Float valves Types SV 1 and SV 3

Similar documents
Modulating liquid level regulators, direct-controlled, type SV 1 and 3 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Float valves Types SV 4, SV 5 and SV 6

Shut-off Liquid level and regulating valves for for Industrial Refrigeration

Liquid level regulating valves Types PMFL / PMFH and SV

Modulating liquid level regulators, servo-controlled PMFL / PMFH and SV

Safety relief valves Type SFA 15 and SFA 15-50

Pressure regulating valves Types OFV, OFV-SS

Safety relief valves Type SFV 20-25

2-step solenoid valve Type ICLX

Solenoid valves, two-step on/off Type PMLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Safety relief valves, type SFA 15 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Safety relief valves SFV 20-25

Safety relief valves Type BSV-8

2-step solenoid valve Type ICLX

for for Industrial Refrigeration

Crankcase pressure regulator, type KVL REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Solenoid valve type EVR for Hydrocarbons

Dual position solenoid valve Type ICSH 25-80

Pilot valves for pilot operated servo valves

Hand-operated regulating valves in stainless steel Types REG-SA SS and REG-SB SS

Safety relief valves, type BSV 8 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Safety relief valves, type SFA 15

Overflow valves Type OFV Type OFV-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Evaporator pressure regulator Type KVP

Shut-off valve Type QDV

Overflow valves Type OFV REFRIGERATION AND AIR CONDITIONING. Technical leaflet

MAKING MODERN LIVING POSSIBLE. Pilot operated internal safety valves type POV REFRIGERATION AND AIR CONDITIONING DIVISION.

Solenoid Valves, one - or two step, on/off ICLX

Evaporator pressure regulator Type KVP

Hand operated regulating valves Types REG-SA and REG-SB

Capacities Valve Station, type ICF 15, 20, 25

CHECK VALVES APPLICATIONS

Electric expansion valves Types AKV 10, AKV 15 and AKV 20

Condensing pressure regulator, type KVR Differential pressure valve, type NRD

Condensing pressure regulator, type KVR Receiver pressure regulator, type NRD

Regulating valves Type REG 6-65 Type REG-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Regulating valves REG-SA and REG-SB

Water valve Type WVO. Data sheet MAKING MODERN LIVING POSSIBLE

Quick closing oil drain valve, type QDV 15 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Evaporating Pressure Regulating Valve Type KVQ REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Valve station ICF 15, ICF 20, ICF 25, ICF 50 and ICF 65

Liquid level glasses, type LLG REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Sales Office: Danfoss Expansion Valves. T*2 Range Order valve and orifice separately Range N -40 C to +10 C Without MOP

Differential pressure controls, Type MP 54, 55 and 55A

Technical leaflet. Pressure and Temperature Regulators. January 1999 RC.4X.B1.22. Danfoss A/S

Refrigeration and Air Conditioning Technical leaflet

Differential pressure switch MP 54, MP 55 and MP 55A

Selection of ICF made easy Save even more time with ICF

V43 Pressure Actuated Water Regulating Valve

Shut-off ball valve Type GBC

Pressure reduction controller (PN 16, 25, 40)

Reliable System Performance PM valves

Differential Pressure Control Types MP 54, MP 55 and MP 55A

Capacity regulator (hot gas bypass), type TUH/TCHE/TRHE REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Shut-off ball valve Type GBC

Capacity regulator (hot gas bypass)

Series V48. 3-Way Pressure Actuated Modulating Valves. Product Bulletin. Features. Pressure balanced design. Free movement of all parts

PRESSURE REDUCING VALVE RP45 (EN)

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Water. VAG DUOJET Automatic Air Valve Single-chamber type PN 10/16/25/40 - DN KAT-A 1912

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

Shut-off ball valve Type GBC

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

Seated valve for steam (PN 25)

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Pressure transmitters EMP 2

SIHI LPH-X - Liquid Ring Compressors

Industrial Refrigeration systems in Potentially Explosive Atmospheres (Hazardous area) ATEX 94/9/EC Directive [ATmosphères EXplosives]

CFC2. Float Control For Closed Tanks MODEL. Specifications. Dimensions (In Inches) Reservoir Connection 1" NPT (Typ. Both Ends 2 Places)

Series MG Mixing Tubes

Seated valve for steam (PN 25) VFS 2 2-way valve, flange

Hydraulic Accumulators with Back-Up Nitrogen Bottles

Pressure switch, Differential pressure switch and Thermostat RT-E

Pressure reducing valves Index

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

Technical Instructions Document No. CA2N4721E-P25 Rev. 1, February, Modulating Control Valve for Hot Gas Control.

