Technical Data Megacote

Similar documents
Property Test/Standard Description

Specially designed for maintenance and repair of dedicated water ballast tanks on vessels and offshore structures. Other

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 33 C calculated VOC-USA / VOC Hong Kong EPA Method 24

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 35 C calculated IED (2010/75/EU) (theoretical)

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 36 C calculated VOC-US/Hong Kong US EPA method 24 (tested)

Property Test/Standard Description

Property Test/Standard Description

Approved. Marine: Exterior areas, specially designed for outside hull, may be used on superstructure, decks and other external areas.

To be used as a coating for potable water tanks and pipes. Independently tested and certified for potable water storage. Other

Property Test/Standard Description

To be used as a coating for potable water tanks and pipes. Independently tested and certified for potable water storage. Other

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1 25 C

Approved. Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 28 C calculated VOC-US/Hong Kong

Property Test/Standard Description

Designed for both global and coastal trade. Recommended for exposure to both sea and fresh water during newbuilding outfitting. Antifouling.

Property Test/Standard Description

Property Test/Standard Description. 63± 2 % Gloss level (GU 60 ) ISO gloss (70-85) Flash point ISO 3679 Method 1 30 C

Property Test/Standard Description

Approved. Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1 55 C VOC-US/Hong Kong. US EPA method 24 (tested)

General: Primarily designed for maintenance and repair. In immersed environments Jotamastic 80 Aluminium is suitable.

Property Test/Standard Description

Can be used on helidecks, walkways, ramps, weigh bridge decks, decks in general where abrasion resistance and non-slip properties are required.

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1 36 C

aluminium, aluminium red toned, black, white and according to Multicolor Industry tinting system (MCI)

Date of issue: 20 April 2018 Page: 1/6

Before application, test the atmospheric conditions in the vicinity of the substrate for the dew formation according to ISO

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 35 C calculated IED (2010/75/EU) (theoretical)

Before application, test the atmospheric conditions in the vicinity of the substrate for the dew formation according to ISO

The Application Guide offers product details and recommended practices for the use of the product.

The Application Guide offers product details and recommended practices for the use of the product.

two component solvent free amine cured phenolic epoxy coating (1 g/cm³ = 8.25 lb/us gal; 1 m²/l = 40.7 ft²/us gal) (data for mixed product)

two component solvent free amine cured phenolic epoxy coating

Polidura Glossy PU Topcoat Component A: 6103 Component B: 6199

Two coats are normally recommended. Some service may require mils DFT

The Application Guide offers product details and recommended practices for the use of the product.

SIGMAGUARD CSF 575. PRODUCT DATA SHEET September 14, 2015 (Revision of September 14, 2015) DESCRIPTION

Specification. M/V Viggen Viggen Drydocking of 16. Oy Hempel (Finland) Ab Bertel Jungin aukio 5 FI Espoo Finland hempel.

Hardener: at least 24 months when stored cool and dry

DFT in excess of 8.0 mils per coat is not recommended.

Part of Group Assortment. Local availability subject to confirmation.

DP40 is a versatile 2K Epoxy Surfacer. It is light grey in colour, chromate-free and has good corrosion resistance over bare metal.

*Valid if manufactured at a certified location. Light Grey (0700), White (0800), and Light Blue (0100). Colors are unmatched

The Application Guide offers product details and recommended practices for the use of the product.

The Application Guide offers product details and recommended practices for the use of the product.

*RTS not recommended for immersion service. Do not exceed 10 mils in a single coat (without additives)

10P20-13 High Solids Primer

The Application Guide offers product details and recommended practices for the use of the product.

Technical Data Sheet PART A & PART B

Carboguard 893 PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. Cycloaliphatic Amine Epoxy

Aerodur 2111 Chrome Free Primer

S0200V. Product Data Sheet August Primecoat P FOR PROFESSIONAL USE ONLY. Product Description

As Supplied : 1.67 lbs/gal (200 g/l) Plasite Thinner #71 : 10% by volume 2.18 lbs/gal (261 g/l)

Self-priming. May be applied over most generic types of coatings.

