OMNIPORT 30. Multifunctional Hand-Held. Data-Logging & Data-Management. Features

Similar documents
HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

CALIBRATION SERVICES HUMIDITY DEW POINT AIR VELOCITY MASS FLOW TEMPERATURE CO 2 PRESSURE. (+34)

Pneumatic high-pressure controller Model CPC7000

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N

Hand-held pressure calibrator with integrated pump Model CPH6600

Pneumatic high-pressure controller Model CPC7000

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Precision digital pressure gauge Model CPG1000

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

Expert Hydrostatic Level Transmitters

HUMOR 20 + Automatic Calibration Module

Mass Flow Meter (MFM) for Gases

Precision pressure sensor Basic version Model CPT6020

Technical Information Conducal CLY421

Unique mounting features for Thermal Mass Flow Meters. By Martin Raab in cooperation with CaTeC b.v.

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

KMT. Thermal Mass Flowmeter. for compressed air and gases. Measuring range: Nm³/h Nm³/h

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators

Pneumatic service kit Model CPG-KITP

Digital pressure gauge Model CPG500

Industrial pressure controller Model CPC4000

Optical Dissolved Oxygen Meter

High-speed pressure sensor Model CPT6140

FAS-W. Features. Applications. Automatic condensation hygrometer

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Mass Flow Controller (MFC) for Gases

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Mass Flow Controller (MFC) for Gases

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

The affordable consumption counter for compressed air and gases R 3 /4 (DN 20)

FPG8601 Force Balanced Piston Gauge

Gas density monitor With integrated transmitter Model GDM-100-TI

Digital dead-weight tester Model CPD8500

SITRANS P measuring instruments for pressure

Automatic Isokinetic Sampler. ST5 Evo

Digital pressure gauge Model CPG500

GMC-I Service GmbH Calibration Center

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

Additel 761 Automated Pressure Calibrators

SonoMeter 30 Energy Meters

How to specify a product. Process Sensors and Mechanical Instruments

Technical Data Sheet MF010-O-LC

Transmitter CS 21 Operation Manual

Digital deadweight tester Model CPD8500

Pressure transmitter PASCAL Ci4

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

MANUAL KPS Pressure Control Valve

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Additel 780 Series Pressure Controller

Hydraulic pressure balance Model CPB5800

Optical Dissolved Oxygen Meter

Instruction Manual. Model DSP-Ex Portable Dewpoint Meter. Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England

Additel 761 Automated Pressure Calibrators

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2

DTG - LCD Digital Temperature Gauge USER MANUAL

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

ADT 761 Automated Pressure Calibrator

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

F&J SPECIALTY PRODUCTS The nucleus of quality air monitoring programs

Deadweight Tester / Pressure Balance High pressure up to 5,000 bar / 70,000 psi CPB5000-HP. Applications. Special features. Description. Rel.

Pressure Measurement Single-range transmitters for general applications

TH-1800-T TRX-700-CNG Converter

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

Pneumatic dead-weight tester Model CPB3500

Series 7250 Ruska High-Speed Digital Pressure Controller. GE Sensing. Features

AMT-Ex Dewpoint Transmitter

Model PDT Dewpoint Transmitter

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications

Series Ruska Digital Pressure Indicator. GE Sensing & Inspection Technologies. Features

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

Calibration certificates

deltaflowc deltaflowc Venturi or Probe

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Dead-weight tester High-pressure version Model CPB3800HP

Calibration equipment

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

Visualize Nitrogen Gas Consumption

HumiSys HF High Flow RH Generator

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Pressure is our Business

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

CO2 incubator with additional process controls

High-performance submersible pressure transmitter For level measurement Model LH-10

FTC130 Transmitter. Operating Manual

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Pressure Measurement Single-range transmitters for general applications

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

Sartorius CCL kg Prototype Mass Comparator

BUYER S GUIDE AQUAlogger 530WTD

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

...makes sense! Combined CO 2 /O 2 analyzers. Monitor your process in real-time: OUR CER. BlueSens.com

Transcription:

OMNIPORT 30 The robust multifunctional hand-held meets the highest requirements and comes with a wide range of accurate probes that fit various applications. Use touch-screen navigation to show, up to three measurement values simultaneously on the capacitive TFT display. OMNIPORT 30 Multifunctional Hand-Held A total of 23 measurands (vary according to probe) is available, including: relative humidity RH temperature T dew point temperature Td absolute humidity dv mixing ratio r air velocity v volumetric flow air pressure p CO 2 ppm with RH/T probe with CO 2 probe Store measurement values in the internal memory of the device and use the free SmartGraph3 software to manage data on your PC. The optional carrying case accommodates the hand-held and probes, as well as accessories. Data-Logging & Data-Management The Omniport 30 offers both continuous and single-point datalogging. The measurement values of up to three channels are stored simultaneously, together with a time and date stamp, in the internal memory of the device. Stored measurement data, as well as the minimum, maximum, average and standard deviation values can be shown directly on the display. Scroll through a recorded measurement and switch between graphs by using the control cross. Data management is easy and intuitive by using the free SmartGraph3 software to create graphs that contain measurement channels of interest for better data analysis. Data can be exported in.csv format and then imported into EXCEL for further processing. Features Data logging Internal memory for 2 million measured values 23 physical quantities Capacitive TFT touch screen Displays measurands simultaneously Real-time HOLD / MIN / MAX / AVG readout Integrated air pressure sensor User friendly operation Free data management software 62 v1.5 / Modification rights reserved OMNIPORT 30

Technical Data General Power supply 4 x Alkaline LR6 AA batteries, 1.5 V (not in the scope of supply) Optional power supply 5V DC via USB (cable included) Temperature range operating: handheld and handle of sensing probe: 0...50 C (32...122 F) storage: -20...60 C (-4...140 F) Internal memory for approx. 2 million measured values Housing / protection class ABS / IP40 Dimensions (HxWxD) 170 x 62 x 34 mm (6.69 x 2.44 x 1.34 ) Weight ca. 205g (0.45 lbs) Display TFT display, 54 x 41 mm (2.13 x 1.61 ), illuminated CE compatibility Hand-held: EN61000-6-2:2005 EN61000-6-3:2007 Logprobe: EN61326-1:2013 EN61326-2-3:2013 Integrated air pressure sensor Measuring range 800 to 1100 mbar (complete accuracy) Accuracy max. ± 0.5 mbar (at 25 C, 1013.25 mbar) Long term stability typ. -1 mbar/year HUMIDITY / TEMPERATURE PROBES LOGPROBE 20 - compact, pluggable HVAC probe 43 (1.7 ) 32 (1.3 ) Ø12 (0.47 ) LOGPROBE 16 - HVAC probe 70 (2.8 ) 12 (0.47 ) 32 (1.3 ) Working range: 0...100% RH / -40...80 C (-40...176 F) Accuracy: ±2% RH (0...90% RH), ±3% RH (90...100% RH) @20 C / 68 F ±0.2 C / ±0.36 F @20 C / 68 F max. ±0.6 C / ±1.08 F (-40...80 C / -40...176 F) Order code: LOGPROBE20-HTPC Response time τ 90 : 30 sec. Filter: Membrane filter Order code: LOGPROBE20-HTPA Response time τ 90 10 sec. Filter: Plastic grid filter Working range: 0...100% RH / -20...70 C (-4...158 F) Accuracy: ±2% RH (0...90% RH), ±3% RH (90...100% RH) @20 C / 68 F ±0.2 C / ±0.36 F @20 C / 68 F max. ±0.5 C / ±0.9 F (-20...70 C / -4...158 F) Response time τ 90 : 7 sec. Order code: LOGPROBE16 LOGPROBE 31 - high temperature probe LOGPROBE 30 - confined space probe OMNIPORT 30 250 (9.9 ) 32 (1.3 ) 12 (0.5 ) 250 (9.9 ) 5 (0.2 ) v1.5 / Modification rights reserved Working range: 0...100% RH / -40...180 C (-40...356 F) (grip of sensing probe up to 50 C/122 F) Accuracy: ±2% RH (0...90% RH), ±3% RH (90...100% RH) @20 C / 68 F ±0.2 C / ±0.36 F @20 C / 68 F max. ±0.6 C / ±1.08 F (-40...180 C / -40...356 F) Response time τ 90 : 30 sec. Temperature dependency: RH: ±0.03% RH/ C (% RH/1.8 F) Order code: LOGPROBE31 Working range: 0...100% RH / -40...100 C (-40...212 F) Accuracy: ±2% RH (0...90% RH), ±3% RH (90...100% RH) @20 C / 68 F ±0.2 C / ±0.36 F @20 C / 68 F max. ±0.6 C / ±1.08 F (-40...100 C / -40...212 F) Response time τ 90 : 15 sec. Temperature dependency: RH: ±0.03% RH/ C (% RH/1.8 F) Order code: LOGPROBE30 63

