Automatic Control Unit. Controlmatic E. Type Series Booklet

Similar documents
Automatic Control Unit. Controlmatic E.2. Type Series Booklet

Automatic Control Unit. Cervomatic EDP.2. Type Series Booklet

KSB Delta Compact Type Series Booklet

KSB Delta Compact Type Series Booklet

Governor with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

3-Way Safety Block DSV

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Tightness controls TC 1 3 and TC 4

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves single-stage atmospheric operating mode GB-(LEP) 057 D01

Old documentation - Only for your information! Product is not available any more!

SPIROVENT VACUUM DEGASSERS

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH

Pressure switches for air and water CS

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Integrated gas-air system GB-GD 057 D01

Pressure independent control valve (PICV) FLOWMATIC

Etanorm V Type Series Booklet

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 055 D01

Old documentation - Only for your information! Product is not available any more!

Air Purge Unit. Series: LSP-compact Type: EJG 2-2. (Controlled with DigiFlow 515) Installation & Operation Manual 11/2014

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

Self-operated Pressure Regulators for special applications

Tightness control TC. Product brochure GB 3 Edition AGA

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

KIT. Small Automatic Water Boosters KIT MODELS

2-port and 3-port seat valves, PN16

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

KMW3000C. User Manual. Water Chiller for Xcalibur and Gemini systems. Version 1.6, September 2010

Compact pressure switches for gas and air

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG Variable air/gas ratio control with solenoid valve VAV

Instruction Manual Contact Pressure Vacuum Gauge

Safety. Operating instructions Solenoid valve for gas VG 10/15 VG 65 DANGER. Contents WARNING CAUTION. Changes to edition 11.14

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

FLOW. State of the Art ELECTRONIC PUMPS CONTROLLERS. * Electronic starters. * Inverters. * Protection devices YOURWATER UNDER CONTROL

Pressure Measurement Single-range transmitters for general applications

3-port seat valves with externally threaded connection, PN 16

2-step solenoid valve Type ICLX

2-step solenoid valve Type ICLX

2-Port Seat Valves with Flange, PN 16

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Airfix. Flamco. Flamco. Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX D AIRFIX D-E

Hydro Dome GRUNDFOS INSTRUCTIONS

VERTICAL AIR COMPRESSORS

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

KGW - ISOTHERM. Operating Instructions. Level controlling device for liquid nitrogen LEVEL CONTROL LN2

2-port seat valves PN25 with externally threaded connections

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

2-Port and 3-Port Seat Valves with Female Thread, PN16

Solenoid valves VZWF, force pilot operated

2-Port Seat Valves with Flange, PN 16

EXH. Specifications. Descriptions. Min. working pressure MPa

Proportional Pressure-Relief Cartridge Valve, Size 2...4

CALEFFI. Ball zone valves. series /03 GB

Rigel 601 CHECKBOX. Instruction Manual. 348A551 Issue 2.0. April Seaward Electronic Ltd. Issue 2.0

Old documentation - Only for your information! Product is not available anymore!

VRF. Technical Data Book. DVM S ECO for Europe (R410A, 50Hz, HP) Model : AM***KXMDGH/EU

Inverse Prop. Pressure-Relief Cart., Size 2 4

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

Columbus Instruments

Proportional Pressure-Relief Cartridge Valve, Size 2...4

High Performance BSP Dial Up Pattern Pressure Reducing Valve

Valve Proving System VDK 200 A S06*

WhirlWind Multifunctional gas control Fully integrated gas-air system with control and safety function GB-WND 055 D01

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

Safety and Shut-off Block SAF/DSV

Valve Proving System VDK 200 A S02

RTG 25. Introduction

KERN EG/EW Version /02

Inverse Proportional Pressure-Relief Cart., Size 2 4

Pressure transmitters EMP 2

Residential Pressure Booster Systems

RTG 311 pressure regulators are included within the direct acting and balanced valve regulator class.

2-port and 3-port valves PN 16

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

Selection of ICF made easy Save even more time with ICF

Installation, Operation & Maintenance Instructions

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

Gas density monitor With integrated transmitter Model GDM-100-TI

Tm: 65 C (149 F) max. Tm: 65 C (149 F) max. Tm: 65 C (149 F) max. Tm: 65 C (149 F) max. Tm: 90 C (194 F) max. Tm: 98 C (208 F) max.

SIHI LPH-X - Liquid Ring Compressors

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)

DESIGN ENVELOPE 6800 G 1 DUTY PUMP

STV / STVL. Danfoss STV series of balancing valves provide testing and balancing of circuit flow for hydronic heating or cooling systems.

