DGZfP-Proceedings BB 90-CD Lecture 4 EWGAE 2004

Similar documents
CONVECTION SECTION FAILURE ANALYSIS AND FITNESS-FOR-SERVICE ASSESSMENT

STRUCTURAL INTEGRITY EVALUATION OF CNG COMPOSITE CYLINDERS BY ACOUSTIC EMISSION MONITORING

Acoustic Emission Testing of The Shell 0f Electromagnetic Valve

Acoustic Emission Testing

EXAMINATION OF AE WAVE PROPAGATION ROUTES IN A SMALL MODEL TANK

Fitness for Service Assessment of Ageing Pressure Vessel Experiencing External Corrosion: A Case Study

APPLICATION OF ACOUSTIC EMISSION DETECTION TECHNOLOGY ON MULTILAYER BINDING HIGH PRESSURE VESSEL

Liquefied gas cargo tanks and process pressure vessels

PIP PNE00012 Piping Examination and Leak Test Guide

STRUCTURAL INTEGRITY EVALUATION OF CNG COMPOSITE CYLINDERS BY ACOUSTIC EMISSION MONITORING

IGEM/TD/1. Background, Development, Changes J V Haswell

MSC Guidelines for Pressure Vessels

BLOCKAGE LOCATION THE PULSE METHOD

Hydrostatic Testing of In-Situ Pipelines & Spike Testing. Colin Silla, PE, PMP Southeast District Manager 6/27/18

MANUFACTURING PROCEDURE SPECIFICATION INSPECTION TEST PLAN

UKOPA Dent Management Strategy

EWGAE 2010 Vienna, 8th to 10th September

INTERPRETATION OF THE REGULATIONS/STANDARDS...

Flange Bolt Torquing. for Resistoflex Plastic-Lined Piping Products. Torquing. Retorquing. Hydrotesting. Annual retorquing

Subpart E. Pressure Testing

CERTIFICATION PROGRAM FOR ASSESSING THE MECHANICAL INTEGRITY OF PRESSURE VESSEL SYSTEMS

Enbridge Pipelines Inc. PIPELINE INTEGRITY AXIAL CRACK THREAT ASSESSMENT

OPENINGS AND REINFORCEMENTS 26

HEALTH AND SAFETY EXECUTIVE HM NUCLEAR INSTALLATIONS INSPECTORATE

A FINITE ELEMENT PROCEDURE TO MODEL THE EFFECT OF HYDROSTATIC TESTING ON SUBSEQUENT FATIGUE CRACK GROWTH

CERTIFICATION OF COMPLIANCE OF THE USER S DESIGN SPECIFICATION

NATURAL GAS MAINTENANCE. Part 192 Subpart "M"


INTEGRITY MANAGEMENT OF STRESS CORROSION CRACKING IN GAS PIPELINE HIGH CONSEQUENCE AREAS

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

NASA AEROSPACE PRESSURE VESSEL SAFETY STANDARD

RECENT IMPROVEMENTS REGARDING ULTRASONIC CRACK INSPECTION OF PIPELINES Herbert Willems, Thomas Hennig NDT Global, Stutensee, Germany

RIGID RISERS FOR TANKER FPSOs

Regulations Respecting Compressed Gas Pressure Vessels

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

Optimizing Gas Supply for Industrial Lasers

Engineering Data Sheet

A Study of Pressure Safety Valve Response Times under Transient Overpressures

[PDF] DOWNLOAD PRESSURE VESSEL DESIGN FREE UNQUOTE BOOKS

MFP14-PPU (Vented) Automatic Packaged Pump Units

PVP2006-ICPVT

I. CHEM. E. SYMPOSIUM SERIES NO. 85 MULTI-STAGE OVER PRESSURE PROTECTION AND PRODUCT CONTAINMENT ON HIGH PRESSURE POLYMERISATION REACTORS

Analysis A1 and B2 Methods of Hydrostatic Testing Applied at Gas Pipeline; Cause Study A1-Method

Design and Analysis of Reactor Dish Vessel

Damage evaluation for Type-ll CNG cylinder by the analysis of AE parameters

THIN CYLINDERS AND SHELLS

API-510 PRESSURE VESSEL INSPECTOR

EFFECTIVE & RELIABLE INSPECTION OF FIN-FAN COOLER TUBES

Blowdown vessels Meeting the requirements of HSE PM60

Batch centrifuge basket design.