AIR VELOCITY PROBES LOGPROBE 61/60 - stainless steel probe 200 (7.9 ) 12 (0.5 ) 6 (0.2 ) Working range: 0.08...2m/s (15...400ft/min) 0.2...20m/s (40...4000ft/min) -20...70 C (-4...158 F) -20...70 C (-4...158 F) Accuracy: ± (0.04m/s / 8ft/min+ 1% of m. v.) ± (0.2m/s / 39ft/min + 2% of m. v.) ± 0.7 C / ±1.26 F (0...50 C / 32...122 F) ± 0.7 C / ±1.26 F (0...50 C / 32...122 F) Response time τ 90 : 1.5 sec. 1.5 sec. Order code: LOGPROBE61 LOGPROBE60 LOGPROBE 65 - polycarbonate probe 200 (7.9 ) 18 (0.7 ) 12 (0.5 ) Working range: Accuracy: Response time τ 90 : 1.5 sec. Order code: LOGPROBE65 0.2...20m/s (40...4000ft/min) / 0...50 C (32...122 F) ± (0.2m/s / 39ft/min + 3% of m.v.) ± 1 C / ±1.8 F (0...50 C / 32...122 F) CO 2 PROBE LOGPROBE 802/805/810 - CO 2 probe 96 (3.8 ) 18.5 (0.7 ) Working range: 0...2000 / 5000 / 10000ppm Technology: dual wave NDIR with autocalibration Accuracy at 25 C 0...2000ppm: < ± (50ppm +2% of measured value) and 1013mbar 0...5000ppm: < ± (50ppm +3% of measured value) (77 F and 14.69psi) 0...10000ppm: < ± (100ppm +5% of measured value) Warm-up time: 3 min. Temperature dependency: typ. 1ppm CO 2 / C (-20...45 C) (-4...113 F) Order code: 0...2000ppm LOGPROBE802 0...5000ppm LOGPROBE805 0...10000ppm LOGPROBE810 Carrying Case The optional carrying case protects the handheld, probes and accessories during transport and storage. It helps to avoid mechanical damage, as well as the contamination of the sensors, which is essential for the optimal long term performance of the instrument. Protective Cover The optional cover protects the handheld device during usage in dirty or oily environments. The integrated magnetic plate allows an easy temporary fixing of the handheld onto a metallic surface on site, while the hang-on straps helps keep your hands free while taking measurements. HA040906 HA040907 64 v1.5 / Modification rights reserved OMNIPORT 30

CO 2 LOGPROBE 802-0...2000ppm LOGPROBE802 Ordering Guide Pluggable Probes 1) Remote Probes 2) POSITION 1 BASIC DEVICE OMNIPORT30 OMNIPORT30 POSITION 2 CABLE 2m (6.6ft) HA010813 POSITION 3 PROBES Humidity / Temperature LOGPROBE 20 - Response time 30 sec. LOGPROBE 20 - Response time 10 sec. LOGPROBE 16 - HVAC probe LOGPROBE 31 - high temperature probe LOGPROBE 30 - confined space probe Air Velocity LOGPROBE 61 - stainless steel probe / 0.08...2m/s (15...400ft/min) LOGPROBE 60 - stainless steel probe / 0.2...20m/s (40...4000ft/min) LOGPROBE 65 - polycarbonate probe / 0.2...20m/s (40...4000ft/min) LOGPROBE20-HTPC LOGPROBE20-HTPA LOGPROBE16 LOGPROBE31 LOGPROBE30 LOGPROBE61 LOGPROBE60 LOGPROBE65 LOGPROBE 805-0...5000ppm LOGPROBE 810-0...10000ppm LOGPROBE805 LOGPROBE810 POSITION 4 CARRYING CASE For basic device and up to 4 probes HA040906 HA040906 1) Directly connected to device, cable is optional 2) Cable is necessary Order Example Pluggable Probes: Position 1 - Basic Device OMNIPORT30 Position 2 - Probe LOGPROBE805 Position 3 - Carrying Case HA040906 Accessories Carrying case for basic device, 2 pluggable and 2 remote probes HA040906 Remote Probes: Position 1 - Basic Device Position 2 - Cable Position 3 - Probes Position 4 - Carrying Case OMNIPORT30 HA010813 LOGPROBE16 LOGPROBE61 HA040906 Protective cover HA040907 Membrane filter PC (for 12mm RH/T probes) HA010118 Metal grid filter PC (for 12mm RH/T probes) HA010119 Stainless steel sintered filter (for 12mm RH/T probe) HA010103 Plastic grid filter PC (for Logprobe 20-HTPA) Cable for remote probes 2m (6.6ft) Humidity standards / Calibration device SmartGraph 3 - data management software HA010121 HA010813 refer to data sheet Humidity Calibration Set free download at www.epluse.com/smartgraph3 OMNIPORT 30 v1.5 / Modification rights reserved 65

%RH 5 4 3 2 1 0 0 10 20 30 40 50 60 70 80 90 100 %RH 3 ºC 2 ºC 1 ºC 0 ºC -40 ºC -40 ºF 0 ºC 32 ºF 40 ºC 104 ºF 80 ºC 176 ºF 5.4 ºF 3.6 ºF 1.8 ºF 0 ºF 5 ºC 4 ºC 3 ºC 2 ºC 1 ºC 0 ºC 9.0 ºF 7.2 ºF 5.4 ºF 3.6 ºF 1.8 ºF %RH 0 10 20 30 40 50 60 70 80 90 100 35 mm Ø 13,7 mm 37,2 mm

