Journal of Exercise Physiologyonline

Similar documents
Journal of Exercise Physiologyonline

Using Hexoskin Wearable Technology to Obtain Body Metrics During Trail Hiking

Journal of Exercise Physiologyonline

Journal of Exercise Physiologyonline (JEPonline)

Journal of Exercise Physiologyonline

JEPonline Journal of Exercise Physiologyonline

Comparison of the Effect of Caffeine Ingestion on Time to Exhaustion between Endurance Trained and Untrained Men

An Examination of the Effects of a Curriculum Based Pedometer Program in Two Age Groups: Adults and Pre-Adolescent Children

Journal of Exercise Physiologyonline

Effect of walking speed and placement position interactions in determining the accuracy of various newer pedometers

Journal of Exercise Physiologyonline (JEPonline)

HHS Public Access Author manuscript Int J Cardiol. Author manuscript; available in PMC 2016 April 15.

Objective Physical Activity Monitoring for Health-Related Research: A Discussion of Methods, Deployments, and Data Presentations

Journal of Human Sport and Exercise E-ISSN: Universidad de Alicante España

Journal of Exercise Physiologyonline

Journal of Exercise Physiologyonline (JEPonline)


Validation of a Step Test in Children Ages 7-11

Effects of Age and Body Mass Index on Accuracy of Simple Moderate Vigorous Physical Activity Monitor Under Controlled Condition

Article published in: ACSM s Medicine & Science in Sports & Exercise Vol. 27, No. 4, April 1995

VALIDATION OF THE PHYSICAL ACTIVITY INDEX (PAI) AS A MEASURE OF TOTAL ACTIVITY LOAD AND TOTAL KILOCALORIE EXPENDITURE

TRAINING WITH! PHYSICLO RESISTANCE GEAR. Testing & Validation

Evaluation of a commercially available

Fitbit s 100+ Billion Hours of Resting Heart Rate User Data Reveals Resting Heart Rate Decreases After Age 40

EXAMINING THE RELABILITY AND VALIDITY OF THE FITBIT CHARGE 2 TECHNOLOGY FOR HEART RATE DURING TREADMILL EXERCISE

Four-week pedometer-determined activity patterns in normal-weight, overweight. and obese adults

Validity of wrist-worn consumer products to measure heart rate and energy expenditure

The running economy difference between running barefoot and running shod

Comparison of Accuracy Among Pedometers from Five Japanese Manufacturers

Anaerobic and aerobic contributions to 800 m and 8 km season bests

How Running Barefoot (Xero Shoes) and Running Shod (Montrail Shoes) Effects Percent of Maximum Heart rate - A Case Report

INFLUENCE OF PEDOMETER TILT ANGLE ON STEP COUNTING VALIDITY DURING CONTROLLED TREADMILL WALKING TRIALS. Melissa Dock

Comparison of Energy Expenditure during Walking between Female Athletes and Non-Athletes

Current State of Commercial Wearable Technology in Physical Activity Monitoring

This study investigated the amount of physical activity that occurred during

Journal of Exercise Physiologyonline

WALK WITH A DOC 2017 EVALUABILITY ASSESSMENT

Pedometers: Answers to FAQs from Teachers

Just Start Walking! Improve your health and fitness in as little as 20 minutes a day!

Leg Power in Elite Male Fencers: A Comparative Study among the Three Competitive Disciplines

How Running Barefoot (Xero Shoes) and Running Shod (Montrail Shoes) Effects Percent of Maximum Heart rate - A Case Report

Validation and Comparison of Two Ankle- Mounted and Two Waist-Mounted Electronic Pedometers

Using Accelerometry: Methods Employed in NHANES

Journal of Exercise Physiologyonline

Validity of Four Activity Monitors during Controlled and Free-Living Conditions

In Australia, survey instruments for the

Methods. Mark A. Tully and Margaret E. Cupples. Study Design

Equipment Testing and Validation ASSESSMENT OF FRACTIONAL EXPIRED GASES AND AIR FLOW BY AN AMBULATORY METABOLIC ANALYZER

Health and Community Design: The Local Government Role in Promoting Active Living

