HC912B32 Cu Wire Conversion In FSL-KLM-FM (PCN 16642)

Similar documents
FINAL PRODUCT/PROCESS CHANGE NOTIFICATION #16819

Change Notification Cisco R2

FINAL PRODUCT/PROCESS CHANGE NOTIFICATION #16741

Product / Process Change Notification

Product Characterization Report. for the. SPX2815 Family of Products

INFORMATION NOTE N 046/13. Close Dambar and Test Pad Change of TLE7368x-Family. Subject of Change:

Bill Williams FMTC Probe Technology Development Group

WOMEN S BASKETBALL SECSPORTS.COM

Titanium Etch. TAIWAX MAXWAVE Co., Ltd, No. 999, Bayiu 1 st Rd., Guanyin Township, Taoyuan County Taiwan. Evan Chen

ELECTROSTATIC DISCHARGE (ESD) TESTING REPORT

LATCH UP TEST REPORT

THE 27TH BIENNIAL INTERVARSITY GAMES 2018

Total Ionization Dose (TID) Test Results of the RH117H Positive Adjustable Low Dose Rate (LDR) LDR = 10 mrads(si)/s

Implementing High Temperature Coplanarity Requirements for Components and PWBs. Proposed 1

JABATAN KEJURUTERAAN ELEKTRIK PUSAT PENGAJIAN DIPLOMA (PPD), SPACE UNIVERSITI TEKNOLOGI MALAYSIA KUALA LUMPUR

June NMFS Address 11, 2014 (NOAA): Council Address. Dover, DE 19901

Change Notification Cisco R2

Total Ionization Dose (TID) Test Results of the RH1021BMH-10 Precision 10V Low Dose Rate (LDR) LDR = 10 mrads(si)/s

TRAFFIC SIGNAL WARRANT SUMMARY

2007 ASME/IEEE Joint Rail Conference & Internal Combustion March Engine 13-16, 2007, Spring Pueblo, Technical Colorado, Conference USA

MPC5674F PMC Trimming of Internal Regulators and Low Voltage Detection

TR Page 1 of 21 QD30revD

LM LUMEN MAINTENANCE TEST REPORT

Amateur Radio Club QSO Party Rules

MODEL UM UNIVERSAL MANIFOLD ASSEMBLY (With or Without Control Valve) 1¼", 1½", 2", 2½", 76.1mm, 3", 4", 6",165.1mm, 8"

Freescale Semiconductor MMA6222AEG ±20/20g Dual-Axis Medium-g Micromachined HARMEMS Accelerometer

Product / Process Change Notification

Qualification of Fastrak & First Gen Product to Railway applications Shock and Vibration Standard EN 61373

Specification for Approval

Specification for Approval

Proto-qual Vibration Test Procedure 2.5 and 6 Vacuum Valves (3179 and 3223) Retest of Flight Spare Valves. GP-B P0735 Rev.-

Sports Information Guide

NZQA registered unit standard 1269 version 7 Page 1 of 5. Plan, prepare for, and carry out line shifts in a cable harvesting operation

installation instructions

GENERAL INFORMATION SHEET

GENERAL INFORMATION SHEET

KUALA LUMPUR CUP MALAYSIA S PREMIER INTERNATIONAL YOUTH FOOTBALL TOURNAMENT 2 & 3 MARCH 2019

Layout Design II. Lecture Fall 2003

Side-of-Pole Mount for 1 Module (SPM1) For Module Type C

IEP SENSOR BRACKET CHECKOUT AND VERIFICATION. This is a non-hazardous test.

Status update of Beam pipe. S. Tanaka KEK

Procurement Plan-Goods. Draft Bid Documents, including specs and quantities, draft SPN. Notice Advert. Noobjection. Prep & Submis sion by Ex Agency

Atqasuk Wind Resource Report

Calibration Procedure

A28 Series Two-Stage Temperature Controls with NEMA 1 Enclosure

Shakopee Lacrosse Board Meeting Minutes

GLAST Large Area Telescope:

Job Description and Person Specification

AFT OVERBOARD HANDLING SYSTEM: STORAGE WINCHES R/V SIKULIAQ Maximum Capability Document

Side-of-Pole Mount for 1 Module (SPM1) For Module Types A & B

_ pressure transducers. User Manual

Side-of-Pole Mount for 1 Modules (SPM1) For Module Types E, F, G, & H ASSEMBLY INSTRUCTIONS. step-by-step assembly and installation

