INSTALLATION AND OPERATING INSTRUCTIONS BIG TEX VENTED GAS LOGS

ROBERT H. PETERSON CO. AUTOMATIC REMOTE LIGHTING SAFETY PILOT SYSTEM WITH VARIABLE FLAME-HEIGHT REMOTE FOR NATURAL OR PROPANE GAS. Model APK-17(M)(P)

WARNING: FOR OUTDOOR USE ONLY

Robert H. Peterson Company

ROBERT H. PETERSON CO. EPIC BURNER GAS LOG SET

G45-2 STAINLESS STEEL BURNER FOR INDOOR OR OUTDOOR USE

AC POWERED ELECTRONIC PILOT KIT

OCBE-34-01M (P) OUTDOOR CAMPFYRE ELECTRONIC SYSTEM WITH REMOTE CONTROL

ROBERT H. PETERSON CO.

EPIC BURNER GAS LOG SET

Installation and Operation Instructions

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

USER S INFORMATION MANUAL

OWNER'S MANUAL WARNING WARNING WARNING WARNING. Factory No.: HYFP Item No.: 67668ST

Standard Gas Countertop Griddle

Thanks for shopping with Improvements! Monterey Propane Fire Column Item #574852

Installation Instructions WARNING: WARNING: WARNING: LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS

Gas Countertop Hot Plates

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

CASUAL FIRESIDE A HIGHER STANDARD IN QUALITY AND APPEARANCE - SAFE AND BEAUTIFUL OUTDOOR FIRE PIT FOR PROPANE AND *NATURAL GAS

JACKSON GRILLS PATIO FIRE

INSTALLATION AND OPERATION INSTRUCTIONS

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

GAS FRYER Instruction Manual Model #5099NS

Gas Fired Residential Heating Boilers

CastCreations PRODUCT DESCRIPTION. Redwood Stump Fire Pit Item #: C1002. CastCreations Ph: Aurora, Utah


Fire's Edge. Fire Pit or Fire Pit Insert Model 100A-M (Manual Operation) OWNER S MANUAL / OPERATING AND MAINTENANCE INSTRUCTIONS

UNIVERSAL GAS FRYER Instruction Manual Model #8065NS

- Do not store gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

/2004 US/CA

OWNER S MANUAL 28" GRIDDLE COOKING STATION

OPERATING INSTRUCTIONS

Natural Gas High-Altitude Conversion Kit For Installations in the United States (2,001 10,000 Feet)

INSTALLATION GUIDE Gas Rangetops

Operating and Maintenance Instructions

INSTALLATION, OPERATION, SERVICE & PARTS MANUAL FOR STOCK POT RANGE MODELS VSP100, VSP200 & VSP300

Operator: Save these instructions for future use!

OWNERS MANUAL WARNING WARNING WARNING WARNING WARNING WARNING DANGER. Series No.: Style No.: READ BEFORE USE!

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

WARNING: Installation Instructions. Natural Gas High Altitude Conversion Kit United States Installations Only

Natural Gas Conversion Kit

Propane Conversion Kit Instruction

HOT SHOT OPERATING INSTRUCTIONS AND OWNER S MANUAL. Model SPC-500. (Propane Torch)

Vianti Falls Fire Burner Kit (HBF16) & Propane Adapter Kit (HBF16AK) (These instructions are intended for use with a 20 lb.

Operator: Save these instructions for future use!

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

Toll Free: (877) Fax: (877) TK Torch Match Lit WARNING: FOR OUTDOOR USE ONLY

INSTALLATION & OPERATION MANUAL FOR Teppan-Yaki Griddles

INSTALLATION & OPERATION MANUAL FOR Stockpot Range

Gas Countertop Griddle

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

36H SERIES Combination Gas Valve

ACCESSORIES MAY BE PURCHASED SEPARATELY.

Congratulations! Hand Held Torch. Warranty Policy PARTS

Operator Manual Gas Griddle / Cheesemelter

Installation Instructions and Owner s Manual

INSTALLATION INSTRUCTIONS

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Operator: Save these instructions for future use!

