Simulation of Experiment on Aerosol Behaviour at Severe Accident Conditions in the LACE Experimental Facility with the ASTEC CPA Code

Similar documents
Loss of Normal Feedwater Analysis by RELAP5/MOD3.3 in Support to Human Reliability Analysis

V.H. Sanchez Espinoza and I. Gómez-García-Toraño

EXPERIMENTAL STUDY OF HEAT, MASS AND MOMENTUM TRANSFERS IN A SPRAY IN THE TOSQAN FACILITY

CFD SIMULATIONS OF GAS DISPERSION IN VENTILATED ROOMS

Visual Observation of Nucleate Boiling and Sliding Phenomena of Boiling Bubbles on a Horizontal Tube Heater

EXPERIMENTAL STUDY OF HEAT, MASS AND MOMENTUM TRANSFERS IN A SPRAY IN THE TOSQAN FACILITY

SENSITIVITY ANALYSIS OF THE FIRST CIRCUIT OF COLD CHANNEL PIPELINE RUPTURE SIZE FOR WWER 440/270 REACTOR

Experimental Verification of Integrated Pressure Suppression Systems in Fusion Reactors at In-Vessel Loss-of -Coolant Events

Chapter 13 Gases, Vapors, Liquids, and Solids

Evaluation of the fraction of Unit-3 vent gas that flowed into Unit-4 reactor building

HYDROGEN RISK ANALYSIS FOR A GENERIC NUCLEAR CONTAINMENT VENTILATION SYSTEM

Verification and validation of computer codes Exercise

Figure Vapor-liquid equilibrium for a binary mixture. The dashed lines show the equilibrium compositions.

APPLICATION OF COCOSYS CODE FOR INVESTIGATION OF GAS MIXING IN MISTRA TEST FACILITY

1 SE/P-02. Experimental and Analytical Studies on Thermal-Hydraulic Performance of a Vacuum Vessel Pressure Suppression System in ITER

13.1!"#$#%"&'%()$*+%,+-.$+/*$#

I.CHEM.E. SYMPOSIUM SERIES NO. 97 BUOYANCY-DRIVEN NATURAL VENTILATION OP ENCLOSED SPACES

PURE SUBSTANCE. Nitrogen and gaseous air are pure substances.

EXPERIMENTAL SUPPORT OF THE BLEED AND FEED ACCIDENT MANAGEMENT MEASURES FOR VVER-440/213 TYPE REACTORS

INTERACTION BETWEEN WIND-DRIVEN AND BUOYANCY-DRIVEN NATURAL VENTILATION Bo Wang, Foster and Partners, London, UK

Comparison of MARS-KS to SPACE for counter current flow limitation model

Experimental Characterization and Modeling of Helium Dispersion in a ¼-Scale Two-Car Residential Garage

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

Steam penetration in steam sterilization processes

STANDARDS FOR COMPRESSED GAS TESTING

IAEA Training in Level 2 PSA MODULE 8: Coupling Source Terms to Probabilistic Event Analysis (CET end-state binning)

HTR Systems and Components

LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary

EUROPEAN COMMISSION 5th EURATOM FRAMEWORK PROGRAMME KEY ACTION: NUCLEAR FISSION

Nitrogen subtraction on reported CO 2 emission using ultrasonic flare gas meter

Fall 2004 Homework Problem Set 9 Due Wednesday, November 24, at start of class

ICONE ASSESSMENT OF THE TRACE REACTOR ANALYSIS CODE AGAINST SELECTED PANDA TRANSIENT DATA

CONSIDERATION OF DENSITY VARIATIONS IN THE DESIGN OF A VENTILATION SYSTEM FOR ROAD TUNNELS

Enhancing NPP Safety through an Effective Dependability Management

Effects of Delayed RCP Trip during SBLOCA in PWR

This test shall be carried out on all vehicles equipped with open type traction batteries.