HUMLOG20 The HUMLOG20 facilitates exact and professional recordings for climatic measurements of humidity, temperature, air pressure and CO 2 concentration. The long battery life and large memory allow for continuous data recording over long periods of time. The configuration of the data logger and the evaluation of the measurement data are simple and straightforward using SmartGraph3 software, which is included in the scope of supply. The built-in Ethernet interface makes the HUMLOG20 Network capable, and ensures maximum reliability in data transmission. For various requirements in the application, the four models THI, THIP, TCO and E are available. The Model E offers the highest flexibility with analog and digital interface for external sensors. Model Measurement Categories THI THIP TCO E Temperature (air) Relative humidity Absolute humidity Dew point temperature Barometric air pressure Relative air pressure CO 2 Concentration External input - digital RH/T-Sensor External input - Pt100, Thermocouple Analog input voltage 0-1V Analog input current 0/4-20mA Functions Power supply battery Power supply USB Power supply LAN (PoE) optional optional optional optional Measured data storage 3,200,000 3,200,000 3,200,000 3,200,000 Typical battery life > 1 year > 1 year > 4 months > 4 months LC-display One-button operation 1-point calibration by operator C/ F switchable Optical / acoustical alarm Date / time Records MIN/MAX/AVG SmartGraph3 evaluation software Functions Software Graphical representation Numerical data display Print function Export function (e.g. Excel) Gathered printouts of all measurement sites User administration Administration of up to 255 data logger Data logger for Humidity, Temperature, Air Pressure and CO 2 HUMLOG20 THI HUMLOG20 THIP HUMLOG20 TCO HUMLOG20 E Typical Applications Features museums and exhibition spaces large data memory clean rooms large format display warehouses USB and Ethernet interface electronic-data-processing centres network-capable calibration laboratories powerful software for data analysis 70 v2.4 / Modification rights reserved HUMLOG20

HUMLOG20 E Configurations Examples The HUMLOG20 E is equipped with an digital input, which allows the connection of up to four external humidity/temperature sensors. Two additional analog inputs for sensors with voltage or current output, Pt100 temperature sensors in 3 and 4 wire technology or Thermocouple J, K and S offers highest flexibility in the application. Each fully equipped HUMLOG20 E is a 10 channel data logger that can record various data. Sensor 4 Humidity/Temperature sensor LOGPROBE 20 Sensor 3 Sensor 2 Sensor 1 2 x Analog input: 4...20mA 0...20mA 0...1V Pt100 3-wire Pt100 4-wire Thermocouple K,J,S max. 150 m Software SmartGraph3 With SmartGraph3 the gathering of measured data is simple and as intuitive as possible: An HUMLOG20 data logger is automatically recognized and added as a network device. In addition to its data-readout function, the software possesses a recording mode that enables parallel recording to be displayed on the computer. The data from any desired number of HUMLOG20 devices can be read out simultaneously. The zoom function allows for quick analyses of critical time periods. The exporting of measured data in csv format enables it to be imported into EXCEL. The device configuration can be printed out in order to check installation parameters. Alarm limits - like the measured data - are chronologically managed at various times so that when changes in alarm limits occur, they can be retracted. Automatic data readout of all measured data is supported. HUMLOG20 v2.4 / Modification rights reserved 71

Technical Data General Dimensions length 166 mm, width 78 mm, depth 32 mm Housing / protection class plastic ABS / IP40 Battery lifetime THI, THIP: > 1 year TCO, E: > 4 months Data storage 16 MB, 3,200,000 measured values LC-Display size 90x64 mm Weight approx. 250g Interface USB, LAN (Ethernet) Measurement rate 10/30s, 1/10/12/15/30min, 1/3/6/12/24h Storage rate 1/1012/15/30min, 1/3/6/12/24h Power supply Battery 4 x LRG AA Mignon (not in the scope of supply) or USB optionally the power supply via PoE (Power over Ethernet) is possible Working range Temperature: -20...50 C (-4...120 F) Humidity: 0...95%RH (non condensing) CE compatibility according EN61000-6-2 EN55022 EN6100-4-2 to EN6100-4-6 Measurements Relative Humidity Sensor capacitive Measurement range 10...95%RH Accuracy at 20 C ±2%RH Resolution 0.1%RH Temperature Sensor Measurement range Accuracy Resolution Air pressure (only Model THIP) Measurement range Accuracy at 25 C Resolution NTC -20...50 C (-4...120 F) ±0.3 C (0...40 C; 32...102 F), otherwise ±0.5 C 0.1 C 300...1300 hpa absolute ±0.5 hpa in the range of 700...1100 hpa 0.1 hpa CO 2 (only Model TCO) Sensor NDIR 2-Beam Principle Measurement range 0...5000 ppm Accuracy ± (50ppm +3% of measured value) Resolution 1 ppm Long-term stability 20 ppm/year Response time t 90 < 195s for measurement rate 10s Temperature dependence typ. 2ppm CO 2 / C (0...50 C / 32...122 F) different from 25 C (77 F) Voltage input 0-1V (only Model E) Measurement range 0...1V Accuracy ±(200μV +0,1% of measured value) Resolution 500μV Current input (only Model E) Measurement range 2-wires: 4...20mA 3-wires: 0...20mA Accuracy ±(4μA +0,1% of measured value) Resolution 5μA Resistance max. 50 Ohm Thermocouple K, J, S (only Model E) Measurement range for K, J: -200...1200 C for S: -50...1700 C Accuracy for -200...0 C: ±(1 C +0,5% of measured value) for 0...1700 C: ±(1 C +0,2% of measured value) Resolution 0,2 C Pt100 (only Model E) Measurement range -200...500 C Accuracy ±(0,2 C +0,1% of measured value) Resolution 0,02 C 72 v2.4 / Modification rights reserved HUMLOG20

Technical Data LOGPROBE20 General Housing / protection class plastic PC / IP65 Working range Temperature: -40...80 C (-40...176 F) Humidity: 0...100%RH CE compatibility according 1) EN61326-2-3 EN61326-1 Maximum cable length 150m Measurements Relative Humidity Sensor capacitive Measurement range relative humidity 0...100%RH absolute humidity 0...290 g/m 3 mixing ratio 0...550 g/kg dew point temperature -40...80 C (-40...176 F) Accuracy at 20 C ±2%RH (0...90%RH) ±3%RH (90...100%RH) Temperature Sensor Pt1000 DIN B Measurement range -40...80 C (-40...176 F) Accuracy ±0.2 C at 20 C (68 F); ±0.4 C (-10...50 C 14...122 F); ±0.6 (-40...80 C -40...176 F) 1) is not protected against surge Connection Diagram Dimensions mm (inch) 1...+UB 2...RS485 B 3...RS485 A 4...GND 47 (1.85) 32 (1.26) 12 (0.47) Ordering Guide DATA LOGGER Accessories - Data logger Temperature and relative humidity HUMLOG20 THI Power supply for HUMLOG20 HA030106 Temperature, rel. humidity, air pressure HUMLOG20 THIP theft-proof installation kit HA030104 Temperature, rel. humidity, CO 2 HUMLOG20 TCO external inputs HUMLOG20 E optional PoE (Power over Ethernet) -POE (add to the end) HUMIDITY/TEMPERATURE SENSOR for HUMLOG20 E Accessories - HUMLOG20 E RH/T-Sensor with metal grid filter LOGPROBE20-HTPC T-coupler M12 - M12 HA030204 RH/T-Sensor with stainless steel sintered filter LOGPROBE20-HTPD cable 2m (6.6ft) HA010816 cable 5m (16.4ft) HA010817 cable 10m (32.8ft) HA010818 male connector M12x1 self-assembled HA010706 female connector M12x1 self-assembled HA010708 Order Example HUMLOG20 THI HUMLOG20 TCO-POE Data logger for Temperature and relative Humidity Data logger for Temperature, relative Humidity and CO 2 with PoE (Power over Ethernet) HUMLOG20 v2.4 / Modification rights reserved 73

