SERVICE MANUAL MODEL BA020ANM-S1 BREATHING AIR PANEL

Similar documents
SERVICE MANUAL MODEL BA020AMST BREATHING AIR PANEL

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL

SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

MODEL RP050BMST RESPIRATORY PROTECTOR MANUAL

MODEL RP050BMST-S1 RESPIRATORY PROTECTOR MANUAL

MODEL RP200C(_)-S1 RESPIRATORY PROTECTOR MANUAL

INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

ADVANCED AIRLINE FILTER INSTRUCTION MANUAL

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

INSTRUCTION MANUAL & PARTS

INTRODUCTION... 3 II II II II II II II II II II II II II I 4-5 ASSEMBLY... 6,7,8 II II II II II II II... 9

BREATHING AIR PURIFIER

3M TM Versaflo TM AP-600 Series Air Filtration Panels For use with 3M TM Versaflo TM Supplied Air Respirator Systems. Work. in a World of.

PRODUCT OPERATING MANUAL

Important: Keep these instructions for reference.

AIRLINE-SERIES HELMET AIR FILTER

PERSONAL AIR BREATHING UNIT

Technical Information

A. Evaluation of the written program

OPERATION MANUAL NTF-60 Plus

Tsunami Breathable Air System

OPERATION MANUAL NTF-15

Air Quality Test Kits Models: LP/HP-A4K and LP/HP-A445K

B-Series. breathing air systems flow capacity: scfm

Operating Manual. Model BAC-30RT30/BAC-30DC

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Advantage 4000 Abrasi-Blast Respirator

TECHNICAL INFORMATION

exceeds global breathing air quality standards B 1 breathing air systems flow capacity: scfm flow capacity: scfm ( Nm 3 /hr)

MODEL CALIBRATION GAS DELIVERY SYSTEM

HPIC D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS

Installation, Operation, and Maintenance Manual Parker Balston Model N2-04 Nitrogen Generator

List of Contents vma. Compressed Air Conditioning 2. System description 2. Individual Units Pre-Filters 3. Combinations 6

RAM 9025-XP Operation Manual

BREATHE SAFELY: The Proper Use of Respiratory Protection

ADP3CA Free-Air Pump User Manual

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

Texas Department of Insurance. Respiratory Protection. Provided by. Workers Health & Safety HS01-027B (1-06)

Interface Devices, Inc. Hydraulic Mini Mule

A Pocket Guide to Air-Line Systems

The Following information is based on material prepared by the American Lung Association

Yoke Block Instruction Manual

GREIG FILTERS, INC. OPERATION MANUAL

Oxygen Usage Best Practice Guide

photo coming soon Product Family Respiratory Replacement Parts Canada (English) Page 1 of 17 Product Numbers & Ordering Information

TECHNICAL INFORMATION

CPR MEDICAL DEVICES INC. OPERATING MANUAL FOR RESUSCITATOR

PremAire INSTRUCTIONS FOR DUAL-SUPPLY MODE OF OPERATION

AIR INLINE METAL SHEAR

Instruction Manual Updated 7/26/2011 Ver. 2.2

600 o F High Temperature Aging Cell Instruction Manual

Product Information News

Yoke Block Instruction Manual

Operating Manual. Appa. Models LP/HP-A4K & LP/HP-A445K Air Quality Test Kits Manual No. AIRTST01 (Rev 7 October 2008)

Protective device that covers the nose and mouth or the entire face or head to guard the wearer against hazardous atmospheres

Nitrogen Supply System

Tri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Organic Vapor/P95, Disposable

6A.004 SCBA MAINTENANCE. Policy Number. Page 1 of 5 SCOPE

PRESSURISED PAINT CONTAINER

A Pocket Guide to Air-Line Systems. Visit: Or for Sales & Service.

MF2M Monnier Miniature Compressed Air Filter

CPR MEDICAL DEVICES INC. OPERATING MANUAL

E3628 THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING. Leader s Guide ERI Safety Videos EMPLOYEE TRAINING

photo coming soon Product Family Respiratory Replacement Parts Corporate - English Page 1 of 23 Product Numbers & Ordering Information

Respiratory Protection for Producers

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

TECHNICAL DATA. Page 1 of 12

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

East Brunswick Fire District #1

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Breathing Air Purifiers. Comply with European Pharmacopoeia and International Breathing Air Standards

ADP20 Free-Air P u m p

Personal Protective Equipment 29 CFR 1926

IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Respiratory Protective Equipment

Geotech 1.66 Auto-Reclaimer

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use.

