DBI version 002 User Manual US version Free Balloon Flight Instrument

Similar documents
Digitool Instruments AB DBI3 US User Manual Free Balloon Flight Instrument

Altimeter and Compass Watch Instruction Manual

DT 630 ALTIMETER, BAROMETER AND COMPASS WATCH OPERATING INSTRUSTIONS

MicroTim XB. User Manual. Precision Digital Barometric Altimeter / Barometer / VSI. Document Revision 1.0 Firmware Version 3.0

Multifunction Altimeter/Variometer AV1

The Military CYPRES Quick Guide For Operators

S-TEC. Pilot s Operating Handbook

Revision Number Revision Date Insertion Date/Initials 1 st Ed. Oct 26, 00 2nd Ed. Jan 15, 08

Short manual testo

Manufactured by: AAA

WATCH COLLECTION NG701 SERIES INSTRUCTION MANUAL

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

ECHO MANUAL WARNING. L B A ltim e te rs. ECHO is a trademark of LB Altimeters, Denmark

Columbus Instruments

5 Function Indicator. Outside Air Temperature (C) Outside Air Temperature (F) Pressure Altitude Density Altitude Aircraft Voltage STD TEMP SL 15000

Pilot s Operating Handbook

BUBBLER CONTROL SYSTEM

MODEL 6600 Rev. B4 USER'S MANUAL LAVERSAB INC., 505 GILLINGHAM LANE. SUGAR LAND TX (281) FAX: (281)

BAPI Pressure Line of Products - FAQs

ALTIMAX VECTOR X-LANDER

testo 511 Bedienungsanleitung Instruction manual Mode d emploi Manual de instrucciones Manuale di istruzioni Manual de instruções

Outbreaker Sailor Compass / Outbreaker Sailor Compass Medium Model: RA202 / RA282 User Manual TABLE OF CONTENTS

DDR Dive Data Recorder Manual - Rel /12

SAI-340 Pilot Guide Osuna Road NE Suite 711 Albuquerque, NM Rev 3

Heavy Duty Dissolved Oxygen Meter

ALT-1. Introduction. Precision Encoding Altimeter and Vertical speed indicator (VSI) Operating Manual English 1.09

BUBBLER CONTROL SYSTEM

Optical Dissolved Oxygen Meter

Instruction Manual Dräger MSI P7 and MSI P7 plus

TL-3524 USER`S MANUAL

TABLE OF CONTENTS TABLE OF CONTENTS HOW TO USE THIS MANUAL 3 OPERATING THE WATCH CARE & MAINTENANCE 4 WATCH FUNCTIONS 5-6 KEYS AND THEIR FUNCTIONS 7-8

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

F11 OPERATING MANUAL F11 OPERATING MANUAL

Automatic Isokinetic Sampler. ST5 Evo

XP EINS USER MANUAL. Contents: 1.1XP EINS USER S MANUAL

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

Hand-held pressure calibrator with integrated pump Model CPH6600

VISO Manual. LARSEN & BRUSGAARD Mosevej Kirke Hyllinge, Denmark Phone: Fax:

Introduction. Check for the following items before use.

STX 165 Operation. Data Knob Enter Pushbutton. Power/Mode Control. Select Knob Ident Pushbutton. VFR Pushbutton

1811G/H PITOT-STATIC TEST SET


DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

Manual Weighingblock VB2 series and Uniscale

PS-425 Pitot-Static/Air Data Tester

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

I. GENERAL INFORMATION

D-OptoLogger Dissolved Oxygen Logger Operation Manual

MARINER REGATTA YACHTSMAN

Precision pressure sensor Basic version Model CPT6020

AIR FLOW CALIBRATORS Single Sensor Designs

PRODUCT MANUAL. Diver-MOD

Automatic Isokinetic Sampler. ST5 Evo

Pressure transmitter PASCAL Ci4

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

F&J SPECIALTY PRODUCTS The nucleus of quality air monitoring programs

Operation Guide

Technical Information Conducal CLY421

WARNING! Jump Number Main Window Exit Altitude Alti-Meter Mode Deployment Altitude Speed-Meter Mode...

