BUILDING REGULATION AND THERMAL COMFORT: THE OPENING TYPOLOGY INFLUENCE ON NATURAL COOLING INSIDE OFFICE BUILDINGS IN MACEIÓ.

Similar documents
Analogical Visualization of Natural Ventilation in Buildings due to Wind Action

AN IMPROVED CROSS VENTILATION MODEL IN WINDY REGIONS

NUMERICAL INVESTIGATION OF THE FLOW BEHAVIOUR IN A MODERN TRAFFIC TUNNEL IN CASE OF FIRE INCIDENT

FLOW CONSIDERATIONS IN INDUSTRIAL SILENCER DESIGN

Evaluation of the Relationship between Natural Ventilation and the Grouping of Five Year Old Children in a Kindergarten Classroom of Medellin

PLEA th Conference, Opportunities, Limits & Needs Towards an environmentally responsible architecture Lima, Perú 7-9 November 2012

Natural Ventilation Applications in Hot-humid Climate: A Preliminary Design for the College of Design at NTUST

Development of Biomimicry Wind Louver Surface Design

Cooling performance of Persian wind towers

Effect of airflow direction on human perception of draught

Influence of the external dynamic wind pressure on the ventilation of double facades

FUNNELLING WINDOW: EXPERIMENTAL STUDY OF VENTILATION PERFORMANCE

A Study on the Effects of Wind on the Drift Loss of a Cooling Tower

Wind tunnel acoustic testing of wind generated noise on building facade elements

INTERACTION BETWEEN WIND-DRIVEN AND BUOYANCY-DRIVEN NATURAL VENTILATION Bo Wang, Foster and Partners, London, UK

CFD Study of Solid Wind Tunnel Wall Effects on Wing Characteristics

The Usage of Propeller Tunnels For Higher Efficiency and Lower Vibration. M. Burak Şamşul

AIRFLOW AND TEMPERATURE FIELD CALCULATIONS FOR WINTER SPORTS FACILITIES

OPTIMIZATION OF SINGLE STAGE AXIAL FLOW COMPRESSOR FOR DIFFERENT ROTATIONAL SPEED USING CFD

ANALYSIS OF HEAT TRANSFER THROUGH EXTERNAL FINS USING CFD TOOL

Full scale measurements and simulations of the wind speed in the close proximity of the building skin

AIRFLOW GENERATION IN A TUNNEL USING A SACCARDO VENTILATION SYSTEM AGAINST THE BUOYANCY EFFECT PRODUCED BY A FIRE

NUMERICAL SIMULATION OF STATIC INTERFERENCE EFFECTS FOR SINGLE BUILDINGS GROUP

AERODYNAMIC FEATURES AS AUXILIARY ARCHITECTURE

Influence of the Number of Blades on the Mechanical Power Curve of Wind Turbines

The Classroom Environment

Aerodynamic Measures for the Vortex-induced Vibration of π-shape Composite Girder in Cable-stayed Bridge

CFD Analysis of Giromill Type Vertical Axis Wind Turbine

REVIEW Effects of Side Vents and Span Numbers on Wind-Induced Natural Ventilation of a Gothic Multi-Span Greenhouse

Techniques to achieve wind comfort & wind loads on buildings and appurtenances

Návrh vratného kanálu u dvoustupňového kompresoru Return channel design of the two stage compressor

Effects of wind incidence angle on wind pressure distribution on square plan tall buildings

THEORETICAL EVALUATION OF FLOW THROUGH CENTRIFUGAL COMPRESSOR STAGE

Fire safety of staircases in multi-storey buildings The results of measurements in Buildings and Simulations

Quantification of the Effects of Turbulence in Wind on the Flutter Stability of Suspension Bridges

CROSS CONTAMINATION OF IN-SUITE MURB VENTILATION SYSTEMS

Influence of rounding corners on unsteady flow and heat transfer around a square cylinder

