To Study the Effects of Design Parameters on Vortex Tube with CFD Analysis

Similar documents
Effect of Hot End Obstruction and Nozzle on the Performance of Vortex Tube

Performance Improvement of Ranque-Hilsch Vortex Tube by Varying inside Surface Roughness of Hot Tube

A. M. Dalavi, Mahesh Jadhav, Yasin Shaikh, Avinash Patil (Department of Mechanical Engineering, Symbiosis Institute of Technology, India)

Modeling and Investigation of Change in Working Parameters on the Performance of the Vortex Tube with CFD Analysis

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

Development of Two Opposing Nozzle Vortex Tube Using Air as Working Fluid

FABRICATION AND OPTIMIZATION OF PERFORMANCE OF VORTEX TUBE PARAMETERS

An Experimental Performance Study of Vortex Tube Refrigeration System

DEVELOPMENT OF TWO OPPOSING NOZZLE VORTEX TUBE USING AIR AS WORKING FLUID

EXPERIMENTAL PERFORMANCE ANALYSIS OF VORTEX TUBE FOR VARIOUS PARAMETERS

An Efficient Vortex Tube With Max C.O.P

COMPUTATIONAL FLUID DYNAMICS ANALYSIS OF HELICAL NOZZLES EFFECTS ON THE ENERGY SEPARATION IN A VORTEX TUBE

An Experimental Investigation of the Optimum Geometry for Energy Separation of the Ranque- Hilsch Vortex Tube

Effect of Cold Fraction and Orifice Diameter on the Performance of Modified Vortex Tube with Dual Forced Vortex Flow

Experimental Investigation and Modification of Ranque Hilsch Vortex Tube

EXPERIMENTAL STUDY OF THE ENERGY SEPARATION IN COUNTER FLOW VORTEX TUBE

Fabrication and Experimental Analysis of a Vortex Tube Refrigeration system

OPTIMIZATION OF SINGLE STAGE AXIAL FLOW COMPRESSOR FOR DIFFERENT ROTATIONAL SPEED USING CFD

Effect of Inlet Clearance Gap on the Performance of an Industrial Centrifugal Blower with Parallel Wall Volute

A COMPARATIVE STUDY OF MIX FLOW PUMP IMPELLER CFD ANALYSIS AND EXPERIMENTAL DATA OF SUBMERSIBLE PUMP

COMPUTATIONAL FLOW MODEL OF WESTFALL'S LEADING TAB FLOW CONDITIONER AGM-09-R-08 Rev. B. By Kimbal A. Hall, PE

THE EFFECT OF L/D RATIO ON THE TEMPERATURE SEPARATION IN THE COUNTERFLOW VORTEX TUBE

DEVELOPMENT OF HIGH ALTITUDE TEST FACILITY FOR COLD JET SIMULATION

VORTEX TUBE COOLING SYSTEM

SIMULTANEOUS OPTIMIZATION OF HOT AND COLD OUTLET AIR TEMPERATURES OF VORTEX TUBE USING GREY RELATIONAL ANALYSIS AND TAGUCHI METHOD

A Numerical Study of the Performance of a Heat Exchanger for a Miniature Joule-Thomson Refrigerator

CFD Flow Analysis of a Refrigerant inside Adiabatic Capillary Tube

CFD Analysis ofwind Turbine Airfoil at Various Angles of Attack

MODELING AND SIMULATION OF VALVE COEFFICIENTS AND CAVITATION CHARACTERISTICS IN A BALL VALVE

Two-way Fluid Structure Interaction (FSI) Analysis on the Suction Valve Dynamics of a Hermetic Reciprocating Compressor

CFD Analysis and Experimental Study on Impeller of Centrifugal Pump Alpeshkumar R Patel 1 Neeraj Dubey 2

Predicting the Suction Gas Superheating in Reciprocating Compressors

Computational fluid dynamics analysis of a mixed flow pump impeller

Numerical Simulation for the Internal Flow Analysis of the Linear Compressor with Improved Muffler

CFD Analysis of Supersonic Nozzle with Varying Divergent Profile

An Impeller Blade Analysis of Centrifugal Gas Compressor Using CFD

Single Phase Pressure Drop and Flow Distribution in Brazed Plate Heat Exchangers

Investigation on Divergent Exit Curvature Effect on Nozzle Pressure Ratio of Supersonic Convergent Divergent Nozzle