By Dr Ahmad Fauzi Bin Puasa (AMN) Deputy Director of MIER

30 x 173mm TPDS-T Development

IAOS Young Statistician Prize (YSP) - Update Prepared by Gemma Van Halderen with input from 2018 YSP chair and 2019 incoming YSP chair

KC Scout Kansas City s Bi-State Transportation Management Center

Falling Supervisor Certification Assessment

Product / Process Change Notification

UNIVERSITY OF OKLAHOMA HEALTH SCIENCES CENTER. Automated External Defibrillator Policy

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES. For. EiKO Global, LLC W 84th Street, Shawnee, KS 66227

PolarPAK Solder Joint Reliability Based on Thermal Fatigue IPC-9701

DEVELOPMENT OF A PAVEMENT REHABILITATION STRATEGY FOR NATIONAL ROADS IN QUEENSLAND

World Rowing Strategic Planning Meeting

WĒKIU BUG BASELINE MONITORING

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

Aluminum Mechanical Lugs Dual Rated - One Conductor

DESIGN CRITERIA DIVISION 4900 TRAFFIC SIGNALS

IMPROVED SAFETY SURFACE ACCESS AT LOW COST AIRPORTS: KUALA LUMPUR INTERNATIONAL AIRPORT, MALAYSIA CASE STUDY

FEI Sports Forum, 8-9 April 2013, IMD Lausanne. Driving Round Table 2013

Adaptive test on wafer level

Certificate of Compliance

Air-Oil Systems, Inc. Ultra Air Products 2007 Price List UA Series, UA201 Series, UDR Series, UA301 Series, LFT Series, LFE Series, LFA

NDIA 51 st Annual Fuze Conference Low Cost p-sdf for ICM Rounds. L-3 BT Fuze 51st ANNUAL FUZE CONFERENCE

World Para Powerlifting. Qualification Pathway Appendix 1 January 2018

Report on OSU Opto-Pack Prototypes

DOCUMENTATION OF IRB DISCUSSIONS AND DECISIONS ( IRB MINUTES)

Emerging Crash Trend Analysis. Mark Logan Department of Main Roads, Queensland. Patrick McShane Queensland Transport

REPLACEMENT PARTS LIST FOR MODELS: Consult factory for all other models

Declaration of Conformity In Accordance with ANSI/ISEA

Draft Kivalina Wind Resource Report

The 2016 Turkish Airlines World Golf Cup. Competitor Information and Tournament Rules. Kuala Lumpur Qualifying Event, Wednesday 25 th May, 2016

Change to Chloramines. Teresa Rogers Texas Commission on Environmental Quality Water Supply Division - Utilities & Districts Section

Total Ionization Dose (TID) Test Results of the RH1028MW Ultralow Noise Precision High Speed Operational Low Dose Rate (LDR)

PORT ST. LUCIE UTILITY SYSTEMS DEPARTMENT FLUSHING REPORT

Citizen Advisory Group Meeting #8 May 5, Welcome. Today s meeting will focus on: Land Use & Transportation CHARLOTTEPLANNING.

Integrated Space Systems

NON-CATALOG. Features excellent image rejection, 27 db typ. low conversion loss, 7.0 db typ. aqueous washable J-leads for strain relief

Marathon walk's Complete Performance Training Plan

Shifting Lever. RAPIDFIRE Plus 11-speed

HOT SPOT MONITOR (HSM)

Declaration of Conformity In Accordance with ANSI/ISEA

Visual Inspection of Medicinal Products for Parenteral Use

ITU Plenipotentiary Conference October 16 November, Dubai, UAE Update on the preparatory process

Dental Complete Classic 2ZGF Rates

FINAL PRODUCT/PROCESS CHANGE NOTIFICATION #20342 Generic Copy

Answer: Team Name: Time Completed: 1 st min. 2 nd min. 3 rd min. 4 th min. 5 th min.

