Owners Manual Models 4430BF3, 4430BF2 & 4430BF1 Floor Mounted Tri-Level Bottle Filling Tubular Fountain

Similar documents
Owners Manual. Models 4420BF1U & 4420BF1L Floor Mounted Bi-Level Bottle Filler Tubular Fountain

Halsey Taylor Owners Manual

Halsey Taylor Owners Manual

Halsey Taylor Owners Manual

Installation/Care/Use Manual Soft Sides Fountains with FLEXI-GUARD

SWIRLFLO Refrigerated fountains with FLEXI-GUARD

Installation/Care/Use Manual

PAGE (Rev. A - 06/17)

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Halsey Taylor Owners Manual STOP!

INSTALLATION, CARE & USE MANUAL. EMASMB & LMASMB Surface Mount Bottle Filling Stations

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

Installation and Use Manual

LK4420BFFR - FTN, 4420BFFR - FTN. Owners Manual

INSTALLATION INSTRUCTIONS 1/2 THERMOSTATIC VALVE AND TRIM

Installation Instructions

V43 Pressure Actuated Water Regulating Valve

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA. Trimpac 244a. September 16, 2013

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS

Anti-flood device Model B-1

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Non-Refrigerated Universal Bi-Level AquaAccess Barrier Free, Wall Mounted Water Cooler

INSTALLATION INSTRUCTIONS

Pressure Dump Valve Service Kit for Series 2300 Units

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

HORNE T109A/306A/307A THERMOSTATIC SHOWER VALVE FOR SURFACE MOUNTING WITH TIMED FLOW CONTROL INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

GAS DISTRIBUTION PRODUCTS TRANSITION FITTINGS

How to Order RM0 0 Z. IN/OUT fitting type Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø

D05 Pressure Regulating Valves

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

TECHNICAL DATA. Page 1 of 12

Continental Industries STEEL SERVICE TEES or FAX Visit

Owners Manual Bottle Filler Freeze Resistant Tubular Fountain & Pet Fountain with 98837C Dual Valve Control Assembly

TECHNICAL DATA CAUTION

TANK MATE INCLUDES: TOOLS REQUIRED: CONRADER VALVES 3/4 WRENCH **TUBING CUTTERS TEE PETCOCK TEE ASSEMBLY 8 FOOT NYLON TUBING

TECHNICAL DATA CAUTION

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50)

Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia

Pressure Dump Valve Service Kit for Series 3000 Units

DS06D,G Dial Set Pressure Regulating Valve

Instruction Manual O-Ring Ejector Chlorine & Sulfur Dioxide to 500 PPD (10 kg/h)

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

TECHNICAL DATA. Trimpac 257a. September 16, 2013

DS05C,D,G Dial Set Pressure Regulating Valves

AIR DISTRIBUTOR. PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB

Operation Manual Piston Sensed Gas Pressure Regulators

Pressure Balance Trim

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.

G92 Series BASOTROL Automatic Pilot Gas Valve

Installation Instructions for NP100 Series Nitrogen Control Panels

V46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

Flow Material Length. Weight GPM LPM. Style 3095

Continental Industries TRANSITION FITTINGS or FAX Visit

CAPITAL CONTROLS SERIES NXT3000

-FRU FREEZE RESISTANT WATER VALVE COOLERS SYSTEM

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

Float Operated Level Controllers

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

Design DSA Steam-Atomized Desuperheater

Sterisil Ac+ Installation & Operating Manual

Installation and Maintenance Manual. Compact Medical Gas Outlets

TECHNICAL DATA DELUGE VALVE, MODEL F-1 STRAIGHT THROUGH STYLE

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

TECHNICAL DATA. Trimpac 256a. October 31, 2013

How Do I Install My Garden Master Bucket Garden?

MIDDLESEX COUNTY COLLEGE EDISON, NJ LOCAL SUPPLIER BLANKET ORDER SPECIFICATIONS

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

TECHNICAL INSTRUCTIONS

Installing ASI Umbilical Delivery Systems

Model VR6 System. Installation, Operation & Maintenance

ETL listed for installations within 5 ft. (1.5M) of outer edge of water

265 Series Valve Operation Manual

Chlorinator. MODEL C-731 (Floor Mounted)

V146 Series 2-Way Pressure-Actuated Water-Regulating Valves

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Aquor House Hydrant V2

SO 9001 I ACCESSORIES

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

GENERAL DESCRIPTION MODEL RCW DRY SYSTEM CONFIGURATION. Technical Support Airpark Dr. Standish, MI 48658

GM Series Dual-Block Multi-Function Gas Control Valves

CO2 Tank Conversion Kit P.N , P.N , and P.N

CentriFlow Meter Integrated Air Entrainment System

Combination Air Valve Model

Your safety and the safety of others are very important.