GUIDELINES FOR CONDUCTING HYDROGENATION REACTIONS

STANDARD SPECIFICATION FOR SPLIT TEES (HOT TAP MATERIAL)

Pressure Strength Test Requirements for Hermetic Refrigerant Compressor Housings Using Fatigue Analysis

Justification of Risk Reduction through In-Service Inspection / REDUCE

DESIGN AND ANALYSIS OF PRESSURE VESSEL

Vibration Related Failures of Small-Bore Attachments

I. CHEM. E. SYMPOSIUM SERIES NO. 85

BODY OF KNOWLEDGE API-510 PRESSURE VESSEL INSPECTOR CERTIFICATION EXAMINATION

MECHANICAL REDESIGN OF ION EXCHANGE RESIN VESSEL BOTTOMS AT HULETT REFINERY

SCANNING ELECTRON MICROSCOPY ANALYSIS OF ELASTOMERIC O-RINGS AND SPRING SEALS FRACTURED DURING RAPID GAS DECOMPRESSION.

Becker* Products Below Ground Ball Valve Regulators

The American Society for Nondestructive Testing

User Information Sheet 024

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

ASME Boiler & Pressure Vessel Code Analysis of the 1497 MHz High-Current Cryomodule Helium Vessel

2.1 Introduction to pressure vessels

APPENDIX 1. PART 10: Leak Detection Inspector, Level 1, 2 and 3 CERTIFICATION SCHEME FOR PERSONNEL. 3 rd Edition, February 2016

APPLYING VARIABLE SPEED PRESSURE LIMITING CONTROL DRIVER FIRE PUMPS. SEC Project No

2 FUSION FITTINGS FOR USE WITH POLYETHYLENE PRESSURE PIPES DESIGN FOR DYNAMIC STRESSES

2003 WJTA American Waterjet Conference August 17-19, 2003 Houston, Texas Paper PIPE THREADS-WHAT IS THE LIMIT?

THE PROCESS OF JOINT INTEGRITY

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

Regulated Oil and Gas Companies under National Energy Board Jurisdiction

Guided Wave Testing (GWT)

1 Exam Prep. Tabs and Highlights

APPENDIX B TESTING PROTOCOLS. Method A: Straight Test Method B: Angular Deflection Test. Method C: Shear Load Test

THE BAKER REPORT HOW FINDINGS HAVE BEEN USED BY JOHNSON MATTHEY TO REVIEW THEIR MANUFACTURING OPERATIONS

Vibration and Pulsation Analysis and Solutions

Vibration Analysis and Test of Backup Roll in Temper Mill

DIFFERENT SOLUTIONS TO INSPECT PLATFORM RISERS. By R van Agthoven and H Quakkelsteijn, ApplusRTD, Rotterdam, The Netherlands

Inspection Credit for PWSCC Mitigation via Peening Surface Stress Improvement

Dri-Line Mk3 Monnier Compressed Air Drain Trap

SCREEN OPENINGS FOR STRAINERS

Sense Element Pump Ripple Fatigue

The Protection of Silos From Over. Pressurisation During Filling

UNIT 15 WATER HAMMER AND SURGE TANKS

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

Improving distillation tower operation

Installation, Operating, Maintenance and Safety Instructions for. Pressurised water systems for boats

ASSESSMENT AND ANALYSIS OF PIPELINE BUCKLES

Event Time Event Name Meeting Room Sunday, January Monday, January

Pipeline Flooding, Dewatering and Venting Dr Aidan O'Donoghue, Pipeline Research Limited, Glasgow, Scotland

Standard Practice for Eddy-Current Examination of Steel Tubular Products Using Magnetic Saturation 1

TSS21 Sealed Thermostatic Steam Tracer Trap

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

Elimination of Oil Residual inside the Copper Pipe Using Ladder Technique

MITIGATING PIPE AND RISER HYDRAULIC PIPELINE ISSUES WITH THE I-RISER PLUS

Use of Underwater Dry Welding for In Situ Repair to Offshore Structures. Sabine Powell 02/12/2016

MF2M Monnier Miniature Compressed Air Filter

PV4 and PV6 Piston Valves

Transcription:

