Oxygen Saturation Monitors & Pulse Oximetry

Similar documents
Rad-57 Pulse CO-Oximeter

KNOW YOUR EQUIPMENT: Pulse oximeter Verghese Cherian Associate Professor of Anesthesiology Hershey Medical Center

RESPIRATORY MONITORING AND OXIMETRY

RESPIRATORY PHYSIOLOGY, PHYSICS AND

TABLE OF CONTENTS 1 Overview Appearance Name and Model Intended Use Feature List Important Acroynms...

Instructions to User

Using the Lifebox oximeter in the neonatal unit. Tutorial 1 the basics

The Physiologic Basis of DLCO testing. Brian Graham Division of Respirology, Critical Care and Sleep Medicine University of Saskatchewan

Biomedical Sensor Systems. Laboratory

Oxygen and Carbon dioxide Transport. Dr. Laila Al-Dokhi

Capnography in the Veterinary Technician Toolbox. Katie Pinner BS, LVT Bush Advanced Veterinary Imaging Richmond, VA

Sensor. Directions For Use

Instructions to User

CHAPTER 6. Oxygen Transport. Copyright 2008 Thomson Delmar Learning

.$2;,)*3/6$ USER MANUAL

HCO - 3 H 2 CO 3 CO 2 + H H H + Breathing rate is regulated by blood ph and C02. CO2 and Bicarbonate act as a ph Buffer in the blood

Section Three Gas transport

Finger Pulse Oximeter. User Manual. Innovo Medical Stafford Centre Drive Suite B Stafford, TX

New Generation System M, leading the World in the Non-Invasive Measurement of Critical Real-Time Parameters.

Gas exchange. Tissue cells CO2 CO 2 O 2. Pulmonary capillary. Tissue capillaries

respiratory cycle. point in the volumes: 500 milliliters. for men. expiration, up to 1200 milliliters extra makes breathing Respiratory

Instructions to User

International Journal of Scientific & Engineering Research Volume 9, Issue 4, April ISSN

Gases and Respiration. Respiration Overview I

Gebrauchsanweisung Mode d' emploi Instrucciones para el uso Istruzioni per l'uso Инструкции по зксплуатации. ri-fox N

660 mm Hg (normal, 100 mm Hg, room air) Paco, (arterial Pc02) 36 mm Hg (normal, 40 mm Hg) % saturation 50% (normal, 95%-100%)

Warning: Keep away from small children; -30 C +70 C User Guide GO2 % SpO2

PULSOX -2 INSTRUCTION MANUAL

Cardiac Output Simulation for Specific Makes of Monitor. Each injection yields in a time-temperature curve whose area represents the cardiac output:

Instruction for Use. Mobile Pulse Oximeter. (File No.: IFU-MPO) Version: 01. Zhejiang Medzone Medical Equipment Co.,Ltd

Section Two Diffusion of gases

Respiration. Figure 22: Schematic representation of the respiratory system

Physiology Unit 4 RESPIRATORY PHYSIOLOGY

Pco2 *20times = 0.6, 2.4, so the co2 carried in the arterial blood in dissolved form is more than the o2 because of its solubility.

P215 Respiratory System, Part 2

Oxygen Saturation Monitor PULSOX -2. Instruction Manual

Respiratory System Study Guide, Chapter 16

Fingertip Pulse Oximeter

Respiration (revised 2006) Pulmonary Mechanics

Unit II Problem 4 Physiology: Diffusion of Gases and Pulmonary Circulation

Respiratory physiology II.

