SHAKING TABLE TESTS AND EFFECTIVE STRESS ANALYSES ON THE DYNAMIC BEHAVIOR OF WEDGED CAISSONS

Similar documents
MODEL SHAKE TABLE TEST ON THE SEISMIC PERFORMANCE OF GRAVITY TYPE QUAY WALL WITH DIFFERENT FOUNDATION GROUND PROPERTIES

New Reinforcing Technique for Mitigation of Earthquake-induced Failure of Breakwater

FRAGILITY CURVES FOR GRAVITY-TYPE QUAY WALLS BASED ON EFFECTIVE STRESS ANALYSES

A STUDY ON LIQUEFIED GROUND DISRUPTION EFFECTS ON LIQUID STORAGE TANK BEHAVIOR

Reinforced Soil Retaining Walls-Design and Construction

Title Tsunami during 2011 East Japan Eart. The final publication is available より本文ファイルは に公開.

Dynamic response of composite caissonpiles

Learn more at

Ground Failure Mechanism of Micoropiled-raft

Analysis of dilatometer test in calibration chamber

Application of pushover analysis in estimating seismic demands for large-span spatial structure

CHAPTER 113 Impact Loading and Dynamic Response of Caisson Breakwaters

Yasuyuki Hirose 1. Abstract

STUDY ON UPWARD MOVEMENT OF FINES FROM SANDY SEABED UNDER CYCLIC WATER PRESSURE CHANGE DUE TO WAVES

Prof. B V S Viswanadham, Department of Civil Engineering, IIT Bombay

PROPAGATION OF LONG-PERIOD WAVES INTO AN ESTUARY THROUGH A NARROW INLET

Behavior of Dry Dense Sand-Foundation System Acted upon by Impact Loads

Time Pressure Dispensing

Irrigation &Hydraulics Department lb / ft to kg/lit.

Application of Simulation Technology to Mitsubishi Air Lubrication System

Critical face pressure and backfill pressure in shield TBM tunneling on soft ground

Pressuremeters in Geotechnical Design

ESTIMATION OF LATERAL SPREAD OF A CAISSON TYPE QUAY CAUSED BY BACK FILL LIQUEFACTION

SOIL-STRUCTURE INTERACTION ANALYSIS OF THE MANHATTAN BRIDGE FOUNDATIONS

Tutorial. BOSfluids. Relief valve

CHAPTER 5: VACUUM TEST WITH VERTICAL DRAINS

The tensile capacity of suction caissons in sand under rapid loading

Available online at ScienceDirect. Procedia Engineering 112 (2015 ) 40 45

Wave Motion. interference destructive interferecne constructive interference in phase. out of phase standing wave antinodes resonant frequencies

APPLICATION OF PUSHOVER ANALYSIS ON EARTHQUAKE RESPONSE PREDICATION OF COMPLEX LARGE-SPAN STEEL STRUCTURES

Cubzac-les-Ponts Experimental Embankments on Soft Clay

REPORT GEO-TECHNICAL INVESTIGATION FOR THE PROPOSED BLOCK-7 SUB-STATION SY NO-225, NEAR RAYACHERLU VILLAGE

FLUID MECHANICS Time: 1 hour (ECE-301) Max. Marks :30

An integrated three-dimensional model of wave-induced pore pressure and effective stresses in a porous seabed: II. Breaking waves

Seismic performance of partially submerged R.C. caissons used in port structures

CENGRS GEOTECHNICA PVT. LTD. Job No Sheet No. 1

REPORT GEO-TECHNICAL INVESTIGATION FOR THE PROPOSED BLOCK-1 SUB-STATION SY NO-44, NEAR KYATAGANACHERLU VILLAGE

SEISMIC SHUTOFF CHARACTERISTICS OF INTELLIGENT GAS METERS FOR INDIVIDUAL CUSTOMERS IN JAPAN

Chapter 11 Waves. Waves transport energy without transporting matter. The intensity is the average power per unit area. It is measured in W/m 2.