A CROSS-SECTIONAL ANALYSIS OF SKILL RELATED PHYSICAL FITNESS COMPONENTS OF KAYAKING AND ROWING PLAYERS

Walking for Heart Health in Rural Women

The estimation of energy expenditure (EE) is of interest

Monitoring of performance an training in rowers

The Effect of the Arm Swing on the Heart Rate of Non-Athletes


Health & Fitness Journal

External Feedback Does Not Affect Running Pace in Recreational Runners

Effects of Placement, Attachment, and Weight Classification on Pedometer Accuracy

Assessment of an International Breaststroke Swimmer Using a Race Readiness Test

COMPARISON OF PHYSIOLOGICAL VARIABLES AND BODY COMPOSITION VARIABLES AMONG WALKING TYPES ON TREADMILL

Heart rate response to a climber s fall in sport climbing

Validation of PiezoRx Pedometer Derived Sedentary Time

OLYMPIC YEAR IMPACT ON LEISURE-TIME PHYSICAL ACTIVITY RATES WITHIN AND ACROSS CANADIAN PROVINCES AND TERRITORIES

Pedometer-Determined Physical Activity Levels of Youth

Are Active Australia physical activity questions valid for older adults? Running Head: Are questions valid?

accelerometer for running, race walking, and

References PEDOMETER PULSOMETER

Presence and duration of reactivity to pedometers in adults

By Seth Schutte, John Amtmann, Harris Cody and William Spath. Intermountain Journal of Sciences

Journal of Exercise Physiologyonline

Richard J Jackson MD, MPH, FAAP.

Evaluation of pedestrians speed with investigation of un-marked crossing

Accurate assessment of physical activity (PA) in a

Aerobic Capacity. Need Additional Resources?

Does wearing a wrist guard affect the site of wrist fracture in snow sports?

Validity of the iphone 5S M7 motion co-processor. as a pedometer for able-bodied persons. Micah Alford 9/7/2014

Title: Agreement between pedometer and accelerometer in measuring physical activity in overweight and obese pregnant women

A Description of Variability of Pacing in Marathon Distance Running

Medicine. Cadence Feedback With ECE PEDO to Monitor Physical Activity Intensity. A Pilot Study. Fusun Ardic, MD and Esra Göcer, MD

Health Beyond Healthcare The Chronic Disease Impacts of Neighborhood Design. Erik J. Aulestia, AICP Principal, Torti Gallas + Partners

Built Environment Childhood Obesity Forum September 15, 2010

SUPPLEMENTARY INFORMATION

Eric Thomas Garcia. A Thesis Submitted to the Faculty of Graduate Studies of. The University of Manitoba

VALIDITY OF SELECTED CARDIOVASCULAR FIELD-BASED TEST AMONG MALAYSIAN HEALTHY FEMALE ADULT. S. H. Azmi 1,*, and N. Sulaiman 2

Target population involvement in urban ciclovias: a preliminary evaluation of St. Louis Open Streets

Prevalence of Total Daily Walking Among US Adults,

USING WIRELESS PEDOMETERS TO MEASURE CHILDREN S PHYSICAL ACTIVITY: HOW RELIABLE IS THE FITBIT ZIP TM?

Oral versus Nasal Breathing during Moderate to High Intensity Submaximal Aerobic Exercise

Health + Track Mobile Application using Accelerometer and Gyroscope

Comparative Effectiveness of Two Walking Interventions on Participation, Step Counts, and Health

The Built Environment and Obesity

Journal of Exercise Physiologyonline

The effects of backpack loading styles on energy expenditure and movement in the sagittal plane during treadmill walking

Physical activity during recess outdoors and indoors among urban public school students, St. Louis, Missouri,

Achieving 10,000 steps: A comparison of public transport users and drivers in a University setting

Speed Training. Speed Training

The Basis for Prescribed Ability Group Run Speeds and Distances in U.S. Army Basic Combat Training

Accuracy of a Pedometer and an Accelerometer in Women with Obesity

#10 Work Physiology. By : Dewi Hardiningtyas, ST., MT., MBA. Industrial Engineering Dept. University of Brawijaya

The Effects of Chronic Creatine Supplementation on Performance and Body Composition of Female Athletes. by Megan Brenner

Transcription:

134 Journal of Exercise Physiologyonline October 2017 Volume 20 Number 5 Editor-in-Chief Official Research Journal of Tommy the American Boone, PhD, Society MBA of Review Exercise Board Physiologists Todd Astorino, PhD Julien Baker, ISSN 1097-9751 PhD Steve Brock, PhD Lance Dalleck, PhD Eric Goulet, PhD Robert Gotshall, PhD Alexander Hutchison, PhD M. Knight-Maloney, PhD Len Kravitz, PhD James Laskin, PhD Yit Aun Lim, PhD Lonnie Lowery, PhD Derek Marks, PhD Cristine Mermier, PhD Robert Robergs, PhD Chantal Vella, PhD Dale Wagner, PhD Frank Wyatt, PhD Ben Zhou, PhD Official Research Journal of the American Society of Exercise Physiologists ISSN 1097-9751 JEPonline Fitbit Flex: Energy Expenditure and Step Count Evaluation Jeffrey Montes, John C. Young, Richard Tandy, James W. Navalta Department of Kinesiology and Nutrition Sciences, University of Nevada, Las Vegas, Las Vegas, NV, USA ABSTRACT Montes J, Young JC, Tandy R, Navalta JW. Fitbit Flex: Energy Expenditure and Step Count Evaluation. JEPonline 2017;20(5):134-140. Energy expenditure (EE) and step count (SC) was measured with a Fitbit Flex wrist-worn activity tracker (FWAT) during a two-day walking protocol. Forty-nine volunteers participated on day 1, 46 on day 2, 31 were used for reliability. Participants walked for 3 min at 1.5, 2.5, and 3.5 mph at 0% grade on both days. An Applied Electrochemistry MOXUS Metabolic System (MX) with steps counted was the baseline comparison. Data was analyzed using dependent t-tests (P<0.05) and Cronbach s α ( 0.70). For EE; (1.5 mph; P<0.01, Standard Error(SE): FWAT 19.43 ± 0.73; MX 11.9 ± 0.32, α=0.56. 2.5 mph; P<0.01, SE: FWAT 25.0 ± 0.75; MX 14.43 ± 0.38, α=0.72. 3.5 mph; P<0.01, SE: FWAT 27.2 ± 0.77; MX 19.43 ±.049, α=0.67). For SC; (1.5 mph; P<0.01, SE: FWAT 231 ± 6.02; MC 269 ± 2.58, α=0.55. 2.5 mph; P=0.03, SE: FWAT 323 ± 4.39; MC 332 ± 2.18, α=0.50. 3.5 mph; P<0.01, SE: FWAT 366 ± 3.22; MC 380 ± 2.21, α=0.66). The FWAT significantly overestimated EE with reliability at 2.5 mph and significantly underestimated SC without reliability at any speed. Key Words: Fitbit, Physical Fitness, Walking, Wearable Technology

135 INTRODUCTION Statistics from the Center for Disease Control (CDC) estimate that 23.7% of the adult population engages in no leisure physical activity, 27.1% of the adults are physically active daily, 28.9% are obese, and 35.2% are overweight. The yearly healthcare cost for physical inactivity is estimated to be $117 billion with the inactive adults paying approximately $1,437 more than the physically active adults (2). The American College of Sports Medicine (ACSM) recommends all persons do at least 30 min of moderate-intensity physical activity on at least 5 d wk -1 (8). Monitoring daily step counts (SC) can be a useful tool for evaluating daily physical activity, health, and wellness. To accomplish this, one of the more common activities is the accumulation 10,000 daily steps. By comparison, the average daily SC for the general population is 6,000 to 7,000 steps. Choi et al. (3) indicate that performing a 30-min walk at a moderate intensity could add another 3,000 to 4,000 steps. The additional walking, according to Tudor-Locke and Bassett (16), was found to assist persons in leading a healthier lifestyle. A longitudinal study by Moreau et al. (12) gave additional evidence that increasing daily SC to ~10,000 steps a day reduced systolic BP in hypertensive women by ~11 mmhg and body mass by ~1.3 kg after a 24-wk interval of daily walking. An activity Tracker (AT) that can accurately measure daily SC with a hard step count value could consistently prompt the wearer of how near they are to their daily fitness goals. In addition, the AT can provide a psychological boost by encouraging the wearer to increase SC when the daily count is lower than anticipated. This may cause an increase in physical activity by prompting the user to perform activities such as using stairs instead of elevators or walking to nearby stores rather than driving. Devices that measure exercise related data such as SC and energy expenditure (EE) have become popular with the fitness community with wearable technology being the number one trend in exercise for 2016 (14). The use of wrist-worn devices has become a favorite with persons due to the low cost ($10 to $160) and user friendliness of the devices (15). Also, because they are small and non-intrusive, they do not impair the user during daily activities (4). However, the accuracy and consistency of most physiological measuring devices have yet to be fully evaluated. To be considered beneficial to a user, certain criteria need to be met. First, it must measure what it claims to measure within an acceptable range. Second, it must be consistent. Third, it must be financially reasonable and user friendly. Fourth, its use should minimally alter the behavior of the user as to not influence its measurement (6). The FitBit Flex (FWAT) is a reasonably priced AT ($79.95) that is simple to use and understand (5). However, previous research has indicated that similar wrist worn devices are inaccurate when users walk at speeds of approximately 2.0 mph and slower (7,11). This inaccuracy can lead to incorrect estimations of physical activity and calculations of calories expended. The purpose of this study was to evaluate significant mean differences and reliability measures for FWAT EE and SC values. We hypothesized that the FWAT measurements for EE and SC at all three speeds would: (a) not be significantly different from MX derived EE