AIRFOIL PROFILE OPTIMIZATION OF AN AIR SUCTION EQUIPMENT WITH AN AIR DUCT

PRESSURE FLUCTUATIONS ACTING ON A TAPERED TALL BUILDING

AN INVESTIGATION OF LONGITUDINAL VENTILATION FOR SHORT ROAD TUNNELS WITH HIGH FIRE HRR

Free Surface Flow Simulation with ACUSIM in the Water Industry

A computational study on structural barrier to vertical spread of window spill plume along building exterior façade under external wind

Akasison Flow phenomena of a siphonic roof outlet

Performance Evaluation of Four-Sided Square Wind Catchers with Different Geometries by Numerical Method

Lecture 11 Natural Ventilation (Passive Cooling)

The Influence of Community Planning on Urban Thermal Environment

A Research on the Airflow Efficiency Analysis according to the Variation of the Geometry Tolerance of the Sirocco Fan Cut-off for Air Purifier

Wind Flow Model of Area Surrounding the Case Western Reserve University Wind Turbine

CFD Modeling of Thermal Manikin Heat Loss in a Comfort Evaluation Benchmark Test

Basis of Structural Design

LONGITUDINAL AIR VELOCITY CONTROL IN A ROAD TUNNEL DURING A FIRE EVENT

Ventilation of Small Multispan Greenhouse in Relation to the Window Openings Calculated with CFD

Surrounding buildings and wind pressure distribution on a high rise building

Research on Small Wind Power System Based on H-type Vertical Wind Turbine Rong-Qiang GUAN a, Jing YU b

EMPIRICAL EVALUATION OF THREE WIND ANALYSIS TOOLS FOR CONCEPT DESIGN OF AN URBAN WIND SHELTER

Aerodynamic Performance of Trains with Different Longitudinal Section Lines under Crosswind

A COMPARATIVE STUDY OF MIX FLOW PUMP IMPELLER CFD ANALYSIS AND EXPERIMENTAL DATA OF SUBMERSIBLE PUMP

A new modern Design of four-sided Windcatcher for Natural Ventilation in Residential Building in Saudi Arabia

Numerical and Experimental Investigation of the Possibility of Forming the Wake Flow of Large Ships by Using the Vortex Generators

Understanding Centrifugal Compressor Capacity Controls:

Currents measurements in the coast of Montevideo, Uruguay

International Journal of Technical Research and Applications e-issn: , Volume 4, Issue 3 (May-June, 2016), PP.

Ciência e Natura ISSN: Universidade Federal de Santa Maria Brasil

IGUMA - IGU Design Limitations

Fig 2.17: Topographic model: snow-free area (Snow boundary = red) Contour interval of 1 m.

Analysis of pressure losses in the diffuser of a control valve

Ermenek Dam and HEPP: Spillway Test & 3D Numeric-Hydraulic Analysis of Jet Collision

Investigation on 3-D Wing of commercial Aeroplane with Aerofoil NACA 2415 Using CFD Fluent

M. Mikkonen.

Citation Journal of Thermal Science, 18(4),

Computational Analysis of Cavity Effect over Aircraft Wing

Wind Flow Validation Summary

DUE TO EXTERNAL FORCES

Effect of High-Lift Devices on Aircraft Wing

AIRFLOW AROUND CONIC TENSILE MEMBRANE STRUCTURES

An Impeller Blade Analysis of Centrifugal Gas Compressor Using CFD

Investigation of Suction Process of Scroll Compressors

CALMO

Aspects of Using CFD for Wind Comfort Modeling Around Tall Buildings

Outline. Wind Turbine Siting. Roughness. Wind Farm Design 4/7/2015

DESIGN OPTIMIZATION FOR A PASSIVE MESH SCREEN WAVE ABSORBER FOR THE CCOB

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

Improved Aerodynamic Characteristics of Aerofoil Shaped Fuselage than that of the Conventional Cylindrical Shaped Fuselage

Wind Effect on Smoke Exhaust by Natural Vent

Numerical Analysis of Wind loads on Tapered Shape Tall Buildings

Single-sided Natural Ventilation Driven by a Combination of Wind Pressure and Temperature Difference Larsen, Tine Steen; Heiselberg, Per Kvols

Design process to evaluate potential of wind noise at façade elements

Experimental Characterization and Modeling of Helium Dispersion in a ¼-Scale Two-Car Residential Garage

