) to -7V (0-7V). VCC1 5V RS-485 Common Mode Voltages A 4000 ft Twisted Pair B VCC2 5V The is designed to protect two RS-485 data lines in extended common mode applications. The may be used to protect devices from transient voltages resulting from ESD, EFT, and lightning. The device is designed with asymmetrical operating voltages for optimum protection. The TVS diodes at pins 1 and 2 have a working voltage of 12 volts. These pins are connected to the differential data line pairs. The TVS diodes at pin 3 have a working voltage of 7 volts. Pin 3 is connected to ground. The internal TVS diodes of the will protect the transceiver input from positive transient votlage spikes greater than 12V and negative spikes greater than 7V. INPUT GND SS SS B 100 - + 12V to -7V Common mode voltage RS-485 Protection Circuit RT 100 A VCC 5V SM05 OUTPUT A series current limiting resistor may be added in applications requiring enhanced surge immunity. D Circuit Board Layout Recommendations Good circuit board layout is critical for the suppression of fast rise time transients such as ESD. The following guidelines are recommended: 12V 7V 12V 7V R Place the near the input terminals or connectors to restrict electromagnetic coupling. Minimize the path length between the and the protected line. This minimizes voltage overshoot due to parastic inductance of board traces. Use ground planes whenever possible. Long, single trace ground conductors should be avoided. The ground pin (Pin 3) should be connected directly to a ground plane on the circuit board for best results. Minimize all conductive loops including power and ground loops. Never run critical signals near board edges. Final Datasheet Rev 6.0 10/17/2017 www.semtech.com Page 5 Semtech

Outline Drawing - SOT-23 e1 3 1 2 e B E1 bxn bbb E C A B DIMENSIONS MILLIMETERS DIM MIN NOM MAX A 0.89-1.20 A1 0.01-0.10 A2 0.88-1.10 b 0.30-0.51 c 0.08-0.18 D 2.80 2.90 3.04 E1 1.20 1.30 1.40 E 2.10-2.64 e 1.90 BSC e1 0.95 BSC L 0.40 0.50 0.60 L1 (0.55) N 3 0 0-8 aaa 0.10 bbb 0.20 D A aaa C A2 A SEATING PLANE C A1 H NOTES: 1. GAUGE PLANE SEATING PLANE SEE DETAIL A 2. DATUMS -A- AND -B- TO BE DETERMINED AT DATUM PLANE -H- 3. SIDE VIEW 0.25 CONTROLLING DIMENSIONS ARE IN MILLIMETERS (ANGLES IN DEGREES). DIMENSIONS "E1" AND "D" DO NOT INCLUDE MOLD FLASH, PROTRUSIONS OR GATE BURRS. C L L1 DETAIL A 0 c Land Pattern - SOT-23 X (C) G Y Z DIMENSIONS DIM MILLIMETERS C (2.20) G 0.80 E1 0.95 E 1.90 X 1.00 Y 1.40 Z 3.60 E1 E NOTES: 1. 2. THIS LAND PATTERN IS FOR REFERENCE PURPOSES ONLY CONSULT YOUR MANUFACTURING GROUP TO ENSURE YOUR COMPANY'S MANUFACTURING GUIDELINES ARE MET. 3. CONTROLLING DIMENSIONS ARE IN MILLIMETERS (ANGLES IN DEGREES). REFERENCE IPC-SM-782A. Final Datasheet Rev 6.0 10/17/2017 www.semtech.com Page 6 Semtech

Marking Code 3 712 1 2 Tape and Reel Specification 712 712 712 Pin 1 Location User Direction of feed Ordering Information Part Number Qty per Reel Reel Size Carrier Tape Pitch.TCT 3,000 7 Inch Plastic 4mm MicroClamp and uclamp are registered trademarks of Semtech Corporation. Final Datasheet Rev 6.0 10/17/2017 www.semtech.com Page 7 Semtech

IMPORTANT NOTICE Information relating to this product and the application or design described herein is believed to be reliable, however such information is provided as a guide only and Semtech assumes no liability for any errors in this document, or for the application or design described herein. Semtech reserves the right to make changes to the product or this document at any time without notice. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. Semtech warrants performance of its products to the specifications applicable at the time of sale, and all sales are made in accordance with Semtech s standard terms and conditions of sale. SEMTECH PRODUCTS ARE NOT DESIGNED, INTENDED, AUTHORIZED OR WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT APPLICATIONS, DEVICES OR SYSTEMS, OR IN NUCLEAR APPLICATIONS IN WHICH THE FAILURE COULD BE REASONABLY EXPECTED TO RESULT IN PERSONAL INJURY, LOSS OF LIFE OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE. INCLUSION OF SEMTECH PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO BE UNDERTAKEN SOLELY AT THE CUSTOMER S OWN RISK. Should a customer purchase or use Semtech products for any such unauthorized application, the customer shall indemnify and hold Semtech and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs damages and attorney fees which could arise. The Semtech name and logo are registered trademarks of the Semtech Corporation. All other trademarks and trade names mentioned may be marks and names of Semtech or their respective companies. Semtech reserves the right to make changes to, or discontinue any products described in this document without further notice. Semtech makes no warranty, representation or guarantee, express or implied, regarding the suitability of its products for any particular purpose. All rights reserved. Semtech 2015 Contact Information Semtech Corporation 200 Flynn Road, Camarillo, CA 93012 Phone: (805) 498-2111, Fax: (805) 498-3804 www.semtech.com Final Datasheet Rev 6.0 10/17/2017 Page 8 Semtech