HUMOR 20 High-precision Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according to FDA guidelines in the pharmaceutical industry, etc., require that humidity instruments have a traceable, accurate calibration. The humidity calibrator HUMOR 20 developed by E+E is the ideal reference instrument for these requirements. The HUMOR 20 can be used in the humidity range of 10-95% RH both for monitoring cylindrical sensors (transmitters, hand-held instruments,...) and also for monitoring instruments with cubic dimensions (data loggers, wall instruments,...). A temperature sensor integrated in the measurement chamber also permits the monitoring of an optional temperature output. HUMOR 20 The HUMOR 20 is traceable to international standards and can be delivered with an official, internationally recognised OEKD calibration certificate. Due to its high accuracy, the HUMOR 20 is the basis for accredited calibration laboratories for relative humidity. Based on its operating principle, the HUMOR 20 can be used under typical conditions in a laboratory climate. This means that expensive, fully air-conditioned rooms are not necessary. For operation HUMOR 20 requires only distilled water, filtered oil-free Automatic Calibration Module air with a pressure of 10 bar and a power supply between 90-230V AC. The specimen can be powered by 24V DC that is available directly on the HUMOR 20. Operation The operation of the HUMOR 20 is based on a fundamental two-pressure process and thus is similar to instruments used in national bureaus for standards. Air or nitrogen at a pressure p 1 is led through a waterfilled saturation chamber and saturated to 100% RH at p 1. By means of a reduction valve, the saturated air is reduced to the ambient pressure p and fed into the measurement chamber. Due to the construction, the saturation chamber and the measurement chamber are at the same temperature. Under these conditions, the water-vapour partial pressure e ws is reduced at the same ratio as the total pressure. Essentially, the following applies: e = e ws * p / p 1 From this it follows that: RH = e / e ws = p / p 1 Air p 1 Pressure regulator p, T Schematic Illustration of a Two-pressure Reactor e Water T, p1 e ws Reduction valve p 1 --> p Measurement chamber Saturation chamber Thus, the generated relative humidity essentially depends on the ratio of the two pressures. Constructionspecific deviations from this ratio are corrected during factory adjustments. By adjusting the pressure p 1 the relative humidity is brought to the desired value in the measurement chamber. 166 v3.5 / Modification rights reserved HUMOR 20

Typical Applications calibration laboratories reference device bureau of standards manufacturers of measurement instruments Features highest accuracy traceable calibration independent of ambient temperature easy handling traceable to international standards OEKD certificatable Automatic Calibration Module The optional available Automatic Calibration Module enables an automatic set point adjustment of the desired reference humidity. With the software, included in the scope of supply, checkpoints, stabilisation times, etc. can be set. Furthermore the instrument allows for an automatic print out of a calibration protocol for a transmitter with analogue standard interface. Calibration and Adjustment using HUMOR 20 24V DC electrical supply for the test sample are provided directly at HUMOR 20. Furthermore, four inputs for the voltage or current outputs of transmitters are available when using the Automatic Calibration Module for generating calibration protocols. The software which is included in the scope of supply allows the user to record measurement values in a log file, to print out calibration protocols and to configure or to readjust the HUMOR 20. Software - Features: - Freely selectable numbers of measuring points and stabilisation times when using the Automatic Calibration Module - Creation and print out of professional calibration protocols with: - Specimen number - Calibration date - Reference and actual values - Temperature display can be switched between C and F - 1-point customer humidity calibration of the HUMOR 20-6-point customer humidity calibration of the HUMOR 20-1-point customer temperature calibration - Reset of HUMOR 20 to factory calibration HUMOR 20 v3.5 / Modification rights reserved 167

Technical Data General Function principle Working range Protection class Protection type Surge voltage category Installation altitude Application 1) 2) Accuracy of measurement two-pressure-reactor 10...95% RH I IP40 II up to 2000 m above sea level Indoors u(uw) [% RH] (k=2) Accuracy temperature measurement in measuring chambe 2) Power supply Work equipment Stabilisation time HUMOR 20 Stabilisation time specimen Integrated power supply Number of measuring inputs relative humidity Uw [% RH] typ. ±0.3 C (±0.54 F) 100...230V AC, 50/60Hz, max. 20W compressed air, filtered and free of oil or nitrogen N 2 with max. 10bar (145psi) distilled water < 3 min/measuring point typ. 20 min/messpunkt 24V DC, max. 200mA 4 (switchable between 4...20mA / 0...20mA / 0...1V / 0...5V / 0...10V) Typ. error for display inputs Voltage measuring: < 5mV Current measuring: < 30µA Display Dot-matrix display with backlight Gas flow 3 l/min or RH > 85% the gas flow is reduced to 1.5 l/min at 95% RH Recommended interval for 1 year recalibration Interface for PC connection RS232 (COM-Port) System requirements for software tools MS Windows 2000 mit SP 2 / Windows XP / Windows Vista Environmental conditions temperature: 10...40 C (50...104 F) humidity: 10...80% RH CE conformity EN61000-6-3:2007 EN61326-1:2006 EN61000-6-2:2006 EN61010-1:2010 Additional Standards EN60068-2-6 EN60068-2-29 Dimensions 400 x 260 x 240 mm (15.7 x 10.2 x 9.4 ) Weight HUMOR 20: about 23kg (51 lbs) HUMOR 20 incl. aluminium transport case: about 36.5kg (80.5 lbs) Measuring Chamber The construction of the measuring chamber allows the calibration and adjustment of cylindrical sensor probes with a diameter of 8-25.5mm (0.3-1 ) (hand-held instruments, duct-mounted versions,...) as well as of cubic measuring units (room transmitters, data loggers,...) with maximum dimensions of 100x85x40mm (3.9x3.3x1.6 ) or 95x95x40mm (3.9x3.9x1.6 ). By using the Plexiglas cover (standard supply), it is possible to calibrate and adjust compact room devices (e.g., the EE10) with the HUMOR 20. The overall accuracy of the calibration is influenced by the absence of the metal cover. The additional error depends on the position of the specimen in the chamber as well as on the relative humidity. 1) The extended inaccuracy of measurement results from the standard inaccuracy increased by a multiplying factor of K=2. 2) Valid for metal covers for the measuring chambers 168 v3.5 / Modification rights reserved HUMOR 20