Numerical Fluid Analysis of a Variable Geometry Compressor for Use in a Turbocharger

NUMERICAL SIMULATION OF EFFECT OF URBAN GEOMETRY LAYOUTS ON WIND AND NATURAL VENTILATION UNDER MEDITERRANEAN CLIMATE

leading edge, where the flow is fully separated. Both for the means and peaks, smooth flow leads to the highest values. A good correlation between cav

Available online at ScienceDirect. Procedia Engineering 161 (2016 )

Numerical simulation of radial compressor stages with seals and technological holes

An experimental study of internal wave generation through evanescent regions

PRESSURE DISTRIBUTION OF SMALL WIND TURBINE BLADE WITH WINGLETS ON ROTATING CONDITION USING WIND TUNNEL

Sizing of extraction ventilation system and air leakage calculations for SR99 tunnel fire scenarios

Power efficiency and aerodynamic forces measurements on the Dettwiler-wind turbine

Effect of Diameter on the Aerodynamics of Sepaktakraw Balls, A Computational Study

Determination of the wind pressure distribution on the facade of the triangularly shaped high-rise building structure

Effect of Fluid Density and Temperature on Discharge Coefficient of Ogee Spillways Using Physical Models

Transcription:

BUILDING REGULATION AND THERMAL COMFORT: THE OPENING TYPOLOGY INFLUENCE ON NATURAL COOLING INSIDE OFFICE BUILDINGS IN MACEIÓ Christhina Cândido 1, Leonardo Bittencourt 2, Alexandre Sacramento 2 1 Federal University of Santa Catarina, Florianópolis, Brazil christhina@labeee.ufsc.br 2 Department of Architecture, Federal University of Alagoas, Maceió, Brazil lsb@ctec.ufal.br ABSTRACT The opening typology influences the ventilation of the rooms offering more or less resistance to the airflow. The Building Regulation of Maceio of 1985 determines the minimum openings area based on the floor s area, as 1/6 for light and 1/12 for ventilation. These items have a straight influence on the air flow pattern inside the rooms, as well as on the users thermal comfort. The aim of this study is to investigate three different openings typology in office buildings in Maceio city (sash, top hung and vertical pivot window) with open area based on the Building Regulation. Computational simulations where realized with PHOENICS 3.6 software on a typical office building. INTRODUCTION According to Gratia and Herde (2004), in office buildings, the long permanence of people stimulates the care with the surroundings quality. People who stays in these places have been required for a more healthy and exciting place, so that it is provided, generally, by a mechanical cooling device. However, natural cooling, if properly applied, can be effective during the occupation time. In these places people prefer to control cooling and lighting, what require a distinct cooling design or a natural cooling design. The flexibility the users prefer, many times, do not match the cooling devices used, because they do not consider the people adaptation to the place. These devices determine lighting and temperature conditions based on numeric data set from the cooling and light systems, generating, sometimes, a uncomfortable surrounding to occupants. However, people who use these places seem to be adapted to the temperature variation during the working time (NICOL, 2004; GRATIA; HERDE, 2003), accepting almost 3ºC above the temperature listed as comfortable (AYNSLEY, 1999). A large percentage of Brazil is classified as having a warm, humid climate. In those regions, natural ventilation combined with solar protection, is the most efficient building design strategy to reach thermal comfort by passive means. Maceio is a city located on the Northwest of Brazil (S 9 31' latitude). This weather is classified as hot and humid with two seasons witch are divided on a summer dry and a winter wet. The main temperature is 26 C and the annual thermal amplitude is 3,4 C approximately. Figure 1 The location of Maceió. Source: Google Earth (on line available. Access date: 11/03/2007) Regarding natural cooling, an important strategy for hot humid climates, the size, the shape and the position of the openings are major factors which determine the airflow configuration inside buildings (KUKREJA, 1978; OLGYAY, 1998). These items are influenced directly by the Building Regulation. That normalization is of great importance when specifying the minimal standards of the main architectural variables affecting human comfort, such as room s area, opening s area designed for lighting and - 1054 -