Gas Exchange Respiratory Systems

I Physical Principles of Gas Exchange

WARNING: EXPLOSION HAZARD

MEASUREMENTS OF BLOOD SATURATION INSIDE A VENTRICULAR ASSIST DEVICE 2 1. INTRODUCTION

Respiratory Lecture Test Questions Set 3

Instruction Manual CMS-50DL

Monitoring. Suzie Ward March 2013

Chapter 23. Gas Exchange and Transportation

AP Biology. Gas Exchange Respiratory Systems. Gas exchange. Why do we need a respiratory system? Optimizing gas exchange. Gas exchange in many forms

Experiment B-3 Respiration

CARESCAPE V100. Vital signs monitor Connecting intelligence and care. Features

Then the partial pressure of oxygen is. b) Gases will diffuse down a pressure gradient across a respiratory surface if it is: i) permeable ii) moist

PROBLEM SET 9. SOLUTIONS April 23, 2004

IV. FROM AQUATIC TO ATMOSPHERIC BREATHING: THE TRACHEA & THE LUNG

Biology 212: Anatomy and Physiology II Lab #7: Exercise Physiology in Health and Disease

Product description concerning v-tac

Chapter 17 The Respiratory System: Gas Exchange and Regulation of Breathing

Instruction Manual CMS-50DL

Alveolus and Respiratory Membrane

Chapter 23. Gas Exchange and Transportation

RESPIRATORY REGULATION DURING EXERCISE

SenTec OxiVenT Illuminate Ventilation and Oxygenation PCO2 PO2. Digital Transcutaneous Blood Gas Monitoring

City, University of London Institutional Repository

S2c Oxygenation & Ventilation

Solutions for transcutaneous monitoring

CHAPTER 3: The respiratory system

Essential Skills Course Acute Care Module. Respiratory Day 2 (Arterial Blood Gases) Pre course Workbook

Instructions to User

AIIMS, New Delhi. Dr. K. K. Deepak, Prof. & HOD, Physiology AIIMS, New Delhi Dr. Geetanjali Bade, Asst. Professor AIIMS, New Delhi

A new method for noninvasive venous blood oxygen detection

Point-of-Care Testing: A Cardiovascular Perfusionist s Perspective

CHAPTER 3: The cardio-respiratory system

Respiratory System Physiology. Dr. Vedat Evren

Rodney Shandukani 14/03/2012

Capnography. The Other Vital Sign. 3 rd Edition J. D Urbano, RCP, CRT Capnography The Other Vital Sign 3 rd Edition

YOUR PERSONAL OXIMETER:

BREATHING AND EXCHANGE OF GASES

Office. Hypoxia. Or this. Or even this. Hypoxia E-1. COL Brian W. Smalley DO, MSPH, CPE

SCENARIO #2 CARBON MONOXIDE INCIDENT IN AN AUTO SHOP

A Dusky Hypoxic Woman. Craig Smollin MD Associate Medical Director California Poison Control Center - SF Div.

as provided by other available near infrared oximeters. Moreover, OxiplexTS complements the pulse oximeter in

Breathing: The normal rate is about 14 to 20 times a minute. Taking in of air is called Inspiration and the forcing out of air is called Expiration.

BIOPAC Blood Flow Monitor

OXYGEN SATURATION MONITOR PULSOX Instruction Manual. This instrument must be used according to the instructions of the doctor.

Fysiologie van de ademhaling - gasuitwisseling

SenTec Digital Monitoring System Illuminate Ventilation and Oxygenation in Neonatology PCO2 PO2

Oxicom 3000 INSTRUCTION MANUAL

Oxicom 2100 INSTRUCTION MANUAL

PICU Resident Self-Study Tutorial The Basic Physics of Oxygen Transport. I was told that there would be no math!

D-MAS HyperSat DanMedical hyperbaric remote patient monitoring system

RESPIRATORY GAS EXCHANGE

Respiration - Human 1

I. Gas Exchange Respiratory Surfaces Respiratory Surface:

OXYGEN PHYSIOLOGY AND PULSE OXIMETRY

Recitation question # 05

Then the partial pressure of oxygen is x 760 = 160 mm Hg

CDI Blood Parameter Monitoring System 500 A New Tool for the Clinical Perfusionist

RESPIRATION III SEMESTER BOTANY MODULE II

VENTILATION AND PERFUSION IN HEALTH AND DISEASE. Dr.HARIPRASAD VS

Transcription:

Oxygen Saturation Monitors & Pulse Oximetry Key Points Oxygen Saturation Monitors & Pulse Oximetry : Role of hemoglobin in respiration Basic principle of how SpO 2 is determined by absorption of red and infra-red Know the wavelengths of red and infra-red used in a SpO 2 sensor Oxygen saturation SpO 2 vs oxygen content in the blood i.e. the oxygen dissociation curve Tone modulation in pulse oximeters - why? Know the forms Hemoglobin can take What does Perfusion Index (PI) measure Sources of inaccuracy in SpO 2 measurement Detection of cerebral O 2 saturation Know the names Nellcor & Masimo www.youtube.com/watch?v=wxobjexxneo or http://safeyoutube.net/w/owkc D. J. McMahon 141105 rev cewood 2017-11-14 2 4 Ventilation refers to the physics of gas movement into the lungs. (mechanical) Respiration refers to the exchange of oxygen and carbon dioxide in cells by means of hemoglobin in the blood. (chemical) Hemoglobin - Each hemoglobin unit has 4 heme groups, each of which can carry one oxygen molecule. 5 6

Heme - Oxygen transport in the blood - 7 8 Saturation defined: Assume 100 hemoglobin molecules together carry a maximum of 400 (100 x 4) oxygen molecules. If these 100 hemoglobin molecules were carrying 380 oxygen molecules they would be carrying (380 / 400) x 100 = 95% of the maximum number of oxygen molecules that could carry. They would be 95% saturated. Oxygen saturation is referred to as SpO 2. (Peripheral capillary Oxygen Saturation) 9 PaO 2 and PvO 2 are the partial pressures of O 2 in the arterial or venous blood. Same applies to CO 2 SaO 2 and SpO 2 (saturation) both describe the percentage of hemoglobin that is carrying oxygen, but: SaO 2 is determined by laboratory analysis (a co-oximeter). SpO 2 is determined by a pulse-oximeter. Pulse oximeters are widely used, but SaO 2 is still considered the gold standard for assessing oxygenation. 10

The Oxygen Dissociation Curve: Effects of blood CO 2, temperature, or ph on the curve: 11 12 Basis for SpO 2 monitoring: De-oxygenated hemoglobin (Hb) partially absorbs light at 660nm. Oxygenated hemoglobin partially absorbs light at 940nm. (visible light is 400-720 nm) higher absorption; low signal level If we measure the absorption of both wavelengths at any given instant and determine their ratio, we have the percentage of total hemoglobin that is carrying oxygen. i.e. the Oxygen saturation. In practice, two LED s each send a 660nm or 940nm signal through any perfused tissue to a sensor, which receives the partially absorbed signals. OxyHemoglobin de-oxygenated Hemoglobin Those signals are sent to the monitor where they are processed and display the % saturation, pulse rate, and (optionally) a plethysmographic (volume) waveform. 13 lower absorption; high signal level (absorption) 14

a way to remember this... 660 nm 940 nm UV IR 15 16 What the monitor sees: 660 nm red 940 nm IR 17 18

R-curve for an SpO 2 monitor: Each manufacturer has a specific R-curve for their monitors, determined by the components and algorithm they use. (When testing monitors, we must know the manufacturer s R-curve.) (note the non-linear line) 19 20 Tone Modulation in Pulse Oximeters: Almost all pulse oximeters emit a brief audio tone with each pulse, whose pitch is harmonized with the saturation value. The higher the saturation, the higher the pitch. Forms of Hemoglobin: Hemoglobin Hb: Hemoglobin without attached O 2 ) Oxyhemoglobin HbO 2 : Hemoglobin with attached O 2 ) Carboxyhemoglobin COHb: Hemoglobin with attached CO, Carbon Monoxide) gives inaccurate SpO 2 Methemoglobin MetHb: (pronounced MET-hemoglobin) cannot bind to O 2 and gives inaccurate SpO 2 Sources of Inaccuracy in Pulse Oximetry: Motion of the perfused tissue (Motion Artifact) Poor tissue perfusion due to cold temp or vascular disease Carboxyhemoglobin: typically high in smokers. (May be mis-read as HbO 2.) Methemoglobin: from toxins. (May be mis-read as either HbO 2 or Hb.) Diagnostic dyes in bloodstream: methylene blue, cardio green, & others Nail polish Skin pigmentation listen... http://www.hark.com/clips/wshsvssnrl-pulse-oximeter 22 Ambient light that is rich in infrared (e.g. surgical lights) 28