Investigation of Suction Process of Scroll Compressors

CFD ANALYSIS AND COMPARISON USING ANSYS AND STAR-CCM+ OF MODEL AEROFOIL SELIG 1223

Post Graduates, Department of Mechanical Engineering, King College of Technology, Namakkal, Tamil Nadu, India

CFD analysis & Experimental Investigation of Shell & Tube Type Heat Exchanger with modified Slotted Baffles

Investigation on 3-D Wing of commercial Aeroplane with Aerofoil NACA 2415 Using CFD Fluent

Fabrication and Experimental Analysis of Vortex Tube by Varying the Geometry and Material

Influence of rounding corners on unsteady flow and heat transfer around a square cylinder

Aerodynamics of Winglet: A Computational Fluid Dynamics Study Using Fluent

Research and optimization of intake restrictor for Formula SAE car engine

PERFORMANCE STUDY OF A MODIFIED RANQUE-HILSCH VORTEX TUBE

AIRFLOW GENERATION IN A TUNNEL USING A SACCARDO VENTILATION SYSTEM AGAINST THE BUOYANCY EFFECT PRODUCED BY A FIRE

Effect of Diameter on the Aerodynamics of Sepaktakraw Balls, A Computational Study

THEORETICAL EVALUATION OF FLOW THROUGH CENTRIFUGAL COMPRESSOR STAGE

AIR EJECTOR WITH A DIFFUSER THAT INCLUDES BOUNDARY LAYER SUCTION

ANALYSIS OF HEAT TRANSFER THROUGH EXTERNAL FINS USING CFD TOOL

Simulator For Performance Prediction Of Reciprocating Compressor Considering Various Losses

Modification and experimental research on vortex tube

Proceedings of the ASME th Biennial Conference on Engineering Systems Design and Analysis ESDA2014 June 25-27, 2014, Copenhagen, Denmark

Review of Ranque Hilsch effects in vortex tubes

Hermetic Compressor With Improved Motor Cooling

OPTIMIZATION OF RECUPERATER FIN GEOMETRY FOR MICRO GAS TURBINE

Application of Computational Fluid Dynamics to Compressor Efficiency Improvement

ANALYSIS OF AERODYNAMIC CHARACTERISTICS OF A SUPERCRITICAL AIRFOIL FOR LOW SPEED AIRCRAFT

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

An Investigation on the Performance Characteristics of a Centrifugal Compressor

The Mechanism Study of Vortex Tools Drainage Gas Recovery of Gas Well

ISSN (Print) : Wasan Naksanee et al. / International Journal of Engineering and Technology (IJET)

OPTIMIZING THE LENGTH OF AIR SUPPLY DUCT IN CROSS CONNECTIONS OF GOTTHARD BASE TUNNEL. Rehan Yousaf 1, Oliver Scherer 1

Experimental Investigation of Vortex Tube Refrigeration

Návrh vratného kanálu u dvoustupňového kompresoru Return channel design of the two stage compressor

Purdue e-pubs. Purdue University. Stephan Lehr Technische Universitaet Dresden. Follow this and additional works at:

HYDROGEN FAST FILLING TO A TYPE IV TANK DEVELOPED FOR MOTORCYCLES

Influence of Ambient Temperature on Performance of a Joule-Thomson Refrigerator

A Numerical Simulation of Fluid-Structure Interaction for Refrigerator Compressors Suction and Exhaust System Performance Analysis

Applied Fluid Mechanics

Optimization of Ejector's Performance With a CFD Analysis. Amanda Mattos Karolline Ropelato Ricardo Medronho

CFD Simulation and Experimental Validation of a Diaphragm Pressure Wave Generator

Improvement of the Volumetric and Isentropic Efficiency Due to Modifications of the Suction Chamber

The Effect of Impeller Width on the Location of BEP in a Centrifugal Pump

CFD ANALYSIS TO INVESTIGATE THE EFFECT OF AXIAL SPACING IN A SINGLE STAGE TRANSONIC AXIAL FLOW COMPRESSOR

Design & Analysis of Natural Laminar Flow Supercritical Aerofoil for Increasing L/D Ratio Using Gurney Flap