Topanga Propane Fire Table Owner s Manual Small Round Style #

Installation Instructions

USER MANUAL Wok Range

OCBE-44 series ROUND OUTDOOR CAMPFYRE CONTROL SYSTEM

Owner s Manual for Assembly, Operating & Maintenance of

TK Torch Match Lit WARNING: FOR OUTDOOR USE ONLY

ASSEMBLY & OPERATING INSTRUCTIONS

Propane Conversion Kit Instruction

FPK Spark Ignition Safety Manual Installation & Operation Instructions. This Product is for use with Natural Gas Only.

Propane Conversion Kit Instruction

Hearth Products Controls Co. 706 Congress Park Dr. Dayton, OH FPK Spark Ignition Safety Manual Installation & Operation Instructions

MATCH LIT FIRE PIT MANUAL INSTALLATION & OPERATION INSTRUCTION

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

FIREPLACE INSTALLATION

127 / 460 Air Mixer and all FPSLPK Kits Installation & Operation Instructions

Natural Gas to L.P. Gas Conversion Kit

Natural Gas to L.P. Gas Conversion Kit

FPLP CONVERSION KIT- Small Tank Fire Pit LP Conversion Kit for Manual Ignition Pits

Owner s Manual Installation and Operation

USE AND ASSEMBLY INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS

LITTLE MAX MODEL 50G 50,000 BTU PROPANE TORCH

RE: PROPANE SYSTEM & REGULATOR TESTING/INSPECTION PROCEDURE

Installation Instructions For Natural Gas Conversion

Match Lit Fire Pit Insert MLFPK Series Installation & Operation Instructions

MODELS. Premium Weave Rectangular Woven Table

Propane Conversion Kit Instructions

1 Square = Foot/Feet Revision G 1/18/2013 Titan Controls

installation instructions

WARNING: Gas Conversion Kit Instructions Applies to: Model UDAP, UDAS, UDBP, and UDBS Unit Heaters. General and Warnings FOR YOUR SAFETY

INSTRUCTION MANUAL. Gas Salamander

Installation Instructions

GAS CONVERSION KIT Installation Instructions Range/Rangetop

The conversion of new certified central heating gas appliances must conform to directions outlined in this instruction.

Owner's Manual and Instructions

FPLP CONVERSION KIT- Small Tank Fire Pit LP Conversion Kit for Manual Ignition Pits

Transcription:

INSTALLER! PLEASE LEAVE WITH HOMEOWNER INSTALLATION AND OPERATING INSTRUCTIONS Please Note: It is important that you read instructions before installing or operating this appliance GENERAL INFORMATION This appliance is to be burned only in an approved woodburning Fireplace with adequate chimney draft. When burning, the chimney damper must be FULLY OPEN. This appliance must be installed in a fireplace which operates properly when wood fires are burned. For best results, natural gas pressure must be 7 to 10-1/2 water column. If used with glass fireplace doors, burn with doors in open position. Do not burn wood or other items with this appliance. IMPORTANT INFORMATION FOR YOUR SAFETY If you smell gas: 1. Open Windows. 2. Don t touch electrical switches. 3. Extinguish any open flame. 4. Immediately call your gas supplier. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. CHECK TO BE SURE APPLIANCE IS FOR PROPER GAS TYPE. This appliance is designed for use with Natural Gas unless clearly labeled for Propane (LP). Never use Propane Gas in an appliance designed for Natural Gas or Natural Gas in an appliance designed for use of Propane Gas. The installation, including provisions for combustion and ventilation air, must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1-1988 and NFPA54-1988. The appliance and its individual shutoff valve must be disconnected from the gas supply piping system when testing at test pressures in excess of 1/2 psig. The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of gas-supply system at test pressures equal to or less than 1/2 psig. This is accomplished by closing the gas supply line valve, which is required by NFPA 54, section 5.54 The minimum inlet gas supply pressure for the purpose of input adjustment is 7 WC for Natural Gas and 11 WC for Propane Gas. The maximum inlet gas supply pressure for this burner is 10.5 for Natural Gas and 13 for Propane Gas. MANUFACTURED BY: 4301 WESTGROVE DRIVE ADDISON, TX 75001