ventilation, the best ventilation strategy to be used, etc. If natural cooling is to be achieved is notable that the codes and the rules need to be reviewed in order to deal with the energy efficiency aspects (PEDRINI; LAMBERTS, 2003). The increase of natural ventilation inside the rooms depends on the architectural typology adopted and the specifications regarding the building openings. These openings may allow or make difficult to achieve a proper air flow inside rooms, being also responsible for rain protection, noise and solar radiation control. Thus, the opening s design must be carefully considered, otherwise it will endanger comfort conditions inside an ascertain place. The opening typology influences natural ventilation inside buildings offering more or less resistance to the airflow. The Building Regulation of Maceio determines the minimum openings area based on the floor s area, being 1/6 (opening to floor area ratio) for daylighting and 1/12 for natural ventilation. These items have a straight influence on the airflow determination inside the rooms, as well the users thermal comfort. On Maceio s office buildings the most common window typologies are the sash windows and top hung windows, made of glass and aluminum. The sash window does not allow the right conduction of the air flow, nor being partially opened on rainy days, Figure 2a e b. The top hung window allows a partial control of the aperture porosity but does not promote the airflow conduction. Nevertheless, its kind of opening, projected outside, allows some rain protection, figure 2b. Figure 2 Sash and top-hung windows. Source: The authors, 2005. The vertical or horizontal pivot windows seem to be an interesting typology because they promote the wind blow plus the airflow conduction, besides integrating inside and outside surroundings while offering protection against rain and solar radiation. However, windows with a poor control of airflow and conduction system and made of glass, as sash windows, seem to be the less appropriated; even being the most used opening typology, especially on office buildings. It is notable that the window type, on the most cases, does not take advantage of natural ventilation potential, even presenting the minimal area required to ventilation specified by the Building Regulation. The aspects related to the natural ventilation behavior, resultant from the effective area designed to catch ventilation (on the distribution pattern and wind speed) must be evaluated. This evaluation aims to contribute to future changes on the Building Regulation specifications. The paper investigates the impact of using three different windows typologies (sash, top hung and vertical pivot window), on the airflow distribution and on the wind speed inside office rooms, having the minimal area for ventilation as specified on the Maceio s Building Regulation. METHOD The method developed on this paper is a comparative analysis among the performance of three different kinds of windows (sash, top hung and vertical pivot window) on office buildings. The parametric analysis was carried out using a computational tool known as PHOENICS 3.6. This software is based on the Computer Fluid Dynamics (CFD), which came as an interesting alternative tool to the traditional Wind Tunnel on the studies of building natural ventilation. The results may be viewed as vectors, speed fields or isolines, where the wind speed variation is shown in a color score. The building typical model has rooms through a corridor, with eight floors, figure 1a. The model rooms have 18m² of area (3,00 x 6,00), 2,60 m of height and a centered window on the wall, measuring 1,10 x 3,00, with a 1,00 m of windowsill and a window shaft of 0,50 x 3,00 m. The window open area were considered as being 1/12 of the floor s area as an effective area to ventilation (1,50 m²), according to the Building Regulation of Maceio. There were studied rooms of the 1st, 5th and 8th floors; representing the lowest floor, a middleheight position floor and the highest floor. Thus, is expected a wide evaluation of the ventilation behavior inside the rooms because of the wind speed variation, elapsed by the wind gradient, on the several floors, figure 2b. The open door of the room is the outlet opening. - 1055 -