Variation in Pressure in Liquid-Filled Plastic Film Bags Subjected to Drop Impact

WATER HYDRAULIC HIGH SPEED SOLENOID VALVE AND ITS APPLICATION

A CENTRIFUGE MODEL STUDY ON THE EFFECTS OF PILE INSTALLATION PROCESS ON SEISMIC BEHAVIOR OF PILED RAFT FOUNDATION FOR OIL STORAGE TANKS

SYSTEM IDENTIFICATION AND RESPONSE ANALYSIS OF RC HIGH-RISE BUILDINGS UNDER SUCCESSIVE EARTHQUAKES

Desaturating sand deposit by air injection for reducing liquefaction potential

Level 3 Cambridge Technical in Engineering 05822/05823/05824/05825/05873 Unit 3: Principles of mechanical engineering

CH 17 - MECHANICAL WAVES & SOUND. Sec Mechanical Waves

Mechanical Stabilisation for Permanent Roads

Non-Linear Seismic Analysis of Multi-Storey Building

SUPPORTING NOTES FOR THE EVALUATION OF UNBOUND ROAD BASE AND SUB-BASE AGGREGATES

Impact Fatigue on Suction Valve Reed: New Experimental Approach

g L Agenda Chapter 13 Problem 28 Equations of Motion for SHM: What if we have friction or drag? Driven Oscillations; Resonance 4/30/14 k m f = 1 2π

3 1 PRESSURE. This is illustrated in Fig. 3 3.

PHYS 101 Previous Exam Problems

Offshore platforms survivability to underwater explosions: part I

JSEE. Slope Stability and Bearing Capacity of Footings on Top of Slopes Under Repeated Dynamic Loads. 1. Introduction

STRIDE PROJECT Steel Risers in Deepwater Environments Achievements

Pushover Analysis of Water Tank Staging

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

Special edition paper

Waves. harmonic wave wave equation one dimensional wave equation principle of wave fronts plane waves law of reflection

ISOLATION OF NON-HYDROSTATIC REGIONS WITHIN A BASIN

A New Generator for Tsunami Wave Generation

Pushover analysis with ZSOIL taking soil into account. Stéphane Commend GeoMod Ing. SA, Lausanne

The Adequacy of Pushover Analysis to Evaluate Vulnerability of Masonry Infilled Steel Frames Subjected to Bi-Directional Earthquake Loading

ITTC Recommended Procedures and Guidelines

Elastic-Plastic Finite Element Analysis for Zhongwei--guiyang Natural Gas Pipeline Endangered by Collapse

Study to Establish Relations for the Relative Strength of API 650 Cone Roof Roof-to-Shell and Shell-to- Bottom Joints

Numerical Simulations of a Train of Air Bubbles Rising Through Stagnant Water

The behaviour of tsunamis

Wave. 1. Transverse 2. Longitudinal 3. Standing

Adaptive Pushover Analysis of Irregular RC Moment Resisting Frames

RELIABILITY ASSESSMENT, STATIC AND DYNAMIC RESPONSE OF TRANSMISSION LINE TOWER: A COMPARATIVE STUDY

Catenary Mooring Chain Eigen Modes and the Effects on Fatigue Life

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad CIVIL ENGINEERING TUTORIAL QUESTION BANK

7 JAXA Special Publication JAXA-SP--8E the internal wall surface of the tower at the three different levels shown in Figure. Strain (in the vertical d

Displacement-based calculation method on soil-pile interaction of PHC pipe-piles

An experimental study of internal wave generation through evanescent regions

Pore-Air Entrapment during Infiltration

STUDY ON TSUNAMI PROPAGATION INTO RIVERS

Soil-Structure Interaction Analysis for Bridge Caisson Foundation

Deformation parameters of soils determined by the cone penetration test

Clarification of Behavior of Huge Tsunami Action on Bridges - Hydraulic Model Experiment and Simulation Technology -

Student name: + is valid for C =. The vorticity

CFD Simulation and Experimental Validation of a Diaphragm Pressure Wave Generator

LABORATORY EXPERIMENTS ON WAVE OVERTOPPING OVER SMOOTH AND STEPPED GENTLE SLOPE SEAWALLS

A NEW GOLF-SWING ROBOT MODEL UTILIZING SHAFT ELASTICITY

An Innovative Solution for Water Bottling Using PET

Friction properties of the face of a hand-held tennis racket

CH 17 - MECHANICAL WAVES & SOUND. Sec Mechanical Waves

EMPIRICAL FORMULA OF DISPERSION RELATION OF WAVES IN SEA ICE

Investigation of Stresses in Ring Stiffened Circular Cylinder

Seismic waves. Seismic waves, like all waves, transfer energy from one place to another without moving material. Seismic Waves 1 Author Paul Denton

