Flow meter. bellow vaporizer. APL valve. Scavenging system

Similar documents
The Anesthesia Machine (con t) The primary cause of machine malfunction is failure to check Never start without the American Express items What is the

Anesthesiology Research and Scholarship. Follow this and additional works at:

Anes Machine Use and Pre-use Check - CA1 focus

HONG KONG COLLEGE OF ANAESTHESIOLOGISTS TECHNICAL GUIDINES RECOMMENDATIONS ON CHECKING ANAESTHESIA DELIVERY SYSTEMS

Draeger Fabius GS Pre-Use Check

Working version subject to Departmental approval. Drafted by Dr. Olympio and reviewed by clinical members of The Capital Equipment Committee

Recommendations on Checking Anaesthesia Delivery Systems

Anesthesia Machine Intro

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

Aespire 7100 Essential performance Compact design

O-Two Self-Study Guide. Equinox Relieve

Breathing Systems. Professor Khalid Bashir

I. Subject: Compressed gas cylinders, regulators, and portable liquid systems.

Checking a Breathing System

Narkomed MRI-2. A perfect fit for the MRI environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

PORTER INSTRUMENT COMPANY, INC.

S/5 Aespire. Quick Reference Guide

Selecting and Connecting Breathing Systems

Anesthesia Machine Care and troubleshooting Charlene J. Williams, CRNA, MSN Assistant Professor Anesthesiology Nursing

Anesthesia Machines. Inhaled Anesthetic Agents

Hallowell EMC 2000 and 2002 Veterinary Ventilator Set-up, Use, and Troubleshooting

FLOWMETER UNITS FLOWMETER DEVICES, BY-PASS SYSTEMS

AUTOVENT 4000 VENTILATOR

Medical Instruments in the Developing World

THE GE AISYS ANAESTHETIC MACHINE

Keeping anaesthetic pollution to minimum in theatre environment

Your patients, our primary focus. Siesta i Whispa anesthesia machine

Prima SP2/3 Anaesthetic Machine Range Service Manual Partnership for Life

VAPOMATIC ANESTHETIC VAPORIZER

INTERNATIONAL ISO STANDARD Anaesthetic machines for use with humans. Appareils d anesfhesie pour utilisation chez I homme

AIR/OXYGEN BLENDER INSTRUCTION MANUAL

State-of-the-art anesthesia technology

MANUAL GAS MANIFOLDS

Operators Manual. Supera Wall Mount Anesthesia Machines. Models: M2300 M2500. (All shown with optional equipment) M2300 M2500

Welcome to the Specialized Medical Services Respiratory training webinar series!

Installation Operating Instructions for Duplex Manual Manifolds PX-TMD Series

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

The centerpiece of a comprehensive anaesthesia workstation

MEDICAL EQUIPMENT CATALOG

CHAPTER 16 %UHDWKLQJ*DV0L[LQJ3URFHGXUHV

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor)

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

AND OPERATION INSTRUCTIONS

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

Your patients, our primary focus

Hallowell EMC Anesthesia WorkStation Operating Manual

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200

CPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Apollo Safety Features

Safe Accurate Reliable. CWM-301 Anesthesia System

M5400 Operators Manual

OPERATING AND MAINTENANCE MANUAL

Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA USA Tel: Ref Rev.

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% ADMINISTRATION SYSTEM (01EQ7000E) DEMAND VALVE (01EQ7001E) O-TWO MEDICAL TECHNOLOGIES INC.

Columbus Instruments

Composite Pistol-Type Air Needle Scaler OWNER S MANUAL

ACV-10 Automatic Control Valve

Spring Loaded Regulators Constant Loaded Regulators Twin Parallel Flow Regulators Field Service Regulators

SERVICE KITS AND CALIBRATION NOTES

Tri-Tech Medical Inc.