PAC33NV Polyurethane Primer. Mix Ratio (by volume) 4359/3600 (Base) 5 parts 0701/9000 (Activator) 1 part 0477/9000 (Thinner) 3 parts

AMERCOAT 370. PRODUCT DATA SHEET June 16, 2016 (Revision of October 9, 2015) DESCRIPTION. Two-component, fast dry multi-purpose epoxy coating

PACKAGING: Component A W-THANE HBA CD (2,7 L) Component B W-THANE 5057 CD (0,9 L)

AkzoNobel Aerospace Coatings. Primerr. Product Group. Epoxy primer. Characteristics Product Information. resistance. Components * TR-114. permits.

PAC33 Polyurethane Primer. Mix Ratio (by volume) 4355/3600 (Base) 5 parts 0701/9000 (Activator) 1 part 0433/9000 (Thinner) 4-5 parts

Heresite VR-514 T E C H N I C A L D A T A S H E E T

APPLICATION GUIDE ECOSPEED FOR ALUMINIUM SURFACES

Part of Group Assortment. Local availability subject to confirmation.

5014 PU Surfacer. Highly flexible Water resistant Good fluid resistance including phosphate ester hydraulic fluids Transparent to ultrasound & radar

The Application Guide offers product details and recommended practices for the use of the product.

Imron 2.1 PR Polyurethane Primer

Imron Industrial Strength Ultra Low VOC Polyurethane Clear Reduced Gloss Modifications

PR219 Epoxy Primer Undercoat

Interzinc 22 Application Guidelines

TECHNICAL DATA SHEET CA7040. CA7040 HS CF Polyurethane Primer. Product Description. Components. Specifications. Surface Preparation and Pretreatment

TECHNICAL DATA SHEET PP404. PP404 Epoxide Primer. Product Description. Components. Specifications. Surface Preparation and Pretreatment

Desofill CA8620 HS PU Sanding Surfacer. CA8000B (Activator) CA8000C or CA8000C2 (Thinner)

EC75/C9071 Epoxy Clear Coat. EC75/C9071 (Base) ACT65 (Activator) 0.33 part (spray application)

CV117 Hydraulic Fluid Resistant PU Lacquer. ACT34 (Activator) NOTE: No thinner is required for brush application

EC96 HS Epoxy Topcoat. 1 part. ACT197 (Activator) near matt. 1 part

TECHNICAL DATA SHEET EC75. EC75 Epoxy Topcoat. Product Description. Components. Specifications

Epoxy Non-chromate Corrosion Inhibiting Primer. Alumigrip 4101P001 Alumigrip 4901 (CS4901) AkzoNobel Aerospace Coatings. Bombardier Hawker Beechcraft

Desothane CA8311 HS Polyurethane Topcoat Matt

High Solids, low VOC Excellent durability Excellent flexibility Wide range of mica particle size and surface effects available

Product Information D822

ProAir Clear LV 2 Pack

0TECHNICAL DATA SHEET

Super Koropon 515X333 fluid resistant primer is a chemical and solvent resistant epoxy coating used in areas exposed to hydraulic fluid.

Product Information D822

PR143 (ACT 149) Epoxy Primer

Compatible with Desothane HS topcoats Excellent adhesion and corrosion resistance Service temperature -54 C to 177 C (-65 F to 350 F)

Desoprime HS 533K004 Military Epoxy Polyamide Primer

PRODUCT DATA SHEET. Advanced Industrial Coatings 2.1 VOC Epoxy Primer AIP302 Gray, AIP303 White PERSONAL PROTECTION SURFACE PREPARATION

Application of Fillers

Advantages of ALEXIT BladeRep

Desoprime HS CA7422 Chrome-Free Epoxy Primer

5541/9000 UV Resistant Varnish Semi Gloss. 0701/9000 (Activator) 5541/9000 meets the requirements of : AIMS

NAVSEA REVIEWED ASTM F-718. If this product is to be applied as part of a coating system, all components of the system must be as listed on the QPL.

HR39/801 Heat Resistant Topcoat Matt Black. HR39/801 is a heat resistant topcoat suitable for interior and exterior use.

Desoprime HS CA7233 Military Epoxy Primer

PD100 White, PD200 Black Low VOC Acrylic Polyurethane Topcoat

PRO-TEX TRUCKBED LINER TECHNICAL DATA SHEET

Mix ratio (by volume): 513K009 (base component) (activator component)

Desobond CA100 A/B Adhesion Promoter

Intertherm 3070 Application Guidelines

Mix ratio (by volume): 519X303 (base component) 910X357 (activator component) 020X324 (thinner component)

Desothane HS CA8925 buffable stain resistant topcoats are high solids topcoats used to protect the exterior of an aircraft.