LOCALLY CONCENTRATED SEVERE BEACH EROSION ON SEISHO COAST CAUSED BY TYPHOON T0709

[Barve, 4(7): July, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

Learn more at

Available online at Procedia Engineering 00 2 (2010) (2009)

Waves Part II. non-dispersive (C g =C)

THE EFFECT OF EMBEDMENT DEPTH ON BEARING CAPACITY OF STRIP FOOTING IN COHESIVE FRICTIONAL MEDIUM

Behavior of Square Footing Resting on Reinforced Sand Subjected to Static Load

CFD AND EXPERIMENTAL STUDY OF AERODYNAMIC DEGRADATION OF ICED AIRFOILS

Transcription:

SHAKING TABLE TESTS AND EFFECTIVE STRESS ANALYSES ON THE DYNAMIC BEHAVIOR OF WEDGED CAISSONS Takahiro SUGANO 1, Katsumi KISHITANI 2, Masaaki MITO 3, Kou NISHINAKAGAWA 4, Shin'ichi IDO 5, Masanori SHIMA 6 And Koji SEKIGUCHI 7 SUMMARY We have been developing " wedged caisson" as quay wall structures with a high earthquake resistant capacity without an enormous increase in construction cost. The wedged caisson has a bottom that declines towards the ground. Since safety against sliding failure of the caisson increases (to a limit) with the declination angle of the bottom, the width of the caisson can be reduced from that of the traditional caisson. To find the suitable range of the bottom declination angle, a series of shaking table tests using 1/22 scale model caissons with bottom declinations of, 5, 1 degrees were carried out. The tests were also simulated numerically using an effectivestress-based fully coupled analysis method, LIQCA, where a cyclic elasto-plastic constitutive model was implemented. From the results of the shaking table tests and the effective-stress-based analysis method, it was found that the seismic capacity of the slender wedged caisson with a bottom declination of 5 degree is comparable to that of the traditional caisson without any bottom declination. INTRODUCTION During the 1995 Hyogoken-Nambu Earthquake, most gravity type quay walls suffered tremendous damage due to intense seismic shocks, liquefaction of the replaced soil under the rubble mound of the caisson foundation and liquefaction of the reclaimed land. However, a quay wall designed with a seismic coefficient of.25 using the Technical Standard for Port and Harbour Facilities in Japan [Japan Port and Harbour Bureau, 1989] survived the seismic shocks and served as a useful facility for emergency transport. From this experience, the significance of a seismically strong quay wall was widely recognized. According to the technical standard, the following stability conditions under the seismic shocks have to be evaluated for the design of gravity type quay walls: 1) sliding failure of the quay wall; 2) bearing capacity of the foundation; and 3) overturning of quay wall. Among these conditions, the sliding failure becomes the critical condition for quay walls designed with high seismic coefficient of.2 -.25. Through trial design of seismically strong quay walls, it was experienced that the width of the caisson becomes large, and ground improvement to support them also becomes costly. 1 2 3 4 5 6 7 Port & Harbour Research Institute, Ministry of Transport, Yokosuka, Japan Kobe Investugation and Design Office, The Third District Port Construction Bureau, Ministry of Transport, Kobe, Japan Institute of Technology, Penta-Ocean Construction Co., Ltd., Tochigi, Japan Office of New Frontier Engineering, Takenaka Corporation, Tokyo, Japan Civil Engineering Div., Toyo Construction Co., Ltd., Tokyo, Japan Engineeing & Development Department, Toa Corporation, Tokyo, Japan Applied Technology Research Center, NKK Corporation, Kawasaki, Japan; E-mail:ksekigut@lab.keihin.nkk.co.jp