There were studied three kinds of squares: sash, top hung window and vertical pivot window, figure 2c. The first two are the most used typologies on the office buildings that were visited on the city. The third kind studied, vertical pivot, although isn t used in a large way on most of the office buildings; has less resistance to the air movement and has the possibility of guiding the airflow. Nevertheless, its potential has not being properly explored. The three squares were compared by its quantitative and qualitative fulfillment, regarding natural ventilation purposes. That information may be important to better understanding of the square modification impact to the air distribution and speed inside the office building rooms, to the same opening used area. Building typology: lateral corridor sala 1 sala 2 sala 3 sala 4 sala 5 sala 6 sala 7 sala 8 sala 9 sala 10 Wind angle 90º 8 corredor Window typology 0 1m 5m elevadores/ escadas meteorological station) and the openings height (JACKMAN, 1986 apud BITTENCOURT; CÂNDIDO, 2005). The wind mean speed measured at the meteorological station (V m ) was 3,00 m/s according to data of the station placed in Maceio airport, with 10m height far from the ground. The correction coefficients used were k = 0,21 e a = 0,33. The resultant gradient has a wind speed variation on each 1m, till it gets up to 30m. The wind speed on the first floor was 1,60 m/s, 2,41 m/s on the fifth and 2,77 m/s on the eighth. The findings were analyzed on a nine-point-grid plan with 1,5m height from the floor. This plan height is placed on the half room s height; analyzing the wind speed on each room s point and to estimate the mean speed inside it. RESULTS 1. SASH WINDOW On the first floor, the mean speed in the room was 0,86 m/s. The maximum speed was 1,47 m/s, obtained on the 1, 2 and 3 points, nearby the squares openings and the room s door, figure 4a. The minimal speed was 0,36 m/s on the 6 and 9 points (except on the 10 room, where the velocity of the point 9 was 0,73 m/s).in the other points of the room, the wind speed varied between 0,73 m/s and 1,10 m/s, totalizing 78% of the room s points. 7 Sash 6 5 4 3 2 i Top-hung 1 T 蒖 REO 0 1m 5m Vertical pivot Figure 3 Architectural variables resume. The wind s incidence angle adopted was 90º, which is the normal incidence to the façade. The wind speed was estimated using the rough coefficient of the ground to buildings placed in down town, the wind speed data (measured at the 0,86 0,36 1,47 Figure 4 Plant model and section sash window (1 st floor). - 1056 -

The sash squares, promotes a concentrated flush where the windows are opened. In 60% of the room the wind speed did not exceeded 0,36 m/s, corresponding to closed side of the sash window, figure 4b. It is noted the influence of the square s typology on the airflow distribution inside the room, favoring the air flow concentration on the open side of the window. Considering the outside wind speed as 1,60 m/s, the mean speed values were 43% and 62% of the outside speed available. The airflow is guided to the user s height, but with a low speed and a not uniform distribution, figure 4b. On the fifth floor, the mean speed values were larger than the ones of the first floor. On the rooms 1 and 2 the mean speed was 0,85 m/s, decreasing to 0,78 m/s on the room 3. On the room 4 the speed raised to 1,06 m/s, and 1,10 m/s to the rooms 5 and 6, 1,13 m/s to the room 7. On the room 8 the mean speed was 0,98 m/s and decreased to 0,73 m/s at rooms 9 and 10, picture 4a. users thermal comfort that keep themselves inside the not benefited spaces by the air movement. On the eighth floor, room 1, the mean speed was 0,77 m/s, increasing to 0,81 m/s inside the rooms 2 and 3, and 0,85 m/s inside the rooms 4 and 5. On the room 6 increase to 1,06 m/s, decreasing to 0,94 m/s on room 7. On the rooms 8 and 9 the values were 1,06 m/s and 1,02 m/s, respectively and on the room 10 the speed was 0,81 m/s. The raising of these values were influenced by the speed registered on the near window zone, so that the outside wind speed on this floor was 2,77 m/s. However, this acceleration did not produced a uniform air flow distribution inside the room, figure 6a. The area with wind speed of 0,36 m/s and 0,73 m/s is comparatively larger than the other floors, figure 4a, 5a and 6a. The air flow distribution is irregular, with vortex zones with low air speed, figure 6. The air flow is guided up to the ceiling, forced by the external air movement that moves itself in an ascendant way to pass over the obstacle created by the building, figure 6a. The adopted square is the sash, so that it does not promote the air flow guidance on the user level, figure 6b. 0,92 1,47 0,36 Figure 5 Plant model and section sash window (5 th floor). Regarding the airflow distribution, it is noted that the wind flow inside the room is not uniform. The formation of vortex zones on most of the rooms indicates that the effective aperture area to ventilation may not be enough to promote a uniform air flow distribution. The airflow guidance where the squares are opened, occurs without helping the airflow distribution inside the room, it can endanger the 0,90 1,84 0,36 Figure 6 Plant model and section sash window (8 th floor). 2. TOP HUNG WINDOW On the room 1, the wind speed was 0,60 m/s, 0,70 m/s on the room 2 and 0,67 m/s on the room - 1057 -

