Operating manual. TA 197 Oxi. Dissolved Oxygen Depth Armature

Similar documents
IQ SENSOR NET TriOxmatic 700 IQ (SW)

Operating manual. TriOxmatic 702 IQ. IQ SENSOR NET D.O. sensor

STERILIZABLE DISSOLVED OXYGEN SENSORS

COM280. Technical Information. Oxygen measurement Battery-driven pocket meter for dissolved oxygen measurement

Handheld meter Oxi 3150i

Oxymax W COS41. Technical Information. Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications

Dissolved Oxygen/Temp Waterproof Tester

INSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter

Operating manual. Oxi 3205 O mg/l C. [Sal] Dissolved oxygen (D.O.) meter

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

12mm Dissolved Oxygen Sensor Care and Use Instructions

Instruction Manual HI Portable Waterproof Dissolved Oxygen Meter.

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

SensoDirect Oxi200 Dissolved Oxygen Meter Operating instructions

Operating manual. AmmoLyt 700 IQ. IQ SENSOR NET ammonium sensor

CCS240 and CCS241. Technical Information. Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly

Oxymax H COS21. Technical Information. Sensor with long-term stability for frequent sterilization and autoclaving

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

Dextens Thermo Conductivity Sensors. Type 52101, 54101, 55101

Oxymax W COS51D. Technical Information. Digital sensor for measuring dissolved oxygen Membrane-covered amperometric sensor

Heavy Duty Dissolved Oxygen Meter

DISSOLVED OXYGEN SENSOR BT34i

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Evaluation copy. Interdependence of Plants and Animals. computer OBJECTIVES MATERIALS

LogIT Dissolved Oxygen Probe

Instruction Manual HI Portable Dissolved Oxygen Meter. DO meter HI 8043 STB C OFF O 2 ZERO SLOPE C. ins rum n s

OxyProbe II Instruction Manual

Columbus Instruments

AQUARIUS. Operating Instructions for the. Type 70 Electrolytic Gas Soldering / Welding Unit. Table of Contents

Please read these instructions carefully before use! Please consider the safety instructions! Please keep for future reference!

O 2 DO Meters. Oxygen Meters. Handheld oxygen meters Portable oxygen meters Laboratory oxygen meters. Literature

SS32L Dissolved O 2 Probe

T02.0.3X.6C-06 Page 1 of 6. Operating Manual for Dissolved Oxygen-Measuring transducer OXY 3610 MP

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

Instruction Manual Contact Pressure Vacuum Gauge

Oxymax H COS21D. Technical Information

STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE

BI-680 Online Dissolved Oxygen Controller Instruction Manual

FPD20 Series. Gear wheel flow sensor

The Oxygen Sensor can be connected to all types of einstein Tablets, einstein LabMate, and einstein LabMate +.

NEULOG OXYGEN LOGGER SENSOR GUIDE

OXY 3690 MP. Measuring transducer for air oxygen

Supratec Gesellschaft für Umweltund Verfahrenstechnik mbh OXYFLEX - M T / M T M E M B R A N E D I S C D I F F U S ER AERATION TECHNOLOGY

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Oxygen Dipping Probe PSt3 / PSt6 / PSt9

HI 9143, HI 9143M HI 9145

Instruction Manual Differential Pressure Transmitter

Oxygen Sensor with Electrode

Dissolved Oxygen Sensor

EcoCell Vertical Electrophoresis Unit

Best Practice for Calibrating LTH Conductivity Instruments

PRODUCT SHEET. Order probe only as RXPROBE02

High-performance submersible pressure transmitter For level measurement Model LH-10

testo Leakage detector for refrigerants Instruction manual

Expert Hydrostatic Level Transmitters

QUICK START GUIDE TO DRINKING WATER MONITORING

Operating Manual ALU 7 - ALU 10 - ALU 20 - ALU 26 ALU 35 - ALU 60 - ALU 100

Instruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

High-performance submersible pressure transmitter For level measurement Model LH-10

Installation and Maintenance Instruction Manual

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

Instruction Manual Contact Pressure Gauge

9408 Series Dissolved Oxygen Systems. Dissolved oxygen systems designed for reliable operation with minimal operating costs

OxyCheq Expedition-X Oxygen Analyzer. Operator s Manual

Installation and Maintenance Instruction Manual

Vinmetrica Dissolved Oxygen System User Manual

Operating Instructions Melt Pressure Sensor

& Dissolved Oxygen Sensor. Instruction Manual

Operation Manual. O2 Quickstick. Oxygen Analyzer 08.17

Operation Manual. O2 Quickstick. Oxygen Analyzer

Note: the lock-out circuit must be in accordance with Section 8.7 of DIN/VDE Twin thermostats ATH.-SW-2020 ATH.-SW-2070 ATH.