Inaccuracy due to Carboxy-Hb and Met-Hb: Perfusion Index (PI): A measurement of signal strength, which indicates the amount of pulsatile blood flow at the specific site on the patient s body where a sensor is placed. References the pulse signal to the offset. Especially useful in newborns. 660 nm (red) 940 nm (infrared) 29 30 Pleth Variability Index (PVI): Advanced hematological monitoring: Oxygen Saturation (SpO 2 ) Pulse Rate (PR) Perfusion Index (PI) Measures the changes in PI (Perfusion Index) during each respiratory cycle. Useful to check balance between the intrathoracic (chest) pressure and intravascular fluid volume. e.g. during asthma attack, or to adjust the patient s blood volume. 31 Hemoglobin (SpHb ) Oxygen Content (SpOC ) Carboxyhemoglobin (SpCO ) Methemoglobin (SpMet ) Pleth variability index (PVI ) note: all Masimo 32

Proprietary algorithm for Masimo s Signal Extraction Technology ( SET ) 33 34 SatSecond as an alarm parameter: The change in saturation and the time span factored together as a determinate for alarms. SatSecond as an alarm parameter: The change in saturation and the time span factored together as a determinate for alarms. Two examples where no alarm is activated: Two examples where an alarm is activated: 35 36

Earlier calibration of sensor (1980 s & 1990 s) Disposable sensors - Nellcor s OxiMax calibration 38 44 Nonin s Onyx miniature pulse oximetry monitor: Onyx knock-offs - First self-contained miniature SpO 2 monitor 48 49

Regional O 2 Saturation (rso 2 ): Detection of O 2 saturation in the brain Detects red and infrared signals by reflection in brain tissue 50 51 rso 2 : Bilateral cerebral oxygenation during surgery: Cerebral Oxygen Monitoring: Regional Oxygen saturation (rso 2 ) Somanetics InVos System 52 CASMed ForeSight system 53

Somanetics INVOS rso 2 monitor: Most major manufacturers include either Nellcor or Masimo SpO 2 technology in their monitors as OEM boards : http://www.somanetics.com/our-technology 54 55 Major Players in Pulse Oximetry: Manufacturers of stand-alone monitors: - Nellcor - Masimo - Nonin - Invivo Research Manufacturers of multi-parameter monitors who license SpO 2 subassemblies from Nellcor or Masimo: - Philips - Spacelabs - Datex-Ohmeda - G.E. Medical 56 Pulse Ox testers for biomed shops - There is no such thing as an SpO 2 simulator! A simulator mimics a parameter with a directly equivalent voltage, impedance, pressure, etc. There are no true SpO 2 simulators because O 2 saturation cannot be directly duplicated in a test device. SpO 2 test devices only mimic the SpO 2 by means of an optical or opto-mechanical component. ref: www.hospimedica.com/whitepapers/52c1c251319ad_sp02.pdf 57

Pulse Ox testers for biomed shops - Netech s FingerSim - Pulse Ox testers for biomed shops - Pronk s OxSim OX-1 - Fluke Index 2 - Fluke Spot Light - 58 Fluke ProSim 8 with SpO2 tester Clinical Dynamics SmartSat 59 SpO 2 monitors should be tested at a variety of saturation values, normal and abnormal, including variations in the pulse rate, and pulse volume (or amplitude), if possible. Example of tester options: 60