ALPINE LINEAR BURNER SPECIFICATIONS MODEL # MINIMUM FIREBOX BTU/HR WIDTH AT 7 DEEP FROM FRONT FIREBOX ALB24NAT 26 22,500 ALB30NAT 32 25,250 ALB36NAT 38 34,000 ALB42NAT 44 39,600 ALB48NAT 50 44,352 ALB60NAT 62 56,175 ALB72NAT 74 68,000 ALB24LP 26 20,500 ALB30LP 32 31,000 ALB36LP 38 37,750 ALB42LP 44 43,800 ALB48LP 50 49,000 ALB60LP 62 62,250 ALB72LP 74 75,500 COMPONENTS PARTS ITEM 1. Alpine Linear Burner 2. Silica Sand 3. Vermiculite 4. Black Volcanic Cinders 6 1 Width same as Model Unit Dimensions 6 5. Glowing Embers 6. Gas Connector 7. Damper Clamp *The gas fittings supplied are for what the factory considers a normal installation. Some installations may require a longer connector tube or other fittings available in most hardware stores.

TO INSTALL LINEAR BURNER: 1. Attach damper clamp to fireplace damper to prevent damper from being fully closed. 2. Position burner assembly into fireplace and position in center of floor. 3. Attach Gas connector to gas supply line and connect to burner assembly. Use soapy water to check connections for leaks. (Figure 3-1) 4. Pour silica sand into burner pan completely covering pipe in pan. For LP Gas models, use vermiculite instead of sand. (Figure 3-2) NOTE! Optional decorative fireglass can be susbstituted for silica sand or vermiculite (LP) for a more contemporary design if desired (Figure 3-5). Figure 3-1 Figure 3-2 Figure 3-3 Figure 3-4 5. Place glowing ember material over sand (Vermiculite LP). (Figure 3-3) Note: Not used if optional decorative fireglass is used. Spread the black volcanic cinders in front of and on sides of Linear Burner (Figure 3-4) NOTE! Optional Decorative Fireglass can also be used in place of black volcanic cinders. (Figure 3-5) Figure 3-5 DAMPER MUST BE IN FULL OPEN POSITION BEFORE LIGHTING. Lighting instructions for Alpine Linear Burners with a millivolt, spark to pilot, or S-model Skytech Hi/Lo valve located on subsequent pages of this manual. YOU ARE NOW READY TO LIGHT THE BURNER BY TURNING THE FIREPLACE GAS VALVE ON AND USING A LONG MATCH OR BUTANE LOG LIGHTER. LIGHT THE BURNER BY POSITIONING MATCH OR LIGHTER JUST OVER BURNER WHILE TURNING ON THE GAS VALVE. DURING THE FIRST FEW HOURS OF OPERATION, AN OCASSIONAL POPPING SOUND CAN BE HEARD AS A RESULT OF THE METAL EXPANDING FROM HEAT. THIS WILL STOP AFTER A SHORT PERIOD OF TIME.

LIGHTING INSTRUCTIONS FOR S-MODEL SKYTECH REMOTE HI-LO MOTOR MODELS Pilot Burner Location Decorative Front Screw Remote Control Connector Control Knob FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE A. The Golden Blount appliance has a pilot which must be lit by hand. When lighting the pilot, follow these instructions exactly. B. Before Lighting, smell all around the area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switch, do not use any phone in your building. Immediately call your gas supplier from your neighbor s phone. Follow the gas supplier s instructions. If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn gas control knob. Never use tools. If the knob will not push in or turn by hand, don t try to repair it. Call a qualified service technician. Force or attempted repair may result in fire or explosion. D. Do not use the appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance set and to replace any part of the control system and any gas control system and any gas control which has been under water. E. FIREPLACE DAMPER MUST BE FULLY OPENED. 1. Stop! First read the safety information at the left. 2. Remove two screws from sides of burner and take off decorative front to access control valve. 3. Turn the control to the OFF position. To do this, you must turn the knob clockwise to the PILOT position and then press in and continue turning clockwise to the OFF position. 4. WAIT FIVE (5) MINUTES TO CLEAR OUT ANY GAS. If you then smell gas, STOP! Follow step B in the safety information at the left. If you don t smell gas, go to the next step. 5. To put the control in the pilot position, turn the control knob counter-clockwise to the PILOT position. 6. To light the pilot, depress the control knob and light the pilot using a long match or extended butane lighter. The control knob should be held IN for 1 minute. 7. Release the control knob. The pilot should remain lit after releasing. 8. Turn the control knob counter-clockwise to the ON position. 9. Connect RCAF-1031 Remote control receiver to connector on control valve and position receiver behind burner assembly on floor of fireplace. 10. Replace decorative front and follow operation instructions supplied with RCAF-1031 Remote Control. To Turn OFF Gas To Appliance 1. Turn off switch or remote. 2. Remove Decorative Front 3. Turn control knob clockwise to PILOT 4. Depress control knob slightly and turn clockwise to OFF