Copyright by Turbomachinery Laboratory, Texas A&M University

COMPUTATIONAL FLUID DYNAMIC ANALYSIS OF AIRFOIL NACA0015

AERODYNAMIC CHARACTERISTICS OF NACA 0012 AIRFOIL SECTION AT DIFFERENT ANGLES OF ATTACK

Wind tunnel effects on wingtip vortices

Design and Numerical Flow Analysis of Expansion Deflection Nozzle

Computational Analysis of Cavity Effect over Aircraft Wing

NUMERICAL INVESTIGATION OF PRESSURE DROP IN HYDRAULIC SPOOL VALVE

Study on the Influencing Factors of Gas Mixing Length in Nitrogen Displacement of Gas Pipeline Kun Huang 1,a Yan Xian 2,b Kunrong Shen 3,c

CFD analysis of flow through mixed flow compressor under various operating conditions

AIRFOIL PROFILE OPTIMIZATION OF AN AIR SUCTION EQUIPMENT WITH AN AIR DUCT

Vortex Tube Short Course February 2017

Flow and Heat Transfer Characteristics Over a NACA0018 Aerofoil and a Test Aerofoil A Comparative Study

Influencing Factors Study of the Variable Speed Scroll Compressor with EVI Technology

Journal of Engineering Science and Technology Review 9 (5) (2016) Research Article. CFD Simulations of Flow Around Octagonal Shaped Structures

Study of Secondary Flow Modifications at Impeller Exit of a Centrifugal Compressor

Figure 1 Schematic of opposing air bearing concept

Numerical Fluid Analysis of a Variable Geometry Compressor for Use in a Turbocharger

Efficiency Improvement of Rotary Compressor by Improving the Discharge path through Simulation

A review on design criteria for vortex tubes

EXPERIMENTAL ANALYSIS OF FIN TUBE AND BARE TUBE TYPE TUBE-IN-TUBE HEAT EXCHANGER

Computational Analysis of the S Airfoil Aerodynamic Performance

Transcription:

To Study the Effects of Design Parameters on Vortex Tube with CFD Analysis Akash S. Bidwaik Assistant Professor, Department of Mechanical Engineering, SIES Graduate School of Technology, Nerul, Maharashtra, India Abstract- The present work is focused on the design of vortex tube with dc = 5, 6, 7 mm. The investigation is carried out with double inlet vortex tube to increase the intensity of swirl by using vortex generator with eight tangential nozzle with L/D = 11.5. The experimental data and analytical values were meticulously recorded and presented in the paper in a lucid form. Numerical analysis was carried out to analyze the behavior of the fluid inside the vortex tube by using different geometrical and thermo physical parameters. The governing equations have been solved using ANSYS FLUENT 15.0 using a 3D model on a fluid domain. The design has proved to be a paragon in itself. Keywords: - Vortex tube, thermo physical parameters, geometrical parameters I. INTRODUCTION Vortex tube is a device which uses air as refrigerating fluid, since air is abundantly available in nature hence vortex tubes proves to be inexpensive and unhazardous to nature. The vortex tube is a structurally simple device with no moving parts that is capable of separating a high pressure flow into two lower pressure flows with different energies, usually manifested as a difference in temperatures. The schematic diagram of vortex tube is shown in the Fig. 1.1. It consists of vortex chamber, vortex generator, nozzle, hot air side, cold air side, cone valve. Compressed air (5 to 8 bar) is passed through the nozzle. It is injected into the vortex tube. High-pressure gas enters the tube through tangential nozzles. Here, air expands and acquires high velocity due to particular shape of the nozzle. A vortex flow is generated inside the chamber and air travels in spiral like motion along the periphery of the hot side.. Figure1.1: Working of vortex tube This flow is restricted by the valve. When the pressure of the air near valve is made more than outside by partly closing the valve, a reversed axial flow through the core of Sumit Mukund Dhavale Student (BE), Department of Mechanical Engineering, SIES Graduate School of Technology, Nerul, Maharashtra, India the hot side starts from high-pressure region to lowpressure region. As the vortex moves along the tube, a temperature separation is formed. Hot air moves along the tube periphery, and cold air is in motion in the inner core. The hot air is then allowed to exit through the cone valve at the far end of the tube, while the cold air outlet is next to the inlet plane. During this process, heat transfer takes place between reversed stream and forward stream. Therefore, air stream through the core gets cooled below the inlet temperature of the air in the vortex tube, while air stream in forward direction gets heated up. Colder, lowpressure gas leaves via an orifice near the centerline adjacent to the plane of the nozzles and warmer, lowpressure gas leaves near the periphery at the end of the tube opposite the nozzles. The cold stream is escaped through the diaphragm hole into the cold side, while hot stream is passed through the opening of the valve. By controlling the opening of the valve, the quantity of the cold air and its temperature can be varied. The principle is said to have been discovered by Rudolf Hilsch (1), German physicist in 1945, took further the challenge to complete the obscured work of George Ranque (1), who first invented the vortex in 1928 but failed to exploit its usage commercially. Using the tube with insulation to reduce energy loss to surroundings gave a higher temperature separation in the tube than that without insulation around 2-3 0 C for the cold tube and 2-5 0 C for the hot tube. The increase of the number of inlet nozzles led to higher temperature separation in the vortex tube was advocated by Pongjet Promvonge and Smith Eiamsa-ard (2). A feasibility study of vortex tube was presented by Don Van (3) to infer the use of vortex tube as an airconditioning device on commercial scale. Nader Pourmahmoud (4) noticed that helical nozzle created more swirl velocity in vortex chamber than the straight chamber using numerical and experimental analysis. D.D. Pawar, B. Sridhar Babu (5) were found that increasing inlet nozzle number, inlet pressure and decreasing the cold air orifice diameter up to dc = 5 mm, decreases the cold end temperature of the vortex tube. A numerical study was performed on Ranque-Hilsch vortex tubes (RHVT) by Bramo, A. R., Pourmahmoud N (6), with length to diameter ratios (L/D) of 8, 9.3, 10.5, 20.2, 30.7 and 35 with 90