Accessories Oil-free compressor Technical Data: Max. operation pressure Supply voltage Noise level Dimensions (l x w x h) Weight 12bar (174psi) 230V AC // 50 or 60Hz 57 db(a)/lm 410 x 410 x 500 mm (16 x 16 x 20 ) 21kg (46lbs) Optional covers for the measuring chambers Various covers for the measuring chamber accommodate probes of all diameters available on the market. With these covers up to four probes can be calibrated simultaneously. suitable for NUMBER OF FEEDTHROUGHS ordercode Humor cover 12-16mm (0.5-0.6 ) plane for 2 Probes HA020201 Humor cover 16-20.5mm (0.6-0.8 ) plane for 1 Probe HA020202 Humor cover 20.5-25.5mm (0.8-1 ) plane for 1 Probe HA020203 Humor cover 8-12mm (0.3-0.5 ) plane for 3 Probes HA020204 Humor cover 12-13mm (0,5-0,52 ) conic for 4 Probes HA020205 Humor cover 12-16mm (0.5-0.6 ) bevelled for 4 Probes HA020207 Humor cover 16-20.5mm (0.6-0.8 ) bevelled for 4 Probes HA020208 Humor cover 30mm (1,2 ) plane for 1 Probe HA020209 Adapter for EE33 - modell J 1) HA020401 1) only useable in combination with HA020204 or HA020201 Calibration certificate To meet the requirements of Quality Management Systems such as ISO9001 regarding calibration and certification of measurement and test instrumentation, the HUMOR 20 is available with an official OEKD accredited calibration certificate. Automatic Calibration Module For the fully automatic measurement of the characteristics of a transmitter. Technical Data: Weight Dimensions Supply Interface to PC Compressed air supply Protection type Protection class - weight of instrument: 9kg (20lbs) - instrument incl. aluminium transport case: 23kg (51lbs) 260x260x240mm (LxBxH); (10.2 x10.2 x9.4 ) 100...230V AC, 50/60 Hz max. 15W RS232 (COM Port) min. 9.8bar (142psi); max. 12bar (174bar); filtered oil-free compressed air, max. size of particle: 5μm IP40 I Pollutional index 2 Surge voltage category Installation altitude II up to 2000 m above sea level Application Indoors CE conformity EN61000-6-3:2007 EN61326-1:2006 EN61000-6-2:2006 EN61010-1:2010 Additional Standards EN60068-2-6 EN60068-2-29 HUMOR 20 v3.5 / Modification rights reserved 169

HUMOR 20 - Scope of Supply 1 2 7 8 3 9 10 11 12 4 13 5 14 6 1 Power supply cable IEC Europe (230V) + power supply cable IEC Northamerica (110V) 2 Water drain pipe with connector 3 Funnel 4 Allen key (10mm / 0.4 ) 5 Measuring beaker 6 Measuring and calibration software 7 Face pin wrench 8 Plexiglas cover for room transmitter testing 9 O-ring for room transmitter 10 Knurled nut 11 Cover for measuring chamber (ordering code HA0202xx) (not inlcuded in the scope of supply HUMOR 20) 12 Fixing bracket for filter set (pre-mounted) 13 Works certificate acc. DIN EN 10204-3.1 14 Filter set with oil separator Ordering Information HUMIDITY CALIBRATOR HUMOR 20 Automatic Calibration Module HUMOR20 HA020301 COVER FOR MEASURING CHAMBER Humor cover 12-16mm (0.5-0.6 ) plane - for 2 Probes HA020201 Humor cover 16-20,5mm (0.6-0.8 ) plane - for 1 Probe HA020202 Humor cover 20,5-25,5mm (0.8-1 ) plane - for 1 Probe HA020203 Humor cover 8-12mm (0.3-0.5 ) plane - for 3 Probes HA020204 Humor cover 12-13mm (0,5-0,52 ) conic - for 4 Probes HA020205 Humor cover 12-16mm (0.5-0.6 ) bevelled - for 4 Probes HA020207 Humor cover 16-20,5mm (0.6-0.8 ) bevelled - for 4 Probes HA020208 Humor cover 30mm (1,2 ) plane - for 1 Probe HA020209 Adapter for EE33 - modell J 1) HA020401 1) only useable in combination with HA020204 or HA020201 ACCESSORIES Oil-free compressor for 230V power supply ÖKD-calibration certificate USB <=> RS232 converter Face pin wrench adjustable HA020101 OEKD20/xH HA020110 HA020402 170 v3.5 / Modification rights reserved HUMOR 20

Humidity Calibration Kit The E+E Humidity Calibration Kit offers a cost effective method for calibrating humidity measuring devices with sensing probes Ø 10-12 mm (0.4-0.47 inch). It is very easy to use and it does not require highly qualified technical staff. The kit consists of a humidity calibration chamber and a choice of E+E Humidity Standard Sets. Humidity Standards: The E+E Humidity Standards are non-saturated salt solutions available in sets of five or fifty single-use ampoules, which may be stored an indefinite time. The salt solutions are non-harmful, handling them does not require specific safety measures. Safety data sheet is available upon request. Each E+E Humidity Standard Set is supplied with a traceable calibration certificate, issued by the Austrian National Metrology Institute (NMI). Calibration chamber Accuracy of the E+E Humidity Standards humidity value accuracy at 23 C (73.4 F) 0 % RH ±0.3 % RH 5 % RH ±0.5 % RH 10 % RH ±0.5 % RH 20 % RH ±0.5 % RH 35 % RH ±0.5 % RH 50 % RH ±0.9 % RH 65 % RH ±0.9 % RH 80 % RH ±1.2 % RH 95 % RH ±1.2 % RH Humidity Standard Set For calibration procedure using the Humidity Calibration Kit please see the user guide at www.epluse.com. Calibration Certificate Ordering Guide Humidity Standards order code Humidity Standards order code 5 ampoules 0 % RH + 5 textile pads HA010400 50 ampoules 0 % RH HA011500 5 ampoules 5 % RH + 5 textile pads HA010405 50 ampoules 5 % RH HA011505 5 ampoules 10 % RH + 5 textile pads HA010410 50 ampoules 10 % RH HA011510 5 ampoules 20 % RH + 5 textile pads HA010420 50 ampoules 20 % RH HA011520 5 ampoules 35 % RH + 5 textile pads HA010435 50 ampoules 35 % RH HA011535 5 ampoules 50 % RH + 5 textile pads HA010450 50 ampoules 50 % RH HA011550 5 ampoules 65 % RH + 5 textile pads HA010465 50 ampoules 65 % RH HA011565 5 ampoules 80 % RH + 5 textile pads HA010480 50 ampoules 80 % RH HA011580 5 ampoules 95 % RH + 5 textile pads HA010495 50 ampoules 95 % RH HA011595 Calibration Chamber for sensor probes 10...12 mm (0.4...0.47 ) HA010401 Textile pads 50 pcs. packed HA010498 200 v3.0 / Modification rights reserved Calibration Set

CALIBRATION SERVICES HUMIDITY DEWPOINT AIR VELOCITY MASS FLOW TEMPERATURE YOUR PARTNER IN SENSOR TECHNOLOGY Ges.m.b.H. R www.epluse.com

CALIBRATION Sophisticated metrology is one of the fundamental prerequisites for quality and progress in trade, industry, science, health and environmental protection. National standards are at the pinnacle of the hierarchy of measuring equipment. Every industrial nation has an authority that provides this measurement standard and verifi es its accuracy by international comparison measurements. In Austria this is the task of BEV - the National Metrology Institute. E+E Elektronik as a designated laboratory is commissioned to provide and further develop the national standard for humidity. Thanks to the direct traceability to an NMI (National Metrology Institute), a BEV certifi cate is of particular interest to accredited calibration authorities. ÖKD NMI BEV / PTP (National standards) Calibration authorities Calibration bodies OTHER AUTHORITIES Based on the agreements between the members of EA (European Cooperation for Accreditation) and ILAC (International Laboratory Accreditation Cooperation), calibration certifi cates issued by E+E conform to worldwide recognized standards. CALIBRATION IN A DESIGNATED NMI LABORATORY These national standards must be compared with the standards of other countries by means of key comparisons in order to be recognized internationally in line with the CIPM-MRA (international Mutual Recognition Agreement). The BEV calibration lab covers particularly extraordinary calibrations for special humidity measuring equipment. For the highest measurement authority in a country there is the opportunity to build expertise about the measurement variables. In addition, within the frame of the technical possibilities qualified measurements can be performed beyond the OEKD accreditation. Due to direct traceability with the NMI (National Metrology Institute), an NMI certifi cate is of particular interest to accredited calibration authorities.