In late 1995, a simple method to increase safety factor against sliding failure was proposed by the authors, and a joint project was initiated to develop the "wedged caisson" as quay wall structures with high earthquake resistant capacity at low cost. The wedged caisson has a bottom that declines towards the ground. Since safety against sliding failure of the caisson increases (to a limit) with the declination angle of the bottom, the width of the caisson can be reduced from that of the traditional caisson. The purposes of the present study are : 1) to compare the seismic capacity of the wedged caisson with the traditional caisson without bottom declination, and specifically 2) to find the suitable range of the bottom declination angle. Method and Test Conditions UNDERWATER SHAKING TABLE TEST To simulate the behavior of the wedged caisson constructed in sea water, underwater shaking table with a diameter of 5.5 m was used. A table used was implemented at the bottom of a water pool with a 15x15m plane size and a 2 m depth [Sugano et al., 1996]. Three full size quay walls with a design water depth of 12.7 m and bottom declinations of, 5 and 1 degrees were designed under the same seismic coefficient of.25 following the technical standard [Japan Port and Harbour Bureau, 1989]. As shown in Fig. 1, the resultant caisson widths are decreased with an increase in the bottom declination angles. A similitude for a shaking table test on soil-structurefluid model in 1G gravitational field [Iai, 1988] was adopted, and a scale factor of 22 (prototype/model) was employed resulting in the similitude summarized in Table 1. Case A2 Case A3 5 degrees 18 m 15 m Wedged Caisson Compacted Sand Stone M ound Fig. 2 shows a side view of the test model for Case A3 together with the measurement instrumentation. In each test, three units of model caisson with a 525 mm width in the shore line direction were set together, and the displacement measurement was taken for the central unit, to reduce the effect of the side friction between the back fill and the test container. The model caissons were made of thick aluminum plates and filled with dry sand such that the unit weight of the model caisson becomes 21 kn/m 3. At the bottom of the model caisson, rubber sponge mat was glued to satisfy the frictional factor of.7 as assumed in the design of the prototype. The foundation ground, which is assumed to be a firm ground in the prototype, was made from Grade 5 Soma sand mixed with 3% weight jet cement. The rubble mound beneath the caisson was modeled using Grade 4 crushed stones with a range of particle size of 2-3 mm. After placing 3 model caissons on the crushed stone mound, Case A4 1 degrees Firm Ground 13 m Fig.1: Cross sections of test models. Table 1: Similitude for shaking table test. Parameter Prototype/ Scale Model Length λ 22. Density 1 1. Time λ.75 1.2 Stress λ 22. Displacement 2 λ 1.5 13 Velocity λ.75 1.2 Acceleration 1 1.

accelerometers and porewater pressure meters were installed using thin strings, and subsequently the back was filled and compacted manually with air-dried Grade 5 Soma sand. Then the water level was elevated slowly to a specified water level to saturate the model ground. Line A Line B Line C Fig.2: Side view and measurement instrumentation in Case A3 Exp. LIQCA (a) Line A (b) Line B (c) Line C Fig.3: Measured and calculated maximum acceleration (Case A3: Gal) Exp. LIQCA 5 15 (a) Line A 5 15 3 (b) Line B 5 15 (c) Line C Fig.4: Measured and calculated maximum acceleration (Case A3: Gal)