six straight nozzles was investigated. It was found that the best performance was obtained when the ratio of vortex tube length to the diameter was 9.3. Chang K., Li Qing, Zhou G., Li Qiang (7), performed Experimentation with hot divergent tube and found that the Energy separation performance of vortex tube can be improved by using a divergent hot tube. Pongjet Promvonge and Smith Eiamsaard (8), the experimental results showed that the insulated vortex tube with 4 inlet nozzles and cold orifice diameter of 0.5D yielded the highest temperature reduction (temperature separation) and isentropic efficiency at about 30 0 C and 33% respectively. They bolster their research by following conclusions: 1. The increase of the number of inlet nozzles led to higher temperature separation in the vortex tube. 2. Using the tube with insulation to reduce energy loss to surroundings gave a higher temperature separation in the tube than that without insulation around 2-3 0 C for the cold tube and 2-5 0 C for the hot tube. 3. A small cold orifice (d/d=0.4) yielded higher backpressure while a large cold orifice (d/d=0.7, 0.8, and 0.9) allowed high tangential velocities into the cold tube, resulting in lower thermal/energy separation in the tube. Nian Li, Zheng Wang (9), did a comparative study on the temperature difference of the vortex tube using different working fluids (R134a, R744, R32 and R227), the specific heat ratio k, compressibility factor z, and kinetic viscosity ν are considered as the main factors affecting the temperature separation process in the vortex tube. Suraj S Raut (10) performed an experimental study on the behavior of counter-flow vortex tube and observed that the temperature drop increases with increase in inlet pressure for the optimum value of L/D ratio in range of 30-40. At 10 bar Inlet pressure, 40 L/D ratio and 0.6 Cold mass fraction gave the best results was cited by him. A series of experiments have been conducted by Mohammad O. Hamdan, Basel Alsayyed, Emad Elnajjar (11) to investigate the performance of the vortex tube under several design parameters mainly: inlet pressure, cold mass fraction, Number of inlet nozzles, vortex stopper location, Nozzle inlet angle, and nozzles arrangements which stated the change in the COP is clearly seen for nozzles angle greater than 30 degree. An experimental evaluation was done on vortex tube by P K Singh, R G Tathgir (12), Length of the tube has no effect on the performance of the tube when it is increased beyond 45mm up to 55mm diameter of tube. A numerical analysis has been carried out by for N. Pourmahmoud, A. Jahangiramini, A. Izadi (13) for the turbulent flow structure inside vortex tube with standard k ε turbulence model, with the axial angle of β = 4 operates the best condition from cooling point of view and axial angle with β=8 has maximum heating efficiency was observed. R. S. Maurya and Kunal Y. Bhavsar (14) predicted the flow structure and thermal profile by performing numerical investigation on a six nozzle vortex tube and explain important features and reasons reason behind flow and energy separation occurring in vortex tube. Most significant outcomes were: (i) Energy separation is most effective close to cold orifice where L/D ratio is less than 10. (ii) Cold orifice to shell diameter ratio must be close to 0.583. (iii) Tube wall temperature and tube wall heat flux does not influence cold exit temperature. Additional energy is carried away by hot air only. R.Madhu Kumar, V.Nageswar Reddy, B. Dinesh Babu (15) experimentally suggested the use of conical hot tube for improving the performance of Ranque-Hilsch Vortex Tube. The COP of the vortex tube increases with increase in inlet pressure, they found that with conical angle of 2 to 3 the COP of the conical hot tube was increased upto 35.96%. II. DESIGN APPROACH A. Design Designing criteria of the vortex tube is based upon the following condition: 1. Ambient pressure (Pa) 2. Inlet pressure (Pi) 3. Inlet temperature (Ti) 4. Cooling temperature (Tc) 5. Temperature of hot body (Th) Considering the above conditions with respect to the various application of the vortex tube, the following designing parameters need to be selected: 1. Diameter of hot tube (D) 2. Length of hot tube (L) 3. Cold orifice diameter (dc) Present design is purely based on empirical relation supported with standard key geometry such as cold orifice diameter (dc= 5 mm, 6 mm, 7 mm). The system is design for supply pressure more than 5 bars. dc D = 0.5 The cold orifice diameter dc is selected as 6 mm for better cooling effect. Therefore tube diameter D = 12 mm. Design parameter: L D = 11.5 Length of the tube L = 138mm The design parameters are decided for optimum results on basis of literature survey. Investigation was done by using vortex generator with 8 inlet tangential nozzles and also based on different orifice diameters such as, dc = 5mm, 6mm, 7mm Material selected for vortex tube was stainless steel and brass for vortex generator. 91