1.0 General Guide WARNING!

Operation Guide 5470

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Aladin ONE (Matrix) User Manual

Technical Data Sheet MF010-O-LC

Warranty The device shall have a 6-year warranty at minimum

DO NOT PRINT THIS PAGE

The ALT-5 is a 2 1/4 (57mm) sunlight readable encoding altimeter and a wide range vertical speed indicator.

WARNING! FAILURE TO FOLLOW ALL WARNINGS, INSTRUCTIONS, AND REQUIRED PROCEDURES MAY RESULT IN SERIOUS INJURY AND DEATH.

Dräger X-act 5000 Automatic Dräger Tube Pump

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

FTC130 Transmitter. Operating Manual

Optical Dissolved Oxygen Meter

Smart Apnea Computer. Instruction Manual

MODEL 6500 Rev. F4 USER'S MANUAL LAVERSAB INC., 505 GILLINGHAM LANE SUGAR LAND TX, (281) FAX: (281)

APA software instruction manual

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

SECTION 6-16 FLIGHT INSTRUMENTS

DG100 Digital Depth Gauge and Timer. Training Module, Rev B

WTSeries C R Y S T A L. Digital Pressure Gauge. Operation Manual. engineering corporation

Operator Quick Guide ORBISPHERE 3654

DTG - LCD Digital Temperature Gauge USER MANUAL

This test shall be carried out on all vehicles equipped with open type traction batteries.

Operation Guide 3259

BI-680 Online Dissolved Oxygen Controller Instruction Manual

Pneumatic high-pressure controller Model CPC7000

PS-525 Pitot-Static/Air Data Tester. OPERATION AND MAINTENANCE MANUAL For Models PS-525 and PS-525A

Owner s Manual Humiport 10/20

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

USER MANUAL. m 2 multi AAD. It could save you... More than you think EN

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

CONSOLE-320 ENGLISH. 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Q2: Which instruments are necessary for monitoring the groundwater level?

DPC-30 DPC-100. Reference Manual

RAM 4021-DPX Operation Manual

Installation and Operation Manual

HI 2314 HI 2315 HI 23151

EC214 EC215 - EC215R Bench Conductivity Meters

Transcription:

DBI version 002 User Manual US version Free Balloon Flight Instrument DBI 002 User Manual issue C7, 2005-05-25 Page 1/29

Safety The manufacturer has designed this instrument to be safe when operated. Do not use this instrument for any other purpose than stated. Operating restrictions This instrument should ONLY be used in ships referred as free balloons carrying open fire or inert gas balloons. On the backside of the instrument is the marking for use onboard manned free balloons only. See photo 3.3 back view. Make sure the battery charge level is enough to ensure instrument operation for entire flight duration. The DBITX1 temperature transmitter and the DBI flight instrument receiver combination is a secondary temperature indicator for envelope top temperature and shall only be used together with a melting fuse temperature flag or equal functional device serving as primary temperature indicator. Abbreviations DBI DigiTool Instruments free balloon flight instrument DBITX1 DigiTool Instruments envelope temperature transmitter LCD Liquid Crystal Display RTCA Requirements & Technical Concepts for Aviation m/s Meter per second ft/min Feet per minute InHg Inch mercury, pressure unit hpa Hecto pascal, pressure unit, equals millibar F Degrees fahrenheit, temperature unit C Degrees celsius, temperature unit V Volt VAC Volt alternating current mm milli meter, length unit In Inch, length unit gram mass unit DBI 002 User Manual issue C7, 2005-05-25 Page 2/29

Table of Contents TABLE OF CONTENTS...3 1. INTRODUCTION...4 1.1. APPROVALS...4 1.2. DESCRIPTION...5 1.3. SPECIFICATION...7 2. INSTALLATION...10 2.1. D-RING CORD ATTACHMENT...10 2.2. VELCRO CORD ATTACHMENT...11 3. OPERATION...12 3.1. DISPLAY VIEW...12 3.2. SIDE VIEWS...14 3.3. BACK VIEWS...15 3.4. IN FLIGHT OPERATING FUNCTIONS...16 3.5. INTERNAL BATTERIES / BATTERY CHARGE...22 3.6. CONFIGURATION...23 4. MAINTENANCE...25 4.1. GENERAL...25 4.2. BATTERY...25 4.3. CLEANING...25 4.4. CALIBRATION CHECK...26 4.5. APPROVED SERVICE AGENTS...27 5. SUPPORT APPARATUS...28 5.1. INTERFACE CABLE AND MAINS CHARGER...28 5.2. DBI PC APPLICATION PROGRAM...29 5.3. DBITX1 ENVELOPE TEMPERATURE TRANSMITTER...29 DBI 002 User Manual issue C7, 2005-05-25 Page 3/29

