Instrument Operating Manual

Similar documents
User guide DIAPHRAGM SEALS. Industrial instrumentation for Pressure and Temperature

Temperature gauge Installation Guide

Pressure gauges EN Safety pressure gauges solid-front PBXSF100, PBXSF150 (1.20) Functional and constructive characteristics

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Contents. Operating instructions. Pressure switch, heavy-duty version Model PSM-520

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Pressure Gauges. Version 2018 Revised 01/2018

GI Series Diaphragm Pressure Gauge Guard

Pressure measurement. Pressure gauges

WIKA INSTRUMENT CORPORATION

Siphon vessel / Priming aid

CP10 Sensor Installation and Maintenance Instructions

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

Manual Actuated Boiler Blowdown Valves

TA10A and TA10P Steam Tracing Temperature Control Valves Installation and Maintenance Instructions

Installation and Maintenance Instruction Manual

PVC Quick Drain Valve

Installation and commissioning instructions 255 series and 256 series

Pressure gauges EN All stainless steel construction PBX100, PBX150 (1.18) Functional and constructive characteristics

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

Pressure Reducing Valve DMV 750 set range: bar

Rapidmain Installation Guide

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

MAINTENANCE AND OPERATING MANUAL

SOLFRUNT Model /2" (63mm) and 4" (100mm) Stainless Steel Gauges

130400A 1/2 NPT Female A 3/4 NPT Female A 1 NPT Female A 1 1/4 NPT Female A 1 1/2 NPT Female A 2 NPT Female

KOBOLD KSM FLOWMETER. User Instructions

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Dial Adjustment)

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

Buying more than 11 gauges? Call Lesman for additional discounts.

Series AMJ. Drain Separator for Vacuum

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

PRAHER PLC-MP AQUASTAR MANAUL 2009

Mechanical Pressure Measurement

Installation and Maintenance Instruction Manual

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

Type /2-Way Globe Valve 3/2-Wege-Geradsitzventil Vanne à siège droit 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Cautions : 1. Be careful when you release the Stop Fitting with some internal pressure

PV4 and PV6 Piston Valves

This written Compressed Gas Plan is kept at the corporate office and in the written Safety & Health Program.

Operating instructions for KLINGER SCHÖNEBERG ball valves type RK-Chemoball, type RK-Proball and type RK-Ecoball

Cautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

Adjustment of SF6 pressure

Peak Pressure Indicator MSI-3

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)

Yoke Block Instruction Manual

New! SOLFRUNT 659 Stainless Steel Pressure Gauges. Process Gauges A18

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

MODELS (2 foot Version) (4 foot Version)

Pressure Reducing Valve DMV 750

Lab Cock. Contents. User s Manual (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

VAPOMATIC ANESTHETIC VAPORIZER

453 Series Steam Heated Vaporizing Regulator

Model /2" (63mm), 4" (100mm) and 6" (160mm) Open Front Stainless Steel Gauges

Dri-Line Mk3 Monnier Compressed Air Drain Trap

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

BGA158 Series CE Approved Class A Shutoff Gas Valve

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators

Pressure Reducing Valve DMV 755 set range: 1,0-9,0 bar

Composite Pistol-Type Air Needle Scaler OWNER S MANUAL

Bourdon tube pressure gauges with glycerine filling, for chemical applications EN 837-1

Dual Solenoid Gas Valve Installation

A Rationale for Pressure Relief Device(s) Qualification Requirements (LH2)

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

FV Flash Vessel Installation and Maintenance Instructions

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

DPC-30 DPC-100. Reference Manual

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating Instructions

bathrooms.com Concentric Thermostatic Shower Mixers Cleaning and Care Installation Manual Contents

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

McDaniel. General Service Gauges. (Brass Internals) Stainless Steel Case 1 1 /2 and 2 1 /2 Gauges. All Brass 2 and 2 1 /2 Gauges M C

Installation and Maintenance Instruction Manual

(1) Type (2) Thread size (T) (3) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

TITAN FLOW CONTROL, INC.

DCV1, DCV3 and DCV3LT Disc Check Valves Installation and Maintenance Instructions

Accessories. Differential pressure gauges for air and gas MAG-A & MAG-G (E5275 rev /04/2010)

G96 Series BASOTROL Dual Operator Valve

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment)

Caution: Safety Precautions: Installation, Operation & Maintenance Manual. For Modentic Needle Valves with Threaded Ends

Related Products: Auto Drain Valve. Model/Specifications. Model

Medical Gas Control Panel

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

Instruction Manual Contact Pressure Vacuum Gauge

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

INTENDED USE TECHNICAL SPECIFICATIONS

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Transcription:

Instrument Operating Manual

INDEX NO. SUBJECT PAGE 1 INFORMATION 3 2 SAFETY 4 3 INTENDED USE 4 4 COMMISSIONING & OPERATION 5 5 MAINTENANCE 6 2

INFORMATION The pressure gauges described in the operating instructions has been manufactured using state-of-the-art technology. All components are subject to stringent quality and environmental criteria and safe-guarding our skilled personnel during production. Our integrated management systems are certified to ISO 9001:2008, ISO 14001:2004 & BS OHSAS 18001:2007. These operating instructions contain important information on handling the pressure gauges. Working safely requires that all safety instructions and work instructions are observed. Observe the relevant local accident prevention regulations and general safety regulations for the pressure gauge s range of use. The operating instructions are part of the instruments and must be kept in the immediate vicinity of the pressure gauge and readily accessible to skilled personnel at any time. Skilled personal must have carefully read and understood the operating instruction manual prior to beginning of the mounting. Manufacturer s liability is void in the case of any damage caused by using the product contrary to its intended use, non-compliance with these operating instructions, assignment of insufficient qualified skilled personnel or unauthorized modifications to the pressure gauges. This instruction manual is subject to change without notice and the manufacturer reserves all rights. WARNING! / CAUTION!..indicates potentially dangerous situations. INFORMATIONS!..indicates recommendations and information for efficient and trouble-free operation. 3