Transcription:

Technical Data Megacote Product description Megacote is a fast-curing abrasion resistant high solids two-component epoxy anticorrosive coating that will bond to a wide variety of substrates. Recommended use A multi-purpose epoxy primer for use on all areas (internal and external, above and below water) onboard top quality large yachts. Megacote will bond well to correctly prepared steel, aluminium, galvanised steel, GRP, gelcoat and wood. Suitable for osmosis prevention on GRP hulls when part of an approved Jotun system. For application in water ballast tanks at newbuilding stage in accordance with PSPC (IMO Res. MSC 82/W), see the "Application procedure for water ballast tanks - Megacote". Film thickness and spreading rate Minimum Maximum Typical Film thickness, dry (µm) 75 300 150 Film thickness, wet (µm) 105 415 215 Theoretical spreading rate (m²/l) 9,6 2,4 4,8 Comments For DFTs below 150 µm, thinner should be used Approvals B1 classification by Det Norske Veritas (DNV) for water ballast tanks. Megacote Page 1 of 5

Physical properties Colour Aluminium red toned, Off-white and grey Solids (vol %)* 72 ± 2 Flash point 35ºC ± 2 (Setaflash) VOC 2,17 lbs/gal (260 gms/ltr) USA-EPA Method 24 240 gms/ltr UK-PG6/23(97). Appendix 3 Gloss Gloss retention Water resistance Abrasion resistance Solvent resistance Chemical resistance Flexibility Semigloss Fair Good *Measured according to ISO 3233:1998 (E) Surface preparation All surfaces should be clean, dry and free from contamination. The surface should be assessed and treated in accordance with ISO 8504. Bare steel Cleanliness: Blast-cleaning to Sa 2½ (ISO-8501-1:2007). Power tool cleaning to min. St 2 (ISO 8501-1:2007) may be acceptable, subject to exposure conditions. Shopprimed steel Clean, dry and undamaged approved shopprimer. Coated surfaces Clean, dry and undamaged compatible primer. Please contact your local Jotun office for more information. Other surfaces For aluminium substrates: Grit blasting to roughen the surface (minimum surface profile: 40 microns), or grinding with high-quality abrasive pads, such as Scotchbrite pads by 3M company. After preparation, the aluminium should be coated before oxidisation occurs. The coating may be used on other substrates. Please contact your local Jotun office for more information. Condition during application The temperature of the substrate should be minimum -5 C and minimum 3 C above the dew point of the air, temperature and relative humidity measured in the vicinity of the substrate. Good ventilation is required in confined areas to ensure proper drying. Do not use heated air until the solvents have evaporated from the paint film to avoid surface drying and solvent entrapment. The coating should not be exposed to strain until cured. Megacote Page 2 of 5

Application methods Spray Brush Roller Use airless spray Recommended for stripe coating and small areas, care must be taken to achieve the specified dry film thickness. May be used for small areas but not recommended for first primer coat, however when using roller application care must be taken to apply sufficient material in order to achieve the specified dry film thickness. Application data Mixing ratio (volume) 3 :1 Mixing Induction time Pot life (23 C) 3 parts Comp. A (base) to be mixed thoroughly with 1 part Megacote, Comp. B (curing agent) 10 minutes. 1½ hours (reduced at higher temperatures) Thinner/Cleaner Jotun Thinner No. 17 Guiding data airless spray Pressure at nozzle 15 MPa (150 kp/cm², 2100 psi) Nozzle tip 0.43-0.79 mm (0.017-0.031") Spray angle 40-80 Filter Check to ensure that filters are clean. Drying time Drying times are generally related to air circulation, temperature, film thickness and number of coats, and will be affected correspondingly. The figures given in the table are typical with: * Good ventilation (Outdoor exposure or free circulation of air) * Typical film thickness * One coat on top of inert substrate Substrate temperature -5 C 0 C 5 C 10 C 23 C Surface dry 20 h 14 h 8 h 5 h 2,5 h Through dry 1 48 h 30 h 16 h 10 h 5 h Cured 21 d 14 d 10 d 7 d Dry to recoat, minimum 2 24 h 18 h 10 h 7 h 4 h Dry to recoat, maximum 3 Substrate temperature 40 C Surface dry 1 h Through dry 2 h Cured 3 d Dry to recoat, minimum 2 2 h Dry to recoat, maximum 3 1. The earliest time interval that it is possible to exert mechanical strain on the coating, i.e. walk on to recoat. Megacote Page 3 of 5