3. On the room 4 the speed was 0,83 m/s, 0,77 m/s on the room 5 and 0,80 m/s on the room 6. On the rooms 7, 8, 9 and 10 the speeds were 0,83 m/s, 0,87 m/s, 0,90 m/s and 0,80 m/s, respectively, figure 8. On this floor, the outside wind speed on the openings height was 1,60 m/s. Comparing with the inside air speed we can find the wind outside available percentage inside the room. The inside mean speed value varies from 40% to 60 % of the outside wind, figure 6a. The mean air speed inside the rooms with top hung windows were smaller. However, the values distribution on the rooms was uniform when using top hung windows, especially on the 4, 5, 6, 7 and 8 rooms. Just in 30% of the ambient the speed value was 0,30 m/s, representing a flow which is a not noticeable by the users. 0,91 1,20 0,30 Figure 8 Plant model and section - top hung window (5 th floor). On the eighth floor, the values were 0,80 m/s on the rooms 1 and 2, 0,87 m/s on the rooms 3 and 4. This values raises to 0,97 m/s on room 5 and 1,03 m/s on room 6. On the rooms 7 and 8 is 0,87 m/s and 0,80 m/s on the room 10. 0,78 1,20 0,30 Figure 7 Plant model and section - top hung window (1 st floor). On the fifth floor, the mean values of wind speed rises in relation of the first floor. On the room 1 the mean speed was 0,73 m/s, increasing to 0,87 m/s on the room 2 and 0,93 m/s on the rooms 3, 4 and 5. 0,97 m/s on room 6, decreasing to 0,93 m/s on room 7 and 8. On the rooms 9 and 10 the value was 0,90 m/s, picture 7a. The available percentage of wind speed that were of 2,41 m/s on the fifth floor, vary between 31 and 40 %. It is noted that the typology of square adopted reduces the blowing wind to the ambient. 0,90 1,20 0,30 Figure 9 Plant model and section - top hung window (8 th floor). - 1058 -

In relation of the air flow distribution, it is noted that most part of the room display air movement, figure 9. The wind speed values were higher than the other floors. Benefited by the ascending external component, the air flow is induced to enter by the top hung window, figure 9b. the room 4 it raises to 1,64 m/s, decreasing to 1,54 m/s on the room 5 e 1,35 on room 6. On the room 7 the mean speed values was 1,68 m/s, decreasing to 1,38 m/s and 1,35 m/s on the 9 and 10 rooms, figure 11a. 3. VERTICAL PIVOT WINDOW Because of the permeability promoted by the square, the wind reached most of the room area in relation to the other kinds of squares adopted, figure 5a, 8a and 10a. The mean speed on the rooms 1, 2 and 3 was 0,71 m/s. 0,86 on the room 4, raising to 1,01 m/s on the room 5. On the room 6 was 0,82 m/s. The external available wind percentage varied between 47 % and 67 %, considering the approximated speed of 1,60 m/s on the analysis plan height. It is noted that the vertical pivot typology promoted a better use of the external wind speed with the same opening area of the sash and top hung windows. 1,38 2,02 0,67 Figure 11 Plant model and section - vertical pivot window (5 th floor). 0,83 1,69 0,67 Figure 10 Plant model and section - vertical pivot window (1 st floor). On the eighth floor, in relation of the air low distribution, there were differences among the values, so that they are not absolute values. However, analyzing the air flow inside the room, there are few vortex areas. The air speed is increased to not less than 0,67 m/s, figure 11a. The mean values of the wind speed were higher, being over 1,0 m/s inside every room. On the room 1 it was 1,08 m/s, raising to 1,38 m/s on rooms 2 and 3 and 1,57 m/s on the room 4. On the room 5 the average was 1,72 m/s, decreasing to 1,16 m/s on the room 6. On the room 7 that value raises to 1,57 m/s and keep 1,61 m/s on the rooms 8, 9 and 10. On the fifth floor, the mean speed values were 42 and 70% of the external value (2,40 m/s). On this typology, the squares resist less to the air movement, so that it promotes a better ventilation pattern inside the examined rooms. It presents an uniform air flow distribution and a reduced vortex zones, figure 11a. The mean speed of the room 1 was 1,01 m/s, 1,24 m/s on the room 2 and 1,27 m/s on the room 3. On - 1059 -