To compare the seismic capacity of the model caissons, a staged shaking method was adopted where constant amplitude sinusoidal acceleration with a 1 Hz frequency and a 2 s duration (.98 Hz frequency and 2.32 s duration in prototype) were applied in the direction perpendicular to the shore line. The amplitudes of the acceleration in the first stage was 1 Gal, and then amplitude of and Gal followed. After each excitation, displacement measurements of the model caisson and the ground surface were taken. Results of Test Figures 3 and 4 show measured maximum acceleration in Case A3 (bottom declination of 5 degrees) with input accelerations of and Gal, respectively. From the comparison between Fig.3(a) and Fig,4(a), it is observed that maximum acceleration ratio between the top and bottom of the caisson (AH6/AH5) is affected by the input acceleration level, suggesting the seismic isolation effect of the gravity type quay wall under strong excitations. Figure 5 shows time histories of lateral displacement of caisson from Cases A2, A3 and A4 with input acceleration of Gal. From the figure, it is observed that 1) the caisson is moving gradually towards the sea during the excitation, and that 2) in Case A4, lateral displacement at D-2 (top of the caisson) is developing linearly with time. From the measured displacements such as that shown in Fig.5, residual displacements at the bottom of the caisson and residual rotations of the caissons were calculated and plotted in Figures 7(a) and (b). From these figures, it may be observed that 1) the residual displacements at the bottom of the caisson is not much affected by the bottom declination angle; 2) the residual rotations of the caisson in Case A4 (bottom declination of 1 degrees ) is greater than those of Cases A2 and A3; and that 3) there is little difference between the results in Case A2 ( degrees) and A3 (5 degrees). Disp. (cm) Disp. (cm) Disp. (cm).2 D.1. D.2 -.2 -.4 -.6 -.8 (a) Case A2 ( degree) -1. 1 2 3 Time (s) 4.2. -.2 -.4 -.6 -.8.2. -.2 -.4 -.6 -.8-1. (b) Case A3 (5 degree) -1. 2 3 4 5 Time (s) (c) Case A4 (1 degree) 4 5 6 time (s) Fig.5: Lateral displacements of caisson from tests (Input = Gal: - sign indicates disp. towards sea) Method and Conditions of Analysis EFFECTIVE STRESS ANALYSIS Nine cases of shaking table tests (3 models x 3 input motions) as described in Section 2 were simulated numerically using an effective-stress-based fully coupled analysis method, LIQCA, where a cyclic elasto-plastic constitutive model was implemented [Oka et al., 1992; 1994]. Prior to the effective stress analyses, three cases (3 models) of static elasto-plastic analyses considering gravity force were conducted to estimate the initial stresses of the caisson-ground systems. Table 2 summarizes the material parameters used in the analysis. Among these parameters, are measured parameters unit weights, void ratios, and shear wave velocities. It was found that the plastic modulus parameters of the stone mound greatly affect the calculated residual displacement of the model caisson, from trial calculations on Case A3 with Gal acceleration. Thus these parameters were determined by fitting to the measured residual displacements. The other parameters were estimated based on past experience. It is noted that the overconsolidated ratio, OCR, used in the model is a parameter to control the dilatancy of soil, and does not necessarily correspond to the conventional definition of OCR [Sekiguchi et al., 1999]. In the analyses, the Rayleigh damping of.2% for the stiffness matrix varying with time was assumed. A time step of.25 s ( step/cycle) was used based on the trial calculations. 4

Table 2: Material parameters used in the effective stress analysis γ(kn/m 3 ) k (m/s) e λ κ Vs (m/s) M f M m B B 1 C f OCR Stiff Ground 1) 2.4..55 Stone Mound 19.4.1.74.3.1 1.34 1.16 1.2 Stone Moud/ 19.4.1.74.3.1 1.16 1. 1.2 Caisson 3) Caisson in Water 2) 21... Caisson in Air 2) 21... Compacted Ssand in 19.8 1-5.65.3.1 115 1.51 1.31 25 25 3. Water Compacted Sand in 15.8 1-5.65.3.1 115 1.51 1.31 25 25 3. Air Compacted Sand in 19.8 1-5.65.3.1 115.98.84 25 25 3. Water/Caisson 3) Compacted Sand in Air/Caisson 3) 15.8 1-5.65.3.1 115.98.84 25 25 3. Notations: γ= Unit weght; k = Coefficient of permeability; λ = Compression index; κ = Swelling index; Vs = Shear wave velocity; M f = Stress ratio parameter corresponds to failure angle; M m = Stress ratio parameter corresponds to phase transformation angle; B, B 1, C f = Plastic modulus parameters; OCR = Overconsolidatio ratio 1) Elastic material was assumed (Young's modulus = 5 MPa; Poisson's ratio =.45) 2) Elastic material was assumed (Young's modulus = 7 MPa; Poisson's ratio =.34) 3) Thin one layer elements were used as interface between the model caisson and the ground materials Results of Analysis Figures 3 and 4 compare the measured and calculated maximum accelerations in Case A3 where the bottom declination angle is 5 degrees. It is observed that the agreement is good at the measurement line B in Fig. 3 ( Gal); and at all the measurement lines in Fig.4 ( Gal). In Cases A2 and A4, the same tendency was recognized. Figure 6 shows calculated residual displacement in three cases after the excitation of Gal. From these figures, it is observed that the caisson is moving transiently towards the sea with an anti-clockwise rotation as was observed in the shaking table tests. The relationships between shear stress and strain in the stone mound shown in Fig.6(b) clearly indicate that the movement of the caisson is induced by the accumulated residual shear strain in the stone mound. It is noted that the deformation of the upper portion of the fill (two FE layers above the water table) is overestimated, because the portion is modeled as a completely dry non-linear material. Figures 7(a) and (b) compare the calculated and measured residual displacements at the bottom of the caisson and residual rotations of the caissons. From these figures, it may be observed that 1) the calculated results are consistent with those measured in the shaking table test; 2) the seismic resistant capacity of the slender wedged caisson with bottom declination angle of 5 degrees is practically identical to that of the traditional caisson with a flat bottom. CONCLUSIONS We have been developing " wedged caisson" as economical quay wall structures with high earthquake resistant capacity. To study the suitable range of the bottom declination angle, a series of underwater shaking table test using 1/22 scale model caisson with bottom declinations of, 5 and 1 degrees were carried out. From the shaking table tests, it was found that: 1) the residual displacements of the model caisson with a 5 degree bottom declination were comparable to those without bottom declination; and that 2) the displacements of the model caisson with a 1 degree bottom declination were greater than those of the other two models. 5