The Discussion of this exercise covers the following points:

Series IRV1000/2000/3000

Type 4708 Supply Pressure Regulator

Two-port seat valves

Transcription:

Automatic Control Unit Controlmatic E Type Series Booklet

Legal information/copyright Type Series Booklet Controlmatic E All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any other purpose, nor otherwise transmitted, published or made available to a third party without the manufacturer's express written consent. Subject to technical modification without prior notice. KSB Aktiengesellschaft, Frankenthal 08.10.2013

Controlmatic E Designation Example: Controlmatic E Key to the designation Code Description Controlmatic Type series E Single-phase AC Configuration and function Main applications Pressure-controlled starting, stopping and monitoring of small pumps in water supply systems Can be used with the following pumps ( Page 6) Type series Size Connection Multi Eco 33 E, 34 E, 35 E, G 1 36 E, 65 E Ixo 45 E, 55 E, 65 E, G 1 1 / 4 48 E, 58 E S 100D 1/7, 1/9, 1/12, 1/14, 1/16, 2/7, 2/11, 2/15, 2/18, 4/4, 4/6, 4/9, 4/12, 7/5, 7/7, 7/9 G 1 1 / 4 Fluids handled Drinking water Service water Stormwater Fire-fighting water Cooling water Operating data Operating properties Characteristic Value Flow rate Q Up to 10 m 3 /h (2.77 l/s) Minimum flow rate Q min 0.1 m 3 /h Start-up pressure (adjustable) p 1.5-2.6 bar Design of Controlmatic E 1 Housing 5 Green signal lamp - Energised 2 Pressure gauge 6 Amber signal lamp - Pump running 3 Plug socket (IP44) 7 Red signal lamp - Fault or lack of water 4 Power cable with shockproof plug Function The pump can be connected via the plug socket (3) of the automatic control unit. Once the power cable with shockproof plug (4) has been connected to the power supply, the automatic control unit is ready for operation. The green signal lamp (5) is lit. When a shut-off valve in the piping is opened, the system pressure decreases and the pump is started up. The system pressure is indicated at the pressure gauge (2). The pump starts to deliver fluid and the amber signal lamp (6) is lit. When the tap has been closed and the flow rate is zero, the pump is stopped after 10 seconds. Protective functions The pump is protected against dry-running by simultaneous monitoring of pressure and flow rate. If there is a lack of water, the automatic control unit stops the pump and the red signal lamp (7) is lit. Materials Overview of materials used Component Housing Membrane Material Polyamide Elastomer Controlmatic E 3

Product benefits Easily connected to power supply by shockproof plug The pump is started and stopped automatically by simultaneous monitoring of pressure and flow rate. Variety of use due to user-definable start-up pressure (1.5-2.6 bar) Dry-running protection by stopping the motor User-friendly due to integrated pressure indication Certifications Designation Valid in: Note ACS France French drinking water approval Selection information System pressures 10 bar may damage the automatic control unit and must be avoided by all means. The start-up pressure of the automatic control unit must always be lower than the maximum pressure at zero flow. Minimum flow rate: 0.1 m³/h The start-up pressure has been set to 1.5 bar. Maximum pressure capability: Pressure suction side + pressure max. pump (at zero flow) 10 bar If in doubt about the suction side pressure: either add a safety margin of 3 bar to the nominal pressure (Pressure suction side + 3 bar) + [Pressure max. pump (at zero flow)] 10 bar or fit a pressure reducer (stabiliser) between the pump and the automatic control unit or on the pump's suction side, to prevent excessive pressure. If pressure surges are to be expected in the system as a result of quick-closing valves (e.g. solenoid valves) please contact KSB to check the unit's suitability for the specific application. H 1 2 3 H 5 6 7 0 4 Q 0 Q H/Q diagrams 1 Minimum flow rate 5 Curve to be selected 2 Minimum start-up pressure 6 Curve to be avoided 3 Pump start-up point 7 Maximum operating point 4 Pump stop point Pressure curve Unlike domestic water supply systems with accumulators, pumps operated with automatic control units maintain a characteristically constant pressure at any flow rate. 4 Controlmatic E

Pressure curves Technical data Selection table Description Value Maximum operating pressure 10 bar 1) Flow rate 10 m 3 /h (2.77 l/s) Enclosure IP 44 Maximum ambient temperature 0 to 60 C Maximum fluid temperature 0 to 60 C Mains voltage 1~230 V, 50/60 Hz Maximum current requirement 10 A Protection against lack of water Yes Restart after lack of water Manual Weight 1.3 kg Mat. No. 90053395 Dimensions Dimensions [mm] - The pressure gauge can be fitted in two different positions. 1) The automatic control unit must be protected against any pressures exceeding the maximum operating pressure. Otherwise, the automatic control unit might be damaged! Controlmatic E 5

Notes on installation Typical installation positions NOTE! The automatic control unit is not suitable for outdoor installation and must be protected from weather. Accessories Connnection parts Connnection parts Description Connection Mat. No. [kg] Connection part made of brass for Controlmatic for Multi Eco type series (1 piece) Rp 1 / G 1 39019415 0.2 for Ixo, S 100D type series (1 piece) Rp 1¼ / G 1 39019530 0.2 6 Controlmatic E

KSB Aktiengesellschaft 67225 Frankenthal Johann-Klein-Str. 9 67227 Frankenthal (Germany) Tel. +49 6233 86-0 Fax +49 6233 86-3401 www.ksb.com 5125.53/03-EN 08.10.2013