values and a manual count of steps; and (b) be reliable using the same time/day/conditions 1 to 2 wks later. METHODS Subjects Forty-nine participants (26 males, 23 females, age 23.4 ± 6.6 yrs; height 172.1 ± 11 cm; weight 76.2 ± 18.5 kg) were recruited from the University of Nevada, Las Vegas student and faculty populations. All subjects completed an approved institutional review board (protocol number 1408-4894), informed consent, and an American College of Sports Medicine (ACSM) health risk questionnaire prior to beginning the first treadmill walk. Body composition was evaluated for all subjects with a bio-impedance device (TBF-521 Body Fat Monitor/ Scale, Tanita, Arlington Heights, IL, USA). Body Mass Index (BMI) was determined by the formula [(Weight (lbs) x 703 / Height 2 (in)]. Forty-six of the original subjects (24 males, 22 females, age 23.4 ± 6.7 yrs; height 172.1 ± 11 cm; weight 76.5 ± 18.7 kg) returned for the second treadmill walk. The data from 31 subjects (18 males, 13 females, age 24.4 ± 7.6 yrs; height 173.0 ± 10 cm; weight 78.0 ± 21.5 kg) were used for reliability as they retested 1 to 2 wks later at the same time and on the same day of the week as the first walk. Procedures The subjects anthropologic data (gender, age, height, and weight) for the FWAT was entered via an ipad (Apple, mini 2, Cupertino, CA. USA). Subjects were instructed to stand on a treadmill (T9.14, Nautilus, Vancouver, WA, USA) while they were connected to a respiratory cart (Applied Electrochemistry MOXUS Metabolic System, Bastrop, TX, USA) (MX) by use of hoses, head harness, mouthpiece, and nose plugs. A FWAT (Fit Bit Inc, San Francisco, CA, USA) was placed on their right wrist. The MX and a manual SC provided baseline data. The FWAT values were displayed on the ipad for real time viewing. All subjects performed a treadmill walking protocol. The protocol consisted of three distinct stages of walking at three different speeds. Each stage was separated by a rest interval that allowed for data collection and preparation for the next stage. Subjects began by walking at 1.5 mph at 0% grade for 3 min. After the rest interval, the speed was increased by 1.0 mph while the grade remained the same. This continued until the final stage of 3.5 mph was completed. The second day of walking used the same procedure. Statistical Analysis Significant mean differences and reliability for EE and SC were analyzed using IBM SPSS Statistics 23.0 software (IBM SPSS Statistics 23, IBM Corporation, Armonk, NY). Statistical significance was set at P<0.05. An α coefficient of 0.70 or higher was considered reliable. Energy expenditure and SC analysis used the values obtained for each speed s overall 3-min time interval. Both days walks were used for dependent t-test analysis (n = 95). Thirty-one paired walks were used to determine reliability (n = 31). The FWAT EE was compared to those calculated from the recorded MX data. The MX EE was determined by multiplying the absolute MX VO 2 value and the RER caloric equivalent for each 1, 2, and 3-min point and adding the three together. The FWAT SC was compared to the manual count of steps. β was set at 0.80. Effect size was calculated using G*Power statistical software (G*Power version 3.1.9.2, Universität Kiel, Kiel, Germany). At the time of this study, there was no previous 136