B.CAD Model: A reciprocating type air compressor of 6 HP with supply pressure of 5, 6, and 7 bar respectively is used to supply compressed air to the double inlet vortex tube. The temperature of the inlet air, cold side air and hot side air was measured with the help of calibrated thermocouples with an accuracy of ±1ᵒC. A Vane type anemometer was used to determined velocity of air on hot side as well as cold side. The mass flow rate of the air is divided by using T- Joint. IV.RESULTS AND DISCUSSION Case 1: Effect of variation of inlet pressure on temperature drop for double inlet vortex tube with different cold orifice diameter dc=5 dc=6 dc=7 Fig2.1: Vortex generator with 8 tangential nozzles 21 ΔTc 20 19 18 17 16 15 5 6 7 Inlet Pressure (bar) Fig4.1: Effect of variation of inlet pressure on temperature drop for double inlet vortex tube with different cold orifice diameter Fig2.2: Vortex tube with double inlet (Front view) III. EXPERIMENTAL SET-UP From figure 4.1 it is clearly seen that as the inlet pressure is increased the cold side temperature drop also increases due to increase in radial velocity of air inside the vortex tube. The maximum temperature drop was found to be ΔTc=20.2 C for dc=7mm at 7 bar pressure. T- Joint Case 2: Effect of variation of inlet pressure on cold mass friction for double inlet vortex tube with different cold orifice diameter It is clearly seen from figure 4.2 that as the inlet pressure is increased the cold mass fraction also increases due to increase in mass flow rate of cold air at the cold outlet for different orifice diameter vortex generator. The highest value of Cold mass fraction was found to be μ=0.29 for dc=7 mm with eight tangential nozzle. Fig3.1: Experimental setup. 92