1. The earliest time interval for recoating with the same generic type of paint. Note that the paint film is not hard at this time and can not withstand mechanical strain. 2. Provided the surface is free from chalking and other contamination prior to application, there is normally no overcoating time limit with itself. Best intercoat adhesion occurs, however, when the subsequent coat is applied before preceding coat has cured. If the coating has been exposed to direct sunlight for some time, special attention must be paid to surface cleaning and mattening/removal of the surface layer in order to obtain good adhesion. 3. Megacote's maximum recoating interval with filler is the given curing time. If such period is exceeded, sanding with P120-P150 and solvent cleaning must be performed prior any filler is applied. The given data must be considered as guidelines only. The actual drying time/times before recoating may be shorter or longer, depending on film thickness, ventilation, humidity, underlying paint system, requirement for early handling and mechanical strength etc. A complete system can be described on a system sheet, where all parameters and special conditions could be included. Typical paint system 1) Above water hull and superstructure (aluminium or steel): Megacote aluminium red toned 1 x 125 µm (Dry Film Thickness) Megafiller 8000 µm (Dry Film Thickness) Megafiller Smooth 500 µm (Dry Film Thickness) Megaprimer Grey 1 x 125 µm (Dry Film Thickness) Megaprimer White 1 x 125 µm (Dry Film Thickness) Megaspeed Undercoat* 1 x 50 µm (Dry Film Thickness) Megagloss HG 3 x 20 µm ** (Dry Film Thickness) 2) Underwater Hull (aluminium or steel): Megacote aluminium red toned 1 x 125 µm (Dry Film Thickness) Megacote off-white 1 x 125 µm (Dry Film Thickness) Megasealer 1 x 125 µm (Dry Film Thickness) Megayacht Imperial Antifouling 2 x 150 µm (Dry Film Thickness) 3) Interior Exposed (for example engine room): Megacote aluminium red toned 1 x 90 µm (Dry Film Thickness) Megacote off-white 1 x 90 µm (Dry Film Thickness) TopGloss 1 x 50 µm (Dry Film Thickness) 4) Water ballast tanks: Megacote aluminium red toned 1 x 160 µm (Dry Film Thickness) Megacote off-white 1 x 160 µm (Dry Film Thickness) * A show-coat of Megagloss HG may be applied instead of Megaspeed Undercoat. Contact Jotun for more information. ** Three coats applied wet-on-wet. Other systems may be specified, depending on area of use Storage The product must be stored in accordance with national regulations. Storage conditions are to keep the containers in a dry, cool, well ventilated space and away from source of heat and ignition. Containers must be kept tightly closed. Handling Handle with care. Stir well before use. Megacote Page 4 of 5

Packing size 18 litre unit: 13.5 litres Comp. A (base) in a 20 litre container and 4.5 litres Megacote, Comp. B (curing agent) in a 5 litre container. 4 litre unit: 3 litres Comp. A (base) in a 5 litre container and 1 litre Megacote, Comp. B (curing agent) in a 1 litre container. Health and safety Please observe the precautionary notices displayed on the container. Use under well ventilated conditions. Do not breathe or inhale mist. Avoid skin contact. Spillage on the skin should immediately be removed with suitable cleanser, soap and water. Eyes should be well flushed with water and medical attention sought immediately. For detailed information on the health and safety hazards and precautions for use of this product, we refer to the Material Safety Data Sheet. DISCLAIMER The information in this data sheet is given to the best of our knowledge based on laboratory testing and practical experience. However, as the product can be used under conditions beyond our control, we can only guarantee the quality of the product itself. We also reserve the right to change the given data without notice. Minor product variations may be implemented in order to comply with local requirements. If there is any inconsistency in the text the English (UK) version will prevail. Jotun is a World Wide company with factories, sales offices and stocks in more than 50 countries. For your nearest local Jotun address please contact the nearest regional office or visit our website at www.jotun.com ISSUED 7 MAY 2013 BY JOTUN THIS DATA SHEET SUPERSEDES THOSE PREVIOUSLY ISSUED Megacote Page 5 of 5