D05T Compact Design Pressure Regulating Valves

Engineering Excellence. Installation Guide

table of contents bath accessories Cable Drains...19 Cover Plates Drains Drain Conversion Kits...20

Transcription:

Owners Manual Models 4430F3, 4430F2 & 4430F1 Floor Mounted Tri-Level ottle Filling Tubular Fountain MODEL 4430F1L MODEL 4430F2UM INSTALLER 4430F Fountains are among the easiest to install Fountains on the market today. To assure you install these models easily and correctly, PLEASE READ THESE SIMPLE INSTRUTIONS EFORE STARTING THE INSTALLATION. HEK YOUR INSTALLATION FOR OMPLIANE WITH PLUMING, ELETRIAL, AND OTHER APPLIALE ODES. After installation, leave these instructions with the Fountain for future reference. IMPORTANT ALL SERVIE TO E PERFORMED Y AN AUTHORIZED SERVIE PERSON IMPORTANT! INSTALLER PLEASE NOTE. MODEL 4430F3 THE GROUNDING OF ELETRIAL EQUIPMENT SUH AS TELEPHONE, OMPUTERS, ET. TO WATER LINES IS A OMMON PROEDURE. THIS GROUNDING MAY E IN THE UILDING OR MAY OUR AWAY FROM THE UILDING. THIS GROUNDING AN AUSE ELETRIAL FEEDAK INTO A FOUNTAIN, REATING AN ELE- TROLYSIS WHIH AUSES A METALLI TASTE OR AN INREASE IN THE METAL ONTENT OF THE WATER. THIS ONDITION IS AVOIDALE Y USING THE PROPER MATERIALS AS INDIATED. ANY DRAIN FITTINGS PROVIDED Y THE INSTALLER SHOULD E MADE OF PLASTI TO ELETRIALLY ISOLATE THE FOUNTAIN FROM THE UILDING PLUMING SYSTEM. PAGE 1 98646 (Rev. - /)

O " 305mm.. O 1/2" 13mm HOLES (6 PL) O 10" 254mm O 14" 356mm 48" 19mm 64" 1626mm 57" 1448mm 30" 762mm 37" 940mm 27" 686mm 1-1/2" DRAIN A 8" 203mm 7 /16" 201mm FINISHED FLOOR LEGEND A = 3/8" O.D. UNPLATED OPPER TUE ONNET - SHUT OFF VALVE Y OTHERS = AESS PANEL ( 8" X 10" ) = REMOVALE OTTOM OVER 52 1/8" 13mm 44" 1118mm 22 1/8" 562mm 32 1/8" 816mm 4430F3 98646 (Rev. - /) PAGE 2

O " 13mm 305mm.. O 1/2" HOLES (6 PL) O 10" 254mm O 14" 356mm 48" 19mm 57" 1448mm 41 9/16" 1056mm ORIFIE HEIGHT 52 1/8" 13mm 30" 762mm 37" 940mm 40 5/16" 10mm 27" 686mm 1-1/2" DRAIN A 22 1/8" 562mm 32 1/8" 816mm 8" 203mm 7 /16" 201mm FINISHED FLOOR ATUAL PRODUT ONFIGURATION MAY VARY ASED ON MODEL ORDERED. LEGEND A = 3/8" O.D. UNPLATED OPPER TUE ONNET - SHUT OFF VALVE Y OTHERS = AESS PANEL ( 8" X 10" ) = REMOVALE OTTOM OVER 4430F2ML PAGE 3 98646 (Rev. - /)

O " 13mm 305mm.. O 1/2" HOLES (6 PL) O 14" 356mm 48" 19mm 44" 1118mm 64" 1626mm 30" 762mm 34 7/16" 875mm ORIFIE HEIGHT 33 5/16" 846mm 1-1/2" DRAIN A 28 7/16" 7mm 29 3/4" 756mm ORIFIE HEIGHT 27" 686mm 22 1/8" 562mm 8" 203mm 7 /16" 201mm FINISHED FLOOR ATUAL PRODUT ONFIGURATION MAY VARY ASED ON MODEL ORDERED. LEGEND A = 3/8" O.D. UNPLATED OPPER TUE ONNET - SHUT OFF VALVE Y OTHERS = AESS PANEL ( 8" X 10" ) = REMOVALE OTTOM OVER O 10" 254mm 4430F1U 98646 (Rev. - /) PAGE 4