SUMMARY OF THE EXPERIMENTAL STUDIES OF COLD HELIUM PROPAGATION ALONG A SCALE MODEL OF THE LHC TUNNEL

The ongoing experimental programs at IRSN on

Generating Calibration Gas Standards

Comparative Study of Oxygen Permeation Through Polymers and Gas Barrier Films

MISTRA Facility for Containment Lumped Parameter and CFD Codes Validation: Example of the International Standard Problem ISP47

AIRFLOW GENERATION IN A TUNNEL USING A SACCARDO VENTILATION SYSTEM AGAINST THE BUOYANCY EFFECT PRODUCED BY A FIRE

A. M. Dalavi, Mahesh Jadhav, Yasin Shaikh, Avinash Patil (Department of Mechanical Engineering, Symbiosis Institute of Technology, India)

DRINKING WATER - LAB EXPERIMENTS LAB EXPERIMENTS. Nanofiltration

Chapter 4, Problem 30.

Chapter 14 Fluids Mass Density Pressure Pressure in a Static Fluid Pascal's Principle Archimedes' Principle

Ch. 11 Mass transfer principles

Kinetic-Molecular Theory

ASSIGNMENT 2 CHE 3473

ASTEC application to HTRs

SIMULATION OF CONTAINMENT HYDROGEN CONTROL SYSTEM AT IGNALINA NPP

International Agreement Report

Control of Nuclear Gloveboxes and Enclosures Using the No- Moving-Part Vortex Amplifier (VXA)

ASSIGNMENT 2 CHE 3473

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER F: CONTAINMENT AND SAFEGUARD SYSTEMS 7. CONTAINMENT HEAT REMOVAL SYSTEM (EVU [CHRS])

OIL AND GAS INDUSTRY

MODELING STUDY OF THE BEHAVIOR OF LIQUID FIRE SUPPRESSION AGENTS IN A SIMULATED ENGINE NACELLE

CRYSTALLIZATION FOULING IN PACKED COLUMNS

The Split of Two-Phase-Flow at Horizontal Side-T-junctions in Unbalanced Pipe Systems for Clean Extinguishing Agents

CONTENTS OF THE PCSR CHAPTER 1 - INTRODUCTION AND GENERAL DESCRIPTION

Introductory Lab: Vacuum Methods

Module 03 Accident modeling, risk assessment and management Lecture 04 Explosions

SIMULATION OF ENVIRONMENTAL FLIGHT CONDITIONS

Self-operated Pressure Regulators for special applications

VISIMIX TURBULENT. HEAT TRANSFER PROCESS IN A SEMIBATCH REACTOR

Mass Split of Two-Phase-Flow

1.2 Example 1: A simple hydraulic system

Lecture 8 questions and answers The Biological Pump

Example: 25 C = ( ) K = 298 K. Pressure Symbol: p Units: force per area 1Pa (Pascal) = 1 N/m 2

1. A pure substance has a specific volume of 0.08 L/mol at a pressure of 3 atm and 298 K. The substance is most likely:

ADVANCES in NATURAL and APPLIED SCIENCES

Reflux Condensation with Various Non-Condensable Gases

End of Chapter Exercises

SAFETY DEMONSTRATION TESTS ON HTR-10

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

Procedure 1: Volume vs. Pressure 1.) Using the lap tops, go to the Physics Education Technology from the University of Colorado at:

DETAILS OF THE ACCIDENT PROGRESSION IN 1F1

Irrigation &Hydraulics Department lb / ft to kg/lit.

Uncertainty in the analysis of the risk of BLEVE Fireball in process plants and in transportation

CFD Flow Analysis of a Refrigerant inside Adiabatic Capillary Tube

PERFORMANCE OF HYDROGEN MITIGATION SYSTEMS FOR A SCALED ACCIDENT SCENARIO: OVERVIEW OF ERCOSAM PROJECT EXPERIMENTAL RESULTS FOR THE PANDA FACILITY

ON TRANSIENTS IN PUMA

GAS MIXTURES. Department of Mechanical Engineering

Gas Vapor Injection on Refrigerant Cycle Using Piston Technology

Injector Dynamics Assumptions and their Impact on Predicting Cavitation and Performance

ACCUMULATION OF HYDROGEN RELEASED INTO A VENTED ENCLOSURE - EXPERIMENTAL RESULTS

SHUTDOWN SYSTEMS: SDS1 AND SDS2

CFD development for wind energy aerodynamics

Effect of airflow direction on human perception of draught

First Experimental Data of the Cryogenic Safety Test Facility PICARD

Paper 2.2. Operation of Ultrasonic Flow Meters at Conditions Different Than Their Calibration