1. Introduction 1.1. Approvals This device DBI version 002 is approved by the Swedish civil aviation following the documents TSO-C10b with subdocument AS8009 for pressure altimeter systems and TSO-C8d with subdocument AS8016 for vertical velocity instruments. Civil Aviation Authority Swedish Civil Aviation MSU 2/00 German Approval JTSO-C8d AND JTSO-C10b US FAA Approval TSO-C8d AND TSO-C10b Conditions The conditions and tests required for TSO approval of this article are minimum performance standards. It is the responsibility of those desiring to install this article either on or within a specific type or class of aircraft to determine that the aircraft installation conditions are within the TSO standards. If not within the TSO standards, the article may be installed only if further evaluation by the applicant documents an acceptable installation and is approved by the Administrator. DBI 002 User Manual issue C7, 2005-05-25 Page 4/29

1.2. Description The DBI is an integrated flight instrument designed specifically for free balloons operation. Flight data visually presented to the operator are: Altitude, rate of climb and barometric setting air data. Ambient temperature. Balloon envelope temperature. Elapsed flight time. Flight data acoustically presented to the operator are: Rate of climb. Envelope temperature high warning. Altitude high warning. Altitude low warning. Control of the DBI is done via three push buttons: Power On / Off. Barometric setting. Elapsed time timer clear. Altimeter unit toggle (Selectable). Flight recorder start (Selectable). Sound warning reset (Selectable). Altitude sound warning limits setup (Selectable). Flight data recorded during flight are: Barometric setting Static pressure (altitude and rate of climb) Envelope and ambient temperatures Date and time DBI 002 User Manual issue C7, 2005-05-25 Page 5/29

In non flight, an interface connects the DBI to standard PC computers : Configuration Internal battery charge. Flight recorder data upload. DBI 002 User Manual issue C7, 2005-05-25 Page 6/29

1.3. Specification Altimeter Range feet x 1000 Total error +/- feet at 25 C / 77 F Total error +/- feet at -30 C / -22 F Total error +/- feet at 70 C / 158 F -1 to 6 30 52 43 6 to 8 40 70 58 8 to 10 45 78 65 10 to 12 50 87 72 12 to 14 55 96 79 14 to 16 60 105 87 16 to 18 65 113 94 18 to 20 70 122 101 20 to 22 75 131 108 22 to 25 85 148 123 25 to 30 100 175 145 30 to 35 120 210 174 35 to 40 135 236 195 Rate of climb (variometer) Absolute error Scale error Time constant (configurable) Barometric setting Total error (900 to 1200 hpa) Total error (26.6 to 36.5 inhg) < 0.1 m/s, 20 ft/min < 0.15 % of reading 1.6 to 6.0 seconds < 0.2 meter < 1 ft DBI 002 User Manual issue C7, 2005-05-25 Page 7/29

Ambient thermometer Range C Total error +/- C F C F -50 to -25-58 to -13 3 6-25 to 0-13 to 32 2 4 0 to 50 32 to 122 1 2 50 to 75 122 to 167 2 4 75 to 100 167 to 212 3 6 100 to 125 212 to 257 4 7 Envelope thermometer Range C Total error +/- C F C F -25 to 0-13 to 32 4 7 0 to 50 32 to 122 3 6 50 to 75 122 to 167 2 4 75 to 125 167 to 257 1 2 125 to 150 257 to 302 2 4 150 to 175 302 to 347 3 6 175 to 200 347 to 392 4 7 Physical dimensions Item Value metric Value Imperial Length 131 mm 5.16 inch Height 110 mm 4.33 inch Depth 31 mm 1.22 inch Weight 480 gram 17 ounce Weight 480 gram 1.06 pound DBI 002 User Manual issue C7, 2005-05-25 Page 8/29