μ 0.72 0.62 0.52 0.42 0.32 0.22 0.12 0.02 dc=5 dc=6 dc=7 5 6 7 Inlet Pressure (bar) 1. Preprocessing In this very first stage of numerical analysis a solid model of vortex tube was created, using Creo Parametric 2.0 as modelling software and an unstructured triangular mesh was created using ANSYS ICEM with 0.9 mm as element size. Fig 4.2: Effect of variation of inlet pressure on cold mass friction for double inlet vortex tube with different cold orifice diameter Case 3: Effect of variation of inlet pressure on COP for double inlet vortex tube with different cold orifice diameter COP 0.12 0.115 0.11 0.105 0.1 0.095 0.09 0.085 0.08 0.075 0.07 dc=5 dc=6 dc=7 5 6 7 Inlet Pressure (bar) Fig 4.4: solid model of vortex tube 2. Processing or Solving The solver uses a three dimensional steady, compressible pressure based SIMPLE scheme with second-order upwind scheme for convective terms and standard k ε model to capture turbulence. Ideal gas equation has been activated to capture temperature redistribution occurring due to energy separation. Fig 4.3: Effect of variation of inlet pressure on COP for double inlet vortex tube with different cold orifice diameter From figure 4.3 it is clearly seen that as the inlet pressure is increased the Coefficient of performance also increases due to increase in temperature drop at the cold outlet for different orifice diameter vortex generator. The highest value of Coefficient of Performance was found to be 0.126 for dc=7 mm with eight tangential nozzle. The numerical analysis was carried out to compare the above results A. Numerical analysis: ANSYS Fluent 15.0 was used as finite volume based solver, for solving the governing equation and implementing the boundary conditions. For solving numerical problems through CFD the common procedure followed is. Fig 4.5: unstructured triangular mesh 3. Post-processing Post-processing is interpretation and visualization of simulation results. During post processing the mass and heat imbalances are checked for physical soundness of the simulated results. Hence, various visualization techniques such as, Contour plots, Streamline plots, Vector plots, X-Y plots are used for further analysis. Post processing was done with help of Fluent 12.0, CFX, Ansys CFD-Post, etc. 93

Fig4.6: Total pressure contour Fig 4.8: Total temperature contour Fig 4.8 and 4.9 shows the distribution of temperature of air inside the tube. The temperature distribution is presented on a cutting plane along the tube length. A cooled plume can be seen to concentrate in a small region near the cold side orifice. The hot air occupies the peripheral part of the tube which is actually the outer vortex that carries away heat from the inner stream and cools it. Cold air gets slowly heated while travelling through the diverging cold exit. Fig 4.7: Total pressure contour along tube length cutting plane. Fig 4.6 and 4.7 shows the expansion of supplied air leading to energy separation. The pressure distribution is presented on a cutting plane along the tube length. A difference in pressure gradient in axial and radial direction of flow can be observed. The result shows that radial pressure gradient is higher than the axial pressure. Large pressure gradient leads to quick expansion and faster cooling of the medium. Fig 4.9: Total temperature contour along tube length cutting plane. 94