Differential pressure switch / Lube oil protection control MP 54 and MP 55

PRESSURE REDUCING VALVE RP45 (ANSI)

SPECIFICATION // DATA SHEET WATER DRAIN VALVE AM SENSORS LTD AMS-S-084/DS/ (ISSUE 1)

CASH VALVE TYPE KP BACK PRESSURE VALVES

2-Port Seat Valves with Flange, PN 16

Radiator thermostats type RA2000, valve bodies type RA-FN (series D) and RA-G

Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42

Technical Data Sheet T 2025

SV5 Safety Valve Installation and Maintenance Instructions

Pressure controls for hydro carbons, zone II applications, Type KPE

Pressure controls, differential pressure controls type RT

Description. Functions. Technical data. Applications. Tests. On-Off 2 levels float control valve, closing at high level and opening at low level.

) for different types of systems Test of contact function The correct pressure control for your system

80% Less installation time with just two welds for fast and efficient installation.

Series V47 Temperature Actuated Modulating Valves

Pressure Reducing Valve for Steam Type 2333 A

Pressure switch and Thermostat CAS

Pressure switch RT. Data sheet

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

2 - way valve for steam, pressure relieved (PN 25) VGS - external thread

Pressure Reducing Valve for steam RP 45

AVP-F. p setting range (bar) Code No. 003H6200

Transcription:

Data sheet Float valves s SV 1 and SV 3 The SV 1 and 3 can be used separately as a modulating liquid level regulator in refrigerating, freezing and air conditioning systems for ammonia or fluorinated refrigerants. However, in most cases, the SV is used as a float pilot valve for the main expansion valve type PMFH. Technical data Refrigerant Applicable to HCFC, HFC and R717 (Ammonia). P band 35 mm Temperature of medium 50 to +65 C Max. working pressure PS = 28 bar Max. test pressure p' = 36 bar k v value for float orifice SV 1 = 0.06 m 3 /h SV 3 = 0. m 3 /h The highest k v value for the built-in throttle valve is 0.18 m 3 /h. The throttle valve can be used both in parallel and in series with the float orifice. Classification: DNV, CRN, BV, EAC etc. To get an updated list of certification on the products please contact your local Danfoss Sales Company. Approvals Pressure Equipment Directive (PED) SV1 and 3 are approved in accordance with the European standard specified in the Pressure Equipment Directive and are CE marked. Classified for Category SV1 and 3 Fluid group I I For further details / restrictions - see Installation Instruction Danfoss DCS (MWA).10 DKRCI.PD.GE0.B6.02 5H66 1

Identification Dimensioning example for SV (L) Refrigerant R717 (NH 3) Evaporating capacity Q e = kw Evaporating temperature t e = 10 C (~ p e = 2.9 bar abs.) Condensing temperature t c = +30 C (~ p c =.7 bar abs.) Liquid temperature for SV t l = + C Subcooling t sub = t c t l = 30 C C = 10 K Pressure drop in SV p = p c p e =.7 2.9 = 8.8 bar Correction factor k for 10 K subcooling 0.98 Corrected capacity 0.98 =.4 kw At t e = 10 C and p = 8 bar SV 1 yields kw and can therefore be used. If SV 3 is used for this capacity, it will mean a small offset. Ordering Regulator The code nos. stated apply to float valves, types SV 1 and SV 3 incl. 6.5 / 10 mm weld connection 1 ) for the pilot line. Balance tube connection (liquid/vapour): 1 in. weld / 1 1 / 8 in. solder. The rated capacity refers to the valve capacity at evaporating temperature t e = +5 C, condensing temp. t c = +32 C and liquid temperature t l = +28 C. Valve type Code no. Rated capacity in kw R717 R22 R4a R404A R R502 SV 1 0B21 25 4.7 3.9 3.7 3.1 3.4 SV 3 0B23 64 10.0 9.7 7.9 8.8 1 ) 3 8 in. flare connection can be supplied under code no. 0B. Spare parts and accessories See spare parts catalogue. Pipe dimensions Liquid line The following suggested dimensions for the liquid line, which is connected to the nipple pos. C, see "Design / Function", are based on a maximum velocity in a line with subcooled ammonia of approx. 1 m/s and a maximum velocity in a line with subcooled fluorinated refrigerant of approx. 0.5 m/s. 1. R717 (ammonia) Dimensions 0.8 bar < p sv < 4 bar 4 bar < p sv < 16 bar Steel tube Steel tube SV 1 3 / 8 in. 3 / 8 in. SV 3 3 / 8 in. 1 / 2 in. 2. R22, R4a, R404A Dimensions 0.8 bar < p sv < 4 bar 4 bar < p sv < 16 bar Steel tube Copper tube Steel tube Copper tube SV 1 3 / 8 in. 3 / 8 in. 3 / 8 in. 1 / 2 in. SV 3 3 / 8 in. 5 / 8 in. 1 / 2 in. 3 / 4 in. Upper balance pipe (connect to pos. D on SV (L) Dimensions SV (L) 1 1 in. SV (L) 3 1 1 / 2 in. Danfoss DCS (MWA).10 DKRCI.PD.GE0.B6.02 5H66 2