research data to calculate an n size. However, using the indicated α, β, and actual n, the calculated effect size for SC and EE was 0.29. RESULTS Significant mean differences were observed in all speeds for EE (1.5 mph Standard Error (SE); FWAT 19.43 ± 0.73; MX 11.9 ± 0.32) (2.5 mph SE; FWAT 25.0 ± 0.75; MX 14.43 ± 0.38) (3.5 mph SE; FWAT 27.2 ± 0.77; MX 19.43 ± 0.49) (Figure 1). One speed was reliable (1.5 mph α = 0.56, 2.5 mph = 0.72, 3.5 mph = 0.67) (Table 1). Significant mean differences were observed in all speeds with regards to SC (1.5 mph SE; FWAT 231 ± 6.02; MC 269 ± 2.58) (2.5 mph SE; FWAT 323 ± 4.39; MC 332 ± 2.18) (3.5 mph SE; FWAT 366 ± 3.22; MC 380 ± 2.21) (Figure 2). No speeds were reliable (1.5 mph α = 0.55, 2.5 mph = 0.50, 3.5 mph = 0.66) (Table 1). 137 Speed Energy Expenditure (Cronbach α) Step Count (Cronbach α) 1.5(mph) 0.56 0.55 2.5(mph) 0.72 0.50 3.5(mph) 0.67 0.66

138 DISCUSSION The purpose of this study was to determine if the FWAT accurately measures SC and EE and its consistency to do so. A simple walking protocol using 3-min stages at 3 speeds; 1.5 mph, 2.5 mph, and 3.5 mph; all at 0% grade was used to establish a pool of data for evaluation purposes. These speeds represented: (a) slower walking speeds (<2.5 mph) such as in elderly populations (13); (b) the general population (2.5 to 3.5 mph) (1); and (c) persons using walking as a means of exercise (>3.5 mph) (9). It was hypothesized that measurements taken by the FWAT for EE and SC at all three speeds would not be significantly different from MX derived EE values and a manual count of steps, respectively. It was hypothesized that measurements between both days walks would be reliable when compared to one another using the same conditions and time/day 1 to 2 wks later. The FWAT significantly overestimated EE for all three speeds. It was reliable only at 2.5 mph. It can be assumed that the FWAT uses its own SC value as a basis for EE calculations. By overestimating calories burned, it is likely that persons trying to count calories or evaluate potential weight loss will be using incorrect data. Because they believe they are burning more calories than they are, they may not see the weight loss that they are expecting over time. This can result in confusion or discouragement by the user. Given that the subjects only performed a 3-min walk at each speed and each resulted in higher than the actual calories burned, the use of the device over an entire day may give the user a final calorie count that is entirely too high. It has been reported that elderly adults spend 48 min each day being physically active (10). Utilizing our energy expenditure data for walking at 3.5 mph (which had the least difference between measurement devices), an elderly individual would be expected to burn 311 kcal d -1 through physical activity. However, the FWAT would lead them to believe that they had expended 435 kcal d -1, which is an overestimation of 29%. The difference in absolute calories expended would be conceivably higher as physical activity level increased. The FWAT significantly underestimated steps taken and was not reliable at any speed. One reason for this finding may be in the different mechanics involved when a person walks at slower speeds (1.5 mph) when compared to the faster speeds (such as 3.5 mph). The FWAT relies on motion to register what it considers a step. When walking at 1.5 mph, there was a noticeable reduction in the counter-motion swing in both arms. Also, the subjects appeared to have lower body leg movements that seemed unnatural, i.e. it appeared the slow speed forced them to deliberately concentrate on and purposefully place their feet when stepping to accommodate the slower speed instead of using their natural walking motion. Anecdotally, many subjects commented that the 1.5 mph walk was awkward and felt unnatural. These factors may have directly affected the FWAT SC value through these reduced movement patterns. However, even at the faster speeds (2.5 and 3.5 mph), although the differences between FWAT and manual count were not as great, the FWAT still returned a significantly lower mean value. This did not correspond to the previous literature that supports evidence that at speeds of approximately 2.0 to 2.5 mph, most SC devices are accurate (7). Additionally, the low reliability scores are curious. Based on the data, it is reasonable to conclude that the FWAT device is not reliable with respect to EE (except for at 2.5 mph) and SC. One factor that may have affected the reliability measurements could be a small learning effect where the unfamiliar movement patterns of walking so slow during the first bout were expected and adjusted for by subjects in the second bout performed 1 to 2 wks later. This