1. This fountain is to be mounted on a smooth, flat, finished surface with adequate support structure. NOTE: Mounting structure must be capable of supporting 300 lb. load on fountain. 2. Refer to rough-in for plumbing. 3. Install shut-off valve on water supply. (Valve not furnished) 4. Locate and install fountain using 3/8" minimum screws or bolts, (Screws or bolts not furnished). 5. Prior to installing the bottle filler to the center mounting position of fountain, insert drain pipe (Item #10) by positioning the short end of drain pipe through mounting plate of bottle filler. Install bottle filler to fountain and secure with supplied hardware. 6. Prior to installing the bottle to the arm mount of fountain, insert the drain pipe (Item #11) into the arm tunnel and adjust drain to lean to the left side of the arm when facing the button. Install bottle filler to arm being sure drain tube is above mounting plate of filler. Secure filler to fountain with supplied hardware. 7. onnect fountain to supply line with a shut-off valve and install a 3/8" unplated copper water line between the valve and the cooler. Remove any burrs from outside of water line. Push the tubes straight into the fittings until they reach a positive stop, approximately 3/4" (See Fig. 2). DO NOT SOLDER TUES INSERTED INTO PLASTI FITTINGS AS DAMAGE TO THE O-RINGS MAY RESULT. 8. Water supply 3/8" O.D. unplated copper tube. Waste 1-1/2" IPS. ontractor to supply waste trap and service stop valve in accordance with local code. 9. onnect water supply and fountain drain. onnect drain waste "Tee" to fountain drain tubes. onnect outlet of "Tee" to drainage system. Water connection and drain must comply with local codes. 10. Turn on water supply and check all connections for leaks. Threaded drain fittings may require thread sealer to create a leak free connection. Apply thread sealer to threaded connection fittings only, not the slip connection fittings. AUTION: This fountain is rated for inlet water pressure of 20-105 PSI. A pressure reducing regulator should be used if the inlet water supply exceeds 105 PSI. Any damage caused by reason of connecting this product to supply line pressures lower than 20 psig or higher than 105 psig is not covered by warranty. 11. onnecting lines to be made of unplated copper and should be thoroughly flushed to remove all foreign matter before being con nected to fountain. This fountain is manufactured in such a manner that it does not in any way cause taste, odor, color, or sediment problems. TROULE SHOOTING AND MAINTENANE Actuation of Quick onnect Water Fittings: Fountain is provided with lead-free connectors which utilize an o-ring water seal. To remove tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the tubing.(see Fig.2) To insert tubing, push tube straight into fitting until it reaches a positive stop, approximately 3/4". FIG. 2 FIG. 3 1/4" O.D. TUE WATER INLET TO OOLER FIG. 1 3/8" O.D. UNPLATED OPPER TUE ONNET OLD WATER SUPPLY UILDING WATER INLET NOTE: WATER FLOW DIRETION SERVIE STOP (NOT FURNISHED) STREAM HEIGHT ADJUSTMENT: Stream height is factory set at 35 PSI. If supply pressure varies greatly from this, insert a small straight bladed screwdriver through the access hole in the center of the push button and turn the adjustment screw. lockwise adjustment will raise the stream and counterclockwise adjustment will lower the stream. For best adjustment, the stream should be approximately 1 1/2" above the top of the bubbler. (See Fig. 3) PAGE 5 98646 (Rev. - /)

14 & 2 & 19 & 17 19 18 & 25 26 21 4 11 10 1 4 1 20 21 3 4 5 13 or 16 1 22 5 9 20 13 or 16 13 or 16 6 9 20 22 6 98646 (Rev. - /) PAGE 6

ITEM NO. 1 2 3 4 5 6 7 8 9 10 11 13 14 16 17 18 19 20 21 22 25 26 ITEMIZED PARTS LIST PART NO. DESRIPTION 28467 28955 40551 45464 45832 45833 45734 55996 66346 668 66816 98118 98530 98532 98677 98678 98679 98680 98681 98682 98683 98684 98685 98686 P05031 45931 asin over - Round Plate Tailpipe Drain Plug 1-1/2" Access Panel ottom over Drain Tube In - Line Strainer Drain Tube Tube - Drain Tube - Drain (Arm Only) ubbler Assembly Kit - Regulator W/Spring Kit - "O" Rings and Fittings Kit - Gasket Kit - 1.0 GPM Regulator (F Only) Kit - Nozzle Kit - Aerator Kit - ottle Filler Trim Kit - Push utton Kit - Plastic Drain Kit - 90 Plastic Drain Kit - 4400 Series Hardware Kit - ottle Filler Waterway Aerator Outdoor ottle Filler Drain Plug See Fig. 4 8 8 5 7 8 FIG. 4 PRINTED IN U.S.A. FOR PARTS ONTAT YOUR LOAL DISTRIUTOR OR ALL 1.800.260.6640 PAGE 7 98646 (Rev. - /)

THIS PAGE WAS LEFT INTENTIONALLY LANK 98646 (Rev. - /) PAGE 8