NitraVis 700/1 IQ NitraVis 700/5 IQ MIQ/VIS

Oxygen Measurement Systems High Reliability and Wide Application Coverage

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Oxygen. Oxi Primer. Basic principles

RAM 4021 Operation Manual

ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD

ABB MEASUREMENT & ANALYTICS DATA SHEET series Dissolved oxygen systems

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

D i s s o l v e d O x y g e n M e a s u r e m e n t

How to specify a product. Process Sensors and Mechanical Instruments

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

Instruction Manual DO 6. Economy Hand-held Dissolved Oxygen Meter. 68X Rev 2 Apr 08. Technology Made Easy... Part of Thermo Fisher Scientific

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

MULTICHANNEL. Labnet International, Inc.

Aerobic Respiration. Evaluation copy

Instruction Manual. Alfa Laval SB Pressure Exhaust Valve ESE02965-EN Original manual

UsER manual for Watersens ph -REDOX

Non-Membrane Disinfection Sensors Instruction Manual

OxiQuant S. Operating Instructions

Rosemount 140/141/142

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

LDO II AQ 2/2014, Edition 1.5

CarboVis 700/1 IQ CarboVis 700/5 IQ MIQ/VIS

Transcription:

Operating manual Dissolved Oxygen Depth Armature ba25302e05 04/2009

Copyright Weilheim 2009, WTW GmbH Reprinting - even as excerpts - is only allowed with the explicit written authorization of WTW GmbH, Weilheim. Printed in Germany. 18 ba25302e05 04/2009

Contents - Contents 1 Overview..................................... 20 2 Safety instructions............................. 21 3 Commissioning............................... 21 4 Measuring / Operation.......................... 22 4.1 Calibration................................... 22 4.2 Measuring................................... 22 4.3 Storage...................................... 22 5 Maintenance, cleaning, replacement.............. 23 5.1 General maintenance notes...................... 23 5.2 Outside cleaning.............................. 23 5.3 Changing the electrolyte and membrane cap........ 24 5.4 Cleaning the electrodes......................... 26 5.5 Checking the sensor for freedom from zero-current... 28 5.6 Disposal..................................... 28 6 What to do if................................... 29 7 Technical data................................ 30 8 Wear parts and accessories..................... 32 ba25302e05 04/2009 19

Overview 1 Overview Structure 1 2 3 4 5 6 7 8 9 10 11 1 Protective hood 2 WP 90 membrane cap (filled with electrolyte solution) 2 Shaft 4 Connection head 5 8-pin plug 6 Protective cap for plug 7 Gold working electrode (cathode) 8 Insulator 9 Lead counter electrode (anode) 10 Ventilation area 11 Temperature sensor and auxiliary electrode Recommended fields of application On-site measurements in rivers, lakes and waste water and measurements in great water depths up to 100 m. 20 ba25302e05 04/2009

Safety instructions 2 Safety instructions This operating manual contains special instructions that must be followed during the operation of the. Always keep this operating manual available in the vicinity of the. Special user qualifications General safety instructions The membrane cap of the D.O. sensor is filled with a small amount of an alkaline electrolyte solution. All maintenance work that requires dealing with the electrolyte solution must only be carried out by persons who know how to safely deal with chemicals. The individual chapters of this operating manual use safety labels like the one below to indicate danger: CAUTION indicates instructions that must be followed precisely in order to avoid slight injuries or damage to the instrument or the environment. 3 Commissioning Scope of delivery D.O. sensor, filled with electrolyte solution and ready to operate Calibration and storage vessel, OxiCal -SL ZBK-325 accessory kit, comprising: 3 exchange membrane caps WP -90 Electrolyte solution ELY/G Cleaning solution, RL/G Polishing strip, SF 300 Operating manual The membrane cap that is mounted on the sensor for delivery serves mainly as a transport protection. Depending on the duration of the transport and storage period, it may have a shortened operational lifetime. If the measuring system cannot be calibrated (error message of the instrument), please proceed according to section REPLACING THE ELECTROLYTE SOLUTION AND MEMBRANE CAP. Preparing the sensor for measurement Pull the protective cap off the plug and connect the sensor to the meter. The sensor is immediately ready to measure. It is not necessary to polarize the sensor. Put the protective cap on the plug again after disconnecting the sensor so the plug contacts will not become dirty. ba25302e05 04/2009 21