ANALYSIS OF HEAT TRANSFER THROUGH EXTERNAL FINS USING CFD TOOL

Rotary air valves used for material feed and explosion protection are required to meet the criteria of NFPA 69 (2014)

H 2 O Bubble Chamber Superheated Active Target System. Safety and Systems Overview B. DiGiovine

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Numerical Simulation of Instability of Geothermal Production Well

23 RD INTERNATIONAL SYMPOSIUM ON BALLISTICS TARRAGONA, SPAIN APRIL 2007

AP TOPIC 6: Gases. Revised August General properties and kinetic theory

Each gas sample has the same A) density B) mass C) number of molecules D) number of atoms

My Website:

Transcription:

Simulation of on Aerosol Behaviour at Severe Accident Conditions in the LACE al Facility with the CPA Code Ivo Kljenak, Borut Mavko Jožef Stefan Institute Jamova 39, SI-1000 Ljubljana, Slovenia Ivo.Kljenak@ijs.si, Borut.Mavko@ijs.si ABSTRACT The experiment LACE LA4 on thermal-hydraulics and aerosol behavior in a nuclear power plant containment, which was performed in the LACE experimental facility, was simulated with the CPA module of the severe accident computer code V1.2. The specific purpose of the work was to assess the capability of the module (code) to simulate thermal-hydraulic conditions and aerosol behavior in the containment of a light-water-reactor nuclear power plant at severe accident conditions. The test was simulated with boundary conditions, described in the experiment report. Results of thermal-hydraulic conditions in the test vessel, as well as dry aerosol concentrations in the test vessel atmosphere, are compared to experimental results and analyzed. 1 INTRODUCTION During an unmitigated severe light-water-reactor (LWR) accident with core meltdown, radioactive fission and activation products would be released into the containment as gas, vapor or, to a great extent, adsorbed on aerosols. Since the knowledge of time-dependent distributions of fission products and aerosols is very important to mitigate accidents, relevant prediction capabilities are of great importance. s with aerosols are thus being used to assess the capabilities of severe accident codes to simulate aerosol behavior. s on aerosol behavior have been performed in 1986 in the LACE (LWR Aerosol Containment ) experimental facility, at Westinghouse Hanford Company (USA) [1]. The objectives of the LACE program were to investigate experimentally the inherent aerosol retention behavior for postulated, high-consequence accident situations, and to provide a data base for validating containment aerosol and related thermal-hydraulic computer codes. The LACE facility is a large cylindrical vessel, in which gases and aerosols are being injected during experiments. During the experiment considered in the present work, CsOH aerosols (water soluble) were injected first. Then, a mixture of CsOH and MnO (nonsoluble) aerosols was injected, followed by injection of sole MnO aerosols. Steam and nitrogen were also injected, as aerosol carrier gases as well as to pressurize the vessel. 410.1

410.2 The severe accident code is being developed jointly by the Institut de Radioprotection et de Sureté Nucléaire IRSN (France) and by the Gesellschaft für Anlagen und Reaktorsicherheit GRS (Germany) [2]. The assessment of physical models, implemented in the code, is being carried out within the Severe Accident Research Network of Excellence (SARNET), which is part of the 6th EU Framework Program. In the present work, the experiment LACE LA4 was simulated with the CPA (Containment Part of ) lumped-parameter module of the V1.2 code (the module is referred in the present paper as the CPA code ) [3,4]. The first 850 min of the above-mentionned test (that is, until the vessel is finally opened to the atmosphere and left to cool down) were simulated. The calculated thermal-hydraulic conditions (pressure, atmosphere temperature, steam partial pressure and mass fraction), as well as CsOH and MnO aerosol concentrations in the vessel atmosphere are compared to experimental results. 2 EXPERIMENT 2.1 al Facility The key piece of the LACE Containment System Test Facility is the containment vessel (Figure 1). It is a vertical cylindrical steel vessel with an inner free volume of 852 m 3. The overall height of the vessel is 20.3 m, and the inner diameter of the cylindrical part is 7.62 m. The walls are not heated (their temperature is not controlled) and they are insulated on the outside with a 25-mm thick layer of insulation. The containment vessel is fabricated of carbon steel plates ranging in thickness from 16.4 mm to 19.1 mm. The total mass of the upper head, cylindrical wall and lower head is 24937 kg, whereas the total mass of the internal structures is 14020 kg. Many penetrations exist for electrical, instrumentation, water, steam, ventilation and sampling lines. The vessel can be vented through a leak path which vents to the atmosphere. Additional details about the experimental facility are provided in the LACE LA4 final report [1]. 2.2 al Procedure The test LA4 started at time -50 min with injection of gases. Aerosols were injected between times 0 min and 80.2 min. After that, the vessel was gradually vented and cooled down. The venting simulated a delayed containment failure following a severe accident and was a special feature of the test LA4. Two aerosol materials were generated separately during different, overlapping periods. CsOH aerosol (soluble) was generated by reaction of Cs vapor with steam. Elemental Cs was heated in a pressurized supply vessel and discharged into a heated vaporizer coil. The vaporized Cs and a low flow rate of nitrogen sweep gas flowed through a heated line to a reaction chamber containing superheated steam and nitrogen. MnO aerosol (non-soluble) was generated by vaporizing Mn powder in plasma torches and discharging the Mn vapor into a reaction chamber which contained a superheated steam and nitrogen atmosphere. The species were mixed in an intermediate vessel to provide some time for coagglomeration and fallout of oversized particles to occur and then injected into the containment vessel.