DOT-SP 8391 (FIFTHTEENTH REVISION) EXPIRATION DATE: (FOR RENEWAL, SEE 49 CFR )

ADVANCED TRANSIT OPERATIONS AND MODELING

Traffic Impact Analysis (TIA) Process and Procedures Manual. September 2017

TABLE OF CONTENT

Transcription:

HC912B32 Cu Wire Conversion In FSL-KLM-FM (PCN 16642) 1. Objective This report describes the 25um PdCu wire for HC912B32 on the 80QFP UDR technology device electrical distribution data versus baseline 25um Au wire. Current Wire: 25um Au wire Proposed New Wire: 25um PdCu wire 2. General Information Product Family: HC912B32 Fab site: FSL-CHD-FAB Mask set: 4J54E Package(s): 80QFP Assembly Site: Freescale Kuala Lumpur, Malaysia 3. Method Two data sets taken from selected key product, 30 units in each set at T0 analysis: 1. 30 units from 25um diameter PdCu wire qual lot 2. 30 units from 25um diameter Au wire control lot Page 1 of 5

Both qualification and control lots are tested to standard production final test flow. Electrical distribution data generated from the selected key parametric tests with Freescale standard criteria CPK > 1.67 and shift 15%. 4. Data and Summary: 4.1. Electrical Distribution Table: Selected Key Product: MC912D60A (112LQFP) M35Z The ED data from Selected Evaluation Vehicle will be representing the parts stated in section 2 General Information Temp 125 C Temp 125 C 6010:RIDDS_12MHZ Vdd 0.0 ma NA 60.0 39.920 0.310 21.607 40.032 0.259 25.674 NA PASS 6020:WIDDS_12MHZ Vdd 0.0 ma NA 10.0 6.863 0.072 14.612 6.853 0.067 15.546 NA PASS 6050:SIDDS_12MHZ Vdd 0.0 ua NA 50.0 7.448 2.147 6.607 5.625 1.462 10.116 NA PASS 1420:RIDDE_8MHZ Vdd 0.0 ma NA 85.0 53.825 1.947 5.337 54.460 1.429 7.123 NA PASS 1430:RIDDS_8MHZ Vdd 0.0 ma NA 50.0 27.697 0.210 35.320 27.750 0.176 42.160 NA PASS 1440:WIDDE_8MHZ Vdd 0.0 ma NA 12.0 9.998 0.395 1.688 10.071 0.314 2.046 NA PASS 1450:WIDDS_8MHZ Vdd 0.0 ma NA 8.0 4.859 0.060 17.379 4.853 0.060 17.451 NA PASS 1480:SIDDE_8MHZ Vdd 0.0 ua NA 50.0 4.636 1.283 11.790 3.752 0.868 17.769 NA PASS 2702:ATD0_Ramp_HI_8M TUE LSB -2.5 2.5-1.243 0.127 3.310-1.288 0.139 2.904 PASS PASS 2752:ATD0_Ramp40K_HI_8M TUE LSB -20.0 20.0 14.181 0.412 4.704 14.332 0.719 2.628 PASS PASS 2801:VRH0_Iref vrh0 ua NA 250.0 72.256 3.433 17.256 69.379 2.348 25.642 NA PASS 2821:VRL0_Iref vrl0 ua NA 250.0-71.187 2.113 50.671-70.305 2.275 46.939 NA PASS 2902:ATD1_Ramp_HI_8M TUE LSB -2.5 2.5-1.424 0.131 2.735-1.451 0.113 3.087 PASS PASS 2952:ATD1_Ramp40K_HI_8M TUE LSB -20.0 20.0-13.758 0.829 2.509-12.958 0.348 6.746 PASS PASS 3001:VRH1_Iref vrh1 ua NA 250.0 72.511 2.474 23.918 70.557 2.775 21.551 NA PASS 3021:VRL1_Iref vrl1 ua NA 250.0-71.016 2.618 40.867-70.412 2.188 48.809 NA PASS Page 2 of 5