Measuring / Operation 4 Measuring / Operation 4.1 Calibration For calibration, please refer to the operating manual of the measuring instrument. 4.2 Measuring the required minimum depth of immersion and minimum approach flow (see chapter 7 TECHNICAL DATA). The minimum flow can be provided in different ways, e. g.: The flow of the water to be measured is sufficient (aeration tank, water pipe, stream) Slowly pull the sensor through the water by hand (lake, container), or Use a flow aid such as a battery stirrer (see chapter 8 WEAR PARTS AND ACCESSORIES) 4.3 Storage Always store the sensor in the calibration and storage vessel at a temperature in the range 0... 50 C (32... 122 F). Make sure that the sponge in the calibration and storage vessel is always moist. OxiCal -SL calibration and storage vessel 1 2 Moisten the sponge: Remove the cap (1). Take out the sponge (2), wet it, then slightly squeeze it out. Insert the sponge again and close the calibration and storage vessel with the lid. 22 ba25302e05 04/2009

Maintenance, cleaning, replacement 5 Maintenance, cleaning, replacement 5.1 General maintenance notes For your safety the following safety instructions when handling electrolyte and cleaning solutions: CAUTION The ELY/G electrolyte solution and RL-G cleaning solution irritate the eyes and skin. the following points when dealing with these solutions: During working activities, always wear suitable protective gloves and protective goggles/face shield. If the solutions come into contact with the skin, rinse thoroughly with water and immediately change contaminated clothing. If the solutions come into contact with the eyes, rinse thoroughly with water and consult a doctor. the safety datasheets. CAUTION Before all maintenance activities, disconnect the sensor from the instrument. To exchange the electrolyte solution and membrane head and to clean the electrodes, screw off the protective hood. Information on how to order wear parts and maintenance equipment can be found in chapter 8 WEAR PARTS AND ACCESSORIES. 5.2 Outside cleaning Cleaning agents Contamination Lime sediments Fat/oil Cleaning procedure Immerse in acetic acid for 1 minute (volume share = 10 %) Clean with warm water that contains washing-up liquid After cleaning, thoroughly rinse with deionized water and recalibrate if necessary. ba25302e05 04/2009 23

Maintenance, cleaning, replacement 5.3 Changing the electrolyte and membrane cap CAUTION Before starting to work with the sensor, please note the GENERAL MAINTENANCE INSTRUCTIONS on page 23. General information WTW delivers the sensor ready to operate (see section 3). The electrolyte solution and membrane cap must only be replaced if: a calibration error occurs and the membrane is heavily contaminated the membrane is damaged the electrolyte solution is exhausted. in case of a leak message by the measuring instrument Changing the electrolyte and membrane cap Unscrew the membrane cap. Caution: Electrolyte solution! For disposal of the membrane head and electrolyte solution, see section 5.6. Rinse the sensor head with deionized water. Carefully rub and dry the counter electrode with a lintfree paper towel. RL/G Immerse the sensor head including the counter electrode in RL/G cleaning solution. Allow to react for 1 to 3 minutes. Thoroughly rinse the sensor head with deionized water. H O 2 Water the counter electrode in deionized water for at least 10 minutes. 24 ba25302e05 04/2009