CALIBRATIONS IN AN ACCREDITED OEKD LABORATORY The E+E OEKD laboratory is accredited in accordance with EN ISO/IEC 17025. The Austrian Federal Ministry of Economics, Family and Youth (BMWFJ) is responsible for the accreditation and supervision. Each OEKD certificate must be approved by an authorised signatory. OEKD certificates are issued for measuring instruments, which require a particularly high degree of reliability (e.g. works standards) or where measurements need to be traceable. TRACEABILITY OF MEASURING EQUIPMENT AND CALIBRATION The term traceability describes a process through which a measurement taken by a measuring instrument can be compared, in one or more steps, with a national standard for the physical value. These steps must form an uninterrupted chain of calibrations. In each step, a measuring instrument is compared with a standard whose measurement features themselves have been determined by comparison with a higher ranking standard. This process creates a calibration hierarchy or a hierarchy of the testing equipment. The bodies performing the comparisons within the chain must also have their technical expertise verified, e.g. through accreditation by a calibration authority. Calibrations performed by other bodies not accredited as calibration authorities are not considered traceable in line with EN ISO 9001 or EN ISO/IEC 17025 (even if they hold certification in accordance with this standard), as in this case, the body s technical expertise is not proven. MEASUREMENT UNCERTAINTY The measurement uncertainty is a feature of an accredited procedure. It describes to what extent a measurement can be traced to national standards and ultimately to International System of Units (SI units). Usually, an extended measuring uncertainty is specified, which is calculated from the standard uncertainty multiplied with the extension factor k=2. Each measuring value is associated with a (measurement) uncertainty. In the calibration hierarchy, testing equipment on a higher level has a lower measuring uncertainty that that on a lower level. Accreditation in line with EN ISO/IEC 17025 requires that measurement uncertainties are calculated according to EA-4/02 Guide to Expression of the Uncertainty of Measurement in Calibration, GUM. CALIBRATION TO THE ISO STANDARD ISO calibrations are comparative measurements taken with E+E reference instruments or systems, which are traceable to international standards with known measuring uncertainties. Comparisons take place based on internal procedures, which meet the requirements of ISO 9000 and ISO TS16949. This measurement provides a low-priced verification of the calibration-status of an instrument utilizing high-quality measuring equipment. It verifies the function of an instrument, specifying the measurement error. In specific cases requirements in accordance with the following standards can be covered: - ISO/QS 9000 - ISO10012-1 - GMP - CFR - VDA ISO TS 16949

CALIBRATION PROCEDURE Upon receipt of the measuring equipment an initial calibration is carried out in accordance with customer s specifications. The measured values are documented on a certificate. If requested, the measuring results will be compared with the specified tolerances of the measuring equipment as part of the initial calibration. If the recorded values for the measuring equipment fall outside the permissible tolerances, the customer may use the information to validate the results of previous quality tests and eventually initiate appropriate corrective action. At the request of the customer, a quotation will be issued for the cost of repair, respectively the adjustments. If E+E is not able to repair the equipment, it will be either returned to the customer or shipped directly to the manufacturer. Once the equipment has been repaired and adjusted, the measuring values will be documented during the second calibration routine. Separate certificates are issued for the first and second calibration confirming the measured values as received and as delivered. DELIVERY TIMES The E+E calibration lab ensures the shortest processing times. The customer is informed of the scheduled delivery date within 24 hours by means of an order acknowledgment. COLLECTION AND DELIVERY SERVICE Save yourself effort, time and money by taking advantage of our collection and delivery service. ISO calibration in E+E s standard calibration range: 4 working days after delivery for issue of a certificate OEKD calibration in E+E s standard calibration range: 5 working days after delivery for issue of a certificate.

Scope of Accreditation Range I is the E+E standard measurement range: 23 C ±3 C (73.4 F ±5.4 F), 15...95 % RH und 0 % RH [% RH] [ C ( F)] HUMIDITY Measurement under extreme climatic conditions is one of E+E Elektronik s specialities. The E+E OEKD Laboratory offers relative humidity calibrations in the temperature range from -70 to 200 C. Ranges II, III, IV and V define extended calibration ranges with different delivery times and prices. A complex two-pressure/two-temperature generator combined with a stable/homogenous temperature cabinet provides highest accuracy for relative humidity. CALIBRATION RANGE Calibration Calibration object Measuring condition Measuring range Measurement uncertainty OEKD Hygrometer for the measurement of humidity Gas fl ow max. 5 l/min; air pressure max. 1 MPa; Temperature range -40 to 180 C 1) ; Temperature 0 C Temperature > 0 C 0 to 98 % relative Humidity 0,2+0,008.mv % 0,1+0,004.mv % Humidity generator (e.g. Humor 20) Temperature range 25 C ± 3 C 10 to 95 % HR 25 C ± 3 C 0,15+0,005.mv% 0,08 K ISO Hygrometer 0 to 80 C 15 to 95 % < 2 % RH 1) On request, certificates are possible in the extended measuring range -70 to 200 C (-94 to 392 F), in the Designated laboratory at the highest accuracy. Other humidity measurment parameters on request (d v, r, w v, etc.) ORDER CODE Calibration Humidity [%] [A] Humidity generators [G] oder Hygrometer [H] OEKD- or ISO- Number of humidity calibration points 1-9 Number of calibration temperature 1-9 Temperature calibration points [ C] quote on the certificate yes / no B / - Number of temperature calibration points 1-9 Text field specification: Indicate values of calibration points (e.g.: 20/50/80 %) Desired temperatures (e.g.: 25/45/80 C) Order Example: OEKD-AH32B2 Text field: 20/50/80 %; at 25 C and 45 C Explanation: [A] Humidity calibration of a [H] - Hygrometer with [3] - 3 Humidity points at 20/50/80 % [2] - 2 Iterations (at 25 and 45 C) [B2] - 2 T-Calibration points shown on the certificate Order Example: ISO-AH31 Text field: 20/50/80 %; at 50 C Explanation: [A] Humidity calibration of a [H] - Hygrometer with [3] - 3 Humidity points at 20/50/80 % [1] - 1 Iteration (at 50 C) A G or H x x Order Example: OEKD-AG31 Text field: 20/50/80 %; at 25 C Explanation: [A] Humidity calibration of a [G] - Humidity generator with [3] - 3 Humidity points at 20/50/80 % [1] - 1 Iteration (at 25 C)