Environmental ratings Item Limitations Vibration RTCA/DO-160C section 8 Category M Shock RTCA/DO-160C section 7 Radio - Frequency Susceptibility RTCA/DO-160C, (Change No 3) section 20.2 category Y Radio - Frequency Emission RTCA/DO-160C section 21.2 category Z Explosion RTCA/DO-160C section 9 category X Humidity RTCA/DO-160C section 6 category A Water RTCA/DO-160C section 10 category W Sand and Dust RTCA/DO-160C section 12 category X Salt Spray RTCA/DO-160C section 14 category X Fungus Resistance RTCA/DO-160C section 13 category X Magnetic Effect RTCA/DO-160C section 15.3 category A Operating temperature and RTCA/DO-160C section 4, ambient pressure category paragraph 4.3, Section C4 Ambient Pressure storage 0 to 2000 hpa / 0 to 59 inhg Temperature High Operating 70 C / 158 F Temperature Low Operating -30 C / -22 F Temperature High Storage 100 C / 212 F Temperature Low Storage -55 C / -67 F DBI 002 User Manual issue C7, 2005-05-25 Page 9/29

2. Installation 2.1. D-ring cord attachment Use the cord to strap on a suitable item, for example a propane tank or the overhead frame support. Look the cord using the D-rings as shown below. D rings Cord DBI 002 User Manual issue C7, 2005-05-25 Page 10/29

2.2. Velcro cord attachment Use the cord to strap on a suitable item, for example a propane tank or the overhead frame support. Look the double sided velcro cord by tightly pressing opposite cord surfaces together. Double sided velcro cord DBI 002 User Manual issue C7, 2005-05-25 Page 11/29

3. Operation 3.1. Display view 6 7 8 9 10 11 1 2 4 3 5 DBI 002 User Manual issue C7, 2005-05-25 Page 12/29

Display view list Control push buttons function # Function Action 1 Decrement baro setting Click 2 Increment baro setting Click 1 + 2 Power OFF instrument Hold 2 seconds 3 Power ON instrument Click 3 Clear flight time Hold 2 seconds 3 Start Flight recorder (Selectable) Hold 2 seconds 3 Sound warning reset (Selectable) Click 3 Toggle altimeter unit (Selectable) Double click 2 + 3 Alt warning limits setup (Selectable) Hold 2 seconds Display items # Item Unit 4 QNH setting hpa or InHg 5 Battery status 5 to 0 segments 6 Analog rate of climb Scale fixed 7 Digital rate of climb ft/min or m/s 8 Envelope temperature C or F 9 Ambient temperature 10 Altimeter meter or feet 11 Flight time hh:mm DBI 002 User Manual issue C7, 2005-05-25 Page 13/29

3.2. Side views Right hand side Interface connector Ambient temperature sensor Left hand side Battery screw cap Negative facing OUT Acoustic rate of climb aperture DBI 002 User Manual issue C7, 2005-05-25 Page 14/29

3.3. Back views Type label Operating restrictions and FCC ID label DBI 002 User Manual issue C7, 2005-05-25 Page 15/29

3.4. In flight operating functions Power On / Off The DBI is powered ON by pressing the C/Time push button. This button is also marked ON. The DBI is powered OFF by pressing the two BAR buttons simultaneously for 2 seconds. These two buttons are also marked OFF. Auto power off enabled: The DBI powers off automatically when acquired static pressure has changed less than 0.5 hpa (4 meters altitude change at 1013 hpa) during 30 seconds during a 30 minutes time interval. Prior to the auto power off, the altitude display digits shows OFF. Altimeter Altitude is displayed with 5 digits. Displayed Metric range is -9999 to 99999 meter. 1 meter resolution. Displayed Imperial range is -9999 to 99999 feet. 1 foot resolution. Unit static toggle enabled: Double clicking the C/Time push button toggles unit, [m or ft]. Unit timeout toggle enabled: Double clicking the C/Time push button toggles unit, [m or ft] for 2 seconds. DBI 002 User Manual issue C7, 2005-05-25 Page 16/29