(a) Case A2 (bottom declination angle is degrees) (b) Case A3 (bottom declination angle is 5 degrees) (c) Case A4 (bottom declination angle is 1 degrees) Fig.6: Calculated residual deformations of caisson-ground systems. ( Gal; Displacement scale is 5 times as much as geometric scale) 6

Residual displacement (cm).5.4.3.2.1. Case Inclination Exp. LIQCA (degree) A2 A3 5 A4 1 -.1 1 3 5 Input acceleration (Gal) (a) Residual displacement at the bottom of the caisson { Residual rotation (degree).7.6.5.4.3.2.1. Case Inclination Exp. LIQCA (degree) A2 A3 5 A4 1 { -.1 1 3 5 Input acceleration (Gal) (b) Residual rotation of the caisson Fig.7: Comparison of measured and calculated residual movements of model caissons. 7

The shaking table tests were simulated numerically using an effective-stress-based fully coupled analysis method, LIQCA, where a cyclic elasto-plastic constitutive model was implemented. From the results of the analyses it was found that: 1) the calculated acceleration and residual displacements agreed well with those observed with the suitable choice of soil parameters; and that 2) the seismic capacity of a caisson with a 5 degree bottom declination was comparable to those without any declination, as was suggested from the results of shaking table tests. ACKNOWLEDGEMENTS The research work presented in this paper was conducted as a part of "Joint Research Project on the Development of Wedged Caisson", in which seven organizations participated: Port and Harbour Research Institute, Ministry of Transport; The Third District Port Construction Bureau, Ministry of Transport; Penta- Ocean Construction Co., Ltd.; Takenaka Civil Engineering & Construction Co., Ltd.; Toyo Construction Co., Ltd.; Toa Corporation; and NKK Corporation. The authors are grateful to Professor Fusao Oka of Kyoto University and Professor Atsushi Yashima of Gifu University for their advice on the analysis using LIQCA. The authors extend special thanks to the late Dr. Masataka Inatomi (formerly Director of Structures Division, Port and Harbour Research Institute) for his leadership in this research project. REFERENCES Iai, S.(1988), "Similitude for shaking table tests on soil-structure-fluid model in 1G gravitational field", Report of the Port and Harbour Research Institute, Vol.27, No.3, pp.3-24. Japan Port and Harvour Bureau(1989), Technical Standard for Port and Harbour Facilities. Oka, F., Yashima, A., Kato, M. and Sekiguchi, K.(1992), "A constitutive model for sand based on the non-linear kinematic hardening rule and its application", 1th World Conference on Earthquake Engineering, Madrid, Spain, pp.2529-2534. Oka, F., Yashima, A., Shibata, T., Kato, M. and Uzuoka, R.(1994), "FED-FDM coupled liquefaction analysis of a porous soil using an elasto-plastic model", Applied Scientific Research, Vol.52, pp.29-245. Sekiguchi, K., Onda, K., Nagayama, H., Tanabe, T., Hasegawa, Y. and Nakagawa, S. (1999), "Application of an effective-stress-based liquefaction analysis method to engineering problems", NKK Technical Review, No.81, December (to be published). Sugano, T., Morita, T., Mito, M., Sasaki, T. and Inagaki, H.(1996), "Case studies of caisson type quay wall damage by Hyogoken-Nanbu Earthquake", Eleventh World Conference on Earthquake Engineering, CD-ROM paper, Acapulco, Mexico, 8pp. 8