2 CYLINDER MOBILE CART USER S MANUAL / INSTRUCTIONS

Fabius Tiro TM. Designed for your environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

I. Subject: Medical Gas Systems Utility Failure Interim Procedure III. Purpose:

AUTOMATIC GAS MANIFOLDS

45A, Armthorpe Road, Brampton, Ontario, Canada, L6T 5M4. Made in Canada by O-Two Medical Technologies Inc.

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

BASIC PHYSICS APPLIED TO ANAESTHESIOLOGY

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% USER ADMINISTRATION SYSTEM 01EQ7000E DEMAND VALVE 01EQ7001E TABLE OF CONTENTS

Technical Information

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Sizing Pulsation Dampeners Is Critical to Effectiveness

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

Service Manual. Anesthesia System ANESTHESIA S ANESTHESIA SYSTEM

Anesthesia Delivery Systems What Do I Need to Know About My Machine? A Workshop James H. Philip, MEE, MD, CCE

MicroVent 1 Dual Mode Veterinary Ventilator IPPV / HFOV

Anesthesia. Midmark Animal Health Products

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

Dialflow Regulator. Instructions for Use

FUNDAMENTALS OF PRESSURE REGULATORS ROBERT BENNETT MANAGER OF TRAINING ELSTER AMERICAN METER

MACS Mask CPAP System

INTEGRUSPSV ANAESTHESIA WORKSTATION USER MANUAL

DESCRIPTION AND OPERATION OXYGEN SYSTEM OXYGEN SYSTEM

DRAFT U S E R M A N U A L CAUTION. Model: 19MFA1001 Series. Federal (USA) law restricts this device to sale by or on the order of a physician.

Testing anaesthetic machines, ventilators and related equipment

SIGNET 615 ANAESTHESIA WORKSTATION USER MANUAL

NARKOVET ANAESTHETIC UNIT

GE Healthcare. Avance Carestation. Upgrade promotions guide

STANDARD FLOWMETER USER S MANUAL

Prima SP Anaesthetic Machine Range Service Manual

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

INTENDED USE TECHNICAL SPECIFICATIONS

Chlorinator MODEL MK-I

Inert Air (N2) Systems Manual

Presence PR, PRC & PRE

Technical Data and Specifications

Statement. Aeonmed have the rights to replace any content in this manual without notice.

A9600 Anesthesia Workstation. Your healthcare, we care.

CAPITAL CONTROLS SERIES NXT3000

Narkomed M Anesthesia System Part No

Transcription:

Introductory Lecture Series: The Anesthesia Machine PORNSIRI WANNADILOK Objectives Anesthesia Machine Ventilators Scavenging Systems System Checkout 1

Flow meter ventilator bellow vaporizer Corrugated tube APL valve Soda lime Scavenging system The Anesthesia Machine High Intermediate Low Pressure Circuit 2

High Pressure System Receives gasses from the high pressure E cylinders attached to the back of the anesthesia machine (2200 psig for O2, 745 psig for N2O) Consists of: Hanger Yolk (reserve gas cylinder holder) Check valve (prevent reverse flow of gas) Cylinder Pressure Indicator (Gauge) Pressure Reducing Device (Regulator) Usually not used, unless pipeline gas supply is off E Size Compressed Gas Cylinders Cylinder Characteristics Color State Oxygen White (green) Gas Nitrous Oxide Blue Liquid and gas Carbon Dioxide Gray Liquid and gas Air Black/White (yellow) Gas Contents (L) 625 1590 1590 625 Empty Weight (kg) 5.90 5.90 5.90 5.90 Full Weight (kg) 6.76 8.80 8.90 Pressure Full (psig) 2000 750 838 1800 3

Hanger Yolk Hanger Yolk: orients and supports the cylinder, providing a gas-tight seal and ensuring a unidirectional gas flow into the machine Index pins: Pin Index Safety System (PISS) is gas specificprevents accidental rearrangement of cylinders (e.g.. switching O2 and N2O) Pressure Reducing Device Reduces the high and variable pressures found in a cylinder to a lower and more constant pressure found in the anesthesia machine (45 psig) Reducing devices are preset so that the machine uses only gas from the pipeline (wall gas), when the pipeline inlet pressure is 50 psig. This prevents gas use from the cylinder even if the cylinder is left open (i.e. saves the cylinder for backup if the wall gas pipeline fails) 4