Rate of climb (variometer) Rate of climb is displayed analog and digital. Response time can be configured between 1.2 to 6.0 seconds (fast to slow). Analog rate of climb (variometer) An analog scale displays rate of climb. Zero indication is at 9 o clock. Climb is indicated clockwise from 9 o clock. Descend is indicated counter clockwise from 9 o clock. Range is fixed at 5 meters per second,1000 feet per minute). This range is fixed marked on display. Rate of climb or descend over 5 meters per second is indicated by a blinking analog variometer display. Digital rate of climb (variometer) Rate of climb / descend is displayed with digits. NOTE: No sign is displayed. Metric range is 0 to 99.9 meter per second with one decimal place. Imperial range is 0 to 9900 feet per minute in 10:th increments. Barometric setting Metric range is 900 to 1100 hpa with one decimal place. Adjustment fraction is 100 hpa (1mbar). Imperial range is 26.58 to 32.48 InHg with two decimal places. Adjustment fraction is 0.02 InHg. DBI 002 User Manual issue C7, 2005-05-25 Page 17/29

Acoustic rate of climb (variometer) Sound signature is separately configured for climb and descend. Configurable signature: On/Off, Activation threshold, sound repetition interval scale factor. Acoustic altitude high warning Warning signal is activated on climb transition passing configured altitude high warning limit. Warning signal is deactivated below altitude high warning limit. Warning signal is deactivated by pressing the C/Time pushbutton. Acoustic altitude low warning Warning signal is activated on descend transition passing configured altitude low warning limit. Warning signal is deactivated above altitude low warning limit. Warning signal is deactivated by pressing the C/Time pushbutton. Acoustic envelope temperature warning Warning signal is activated when exceeding configured temperature high warning limit. Warning signal is deactivated below temperature high warning limit. Warning signal is deactivated by pressing the C/Time pushbutton. Flight time timer Elapsed time is displayed. Range is 00:00 to 99:59 [hour : min]. Timer is CLEARED on power up. Timer is CLEARED by pressing the C/Time pushbutton for more than 2 seconds. DBI 002 User Manual issue C7, 2005-05-25 Page 18/29

Ambient thermometer Ambient temperature is displayed with 3 digits. Imperial range is -60 to 257 F. Metric range is -50 to 125 C. Envelope thermometer The DBI receives envelope temperature from the DBITX1 temperature transmitter (normally located at the top of the envelope). Envelope temperature is displayed with 3 digits. Imperial range is -13 to 392 F. Metric range is -25 to 200 C. Loss of data reception is displayed as ---. The DBI is configured with identification codes unique for each DBITX1. The DBI can be configured with up to 8 codes. NOTE: Only one DBITX1 shall be active during flight. Battery monitor Battery charge status is displayed with a battery symbol containing 0 to 5 segments. Segments Continuing operation [hours] 5 50 4 40 3 30 2 20 1 10 0 >1 DBI 002 User Manual issue C7, 2005-05-25 Page 19/29

Flight data recorder During power on, flight data is recorded. Storage capacity is up to 170 hours and older data is overwritten. Start mode is configurable. Mode Off Power on Altitude takeoff Altitude takeoff, clear lap Start/Restart at manual lap clear Flight recorder start modes Description Disabled. Starts at DBI power ON. Starts at 1 hpa ambient static pressure decrease (approx 8 meters). Starts at 1 hpa ambient static pressure decrease (approx 8 meters), also clears elapsed flight timer. Starts at manual elapsed flight timer clear. Flight recorder data Recorded raw data Derived data Barometric setting Acquired static pressure Altitude Ambient temperature Ambient temperature Envelope temperature Envelope temperature UTC time UTC time and elapsed time DBI 002 User Manual issue C7, 2005-05-25 Page 20/29

Altitude sound warning limits setup The altitude sound warning limits can be set up by the configuration procedure (see 3.6) or direct on the DBI. To use the direct set up method, it has to be enabled by the configuration procedure (see 3.6). Direct set up method enabled: Press C/Time and + buttons simultaneously to enter set up mode Press + or button to: (ALT display) Press C/Time button to walk through set up states. (QNH display) Unit ALtH ALtL ConF + Select meter - Select feet + Increase ceiling - Decrease ceiling + Increase floor - Decrease floor + Enable and return - Disable and return DBI 002 User Manual issue C7, 2005-05-25 Page 21/29

3.5. Internal batteries / battery charge Internal batteries The DBI is powered by two rechargeable NiMH AAA batteries. These can be replaced via the battery access screw cap. Charge The DBI is charged by connecting the DBI interface cable and the mains (230/110 VAC) charger. The charge process is fully automatic and takes approximately one hour from fully discharged condition. This is indicated by fast moving battery indicator. Completed charge phase is indicated by slow moving battery indicator. Operational recommendations See paragraph 4.2 Maintenance - batteries. DBI 002 User Manual issue C7, 2005-05-25 Page 22/29