410.3 Figure 1. Schematic view of the LACE experimental facility [1]. Specifically, the test consisted of the following phases: 1. Heatup: -50 0 min nitrogen injection through aerosol delivery line, 2. Injection of CsOH aerosols: 0 30.5 min aerosol carrier gas injection (steam, N 2, He, Ar), aerosol injection, 3. Injection of CsOH and MnO aerosols: 30.5 50.5 min aerosol carrier gas injection (steam, N 2, He, Ar), aerosol injection, 4. Injection of MnO aerosols: 50.5 80.2 min aerosol carrier gas injection (steam, N 2, He, Ar), aerosol injection, 5. Steady state: 80.2 280 min nitrogen injection through aerosol delivery line, 6. Venting: 280 600 min (vent flow stopped at 440 min)

410.4 nitrogen injection through aerosol delivery line, 7. Cooldown: 600 5700 min nitrogen injection through aerosol delivery line, nitrogen purge to instruments, vent valve opened at 800 min. 3 INPUT MODEL 3.1 Test Vessel The vessel was modeled as a single control volume ( zone ), whereas the environment was modeled as another zone. The main purpose of the development of the code is to use it for simulations of severe accidents in actual nuclear power plants. As CPA is a lumped-parameter code, a multi-compartment containment would in principle be modeled in such a way, that each compartment would be modeled as a single zone. As the volume of the LACE experimental vessel is of the same order of magnitude as the volume of an individual compartment in a multi-compartment containment, the modeling of the LACE vessel as a single zone is adequate to assess the code capability to model accidents in actual plants. The vessel walls were modeled as specified in the LACE LA4 final report (see Table 1). They consisted of the top head, cylinder, and bottom head. In addition, internal steel structures were modeled as vertical and horizontal slabs. The surfaces and masses of internal structures correspond to the specifications in the LACE LA4 final report. The prescribed maximum thickness of the water film on walls and structures was 0.5 mm. Table 1. Modeling of vessel walls Area Steel thickness Insulation thickness m 2 m m Top Head 63.0 0.0193 0.025 Cylinder 394.0 0.0169 0.025 Bottom Head 63.0 0.0193 0.025 3.2 Aerosol Modelling Aerosol parameters were prescribed in the input model as described in the LACE LA4 final report, or by prescribing commonly used generic options. The prescribed aerosol density was 4560 kg/m 3, which is the median value of CsOH and MnO aerosol densities. Steam condensation on aerosols, deposition by diffusiophoresis and deposition by thermophoresis were prescribed. The aerosol injection mass flow rates during the experiment were calculated in the report by combining mass balances and measurements from filter samplings. These injection rates were included in the input model. Details are provided in refs. [5] and [6]. The Kelvin effect ought to be considered for soluble CsOH aerosols and not considered for non-soluble MnO aerosols. However, the CPA code does not allow separate modeling of the Kelvin effect for separate aerosol components. Besides, if the Kelvin effect was modeled, the simulation stopped due to numerical problems. Thus, the test was simulated