Temp 25 C Temp 25 C 6010:RIDDS_12MHZ Vdd 0.0 ma NA 60.0 40.235 0.301 21.865 40.255 0.276 23.881 NA PASS 6020:WIDDS_12MHZ Vdd 0.0 ma NA 10.0 6.886 0.075 13.781 6.859 0.071 14.645 NA PASS 6050:SIDDS_12MHZ Vdd 0.0 ua NA 10.0 0.786 0.255 12.026 0.647 0.258 12.068 NA PASS 1420:RIDDE_8MHZ Vdd 0.0 ma NA 85.0 54.157 2.036 5.050 55.020 1.473 6.785 NA PASS 1430:RIDDS_8MHZ Vdd 0.0 ma NA 50.0 27.939 0.191 38.467 27.992 0.200 36.609 NA PASS 1440:WIDDE_8MHZ Vdd 0.0 ma NA 12.0 10.843 0.230 1.676 10.968 0.159 2.156 NA PASS 1450:WIDDS_8MHZ Vdd 0.0 ma NA 8.0 4.891 0.068 15.182 4.872 0.062 16.762 NA PASS 1480:SIDDE_8MHZ Vdd 0.0 ua NA 10.0 0.749 0.283 10.902 0.059 0.245 13.544 NA PASS 2702:ATD0_Ramp_HI_8M TUE LSB -2.5 2.5-1.230 0.158 2.680-1.309 0.135 2.929 PASS PASS 2752:ATD0_Ramp40K_HI_8M TUE LSB -20.0 20.0 13.816 0.662 3.114 13.605 0.713 2.988 PASS PASS 2801:VRH0_Iref vrh0 ua NA 250.0 76.533 3.320 17.415 74.486 2.980 19.633 NA PASS 2821:VRL0_Iref vrl0 ua NA 250.0-76.318 2.273 47.851-75.070 1.915 56.571 NA PASS 2902:ATD1_Ramp_HI_8M TUE LSB -2.5 2.5-1.388 0.126 2.942-1.375 0.139 2.691 PASS PASS 2952:ATD1_Ramp40K_HI_8M TUE LSB -20.0 20.0 11.586 0.643 4.362 12.947 0.847 2.777 PASS JUSTIFY 3001:VRH1_Iref vrh1 ua NA 250.0 77.245 2.754 20.909 75.083 3.096 18.831 NA PASS 3021:VRL1_Iref vrl1 ua NA 250.0-75.941 2.506 43.360-75.078 2.450 44.224 NA PASS Cu avg improved as it moved toward center of limits Page 3 of 5

Temp -40 C Temp -40 C 6010:RIDDS_12MHZ Vdd 0.0 ma NA 60.0 37.789 0.263 28.100 37.671 0.275 27.030 NA PASS 6020:WIDDS_12MHZ Vdd 0.0 ma NA 10.0 0.006 0.00007 47475.711 6.358 0.076 16.015 NA JUSTIFY Cu avg improved as moving away from spec limit. 6050:SIDDS_12MHZ Vdd 0.0 ua NA 10.0 0.647 0.175 17.862 0.688 0.190 16.363 NA PASS 1420:RIDDE_8MHZ Vdd 0.0 ma NA 85.0 51.392 1.926 5.818 51.785 1.537 7.205 NA PASS 1430:RIDDS_8MHZ Vdd 0.0 ma NA 50.0 26.419 0.171 46.048 26.356 0.171 46.056 NA PASS 1440:WIDDE_8MHZ Vdd 0.0 ma NA 12.0 10.478 0.301 1.685 10.548 0.208 2.330 NA PASS 1450:WIDDS_8MHZ Vdd 0.0 ma NA 8.0 4.576 0.065 17.658 4.519 0.071 16.329 NA PASS 1480:SIDDE_8MHZ Vdd 0.0 ua NA 10.0 0.492 0.162 19.506 0.658 0.182 17.110 NA PASS 2702:ATD0_Ramp_HI_8M TUE LSB -2.5 2.5-1.342 0.147 2.621-1.363 0.138 2.746 PASS PASS 2752:ATD0_Ramp40K_HI_8M TUE LSB -20 20.0 12.322 0.615 4.162 12.406 0.515 4.917 PASS PASS 2801:VRH0_Iref vrh0 ua NA 250.0 74.700 2.918 20.022 74.856 2.799 20.857 NA PASS 2821:VRL0_Iref vrl0 ua NA 250.0-74.466 2.416 44.767-73.486 2.581 41.776 NA PASS 2902:ATD1_Ramp_HI_8M TUE LSB -2.5 2.5-1.316 0.139 2.849-1.319 0.139 2.842 PASS PASS 2952:ATD1_Ramp40K_HI_8M TUE LSB -20 20.0 12.125 0.692 3.793 12.000 0.615 4.336 PASS PASS 3001:VRH1_Iref vrh1 ua NA 250.0 76.359 2.849 20.314 73.943 2.395 24.504 NA PASS 3021:VRL1_Iref vrl1 ua NA 250.0-75.557 2.983 36.376-74.234 2.581 41.872 NA PASS Shift analysis refers to analysis of shift of the distribution mean towards the nearest specification limit: % Shift (USL) = {Mean(new)-Mean(old)} / {Upper Spec Limit-Mean(old)} % Shift (LSL) = {Mean(new)-Mean(old)} / {Mean(old)-Lower Spec Limit} Page 4 of 5

4.2. Summary: From the above data, it was verified that the requirements and acceptance criteria was achieved. 5. Document History: Rev Date Originator O 13 th Feb Shahrol Nurul Aida-B35678 2015 Page 5 of 5