3.6. Configuration Configuration of the DBI shall be done only in non flight mode. This is done by connecting the DBI to a standard PC type computers serial port with the DBI interface cable. The PC shall execute the DBI configuration program. Air data unit selection The DBI displays selectable units for flight data. Programmable air data units are: Altitude unit meter or feet. Altitude unit toggle mode, off or static or timeout. Rate of climb meter per second or feet per minute. Barometric setting unit hecto pascal or inch mercury. Temperature unit celsius or fahrenheit. NOTE! Flight data units is displayed during DBI flight mode. Unit selection shall be fully understood by the operator prior to flight usage. Acoustic rate of climb Acoustic indication threshold and signature. Acoustic high and low altitude warning Acoustic indication thresholds and signature. Acoustic envelope temperature warning Acoustic indication threshold and signature. Flight recorder Date and time. Flight recorder start mode. DBI 002 User Manual issue C7, 2005-05-25 Page 23/29

DBITX1 envelope temperature transmitter identification The DBI is programmed with a 5 digit identification code labeled on the DBITX1 envelope temperature transmitter used. The DBI stores maximum 8 different codes. Automatic power off The automatic power off function enabled or disabled. Flight recorder start mode The flight recorder start mode (1 of 4) selected or disabled. Altimeter unit toggle Altitude unit toggling mode selected or disabled Alt warning limits setup Direct alt warning limit setup enabled or disabled. DBI 002 User Manual issue C7, 2005-05-25 Page 24/29

4. Maintenance 4.1. General The DBI contains NO internal serviceable parts. If subject to malfunction or other damage an approved service agent shall be used. Operator maintenance is limited to cleaning and battery inspection. 4.2. Battery Inspect screw cap, battery support tube and inner contact for contamination. If contaminated, clean with soft cloth. Replace batteries if poor endurance is observed. Type is NiMH size AAA. Always replace both. Remove batteries prior to DBI long time storage. 4.3. Cleaning Use water and kitchen dish detergent to clean the DBI, dry with soft cloth. Be cautious not to scratch the transparent polycarbonate front cover with hard tools. DBI 002 User Manual issue C7, 2005-05-25 Page 25/29

4.4. Calibration check General The DBI shall be checked for static pressure acquisition tolerances every 24 month or according to national regulations. This should be done ONLY by approved organizations to conform with national regulations. Approved service station can obtain drawing and instructions for calibration from below stated service agents. Control setup Place the DBI in a pressure sealed chamber connected to a pressure calibrator. The chamber shall have a viewing window enabling reading of DBI display. Control procedure Set the DBI barometric setting to 1013 hpa. Subject the DBI to pressure altitudes listed in paragraph 1.3 Specification - altimeter column 1 by means of a pressure calibrator. Compare displayed altitude reading to be within column 2 max error tolerances. Recalibration procedure The DBI is recalibrated for offset error by using the DBI application program together with above control procedure data. This functionality shall ONLY be used by an national approved service station. DBI 002 User Manual issue C7, 2005-05-25 Page 26/29

4.5. Approved service agents Name Location Contact DigiTool AB Sweden Tel +46 8 343410 Email info@digitool.se Or any by national CAA listed Worldwide Check with your C.A.A. DBI 002 User Manual issue C7, 2005-05-25 Page 27/29

5. Support apparatus 5.1. Interface cable and mains charger The PC interface cable connects the DBI to a PCs serial port via a 9 pin DSUB connector and to a mains charger. The mains charger input voltage range is market on the charger. PC computer connector Mains Charger DBI connector DBI 002 User Manual issue C7, 2005-05-25 Page 28/29

5.2. DBI PC application program The application program enables configuration off and flight recorder access to the DBI. Functionality is described when running the application. To use the application program, follow these steps: Install the application Connect the DBI to the PC:s serial port via the interface cable. Power on the DBI. Start the application 5.3. DBITX1 envelope temperature transmitter The DBITX1 is described in DBITX1 User Manual. DBI 002 User Manual issue C7, 2005-05-25 Page 29/29