Maintenance, cleaning, replacement ELY/G Carefully shake off the drops of water. Fill a new membrane cap with ELY/G electrolyte solution. Remove any air bubbles by carefully tapping the membrane head. Additionally, you can prevent air bubbles by throwing the first filling away and refilling the membrane cap. ELY/G 4 mm Thoroughly rinse the sensor head with electrolyte solution. Hold the sensor inclined and screw on the membrane head fingertight using a paper towel. Excess electrolyte solution is forced out of the ventilation area. Check the filling: Inspect the face surface. No air bubbles may be present within the dashed circle. Air bubbles outside this area do not interfere. For measurements under high pressure the filling must be completely free of air bubbles. Readiness to measure After approx. 30 to 50 minutes, the sensor is ready for operation. Subsequently calibrate the sensor. If you want to measure very low oxygen concentrations (< 0.5 % saturation), we recommend to let the sensor rest overnight and then calibrate it. ba25302e05 04/2009 25

Maintenance, cleaning, replacement 5.4 Cleaning the electrodes CAUTION Before starting to work with the sensor, please note the GENERAL MAINTENANCE INSTRUCTIONS on page 23. General information Cleaning is only required in cases of slopes too low or too high (sensor cannot be calibrated) that cannot be resolved by changing the membrane head and electrolyte solution. Cleaning the electrodes SF 300 Unscrew the membrane cap. Caution: Electrolyte solution! For disposal of the membrane head and electrolyte solution, see section 5.6. Rinse the sensor head with deionized water. Using the rough side of the wet SF 300 polishing strip, polish off any contamination from the gold working electrode using light pressure. Caution: Do not use any conventional sandpaper or glass-fiber brushes. Rinse the sensor head with deionized water. Wipe the counter electrode with a lint-free paper towel and carefully remove any loose white deposits. RL/G Immerse the sensor head including the counter electrode in RL/G cleaning solution. Allow to react for 1 to 3 minutes. 26 ba25302e05 04/2009

Maintenance, cleaning, replacement Thoroughly rinse the sensor head with deionized water. H O 2 Water the counter electrode in deionized water for at least 10 minutes. Carefully shake off the drops of water. ELY/G ELY/G Fill a new membrane cap with ELY/G electrolyte solution. Remove any air bubbles by carefully tapping the membrane head. Additionally, you can prevent air bubbles by throwing the first filling away and refilling the membrane cap. Rinse the sensor head with electrolyte solution. 4 mm Hold the sensor inclined and screw on the membrane head fingertight using a paper towel. Excess electrolyte solution is forced out of the ventilation area. Check the filling: Inspect the face surface. No air bubbles may be present within the dashed circle. Air bubbles outside this area do not interfere. ba25302e05 04/2009 27

Maintenance, cleaning, replacement For measurements under high pressure the filling must be completely free of air bubbles. Readiness to measure After approx. 30 to 50 minutes, the sensor is ready for operation. Subsequently calibrate the sensor. If you want to measure very low oxygen concentrations (< 0.5 % saturation), we recommend to let the sensor rest overnight and then calibrate it. 5.5 Checking the sensor for freedom from zero-current The sensor is zero-current free. Checking the module for freedom from zerocurrent is only necessary in the case of malfunctions that cannot be remedied by exchanging the electrolyte solution and membrane cap or by cleaning the electrodes. There are 2 possibilities to check the sensor for freedom from zero-current: Measurement in a nitrogen atmosphere (recommended method) Measurement in a sodium sulfite solution according to DIN EN 25814/ ISO 5814. CAUTION If you check the sensor according to DIN EN 25814/ISO 5814, do not leave the sensor in the sodium sulfite solution for more than 2 minutes. Danger of sensor poisoning! Test criterion The sensor is OK if the measuring instrument displays < 1 % D.O. saturation after 2 minutes. 5.6 Disposal CAUTION The ELY/G electrolyte solution irritates the eyes and skin. When dealing with the ELY/G electrolyte solution, observe the following points: During working activities, always wear suitable protective gloves and protective goggles/face shield. If it comes into contact with the skin, rinse thoroughly with water and immediately change contaminated clothing. If it comes into contact with the eyes, rinse thoroughly with water and consult a doctor. Follow the safety datasheet. 28 ba25302e05 04/2009

