Additel 780 Pressure Controller Pressure ranges from vacuum to 200 bar External intelligent sensors Precision accuracy of 0.005% +0.005% of full scale Standalone solution up to 2000 bar, no gas bottle required when used with the electric pump and 3K (2000 bar) gas booster Standalone solution up to 700 bar, no gas bottle required when used with the electric pump Standard model accuracy of 0.02% of full scalee External pressure modules too 200 bar WiFi enabled communicationss Fully temperature compensated accuracy from 0 C to 50 C HART communication and Profibus PA Large 7 color touch screen display Control stability of 0. 003% Built-in barometer Overvie ew For years, we have provided the most durable, accurate, quality pressure calibration products for field applications. The Additel 780 series controller incorporates the t same durability, accuracy and quality into a new bench top controller packed with features and functionality that is remarkably easy to use. The Additel 780 series offers two base ranges: to 70 bar and 2000 bar. The base range establishes the maximum controlling range of the controller. Each configuration includes a control sensor which is preselected to the sensorr range best suited for your application. External and internal sensors can be used which allows ann expandedd range and accuracy capability in the future. By DAkkS according to DIN EN ISO / IEC 17025: 20055 accredited laboratory. The accreditation is valid for the certificate systemm D-K-15055-01-00 listed accreditation scope. 15.08.2015 GmbH Pressure (DAkkS) Temperature Flow Humidity Electric Quantities Masses and Balance 1 / 8 Phone.: + 49 (0) 6181 / 42 30 9 0 service@ @.de http://www..de
Modula ar design Each unit comes with one intelligent pressure module configured to the many range offerings provided. Standard accuracy sensors (ADT160A-CPXXX) are silicone pressure sensors with a 1 year accuracy of 0.02%. The precision quartz sensors improve the 1 year accuracy specification to 0.005% +0.005%. Each sensor has been specially aged, tested and screened before assembly. After assembly each sensor is temperature compensated over the range of 0 C to 50 C. The Additel 780 series can be equipped with one internal pressure sensor and one external pressuree sensor. The design of this unit provides an interchangeability of both the internal and external sensors with other intelligen pressure modules. Standal lone solution The typical pressure controller will require a nitrogen bottle for the gas supply which makes it difficult to move the t controller around without have to move or connect another bottle. The Additel 780 series is unique in that withh the optional electric pump, you can generate pressures to 70 bar without the need n of a gas bottle. Add the booster to the configuration and 200 bar is achievable with the Additel780 controller series. Process s functionality The 780 series pressure controller is considered to handle a veryy wide rangee of applications which may normally requiree a pressure calibrator. Built-in capability includess current and voltage measureme ent capability, 24 voltt loop power, HART and Profibus PA communication, switch measureme ent capability and much more. Measur rement specifications Specificati on Pressure range Control stability Precision (includes 1 year stability) Stability/ 1 year Media Over-range indication Resolution Pressure type Warm up type Typical pressure settling time (within 0.003% ) Measurement units Minimum control pressure [3] -0,95 bis 70 bar -0,95 bis 200 bar [1] (Vakuum bis 1000 psi) (Vakuum bis 3000 psi) 0.003% (stability based on % of control sensor range See pressure table range 0,01% standard accuracyy sensors precision accuracyy sensors Clean gas 103% to 120% (based( on sensor) 4,5,6 or 7 digits (user selectable [2] Gauge, absolute 15 minutes m 20 seconds (10% pressure change assuming 50ccm test volume) Pa, hpa, kpa, MPa, bar, mbar, psi, mmhg@0 C,cmHg@0 C, mhg@0 C, inhg@0 C,inH 2 O@4 C, mmh 2 O@4 C, cmh 2 O@4 C, mh 2 O@ @4 C, mmh 2 O@20 C, cmh 2 O@20 C, mh 2 O@20 C, kg/m 2, kg/cm 2, mtorr, torr, atm, lb/ft 2, tsi, user selectable 0,007 mbar (0,0001 psi) 0,07 mbar (0,001 psi) GmbH 2 / 8 service@ @.de http://www..de