LIGHTING INSTRUCTIONS FOR MILLIVOLT CONTROL VALVE MODELS Gas Control Knob Decorative Front Screw Pilot Burner Location On/Off Switch FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE A. The Golden Blount appliance has a pilot which must be lit by hand. When lighting the pilot, follow these instructions exactly. B. Before Lighting, smell all around the area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switch, do not use any phone in your building. Immediately call your gas supplier from your neighbor s phone. Follow the gas supplier s instructions. If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn gas control knob. Never use tools. If the knob will not push in or turn by hand, don t try to repair it. Call a qualified service technician. Force or attempted repair may result in fire or explosion. D. Do not use the appliance if any part has been under water. Immediately call a qualified service technician to inspect the gas log set and to replace any part of the control system and any gas control system and any gas control which has been under water. E. FIREPLACE DAMPER MUST BE FULLY OPENED. 1. Stop! First read the safety information at the left. 2. Remove two screws from sides of burner and take off decorative front to access control valve. 3. Turn the control to the OFF position. To do this, you must turn the knob clockwise to the PILOT position and then press in and continue turning clockwise to the OFF position. 4. WAIT FIVE (5) MINUTES TO CLEAR OUT ANY GAS. If you then smell gas, STOP! Follow step B in the safety information at the left. If you don t smell gas, go to the next step. 5. To put the control in the pilot position, turn the control knob counter-clockwise to the PILOT position. 6. To light the pilot, depress the control knob and light the pilot using a long match or extended butane lighter. The control knob should be held IN for 1 minute. 7. Release the control knob. The pilot should remain lit after releasing. 8. Turn the control knob counter-clockwise to the ON position. 9. Replace decorative front and turn on switch, wall switch or on/off remote connected to wire leads tagged For Remote or Wall Switch To Turn OFF Gas To Appliance 1. Turn off switch or remote. 2. Remove Decorative Front 3. Turn control knob clockwise to PILOT 4. Depress control knob slightly and turn clockwise to OFF

LIGHTING INSTRUCTIONS FOR STP SPARK-TO-PILOT CONTROL VALVE MODELS Pilot Burner Location Decorative Front Screw On/Off Switch Gas Control Valve Battery Pack Control Module FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE A. The Golden Blount appliance has a pilot which must be lit by hand. When lighting the pilot, follow these instructions exactly. B. Before Lighting, smell all around the area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switch, do not use any phone in your building. Immediately call your gas supplier from your neighbor s phone. Follow the gas supplier s instructions. If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn gas control knob. Never use tools. If the knob will not push in or turn by hand, don t try to repair it. Call a qualified service technician. Force or attempted repair may result in fire or explosion. D. Do not use the appliance if any part has been under water. Immediately call a qualified service technician to inspect the gas log set and to replace any part of the control system and any gas control system and any gas control which has been under water. 1. Stop! First read the safety information at the left. 2. Remove two screws from sides of burner and take off decorative front to access control compartment. 3. Install two D batteries into Battery Pack located in control compartment. 4. Replace Decorative Front 5. Turn on switch, wall switch or ON/OFF remote connected to wire leads tagged For Remote or Wall Switch To Turn OFF Gas To Appliance 1. Turn off switch or remote. LIMITED WARRANTY Alpine Linear Burners are warranted against defective materials and/or workmanship for five years from date of purchase. Safety Pilot Assemblies, Gas Control Valves, Flame Sensors and other ignition components are covered for one year. This warranty does not cover parts subjected to misuse, abuse, improper handling or improper installation. The GB warranty specifically excludes any liability for indirect, incidental or consequential damage to property. Defective parts should be returned to your dealer or to the factory prepaid with a copy of your sales receipt. Defective parts will be repaired or replaced at the factory s option and returned to you prepaid. GOLDEN BLOUNT 4301 WESTGROVE DRIVE ADDISON, TX 75001 E. FIREPLACE DAMPER MUST BE FULLY OPENED.