The CFD analysis on the vortex tube helped in understanding the nature of flow of air inside the vortex tube and the energy separation mechanism. A new approach for optimizing the design of the vortex tube can be done by using CFD analysis and the flow structure developed is easy to understand. The results of CFD analysis and the experimental value was closely validated. The result obtain from the analysis gave a close difference between the experimental and numerical method which is given as follows. Table: Comparison between experimental and numerically obtained values. Model Experimental Numerical Double Inlet 8 tangential nozzles Tc (ᵒ C) Th(ᵒ C) Tc (ᵒ C) Th (ᵒ C) 12.8 39.1 14.2 38.6 V. CONCLUSION The experimental results shows that the temperature drop is directly depended on intensity of inlet pressure, as the inlet pressure is increased the more temperature drop is obtained at the cold exit. It is also observed that the hot side control valve regulates the temperature drop on cold side by adjusting the flow rate at the hot end. Increasing the number of tangential nozzle causes more turbulent flow inside the tube due to which the energy separation between the two vortices inside the tube was. This concluded that for increased in number of tangential nozzle on vortex generators the ratio of L/D ratio should be greater than 11.5. The generator with orifice diameter 7mm provide the best result for double inlet vortex tube. The design of critical parameters like length to diameter ratio (L/D), number of tangential nozzles, orifice diameter (dc) can be effectively done by CFD techniques and performance of the vortex tube can be increased. The experimental results were validated using CFD analysis, readings obtained were with least deviation ranging from (3.7%-10%). The lowest temperature obtained experimentally for double inlet vortex tube with eight tangential nozzle for cold orifice diameter (dc=7mm) was about 12.80 C. The highest temperature obtained experimentally for double inlet vortex tube with eight tangential nozzle at hot side was about 39.10 C. The present designed vortex tube can be used at medical laboratories for cooling medical samples. The hot air can be used for drying purposes in industries. VI. REFRENCES [1] Ranque GJ (1933) Experiments on expansion in a vortex with simultaneous exhaust of hot air and cold air. J Phys Radium (Paris) 4:112-114, June. Also translated as General Electric Co., Schenectady Works Library 1947; T.F 32941. Hilsch R (1947) the use of expansion of gases in a centrifugal field as cooling process. Rev Sci instrum 18(2):108-113. [2] Promvonge P, Eiamsa-ard S (2005) Investigation on the vortex thermal separation in a vortex tube refrigerator. Sci Asia J 31(3):215 223. Eiamsa-ard S, Promvonge P (2006) Numerical prediction ofvortex flow and thermal separation in a subsonic vortex tube. J Zhejiang Univ SCI Int Appl Phys Eng J 7(8):1406 1415.C. [3] Don Van, Joel Ingram, Kenneth Mayo and Kian Jost Process Analyzing of the Vortex Tube and The Teaching and Learning of Energy Efficiency and Sustainability, 2013 ASEE Southeast Section Conference. [4] Pourmahmoud, Amir hassan zadeh, Omid moutaby, and Abdolreza bramo N., et al.: Computational Fluid Dynamics Analysis of Helical Nozzles Effects on the energy separation in a vortex tube, THERMAL SCIENCE, Year 2012, Vol. 16, No. 1, pp. 151-166. ISSN: 2319-8753 [5] D.D Pawar, B. Sridhar Babu, Computational Fluid Dynamics and Experimental Analysis for Optimum Geometry of Vortex Tube International Journal of Innovative Research in Science, Engineering and Technology (An ISO 3297: 2007 Certified Organization) Vol. 3, Issue 8, August 2014 DOI: 10.15680/IJIRSET.2014.0308067. [6] Bramo, A. R. and Pourmahmoud, N., "Computational fluid dynamics simulation of length to diameter ratio effects on the energy separation in a vortex tube", Thermal Science, Vol. 15, No. 3, (2011), 833-848. [7] Chang K., Li Qing, Zhou G., Li Qiang, Experimental Investigation of Vortex Tube Refrigerator with a Divergent Hot tube, International Journal of Refrigeration, 34, 2011, pp.322-327. [8] Pongjet Promvonge and Smith Eiamsa-ard, Investigation on the Vortex Thermal Separation in a Vortex Tube Refrigerator ScienceAsia 31 (2005): 215-223.doi: 10.2306/scienceasia1513-1874. [9] Nian Li, Zheng Wang, Xiaohong Han, Guangming Chen "Experimental study of the Couple Characteristics of the Refrigerants and Vortex Tube" (2014). International Refrigeration and Air Conditioning Conference. Paper 1518. [10] Suraj S Raut*, Dnyaneshwar N Gharge, Chetan D Bhimate, Mahesh A. Raut, S.A. Upalkar and P.P. Patunkar, An Experimental Modeling and Investigation of Change in Working Parameters on the Performance of Vortex Tube, International Journal of Advanced Mechanical Engineering.ISSN 2250-3234 Volume 4, Number 3 (2014), pp. 343-348 [11] Mohammad O. Hamdan, Basel Alsayyed, Emad Elnajjar, Nozzle parameters affecting vortex tube energy separation performance, Heat Mass Transfer DOI 10.1007/s00231-012-1099-2. [12] P. K. Singh, R. G. Tathgir, D. Gangacharyulu, and G. S. Grewal. An experimental performance evaluation of vortex tube. IE Journal -MC, 84 (2004), pp. 149 153. [13] B.sreenivasa kumar reddy, prof. K.govindarajulu, Air cooling in automobiles using vortex tube refrigeration system, B.Sreenivasa Kumar Reddy et al. / International Journal of Engineering Science and Technology (IJEST) ISSN : 0975-5462 Vol. 5 [14] N. Pourmahmoud, A. Jahangiramini, A. Izadi, Optimization of Low Pressure Vortex Tube via Different Axial Angles of Injection Nozzles, IJE TRANSACTIONS A: Basics Vol. 26, No. 10, (October2013)1255-1266 [15] R. S. Maurya and Kunal Y. Bhavsar, Energy and Flow Separation in the Vortex Tube: A Numerical Investigation, International Journal on Theoretical and Applied Research in Mechanical Engineering (IJTARME) ISSN: 2319 3182, Volume-2, Issue-3, 2013 [16] R.Madhu Kumar1, V.Nageswar Reddy, B. Dinesh Babu, Performance Improvement of Ranque-Hilsch Vortex Tube by Using Conical Hot Tube, International Journal of Engineering Research ISSN:2319-6890)(online),2347-5013(print) Volume No.3 Issue No: Special 1, pp: 48-51 22nd March 2014. 95