Capacity The values in the capacity tables are based on a subcooling of 4 K just ahead of the SV valve. If the subcooling is more or less than 4 K, refer to the following correction factors. Evaporating temperature t e C Capacity in kw at pressure drop across valve p bar 0.8 1.2 1.6 2 4 8 16 Evaporating temperature t e C Capacity in kw at pressure drop across valve p bar 0.8 1.2 1.6 2 4 8 16 R717 (NH 3 ) R22 SV 1 +10 0 10 30 40 50 9.5 9.9 10 21 21 30 30 30 29 29 32 32 SV 1 +10 0 10 30 40 50 2.2 2.3 2.4 2.4 2.5 2.5 2.6 2.6 2.7 2.8 2.9 2.9 2.9 2.9 3.0 3.1 3.2 3.3 3.3 3.3 3.3 3.2 3.4 3.5 3.6 3.6 3.6 3.5 4.2 4.4 4.5 4.6 4.5 4.4 4.3 4.8 4.9 5.0 5.0 5.0 4.9 4.8 5.7 5.7 5.6 5.4 5.7 5.9 5.7 5.6 5.4 SV 3 +10 0 10 30-40 50 25 25 24 23 32 32 30 29 35 36 36 35 34 39 40 40 39 38 36 35 52 52 52 52 50 49 47 71 69 68 67 66 65 64 77 78 77 76 75 73 71 83 83 82 82 80 79 SV 3 +10 0 10 30-40 50 5.6 6.0 6.1 6.2 6.1 5.9 6.8 7.0 7.3 7.3 7.3 7.1 6.9 7.7 8.0 8.2 8.3 8.1 7.9 7.6 8.5 8.8 9.0 8.9 8.8 8.5 8.2 Correction factors When dimensioning, multiply the evaporator capacity by a correction factor k dependent on the subcooling t sub just ahead of the valve. The corrected capacity can then be found in the capacity table. R717 (NH3) t K 2 4 10 25 30 35 40 45 50 k 1.01 1.00 0.98 0.96 0.94 0.92 0.91 0.89 0.87 0.86 0.85 R22 t K 2 4 10 25 30 35 40 45 50 k 1.01 1.00 0.96 0.93 0.90 0.87 0.85 0.83 0.80 0.78 0.77 Danfoss DCS (MWA).10 DKRCI.PD.GE0.B6.02 5H66 3

Design Function SV with low-pressure function C. Nipple D. Connection for balance pipe P. Parallel connection of pos. C (screw 17 in pos. A) S. Series connection of pos. C (screw 17 in pos. B) No. Part Material DIN / EN 1 Float housing Stainless steel Low temperature, steel 2 Float Stainless steel 3 Split pin Steel 4 Float arm Stainless steel 5 Link Steel 6 Pin Stainless steel 7 Valve housing Steel 8 O-ring Cloroprene (Neoprene) 9 Float orifice Plastic 10 Manual regulation unit. Throttle valve Steel Gasket Non asbestos Plug Steel O-ring Cloroprene (Neoprene) Pilot connection (spare part) Steel Orifice needle Plastic 16 O-ring Cloroprene (Neoprene) 17 Screw Steel 18 Gasket Non asbestos 19 Pin Steel Cover Low temperature, cast iron (spherical) 21 Screw Stainless steel A2-70 22 Gasket Non asbestos 23 Label Cardboard 25 Screw Steel Spring washer Steel 28 Sign Aluminium X5CrNi18-10, DIN 17440 P285QH, EN 10222-4 EN-GJS-400-18-LT EN 63 Danfoss DCS (MWA).10 DKRCI.PD.GE0.B6.02 5H66 4