ACOUSTIC EMISSION EXPERIENCE WITH AE MONITORING OF NEW VESSELS DURING INITIAL PROOF TEST Phillip, Cole, Physical Acoustics Limited, Cambridge, U.K; Stephen, Gautrey, Physical Acoustics Limited, Cambridge, U.K; Keywords: Acoustic emission, proof test. ABSTRACT This paper looks retrospectively at experiences with the AE monitoring of new vessels during initial proof-test and discusses the implications for applying the proposed European Standard for AE monitoring of proof tests. Case histories discussed in detail are a new reactor and a storage sphere, both intended for refinery service. Comparison between first and second loading and the practical implications for running tests according to the code are discussed. BACKGROUND The initial proof test of equipment serves two purposes, the first is to mechanically stress relieve the vessel by loading well above the intended service stress, typically x1.45, this yields high stress areas and blunts crack tips, retarding subsequent fatigue crack initiation, and ensuring that local microstructure is operating well below yield. For vessels that do not have post-weld heat treatment, typically those <30mm thick, this is very important as the local welding residual stress will be up to yield in many areas. The second purpose is to demonstrate that the vessel does not leak under pressure. The design codes specify inspection requirements prior to the test to ensure significant defects are not present, but they do not specify inspection following the proof test. This means that any defects which grow during the proof test will be put into service with the vessel. Acoustic emission monitoring during the first loading at initial proof test can help to identify growing defects or problems with material and heat treatment but interpretation is complicated by the emission that occurs as a result of normal stress relief, so care must be exercised. ASME defines criteria for AE monitoring of proof tests, and in the event that these are exceeded during the first application of load, as is always the case for vessels that have not been heat treated, allows a second cycle to be applied. If the second cycle is quiet then any defects present are considered stable and the vessel passes the test. It may however still have large but stable defects present, so careful analysis of the initial loading to try and identify these is important if you wish to minimise the defects that find their way into subsequent service. VERTICAL REACTOR SHOP HYDROTEST Material: A516-70 Size: 2.74 metres diameter, 13.9 metres high (tested horizontally) Thickness: 25mm Design pressure: 25.2 bar (403 psi), at 94 degrees C Hydrotest pressure: 38.75 bar (620 psi) at ambient, ~10 degrees C (January 1993) 75

Intended service: Special features: Refinery, hydrogen. Catalyst loading man-way in top head, ~half diameter of vessel. Seventeen integral pre-amplifier sensors were used to monitor this vessel, from the signal attenuation measurement (see figure 1) this was far more than required according to ASME, however, planar location was used to aid interpretation of the emission, particularly useful for the first loading of a new vessel, and this requires many more sensors as each emission must reach three sensors to be located. Planar location highlights specific areas, comparison of relative emission density from welds over the entire vessel gives an indication of which areas might be growing defects or have material problems, allowing follow-up NDT to check these out efficiently. Attenuation Amplitude 100 90 80 70 60 50 40 30 20 10 0 0 2000 4000 6000 8000 Distance mm Figure 1 Attenuation of the Hsu-Nielsen source on vessel The first pressurisation initially appeared quite normal, with emission starting from low loads as expected as a result of stress relief (figure 2 shows the history of hits, energy and amplitude for the entire vessel, the vertical black line is the start of the final hold period), it became clear that a large amount of emission was from a single weld, the one around the catalyst loading man-way, sensor 13 was adjacent to this weld where it was close to the top head circumferential weld. This emission was so pronounced that the weld drew itself out on the location plot (figure 3a, 3b), the first cluster appeared at a small % of test pressure, and had a total of >200 events by the end of the first loading, (figure 4) by which time clusters had appeared around that entire weld circumference. At the time this test was carried out there was no official CEN location code, had the test stop criteria from the code been applied the test would have been repeatedly stopped for NDT of these and other cluster locations (>26 in total). Emission continued to the end of the final hold period, predominantly from the top man-way area. The second loading was totally quiet, until at ~70% of the previous maximum pressure emission suddenly started, once again predominantly from the top man-way weld near sensor 13 (figure 5). 76

Figure 2 History of hits, energy and amplitudes for the first loading (vertical black line is start of final hold period) Figure 3a Top head of vessel showing large catalyst loading man-way. Figure 3b Location of emissions around top man-way weld during first loading. Figure 4 Cluster history from small section of the man-way weld. 77