Pressure Reducing Device Cylinders should be kept closed routinely. Otherwise, if the wall gas fails, the machine will automatically switch to the cylinder supply without the anesthetist being aware that the wall supply has failed (until the cylinder is empty too). Intermediate Pressure System Receives gasses from the regulator or the hospital pipeline at pressures of 40-55 psig Consists of: Pipeline inlet connections Pipeline pressure indicators Piping Gas power outlet Master switch Oxygen pressure failure devices Oxygen flush Additional reducing devices Flow control valves 5

Pipeline Inlet Connections Mandatory N2O and O2, usually have air and suction too Inlets are non- interchangeable due to specific threading as per the Diameter Index Safety System (DISS) Each inlet must contain a check valve to prevent reverse flow (similar to the cylinder yolk) Oxygen Pressure Failure Devices Machine standard requires that an anesthesia machine be designed so that whenever the oxygen supply pressure is reduced below normal, the oxygen concentration at the common gas outlet does not fall below 19% 6

Oxygen Pressure Failure Devices A Fail-Safe valve is present in the gas line supplying each of the flowmeters except O2. This valve is controlled by the O2 supply pressure and shuts off or proportionately decreases the supply pressure of all other gasses as the O2 supply pressure decreases Historically there are 2 kinds of fail-safe valves Pressure sensor shut-off valve (Ohmeda) Oxygen failure protection device (Drager) Pressure Sensor Shut-Off Valve Oxygen supply pressure opens the valve as long as it is above a pre-set minimum value (e.g.. 20 psig). If the oxygen supply pressure falls below the threshold value the valve closes and the gas in that limb (e.g.. N2O), does not advance to its flow-control valve. 7

Oxygen Failure Protection Device (OFPD) Based on a proportioning principle rather than a shut-off principle The pressure of all gases controlled by the OFPD will decrease proportionately with the oxygen pressure Oxygen Supply Failure Alarm The machine standard specifies that whenever the oxygen supply pressure falls below a manufacturer-specified threshold (usually 30 psig) a medium priority alarm shall blow within 5 seconds. 8

Limitations of Fail-Safe Devices/Alarms Fail-safe valves do not prevent administration of a hypoxic mixture because they depend on pressure and not flow. These devices do not prevent hypoxia from accidents such as pipeline crossovers or a cylinder containing the wrong gas Limitations of Fail-Safe Devices/Alarms These devices prevent hypoxia from some problems occurring upstream in the machine circuitry (disconnected oxygen hose, low oxygen pressure in the pipeline and depletion of the oxygen cylinder) Equipment problems that occur downstream (for example leaks or partial closure of the oxygen flow control valve) are not prevented by these devices. 9

Oxygen Flush Valve (O2+) Receives O2 from pipeline inlet or cylinder reducing device and directs high, unmetered flow directly to the common gas outlet (downstream of the vaporizer) Machine standard requires that the flow be between 35 and 75 L/min The ability to provide jet ventilation Hazards May cause barotrauma Dilution of inhaled anesthetic Second-Stage Stage Reducing Device Located just upstream of the flow control valves Receives gas from the pipeline inlet or the cylinder reducing device and reduces it further to 26 psig for N2O and 14 psig for O2 Purpose is to eliminate fluctuations in pressure supplied to the flow indicators caused by fluctuations in pipeline pressure 10

Low Pressure System Extends from the flow control valves to the common gas outlet Consists of: Flow meters Vaporizer mounting device Check valve Common gas outlet Flowmeter assembly When the flow control valve is opened the gas enters at the bottom and flows up the tube elevating the indicator The indicator floats freely at a point where the downward force on it (gravity) equals the upward force caused by gas molecules hitting the bottom of the float 11