1,47 2,02 0,67 Figure 12 Plant model and section - vertical pivot window (8 th floor). CONCLUSION This paper discusses the impact of using three different windows typologies (sash, top hung and vertical pivot window), on the airflow distribution and the wind speed inside office buildings, having the minimal area for ventilation as specified on the Maceio s Building Regulation. Results indicate the square typology influences on the ventilation values inside the rooms. The air flow distribution was directly affected by this item, especially on the vortex zone formation. Although the square s opening kind is an important item to ventilation, it is not properly considered in the Building Regulation specifications. It is suggested that future investigation should establish correction factors to consider the openings typology effectiveness, informing the impact of adopting different square typologies on the wind speed inside the room. The square fulfillment has demonstrated being influenced by its position on the building (floor), as verified by the ascendant flow behavior analysis through the studied floors. Depending on the floor s height the air flow direction inside the room comes from up or down direction. That direction is still influenced by the typology and openings position of inlet and outlet. The outlet openings demonstrate an influence on the horizontal distribution standard of the air flow inside the studied rooms, so that it would be better used on buildings design. It is suggested, however, more studies about typology and position of the outlet openings needs to be carried out. The vertical pivot square demonstrated a better fulfillment regarding the air flow distribution and wind speed inside the rooms. The sash square typology promotes a blowing wind concentrated near the openings area and because of the fixed part the vortex zone formation occurs inside the rooms. The top hung window, does not promote a uniform air flow inside the rooms; it works like a obstacle to the entering wind due to its shape, especially on the first and fifth floors. The necessity of varying the openings typology on different floors, although it is not the Building Regulation focus, could be used by designers. Regarding the outlet opening importance, that would be the most studied items by the designers, in order to promote better thermal comfort conditions inside the rooms. These items could be useful on the rules creation and more suitable codes, thus it would improve the comfort and energetic efficiency of the built ambient. However, it is important to designers to dominate the ventilation principles to use it on the buildings design process. Associated to the restricted position of the standard, the professional must comprehend the rules to built adequately using natural ventilation as a cooling strategy for the built environment. ACKNOWLEDGEMENTS The authors would like to thank CAPES - Fundação Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, an agency of the Brazilian Government for post-graduate education, for the financial support to undertake this project. REFERENCES AYNSLEY, R., Estimating summer wind driven natural ventilation potencial for indoor thermal comfort. Journal of Wind Engineering and Industrial Aerodynamics. 83, pp. 515-525, 1999. BITTENCOURT, L. Ventilation as a cooling resource for warm humid climates: An investigation on perforated block wall geometry to improve ventilation inside lowrise buildings. PhD Thesis - Architectural Association Graduate School, Londres, 1993. BITTENCOURT, L., CÂNDIDO, C., Introdução à Ventilação Natural. EDUFAL: Maceió, 2005. - 1060 -

GRATIA, E., HERDE, A. How to use natural ventilation to cool narrow office buildings. Building and environment, fevereiro de 2004. GRATIA, E., A. DE HERDE. Is day natural ventilation still possible in office buildings? Building and environment, outubro de 2003. NICOL, F. Adaptive thermal comfort standards in the hot humid tropics. Energy and Buildings: Elsevier Science, julho de 2004. OLGYAY, V. Arquitectura y clima. Manual de Diseño bioclimático para arquitectos y urbanistas. Editorais Gustavo Gili: Barcelona, 1998. PEDRINI, A.; LAMBERTS, R.. Influência do tamanho e forma sobre o consumo de energia de edificações de escritório em clima quente ENCAC 2003 - VII Encontro Nacional sobre Conforto no Ambiente Construído, Curitiba, 2003. Anais... Curitiba: 2003. - 1061 -