DEW POINT The dew point calibration system offers an impressive calibration range from -80 to 95 C dew point. Small measurement uncertainties provide the basis for precise calibration of transfer standards, such as dew point mirrors or dew point transmitters from any manufacturer. CALIBRATION RANGE Calibration Calibration object Measuring condition Measuring range Measurement uncertainty OEKD Chilled mirror hygrometer (Dew point mirror) Dew point hygrometer (Dew point transmitter) Comparison measurement with the primary generator Medium temperature: 23 C ± 3 C 1) Pressure: 1000 mbar ± 80 mbar 2) Comparison measurement with Chilled mirror hygrometer Medium temperature: 23 C ± 3 C 1) Pressure: 1000 mbar ± 80 mbar 2) -80 to 95 C -80 to -60 C -60 to -25 C -25 to 70 C 70 to 95 C -60 to 90 C 3) -60 to -25 C 3) -25 to 70 C 70 to 95 C 0,05-(60+mv).0,01 K 0,050 K 0,035 K 0,045 K 0,090 K 0,055 K 0,065 K ISO Dew point hygrometer (Dew point transmitter) Comparison measurement Medium temperature: 23 C ± 3 C 1) other temperatures on request 2) Dew point calibration at pressure up to 10 bar on request 3) down to -80 C Td on request ORDER CODE -60 to 70 C > 0,2 K Calibration Dew point temperature Td [ C] [C] or Frost point temperature Tf [ C] [D] Calibration object: Dew point monitor [S] or Dew point transmitter [T] OEKD- or ISO- Number of Dew point calibration points 1-9 Text field specification: Indicate values of calibration points (z.b.: -30/-10/15 CTd) Order Example: OEKD-CS3 Text field: -30/-10/15 CTd Explanation: [C] Dew point calibration of a [S] - Dew point mirror hygrometer [3] - 3 Dew Points at -30/-10/15 CTd Order Example: ISO-CT2 Text field: -40/70 CTd Explanation: [C] Dew point calibration of a [T] - Dew point transmitter [2] - 2 Dew points at -40/70 CTd C or D S or T x

AIR VELOCITY Two wind tunnels are available to calibrate the air speed: One free-stream wind tunnel up to 40m/s with integrated temperature control up to 80 C and one special wind tunnel for the low-flow range between 0.04 and 2 m/s. In combination with a laser Doppler anemometer, high reproducibility of results can be achieved. CALIBRATION RANGE Calibration Calibration object Measuring condition Measuring range Measurement uncertainty OEKD Measuring instruments for recording air velocity (hot-wire anemomenter, vane anemometer, pitot-static tubes, comfort level probe) 23 C ± 3 C 0,04 to 2 m/s (0,004 + 0,47% f.mv) m/s 5 to 80 C 0,3 to 40 m/s (0,004 + 0,47% f.mv) m/s ISO ORDER CODE Measuring instruments for recording air velocity 23 C ± 5 C 0,3 to 40 m/s < 1,0 % f.mv m/s Calibration Air velocity [e.g.: m/s] [N] OEKD- or ISO- Number of Air velocity calibration points 1-9 Number of calibration temperature 1-9 Text field specification: Values of calibration points and unit (e.g.: 5/10/15/20 m/s) Desiered calibration temperature (z.b.: 25/45/80 C) Order Example: ISO-N41 Text field: 5/10/20/30 m/s; at 23 C Explanation: [N] Air velocity calibration with [4] - 4 Calibration points at 5/10/20/30m/s [1] - 1 Iteration (at 23 C) Order Example: OEKD-N32 Text field: 10/20/30 m/s; at 23 C and 50 C Explanation: [N] Air velocity calibration with [3] - 3 Calibration points at 10/20/30m/s [2] - 2 Iterations (at 23 C and 50 C) N x x

MASS FLOW The E+E OEKD Laboratory for air flow is unique in Europe and offers mass flow and volumetric flow calibrations for standard conditions in the range from 0.6 to 2300 m³/h. To allow calibration as close as possible to the real application, the operating pressure in the system can be set between 1 and 10 bar. CALIBRATION RANGE Calibration Calibration object Measuring condition Measuring range Measurement uncertainty OEKD Mass fl ow sensor Flow transmitter 0,1 to 1 MPa = 1 to 10 bar 23 C ± 3 C Flow rate at standard conditions Q 0 = 0,6 to 2300 m³/h refer to 0 C/1013 mbar 0,003 m³/h + 0,9% f.mv ORDER CODE Calibration Standard flow V 0 [z.b.: m³/h] [R] or Mass flow m [e.g.: kg/h] [S] Number of Flow calibration points 1-9 Number of calibration pressures 1-9 Text field specification: Values of calibration points and unit (e.g.: 5/80/150 m³/h) Desired pressures (e.g.: 1/7/10 bar) Indicated pipe diameter (DN 15/20/25/30/40/50/65) OEKD- R or S x x x Order Example: OEKD-R52 Text field: 5/50/80/130/150 m³/h; 3/7 bar; DN 65 Explanation: [R] Standard flow calibration with [5] - 5 Calibration points at 5/50/80/130/150 m³/h [2] - 2 Iterations (at 3 and 7 bar) Pipe diameter: DN65 Order Example: OEKD-R51 Text field: 5/50/80/130/150 m³/h; 8bar; DN 40 Explanation: [R] Standard flow calibration with [5] - 5 Calibration points at 5/50/80/130/150 m³/h [1] - 1 Iteration (at 8 bar) Pipe diameter: DN40

TEMPERATURE Depending on the requirements, calibration in air and calibration in the block calibrator are offered. With air as the medium, temperature calibration is limited to the range between -40 to 180 C. For simple calibration in the block calibrator, the laboratory is certified for the temperature range -45 to 425 C. The essential difference between air and block calibration is to be seen in how the heat generated in the test piece by the measurement medium is taken into account. CALIBRATION RANGE Calibration Calibration object Measuring condition Measuring range Measurement uncertainty OEKD Thermometer for temperature Immersion- and cut-in probe comparison measurment in temperature-controlled measuring chamber comparison measurment in dry block calibrator -40 to 180 C* 0,05 K -45 to 425 C < 23 C: 0,50 * [t-23] + 28 mk 23 C: 0,22 * [t-23] + 28 mk ISO Thermometer for temperaturer Immersion- and cut-in probe comparison measurment in temperature-controlled measuring chamber comparison measurment in dry block calibrator -40 to 180 C < 0,2 K -45 to 425 C < 0,2 K * On request, certificates are possible in the extended measuring range -70 to 200 C (-94 to 392 F), in the Designated laboratory at the highest accuracy. ORDER CODE Calibration Temperature [e.g.: C] [B] Temperature calibration Air [L] or Temperature calibration Contact [K] in the dry block calibrator OEKD- or ISO- Number of Calibration temperature 1-9 Text field specification: Values of calibration points (e.g.: -10/15 C) Order Example: OEKD-BK3 Text field: -45/100/425 C Explanation: [B] Temperature calibration [K] - in the dry block calibrator [3] - 3 T-Calibration points at -45/100/425 C Order Example: OEKD-BL2 Text field: -10/15 C Explanation: [B] Temperature calibration [L] - in Air [3] - 2 T-Calibration points at -10 und 15 C B L or K x