Design Function (continued) SV (L), low-pressure function SV (L) is used for small, flooded evaporators, where only slight variations in the liquid level can be accepted. When the liquid level falls, the float pos. (2) moves downwards. This draws the needle pos. () away from the orifice and the amount of liquid injected is increased. The liquid inlet line, which is mounted on the nipple pos. (C), should be dimensioned in such a way that acceptable liquid velocities and pressure drops are obtained. This is particularly important when the liquid is only slightly subcooled, since valve capacity is reduced considerably if flashgas occurs in the liquid ahead of the orifice and wear is strongly increased. See the suggested dimensions for the liquid line in "Pipe dimensions". The flashgas quantity which occurs on expansion is removed through the balance pipe from pos. (D). On refrigeration plant using fluorinated refrigerants, slight subcooling and a large pressure drop can give a flashgas quantity of approx. 50% of the injected liquid quantity. Therefore the pressure drop in this balance pipe must be kept at a minimum, since there will otherwise be a risk that the liquid level in the evaporator will vary to an unacceptable degree as a function of evaporator load the absolute difference between the liquid level of the evaporator and the SV valve will be too large. See the suggested dimensions for the balance pipe in "Pipe dimensions". Danfoss DCS (MWA).10 DKRCI.PD.GE0.B6.02 5H66 5

Design Function (continued) SV with high-pressure function C. Nipple D. Connection for balance pipe P. Parallel connection of pos. C (screw 17 in pos. A) S. Series connection of pos. C (screw 17 in pos. B) No. Part Material DIN / EN 1 Float housing Stainless steel Low temperature, steel 2 Float Stainless steel 3 Split pin Steel 4 Float arm Stainless steel 5 Link Steel 6 Pin Stainless steel 7 Valve housing Steel 8 O-ring Cloroprene (Neoprene) 9 Float orifice Plastic 10 Manual regulation unit. Throttle valve Steel Gasket Non asbestos Plug Steel O-ring Cloroprene (Neoprene) Pilot connection (spare part) Steel Orifice needle Plastic 16 O-ring Cloroprene (Neoprene) 17 Screw Steel 18 Gasket Non asbestos 19 Pin Steel Cover Low temperature, cast iron (spherical) 21 Screw Stainless steel A2-70 22 Gasket Non asbestos 23 Label cardboard 25 Screw Steel Spring washer Steel 28 Sign Aluminium X5CrNi18-10, DIN 17440 P285QH, EN 10222-4 EN-GJS-400-18-LT EN 63 Danfoss DCS (MWA).10 DKRCI.PD.GE0.B6.02 5H66 6

Design Function (continued) SV (H), high-pressure function SV (H) is used as a liquid level regulator for small condensers or receivers. When the liquid level rises, the float pos. (2) moves upwards. This draws the needle pos. () away from the orifice and the excess liquid is drawn away. On refrigeration plant using fluorinated refrigerants slight subcooling and a large pressure drop can, as already mentioned, cause the formation of a large amount of flashgas. This mixture of liquid and vapour has to pass through the nipple pos. (C) and out into the liquidline. If the dimensions of the line are too small, a pressure drop will occur which can reduce the capacity of the SV (H) valve considerably. This will mean a risk of inadvertent liquid accumulation in the condenser or receiver. See the suggested dimensions for the liquid line in "Pipe dimensions". The connection nipple (C) can be mounted either in P or in S. P-connection P-connection (= parallel) With P-connection an SV with closed float orifice will have a capacity which corresponds to the degree of opening of the adjustable throttle valve 10. S-connection S-connection (= series) With S-connection the throttle valve 10 will function as a pre-orifice on SV (L) and as a post orifice on SV (H). SV 1-3 used as a high pressure defrost drain float valve SV 1-3 can be used as a defrost drain float valve, when one balance pipe is sealed off and the liquid level regulator is mounted with a special kit (code no. 0B54) consisting of: Special orifice and orifice needle with a larger k v-value of 0.28 m 3 /h. Gas drain pipe Liquid out to wet suction Condensed liquid in from evaporator SV 1-3 fitted with the special kit Danfoss DCS (MWA).10 DKRCI.PD.GE0.B6.02 5H66 7

SV 1-3 used as a high pressure defrost drain float valve (continued) Application example Wet suction line PMLX Liquid line Hotgas line SV 1-3 with special kit mounted as defrost drain float valve on a flooded evaporator with hotgas defrost. Dimensions and weight SV 1 and SV 3 Weight 5.7 kg Danfoss DCS (MWA).10 DKRCI.PD.GE0.B6.02 5H66 8