learning factor could have led to a better efficiency and a smoother movement pattern the second time. CONCLUSIONS Based on the results of this study, the FWAT does not accurately measure nor is it consistent in returning energy expenditure or step count measures. Because of this finding, the use of the FWAT device as a weight loss tool or an activity tracker should be treated with caution. Measurements of SC and EE cannot be directly accepted as valid for the user to confidently accept as actual scores. One positive trait that the FWAT does possess is its application for the creation of social groups. Adults who use this device can form interlinked groups with other FWAT users that allow all individuals in the group to observe daily activity scores. This sharing of daily activity data may lead to increased levels of daily activity in two ways. First, given that adults are generally competitive in nature, the daily comparison of steps taken or calories burned may inspire other adults to be more active simply to have higher scores than their peers. Second, not being active may lead to peer pressure. Adults who see that the user is not getting enough daily activity may initiate contact to get them more active. On the other hand, some adults may not want to let the other adults see their scores drop and, therefore, become more active simply to avoid being singled out. The best opinion that can be given for the FWAT device at this time is that it should be used as a psychological tool to motivate individuals to become more active. Even if the reported values are incorrect, there may be a level of self-induced motivation to become more physically active. 139 Address for correspondence: Jeffrey Montes, Department of Kinesiology and Nutrition Sciences, University of Nevada, Las Vegas, Las Vegas, NV, 89154 Email: jeffrey.montes @unlv.edu REFERENCES 1. Browning RC, Baker EA, Herron JA, Kram R. Effects of obesity and sex on the energetic cost and preferred speed of walking. J Appl Physiol. 2006;100(2):390-398. 2. Center for Disease Control and Prevention [CDC]. Overweight and Obesity: Disability and Risk Factors. 2016. (Online). http://www.cdc.gov/nchs/fastats/obesity-overweight. htm. 2016. 3. Choi BC, Pak AW, Choi JC, Choi EC. Daily step goal of 10,000 steps: A literature review. Clin Invest Med. 2007;30(3):146-15. 4. Clemes SA, Biddle SJH. The use of pedometers for monitoring physical activity in children and adolescents: Measurement considerations. J Phys Ac Health. 2013;10 (2):249-262. 5. Fitbit. (Online). https://www.fitbit.com/shop/flex. 2016

6. Laporte RE, Montoye HJ, Caspersen CJ. Assessment of physical activity in epidemiologic research: Problems and prospects. Public Health Reports. 1985;100 (2):131-146. 7. Leicht AS, Crowther RG. Pedometer accuracy during walking over different surfaces. Med Sci Sports Exer. 2007;39(10):1847-1850. 8. Liguori G, Dwyer GB, Fitts TC, Lewis BT. Resources for the health fitness specialist. (1st Edition). Philadelphia, PA: Lippincott, Williams, and Wilkins, 2014. 9. Mackenzie NG. Walk Off the Weight: Speed-Interval Walking Workout. (Online). http:// www.fitnessmagazine.com/workout/cardio/walking/walking-for-weight-loss-plan. 2015. 10. Manini TM, Everhart JE, Patel KV, Schoeller, DA, Colbert LH, Visser M, Harris TB. Daily activity energy expenditure and mortality among older adults. JAMA. 2006;296 (2):171-179. 11. Melanson Jr EL, Freedson PS. Validity of the computer science and applications, Inc. (CSA) activity monitor. Med Sci Sports Exerc. 1995;27(6):934-940. 12. Moreau KL, Degarmo R, Langley J, McMahon C, Howley ET, Bassett DRJ, Thompson DL. Increasing daily walking lowers blood pressure in postmenopausal women. Med Sci Sports Exerc. 2001;33(11):1825-1831. 13. Studenski S, Perera S, Patel K, Rosano C, Faulkner K, Inzitari M, Guralnik J. Gait speed and survival in older adults. JAMA. 2001;305(1):50-58. 14. Thompson WR. Worldwide survey of fitness trends for 2016: 10th Anniversary Edition. ACSM's Health Fit J. 2015;19(6):9-18. 15. Tudor-Locke CE, Myers AM. Challenges and opportunities for measuring physical activity in sedentary adults. Sports Med. 2001;31(2):91-100. 16. Tudor-Locke CE, Bassett DR. How many steps/day are enough? Preliminary pedometer indices for public health. Sports Med. 2004;34(1):1-8. 140 Disclaimer The opinions expressed in JEPonline are those of the authors and are not attributable to JEPonline, the editorial staff or the ASEP organization.