MONPAC analysis of the first pressurisation produced grade E for the sensors around the man-way area, this activity reduced to C on the second loading resulting in a recommendation for further evaluation and possible follow-up NDT. Post test, extensive NDT was carried out to the man-way weld area, both from inside and outside, no reportable indications were found. Since 90% of the emission from the vessel had come from the one weld there were still questions and an investigation into the manufacturing process ensued. The outcome of this was the discovery that a much lower weld pre-heat had been used on the man-way weld than on any other weld on the vessel, resulting in higher residual stresses, clearly not fully relieved after even two cycles to proof pressure. The reason given for the lower pre-heat was that from a design standpoint the man-way had been treated as a pipe, allowable under the codes, despite this clearly being the most highly stressed part of the vessel. The end-users concern was the high risk of hydrogen damage to the area once the vessel went into service, and the risk of cracks developing from the still present high local stresses from manufacturing. It is interesting that despite emissions with source amplitudes well in excess of 80dB (usually associated with cracking) no reportable indications were found by NDT. One possibility is that micro-cracking was distributed around the weld and there was as a result no individual big crack for NDT to find. Localised inspection may not be sensitive to micro-cracking distributed around a large area; however this can still be a threat to integrity. Figure 5 History of emission during second loading (vertical black line is start of final hold period) 78

STORAGE SPHERE INITIAL HYDROTEST Diameter: 21.3 metres Legs: 10 Material: BS5500 carbon steel Thickness: ~18mm Design pressure: 4.83 bar First Hydro pressure: 6.79 bar Subsequent hydro pressure: 6.1 bar Forty six sensors were used to monitor this vessel, due to the thin wall (~ one wavelength) the attenuation was relatively high, since energy rapidly transferred into the liquid. This made planar location of smaller signals impractical as the test threshold would have needed to be so low that channels would be continuously active from emission resulting from normal stress relief, the alternative was many hundreds of sensors, again impractical and too costly. The first loading produced high levels of activity from all areas of the sphere, (figure 6) suggesting extensive yielding, and high amplitudes indicated possible microcracking, activity exceeded the evaluation criteria many times over. Figure 6 Activity from first proof test and repeat loading of a 21m sphere Zone intensity location analysis of the initial loading produced nothing less than a C grade, with eighteen D zones, and five E zones (figure 7). Planar location was carried out but the located data represents only 3.7 % of the total emission, and did not identify active clusters (figure 8). 79

Figure 7 1 st Load Zone intensity analysis Figure 8 Planar location, typical view. The second loading was relatively inactive; however there was still one D grade near the top head pressure relief valve stack, (fig 9,10), follow-up NDT found no indications. Figure 9 2 nd Load Zone intensity analysis Figure 10 2 nd Load planar location. A few years after putting the sphere into service it was taken out for inspection, and MPI carried out internally, thousands of HAZ cracks were found, present in most of the welds. These were ground out together with one crack that was quite deep, approaching 50% through wall. Metallurgical analysis showed all the cracks to be of manufacturing origin, with no evidence of in-service growth. The implication, since the vessel was inspected prior to its initial hydro-test, was that the cracks opened up during the first loading. DISCUSSION It is clear that AE gives useful information during initial proof testing; there are cautions when using the method however: - Emission resulting from crack growth during the first loading can be difficult to identify amongst normal emission from expected stress relief. Intensity analysis 80

identifies the higher levels of activity, and where it is practical and cost effective to use planar location this can be enormously useful to identify hot spots. -The second loading is relatively easy to interpret, no emission means no propagating defects or continuing stress relief, this should be the case. - Abnormal levels of emission from stress relief may be the result of inadequate weld pre-heat or other manufacturing problems that leave high residual stresses in the welds, not necessarily defects that can be found by NDT. It is also common to see abnormal levels of activity from stress relieved vessels, where the manufacturer has welded attachments after the stress relief has been carried out!!! -Perhaps the most controversial issue is vessels that pass on the second loading, what this means is that any defects present are stable under these stress conditions, it does not mean the vessel is defect free, defects may have grown or yielded during the first proof and become stable. The question is whether you want even these defects to go in to service, if not then inspection after the hydro-test is necessary if there is any significant emission, even on the first loading. -Where test stop criteria are used for the initial loading, it is important to realise and plan for the eventuality that multiple clusters may mean multiple test interruptions for NDT, especially if the activity is the result of excessive weld stress relief. The practicality of this may often be questionable. 81