410.5 without modeling the Kelvin effect. The aerosol size range (diameters from 5 10-8 m to 1 10-4 m) was divided into 20 sections. Log-normal size distributions were prescribed. The mass median radii and the geometric standard deviations are shown in Table 2. Table 2. Aerosol size distribution parameters Time interval Mass median radius CsOH Geom. stand. deviat. Mass median radius MnO Geom. stand. deviat. s μm μm 0 1830 0.3478 1.81 1831 3030 0.5746 1.80 0.5185 1.70 3031 4812 0.3861 2.56 3.3 Initial and Boundary Conditions The test was simulated from time -3000 s (-50 min) to time 48000 s (800 min). The initial conditions were prescribed as specified in the LACE LA4 final report. The pressure was 1.07 bar, the temperature of the atmosphere and of the walls was 42.5 C, the mass of water in the sump was 950.0 kg, the temperature of the water in the sump was 41.9 C, and the volumetric steam fraction in the vessel atmosphere was 0.0730. The venting of the vessel during some phases of the experiment was taken into account as well. The removal of gases due to venting and sampling was prescribed according to the reported measurements in the final report. However, a correction had to be introduced. Namely, air was modeled as a mixture of oxygen and nitrogen. If the venting was modeled according to the data specified in the report, than the mass of oxygen in the vessel would drop below zero. To remedy to this situation, additional nitrogen was removed instead of oxygen from a time when the mass of oxygen attained a value close to zero. The heating due to the internal lightning and the cooling due to the cooling water to the velocity measuring turbines were modeled as heat sources and sinks, respectively. The experimental measurements indicate significant flow velocities in the containment atmosphere (up to 1.5 m/s). As this flow was not modeled due to a lumped-parameter description and single-zone modeling of the test vessel, this could be the cause for some discrepancies between the experimental and simulation results. Namely, the atmosphere flow in the facility probably significantly influenced atmosphere mixing, which in turn could influence steam condensation on structures as well as aerosol deposition on vessel walls, internal structures and in the sump. According to the LACE LA4 final report, the venting accounted for a loss of about 0.2% of the injected aerosol mass into the containment vessel. The removal of aerosols by venting was not modeled. 4 RESULTS AND DISCUSSION al and simulation results are shown on Figures 2 to 8. Figure 2 shows the experimental and simulated pressure in the test vessel. The uncertainty of the experimental measurements is ± 2% [1]. The general trend was very well simulated. The calculated

410.6 pressure remained somewhat too high after the stopping of the vent flow at 440 min. Figure 3 shows the experimental and simulated atmosphere temperature in the test vessel. The uncertainty of the experimental measurements is ± 3 ºC [1]. The agreement between results is good. The calculated temperature after the stopping of the vent flow at 440 min was somewhat too high as well. Figure 4 shows the experimental and simulated steam mass fraction in the test vessel. The uncertainty of the experimental measurements is ± 10%. The different symbols correspond to different measuring locations in the test vessel. The general agreement between results is good. The differences between experimental measurements show that, during the experiment, the atmosphere was not entirely homogeneous. Figure 5 shows the experimental and simulated steam pressure in the test vessel. The experimental partial pressure of steam was computed by multiplying the volumetric steam fraction by the total pressure. The different symbols also correspond to different measuring locations in the test vessel. A good agreement may be observed. The calculated steam pressure remained somewhat too high after the stopping of the vent flow at 440 min. This is related to the similar overprediction of the total pressure. Figure 6 shows the experimental and simulated mass of water in the vessel sump. The overprediction between 0 s and 20000 s seems to be an indication of the overprediction of steam condensation in this period. The discrepancy in the final phase of the simulation is probably due to the leaking from the cooling lines, reported in the LACE LA4 final report. Figures 7 and 8 show the experimental and simulated dry aerosol mass concentration of soluble and non-soluble aerosols, respectively, in the test vessel atmosphere. The uncertainty of the experimental measurements is ± 25% [1]. The concentration of non-soluble aerosols agrees very well with the experimental results. The maximum and final value of the concentration of soluble aerosols also agree well with the experimental results. However, the simulated pattern of concentration decrease was different from the experimental one. A possible explanation for this discrepancy is the non-adequate simulation of the atmosphere saturation. Namely, according to the LACE LA4 final report, the atmosphere in the test vessel was saturated or close to saturation during the entire experiment. However, as shown on Figure 9, the simulated saturation during the first 10000 s was well below 100%, which perhaps prevented a more intense condensation of steam on soluble aerosol particles. Another possible explanation for the discrepancy is the lack of modeling of the Kelvin effect. 3.0x10 5 120 2.5x10 5 100 Pressure [Pa] 2.0x10 5 1.5x10 5 1.0x10 5 5.0x10 4 0.0 Temperature [ o C] 80 60 40 20 Figure 2. al and simulated pressure in test vessel. Figure 3. al and simulated atmosphere temperature in test vessel.