SAFETY WARNING! Before installation, commissioning and operation ensure that the appropriate pressure gauge has been selected in terms of measuring range, design and specific measuring conditions. Before installation, commissioning and operation ensure that the pressure gauge material used is chemically resistant / neutral to the medium being measured and that it withstands the mechanical stresses from the process. Non-observance can result in serious injury and/or damage to equipment. In order to guarantee the measuring accuracy and long-term stability specified, the corresponding load limits must be observed. CAUTION! INTENDED USE These pressure gauges are used for measuring pressure within hazardous areas in industrial applications. The pressure gauge has been designed and built solely for the intended use described here, and may only be used accordingly. The manufacturer shall not be liable for claims of any type based on operation contrary to the intended use. It is not advisable to use the instruments for measuring pressures near zero, as in that range the accuracy tolerance can represent a significant percentage of the applied pressure. It is difficult to insulate the instrument from ambient temperature that is too high or too Low. One solution is to position it further away from the source of cold or heat, when this is possible. 4

COMMISSIONING & OPERATION MOUNTING To facilitate removal for maintenance purposes, a shut - off valve can be installed between the pressure gauges and plant. The pressure connection must be watertight. If the pressure connection has a cylindrical thread, the seal is achieved using an O-Ring clamped between the two flat sealing surfaces, one on the pressure connection and the other on the instrument s process connection. If the pressure connection has a tapered thread, the seal is achieved by simply screwing the connection onto the coupling through the mating of the threads. It is common practice to wrap PTFE tape around the male thread before coupling. In both cases the torque must be applied using two hexagonal spanners, one on the flat faces of the instruments / process coupling and the other on the pressure connection. Do not use the case as a means of tightening as this may cause damage to the instrument. When pressurizing the system for the first time, check the tightness of the connection seal. All instruments must be mounted in such a way that the dial is vertical, unless otherwise indicated on the dial itself. When the instrument includes a safety device (Check dial symbol S ), this must be at least 20 mm from any other object. For wall or panel mount instruments make sure that the pipe conveying the pressurized fluid is connected to the instrument coupling without exerting torsion or force. Liquid Filled Cases: Liquid Filling is generally used to dampen the vibrations of moving parts due to vibrations and / or pulsations. Great care must be taken in choosing the damping liquid for instruments that will be used with oxidizing media such as oxygen, chlorine, nitric acid hydrogen peroxide, est.,. In the presence of oxidizing agents, there is possible risk of chemical reaction, ignition and explosive of the instrument. In this case it is necessary to use fluorine or chlorine based filling liquids /Jelly filled Movement to use. In order to contain the damping liquid inside the case, the pressure gauges are built and supplied in a sealed construction. In some cases, during installation it is necessary to ventilate the case following the instructions on the label affixed to the instrument itself. 5

Special care must be taken with the type of filling liquid used and its usage limitations as a function of ambient used. Filling Liquids Glycerin 98% Silicon Oil Fluoridated Liquid Ambient Temperature +15 65 C (+60.+150 F) -45 65 C (+60.+150 F) -45 65 C (+60.+150 F) Mechanical stress: Pressure gauges must not be subjected to mechanical stress. If the installation points are subject to mechanical stresses, the instrument must be installed at a distance and connected using flexible hoses. The instruments selected must be of the surface, wall or panel mount type. The characteristic of the instruments may be must effected during transport, despite adequate packing, and must be checked before use. Correct calibration can be checked by excluding the instrument from the process by means of the shut off valve and checking that the pointer returns to the zero mark ( Unless the temperature varies greatly from 20 C) Failure of the pointer to return to zero indicates serious damage to the instrument. MAINTENANCE Maintenance of accuracy should be confirmed by routine checks & must be carried out by competent personnel using suitable testing equipment. Every 3/6 months after installation, check the accuracy and the wear on moving parts and the state of corrosion on the measuring element. For instrument used on plant subject to demanding conditions (Vibrations, Pulsating pressures, corrosive media, and sediments etc.) replace them after the time intervals indicated in the plant procedures. The calibration and testing must be compatible with the measured media in the pressurized system. Fluids containing hydrocarbons must not be used when the measured medium is oxygen or any other oxidizing substance. The indicator and switching function should be checked once or twice every year. The gauge must be disconnected from the process to check with a pressure testing device. Storage: Instrument kept in their original standard packing (cardboard box) must be stored in a closed area and protected from moisture: in this case no special attention is required.if the instruments are packed in special materials (Wooden crates lined with tar paper or barrier bags) it is preferable to store them in a closed room if possible, or in any cause in an area protected from the elements, the condition of packed materials should be checked every 3-4 months, especially if the crates are exposed to the elements. The temperature of the storage area should be between -20 and +65 C, except where otherwise specified on the catalogue data sheet. 6