[1] booster or HP gas supply requited to reach 200 bar. Booster ordered separately. [2] 7 digit resolution for precision mode [3] Dependent on pressure module [4] Barometer sensor: (0~ 120) kpa, 0.05% (0.01% is optional) Electrical measurement specifications Specification Range Resolution Accuracy ±0,01% -3 30 V 0,1 mv + 1,5 mv Volts DC ±0;01% -30 300 mv 1 µv + 15 μv ±0,01% Current DC -3 30 ma 0,1 µa + 1,5 μa Switch test If the switch has detected voltage, the range is from 3-24 V DC 24V output Physical specifications Specification Power Pressure ports & 100V - 250V, 50/60 Hz G1/8 F Storage temperature -20 C to 70 C Operating environment Display Weight Dimensions (DWH) Mounting Schock Vibration Other specifications 0-95% RH non-condensing 24V ± 0,24V, max 30 ma 7 inch (17.8 cm) color, touch screen display 15 kg 419 x 440 x 132 mm Standard desktop, optional rack mount 4G 1G 10Hz~500Hz WiFi specifications Analog output Communications Stability indicator Typical slew rate Operating modes Display modes Localization Conformity Calibration certification Warranty 802.11 b, g, and n User selectable, 0-10 V, 0-5 V, 0-20 ma, 4-20 ma RS232,USB,LAN,WIFI User selectable 20 seconds Control, measure, vent Controller shows pressure indication and control Calibrator shows pressure indication, control and electrical measurement English, German, Spanish, French, Italian, Portuguese, Russian, Chinese (traditional and simplified), Japanese CE NIST traceable certificate of calibration with data included DAkkS Certificate (optinal) 1 year This document subject to change without notice 3 / 8 GmbH service@.de Fax: + 49 (0) 6181 / 42 http://www..de
Electric c pump and booster Additel 780-1K-EPUMP electric pump Generates from vaccum up to 70 bar Built-in filter and liquid trap 70 bar electric pump specifications Pressure range Weight Dimension ns (WxHxD) Power Media Outlet port Storage temperature Operating environment Mounting Control operation Typical max. pressure time -0,95 to75 bar 31,6 kg 440 x 235 x 550 mm 10 250V Air G1/8F -20 C to 70 C 0 95% RH, non-condensing Standard desktop, optional 19 rack mount 2 LED displays with pressure limit settings Approx. 2 min with ADT780 controller Additel 780-3K-BST Booster 200 bar gas booster specifications Min inlet pressure Out pressure range Inlet flow rate Size (WxHxD) Weight Power Supply media 20 bar 250 bar 500ml/min 451 x 185 x 607 mm 33,6 kg 10 250 V Nitrogen or clean gas GmbH 4 / 8 service@ @.de http://www..de
Standar rd accessoriess ADT127-X external manifold Manifold connection cable Power adapter 90222 test leads 2 sets (4 pieces) 9020 short circuit cable 1 set (2 pieces) 9060 pressure module connection cable Adapter set (adapters to fit the ADT78X port to male fittings) Manual NIST traceable certiificate O-rings 20xx ( DAkkS-Certificate optional) GmbH 5 / 8 service@ @.de http://www..de
Optiona ales Zubehör ADT160A Pressure module (see module information) ADT121-X External pneumatic pressure manifold,, 200 bar, four hand- tight quick connectors -BST 200 bar gas booster -EPUMP 70 bar electrical pump ADT780-VACPUMP Vacuum pump 9050 RS2322 to USB adapter Liquid trap Liquid trap 9907-780 Shipment case for the ADT780 controller K- Additel/ Pcal Acal Werkbank Einbau Satz ADT100-780-Kit DAkkS-Calibration Additel/ Pcal calibration software Automatedd calibration software, task and asset management Rack mount kit Adapter set, X pcs, g1/8 M to various connections DAkkS-certificate GmbH 6 / 8 service@ @.de http://www..de
ADT160 0A intelligent digital pressuree modules Gauge pressure Differential pressure Specificati ons Model Pressuree range psia bar a Media Accuracy Pressure rating Over Burst pressure Suggested controller compatibility Internal/ external use AP45Q 45 2,0 Precision quartz sensors + 1,2xx AP100Q s 100 7,0 + 1,2xx AP400Q 400 28 + 1,2xx AP500Q 500 35 + 1,0x AP1KQ 1000 70 + 1, AP2KQ 2000 140 + 1, AP3KQ 3000 200 + 1, GmbH 7 / 8 service@ @.de http://www..de
Pressure Pressure rating range Model Media Accuracy Over psig bar.g Burst pressure Standard Druck Sensoren 0,02% CP10 ±10 ±0,7 1,2x CP15 ±15 ±1,0 0,02% 1,2x CP30 CP50 CP100 CP300 CP500 CP600 CP1K CP2K CP3K CP5K CP10K 30 50 100 300 500 600 1000 2000 3000 5000 10000 2.0 3,5 7,0 20 35 40 70 140 200 300 700 [1] Contact for other range options 0,02% 1,2x 0,02% 1,2x, liquid 0,02% 1,2x Suggested controller compatibility Nur ADT780-1K Internal/ external use This document subject to change without notice 8 / 8 GmbH service@.de Fax: + 49 (0) 6181 / 42 http://www..de, liquid 0,02% 1,2x, liquid 0,02% 1,2x, liquid 0,02% 1,2x, liquid 0,02% 1,2x, liquid 0,02% 1,2x, liquid 0,02% 1,2x, liquid 0,02% 1,2x n/a External, liquid 0,02% 2x 1,2x n/a External ** Low pressure sensors (ADT160A-XX-DPX) available for low pressure and differential pressure measurement. Also available for low pressure control (gauge mode ). Ranges from ±1 inh 2 O (2.5 mbar) to 300 inh 2 O (700 mbar). Sensor specifications Standard accuracy Precision accuracy CPXXX AP3KQ AP1KQ AP100Q Temperature compensation -10 C to 50 C 0 C to 50 C Operating temperature -10 C to 50 C 0 C to 50 C Storage temperature -20 C to 70 C -20 C to 70 C Relative humidity 95% RH 95% RH Pressure connections (for external use ) 1/4NPT, 1/4BSP, M20x15 1/4NPT, 1/4BSP, M20x15 Enclosure (for external SS enclosure SS enclosure use ) Dimensions (Dia x H) 33 mm x 123 mm 44 mm x 220mm 60 mm x 190 mm Weight 0,4 kg 0,8 kg 1,2 kg [1] Internal sensors used to go inside the ADT780 nee d to have a M20 connection and connection kit.