410.7 0.6 Steam Mass Fraction [-] 0.5 0.4 0.3 0.2 0.1 0.0 Pressure [Pa] 1.5x10 5 1.0x10 5 5.0x10 4 0.0 2.0x10 5 Figure 4. al and simulated steam mass fraction in test vessel. Figure 5. al and simulated steam pressure in test vessel. 4000 1x10-1 Mass [kg] 3500 3000 2500 2000 1500 1000 CsOH Aerosol Conc. [kg/m 3 ] 1x10-3 1x10-5 1x10-7 1x10-9 10-11 Figure 6. al and simulated mass of water in vessel sump. Figure 7. al and simulated dry aerosol mass concentration of soluble aerosols in vessel atm. 1x10-1 120 MnO Aerosol Conc. [kg/m 3 ] 1x10-3 1x10-5 1x10-7 1x10-9 Saturation [%] 100 80 60 10-11 40 Figure 8. al and simulated dry aerosol mass concent. of non-soluble aerosols in vessel atm. Figure 9. Simulated saturation of test vessel atmosphere.

410.8 5 CONCLUSIONS The first 850 minutes of the experiment LACE LA4 on thermal-hydraulics and aerosol behavior in a light-water-reactor nuclear power plant containment atmosphere at accident conditions, which was performed in the LACE facility, were simulated with the CPA V1.2 code. The thermal-hydraulic conditions were mostly well simulated. The calculated pressure and temperature were a little too high after the stopping of the vent flow from the containment vessel. The maximum values and values at the end of the simulation of the dry aerosol concentrations in the vessel atmosphere also agreed well with the measured values. However, the simulated trend of the decrease of the soluble dry aerosol concentration was different from the trend that was observed in the experiment. This could be due to an underprediction of the atmosphere saturation during aerosol injection, or to the lack of modeling of the Kelvin effect. Nevertheless, the agreement between experimental and calculated results supports the applicability of the CPA code to simulate thermal-hydraulic and aerosol phenomena in an LWR NPP containment at accident conditions. ACKNOWLEDGMENTS The research presented in the present work was performed within the research program Reactor engineering (contract no. 3311-04-8226614) financed by the Ministry of Higher Education, Science and Technology of the Republic of Slovenia. The Jozef Stefan Institute is a member of the Severe Accident Research Network of Excellence (SARNET) within the 6 th EU Framework Programme. The benefit from European Commission RTD Programme for research is acknowledged. REFERENCES [1] J.D. McCormack, R.K. Hilliard, J.M. Salgado, Final Report of al Results of LACE Test LA4 Late Containment Failure with Overlapping Aerosol Injection Periods, Westinghouse (USA), 1987. [2] J.P. Van Dorsselaere et al., V1.1 Overview, Rev.0, Report -V1/DOC/04-10, IRSN (France) and GRS (Germany), 2004. [3] W. Klein-Hessling, B. Schwinges, V0 CPA Module, Program Reference Manual, Rev.0, Report -V0/DOC/01-34, IRSN (France) and GRS (Germany), 1998. [4] J. Bestele, W. Klein-Hessling, V0 CPA Module, Containment Thermalhydraulics and Aerosol and Fission Product Behaviour, User Guidelines, Rev. 0, Report - V0/DOC/00-14, IRSN (France) and GRS (Germany), 2000. [5] I. Kljenak, B. Mavko, Simulation of LACE LA4 on Aerosol Behavior in a Nuclear Power Plant Containment with the CPA V1.2 Code, Report IJS-DP- 9484, Rev. 0, Jozef Stefan Institute (Slovenia), 2006. [6] I. Kljenak, B.Mavko, Simulation of LACE LA4 on Aerosol Behavior in a NPP Containment at Severe Accident Conditions with the CPA Code, Proc. 15th Int. Conf. on Nuclear Engineering, Nagoya, Japan, April 22-26, 2007.