In the presence of a flowmeter leak (either at the O ring or the glass of the flow tube) a hypoxic mixture is less likely to occur if the O2 flowmeter is downstream of all other flowmeters In A and B a hypoxic mixture can result because a substantial portion of oxygen flow passes through the leak, and all nitrous oxide is directed to the common gas outlet * Note that a leak in the oxygen flowmeter tube can cause a hypoxic mixture, even when oxygen is located in the downstream position Proportioning Systems Arrangement of the Flow- Indicator Tubes Mechanical integration of the N2O and O2 flow- control valves Automatically intercedes to maintain a minimum 25% concentration of oxygen with a maximum N2O:O2 ratio of 3:1 12

Limitations of Proportioning Systems Machines equipped with proportioning systems can still deliver a hypoxic mixture under the following conditions: Wrong supply gas Defective pneumatics or mechanics (e.g.. The Link-25 depends on a properly functioning second stage regulator) Leak downstream (e.g.. Broken oxygen flow tube) Inert gas administration: Proportioning systems generally link only N2O and O2 Vaporizers A vaporizer is an instrument designed to change a liquid anesthetic agent into its vapor and add a controlled amount of this vapor to the fresh gas flow 13

Classification of Vaporizers Methods of regulating output concentration Concentration calibrated (e.g. variable bypass) Measured flow Method of vaporization Flow-overover Bubble through Injection Temperature compensation Thermocompensation Supplied heat Generic Bypass Vaporizer Flow from the flowmeters enters the inlet of the vaporizer The function of the concentration control valve is to regulate the amount of flow through the bypass and vaporizing chambers Splitting Ratio = flow though vaporizing chamber/flow through bypass chamber 14

Factors That Influence Vaporizer Output Flow Rate: : The output of the vaporizer is generally less than the dial setting at very low (< 200 ml/min) or very high (> 15 L/min) flows Temperature: : Automatic temperature compensating mechanisms in bypass chambers maintain a constant vaporizer output with varying temperatures Back Pressure: : Intermittent back pressure (e.g. positive pressure ventilation causes a higher vaporizer output than the dial setting) Factors That Influence Vaporizer Output Atmospheric Pressure: : Changes in atmospheric pressure affect variable bypass vaporizer output as measured by volume % concentration, but not (or very little) as measured by partial pressure (lowering atmospheric pressure increases volume % concentration and vice versa) Carrier Gas: : Vaporizers are calibrated for 100% oxygen. Carrier gases other than this result in decreased vaporizer output. 15

The Circuit: Circle System Arrangement is variable, but to prevent re-breathing of CO2, the following rules must be followed: Unidirectional valves between the patient and the reservoir bag Fresh-gas-flow cannot enter the circuit between the expiratory valve and the patient Adjustable pressure- limiting valve (APL) cannot be located between the patient and the inspiratory valve Circle System Advantages: Relative stability of inspired concentration Conservation of respiratory moisture and heat Prevention of operating room pollution PaCO2 depends only on ventilation, not fresh gas flow Low fresh gas flows can be used Disadvantages: Complex design = potential for malfunction High resistance (multiple one-way valves) = higher work of breathing 16

The Adjustable Pressure Limiting (APL) Valve User adjustable valve that releases gases to the scavenging system and is intended to provide control of the pressure in the breathing system Bag-mask Ventilation: : Valve is usually left partially open. During inspiration the bag is squeezed pushing gas into the inspiratory limb until the pressure relief is reached, opening the APL valve. Mechanical Ventilation: : The APL valve is excluded from the circuit when the selector switch is changed from manual to automatic ventilation Scavenging Systems Protects the breathing circuit or ventilator from excessive positive or negative pressure. 17

Scavenging Systems Checking Anesthesia Machines 8 Categories of check: Emergency ventilation equipment High-Pressure system Low-Pressure system Scavenging system Breathing system Manual and automatic ventilation system Monitors Final Position 18

The end 19