CO 2 CO 2 is becoming a more and more important measurement variable for the effective utilisation of resources and also a reference variable for many processes. Long experience in the CO 2 sensor range is a prerequisite for accurate calibration. E+E ISO calibrations in the measurement range from 0 to 10.000 ppm provide a clear insight into the accuracy of your CO 2 transmitter. CALIBRATION RANGE Calibration Calibration object Measuring condition Measuring condition Measurement uncertainty ISO CO 2 -probe 1013 ± 50 mbar 23 C ± 3 C 0; 1000; 4000; 7000 ppm* 2 % f.mv [ppm] * Other Measuring points in the range of 0-10,000 ppm on request. ORDER CODE Calibration CO 2 [ppm] [U] Number of CO 2 -Calibration points 1-9 Text field specification: Values of calibration points (e.g.: 7000 ppm) Order Example: ISO-U1 Text field: 7000 ppm Explanation: [U] CO 2 -Calibration with [1] - 1 Calibration point at 7000 ppm Order Example: ISO-U3 Text field: 0/4000/7000 ppm Explanation: [U] CO 2 -Calibration with [3] - 3 Calibration points at 0/4000/7000 ppm ISO- U x

Advantages - Traceability to national andinternational standards - Calibration of on-site equipment and measuring instruments possible - Independent supervision of test equipment by an accredited company - No malfunction of test equipment - Quick turn-around times - No transportation risks On-site calibration On-site calibration may be required for certain process and quality-relevant measuring points. For this purpose, E+E offers a manufacturer-independent calibrationservice for the physical quantities humidity, temperature and dew point. The on-site service covers the calibration of stationary and portable instrumentation as well as climate chambers with specific customer requirements. CALIBRATION RANGE FOR HUMIDITY Calibration Calibration object Measuring condition Measuring range Measurement uncertainty OEKD Hygrometers for measurement of humidity e.g.: transmitters, data loggers, hand helds,... comparison measurement with humidity generator Special on-site calibration on request 10 to 95 % RH at ambient temperature 25 C ±10 C 0,5+0,006.mv % CALIBRATION RANGE FOR TEMPERATURE Calibration Calibration object Measuring condition Measuring range Measurement uncertainty OEKD Thermometer for temperature Immersion- and cut-in probe comparison measurement in climate control systems comparison measurement in dry block calibrators -25 to 100 C 0,05 K -45 to 425 C < 23 C: 0,50 * [t-23] + 28 mk 23 C: 0,22 * [t-23] + 28 mk T ORDER CODE relative Humidity Temperature Calibration OEKD- OEKD- On-site calibration V V Measurand A B Hygrometer H - Temperature calibration Air [L] or Temperature calibration Contact [K] in a dry block calibrator - L or K Calibration points 1-9 1-9

INFORMATION ON CALIBRATION CERTIFICATES Calibrations performed by the National Metrological Institute The National Metrological Institute (NMI) or its Designated Institutes (DI) represent the top level of the traceability chain for calibrations. They maintain the highest national measurement standards and ensure that the measurements correspond to the international system of units SI. NMIs and DIs participate in international comparative measurements with other NMIs and cooperate in technical committees to ensure that they are the top reference for measurement variables. The measurement uncertainties of NMIs or DIs do not (or hardly) exceed those of accredited top calibration laboratories but can also be provided for special calibration tasks as part of the internationally agreed calibration options (CMC data) published in the BIPM (Bureau International des Poids et Mesures). Calibration carried out by NMIs and DIs are very extensive, do not address the frequent calibration tasks in industrial measurement, and are therefore only of interest in international comparisons among accredited calibration laboratories. E+E Elektronik, as designated Institute of the Republic of Austria (e.g. for relative humidity), is authorised to carry out calibrations as Designated Institute of the Austrian NMI BEV. Calibration by accredited calibration laboratories The task of accredited calibration centres is to achieve traceability of measurements and calibrations in industrial metrology to the highest national or international standards. Calibration certifi cates from accredited calibration laboratories in the Austrian Calibration Service OEKD are recognised public certifi cates, which satisfy the legislative requirements for traceability of calibrations to national and international standards for all relevant regulations and management systems. Accredited laboratories in the OEKD use validated calibration procedures, the technical details of which have been tested, approved and monitored by the State Accreditation Authority. The contents and stipulated measurement uncertainties in the OEKD calibration certifi cates therefore satisfy all requirements of ISO 17025 and the further legislative rulings of the Austrian Calibration Service; this is not always established according to identical strict regulations even in renowned industrial countries. For this reason, OEKD calibration certifi cates are highly acknowledged internationally. OEKD calibration certifi cates are used to verify the traceability of calibrations for industrial metrology and to provide legal certifi cation for the assured product properties of the products tested. E+E Elektronik is an OEKD calibration laboratory that is authorised to issue such calibration certificates for a number of accredited measurement variables and has been offering this service successfully for several years. Calibration by calibration service providers Expert service providers often provide high-grade technical calibrations for almost all industrial measurement variables and a variety of marketing names (for example, ISO Calibration, Industry Service Calibration, etc.). Although these calibrations are performed to a high technical standard, in some cases even using the same equipment and procedures as accredited calibrations, they do not satisfy stringent legal requirements for traceability, since the procedures and measurement uncertainties are not verifi ed in external tests (e.g. verifi ed in the course of accreditation) but are determined and specifi ed only under the responsibility of the calibration service provider. Even if such calibration certifi cates contain detailed specifi cations for measurement uncertainties and are designed very similar to accredited calibration certifi cates, they are no more than a good expertise for the measured product features. They do not provide proper verifi cation of the traceability of calibrations to national and international standards. Calibrations of this kind can, of course, be offered at a much lower price than accredited calibrations. It is interesting to note that such calibration certifi cates are still being accepted as verifi cation of traceability for calibrations in some fi elds and industries It is up to the customer to decide which requirements apply to his calibrations and which calibration certificate is appropriate and/or required. E+E Elektronik also offers their customers consolidated consultation services in addition to the provision of such calibration certifi cates. Factory calibrations Factory calibrations are not legally valid documents for traceability verification; however, they do contain the manufacturer s confi r- mation that the products have been manufactured and inspected in compliance with the applicable regulations using the appropriate materials and internal monitoring procedures. These calibration certifi cates are issued on the basis of standards like DIN EN 10204, for example, and represent documented fi nal inspections of the producer. Such certifi cates can also be offered at low cost for products, or are included as standard.

HUMIDITY DEW POINT AIR VELOCITY MASS FLOW TEMPERATURE CO 2

E+E Elektronik Head office Head office: Subsidiaries: E+E Elektronik Ges.m.b.H. Langwiesen 7 A-4209 Engerwitzdorf Austria Tel: +43 7235 605 0 Fax: +43 7235 605 8 info@epluse.com / www.epluse.com E+E Elektronik China / Beijing Tel: +86 10 8499 2361 info@epluse.cn / www.epluse.cn E+E Elektronik Germany Tel: +49 6172 13881 0 info@epluse.de / www.epluse.de E+E Elektronik Italy Tel: +39 0331 177 31 02 info@epluse.it / www.epluse.it E+E Elektronik USA Tel: +1 781 828 6200 office@epluse.com / www.epluse.com E+E Elektronik China / Shanghai Tel: +86 21 61176129; +86 21 61176130 info@epluse.cn / www.epluse.cn E+E Elektronik France Tél: +33 4 74 72 35 82 info@epluse.fr / www.epluse.fr E+E Elektronik Korea Tel: +82 31 732 6050 info@epluse.co.kr / www.epluse.co.kr Version 1.0 / Modification rights reserved Artikelnummer 485064 INFORMATION FAX +43 7235 605 8 / info@epluse.com calibration request device / probe manufacturer physical quantity calibration points ISO OEKD BEV lab on-site I need furhter information, please contect me Title, First name Last name Company Department Street Zip Code/Town Country E-Mail Telephone www.epluse.com