What to do if... Sensor and membrane cap Electrolyte solution For disposal, unscrew the membrane head and rinse the sensor and membrane head with water. We recommend disposing of the sensor without the membrane head as electronic refuse. The membrane head may be disposed of with the household refuse. Disposal according to the safety data sheet. 6 What to do if... Error symptom Cause Remedy The sensor is in the air and the display shows 0.0 mg/l or 0 % O 2 The sensor cannot be calibrated The sensor still cannot be calibrated after changing the electrolyte and membrane head Leak display appears Incorrect temperature display Mechanical damage to the sensor Meter displays OFL (display range exceeded) No connection between measuring instrument and sensor No electrolyte in the membrane head Cable defective Contaminated membrane head Electrolyte depleted Contaminated electrodes or sensor toxification Membrane cap not screwed on tight enough Hole in the membrane Check connection between measuring instrument and sensor Replace and refill the membrane cap (see section 5.3) Return the sensor Replace and refill the membrane cap (see section 5.3) Subsequently, wait for 30 to 50 min and recalibrate. Clean the electrodes (see section 5.4) Screw membrane head tighter Replace and refill the membrane cap (see section 5.3) Temperature sensor defective Return the sensor Short-circuit between working electrode and counter electrode Return the sensor Clean the electrodes (see section 5.4). If the meter still displays OFL, return the sensor. ba25302e05 04/2009 29

Technical data 7 Technical data General features Measuring principle Membrane covered galvanic sensor Temperature compensation Temperature sensor IMT compensation (calculated by the meter) Integrated NTC 30 (30 k at 25 C / 77 F) Dimensions (in mm) 166 246 38 Weight Approx. 800 g (without cable) Materials Working electrode Gold Counter electrode Lead Shaft Membrane head Protective hood POM Membrane FEP, 13 μm Sensor head Epoxy, PEEK Thermistor housing VA steel 1.4571 Connection head VA steel 1.4571 Seals FPM (Viton) Cable screw joint Brass, nickel-plated Cable coating PUR Connection cable Lengths 25... 100 m Diameter 8 mm Smallest allowed bend radius Fixed installation: Flexible use: Plug type Socket, 8 pins 50 mm 120 mm Pressure resistance Armature IP 68 (10 bar) Connection cable IP 68 (10 bar) Plug IP 67 (when plugged in) The meets the requirements according to article 3(3) of the 97/23/EC directive ("Pressure equipment directive"). 30 ba25302e05 04/2009

Technical data Measurement conditions Storage conditions Characteristics when delivered Measuring ranges at 20 C (68 F) Temperature range Max. allowed overpressure Depth of immersion Operating position Approach flow Recommended storing method Storage temperature Zero signal Response time at 20 C (68 F) Own consumption of oxygen at 20 C (68 F) Drift Response time of temperature measurement Precision of temperature measurement Working life 0... 50 mg/l D.O. 0... 600 % D.O. saturation 0... 1250 mbar D.O. partial pressure 0... 50 C (32... 122 F) 10 6 Pa (10 bar) min. 60 mm max. 100 m (depending on the cable length) Any > 3 cm/s at 10 % measurement accuracy 10 cm/s at 5 % measurement accuracy 18 cm/s at 1 % measurement accuracy In the calibration and storage vessel, OxiCal -SL (moist) 0... 50 C (32... 122 F) < 0.1 % of the saturation value t 90 (90 % of the final value display after)< 10 s t 95 (95 % of the final value display after)< 16 s t 99 (99 % of the final value display after)< 60 s 0.008 μg h -1 (mg/l) -1 Approx. 3 % per month in the operating condition t 99 (99 % of the final value display after) <60s ± 0.2 K min. 6 months with one electrolyte filling Pin assignment ba25302e05 04/2009 31

Wear parts and accessories 8 Wear parts and accessories Wear parts and maintenance equipment Description Model Order no. Set of exchange membrane caps (3 pieces) WP 90/3 202 725 Electrolyte solution ELY/G 205 217 Cleaning solution for lead counter electrode RL/G 205 204 Polishing strip SF 300 203 680 Accessory kit, comprising: 3 exchange membrane caps WP 90 Polishing strip, SF 300 Electrolyte solution ELY/G Cleaning solution, RL/G ZBK 325 202 706 Accessories Description Model Order no. Calibration and storage vessel OxiCal -SL 205 362 Battery-powered stirrer for depth measurements - provides a constant, defined flow to the sensor BR 325 203 826 For further accessories, refer to the WTW catalog or the Internet. 32 ba25302e05 04/2009