Geotech 1.66 Auto-Reclaimer Installation and Operation

Respiratory Protection

Nitrogen Advantage. Better Tire Pressure Retention. Improved Fuel Economy. Extended Tread Life. Elimination of Oxidation. Reduction in Tire Failures

Respirator Selection Guide

University of Dayton Respiratory Protection Program 29 CFR

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

CS Controlled Dissolved Gas assembly with optional CS Air Aspirator assembly. Installation and Operation information

Niltox Breathing Air Purifier Range

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

Respiratory Protection Self-Inspection Checklist

FACILITIES MANAGEMENT OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY Respiratory Protection Policy 03/20/15 Last Revision

Respiratory Protection

Protocol Switchover Station

2K 600mL Dispense Guns with Built-In Retainers

Transcription:

SERVICE MANUAL MODEL BA020ANM-S1 BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 6/08

2 GENERAL OPERATION MANUAL WARNING: The MST Breathing Air Panel Model BA020ANM-S1: 1) WILL NOT remove Carbon Monoxide. 2) SHOULD NOT be used when the air entering the filtering system is oxygen deficient. The MST Breathing Air Panel will not increase the oxygen content of the air. 3) SHOULD NOT be used in an Immediately Dangerous to Life and Health Atmosphere (IDLH) unless it is used in conjunction with a Back-Up Escape system or a supplied air Self-Contained Breathing Apparatus (SCBA), where applicable. 4) SHOULD NOT have air inlet pressure greater than 150 PSIG static (10.4bar). Personal injury could result. 5) SHOULD NOT have air outlet pressure that exceeds Manufacturers' Respirator/Hose Assembly pressure requirements. Personal injury could result. The MST Breathing Air Panel is a Three Stage Filtration System designed to remove or reduce select contaminates found in compressed air lines while monitoring for carbon monoxide through the MST Monitor. The Breathing Air Panel can be connected directly to shop air from a standard compressed air source to help provide breathing quality air to face masks, helmets, hoods and other supplied air breathing apparatus.

3 GENERAL FILTER SYSTEM DESCRIPTION (Refer to Figure No.1) Air entering the MST Breathing Air Panel at the inlet (A) is usually contaminated with oil, water, dirt, rust, scale and gaseous Hydrocarbons. As the air passes through the First Stage (B) of the MST Prefilter, particulate matter is trapped and retained down to 0.3 microns. The air then enters the Second Stage (C) of the Prefilter which coalesces liquid contaminates down to 0.75 microns with an efficiency rating of 99.97% (meets Underwriters Laboratories Specification UL 586 for High Efficiency, Particulate, Air Filter Units). The liquid contaminates are trapped in the lower chamber of the prefilter and expelled out through the Automatic Float Drain. The Third Stage (D) contains a bed of odor absorbing activated charcoal which collects various gaseous Hydrocarbons (such as oil fumes, benzene, etc.). The air is then passed through the Air Pressure Regulator (E), which is used to adjust the air pressure going to the respirator. FIGURE NO.1

4 GENERAL INSTRUCTIONS The MST BA020ANM-S1 Breathing Air Panel, a compressed air purifier, when used in accordance with the following instructions, will remove or reduce selected contaminants from compressed air lines. WARNING: The MST Breathing Air Panel BA020ANM-S1 should not be used when the air entering the filter is oxygen deficient (air with a low oxygen content). The MST Breathing Air Panel will not increase the oxygen content of oxygen deficient air. MST, Inc. strongly recommends that a complete safety program be initiated to ensure that the respiratory air is in compliance with all OSHA standards and other applicable laws regulating the use of supplied air respiratory systems. MST, Inc. recommends that the air quality be tested upon installation and periodically re-tested to ensure that the minimum requirements for breathing air are maintained. WARNING: The MST Breathing Air Panel BA020ANM-S1 will not remove Carbon Monoxide. This system is to be used only by trained qualified personnel in accordance with a respirator program as outlined in OSHA Regulation 29 CFR 1910.134(b). MST, Inc. will not assume any liability for accidents or personal injury resulting from the improper use of this equipment. The air supply entering The MST Breathing Air Panel must meet two (2) criteria to ensure maximum efficiency of the MST filter system: 1) Temperature range should be between 68-150 o F (20-65 o C) 2) Liquid size range should be between 2-8 microns. Conditioning equipment may be necessary, prior to the filter, to achieve this temperature range and bulk liquid removal. WARNING: Maximum pressure supplied to this unit IS NOT to exceed 150 PSIG. Personal injury could result.

5 The Regulator 80112 is used to adjust the air pressure supplied to the operator(s) to maintain the correct air exchange inside the mask. Consult instructions on your particular breathing mask or hood for pressure requirements per NIOSH. The Breathing Air Panel Model BA020ANM-S1 is supplied with 3/8" FPT at the inlet and two 1/4" Industrial Interchange Quick-Disconnects at outlet. WARNING: DO NOT Exceed mask and hose assembly manufacturer's requirements for outlet pressure. Personal injury could result. The filter cartridges used in the Breathing Air Panel Model BA020ANM-S1 have an average life expectancy of (3) three months, (depending on the quality of the air in your compressed air lines) under normal conditions. MST, Inc. recommends changing the two (2) filter cartridges after three months of use unless conditions warrant more or less frequent replacement.

6 SERVICE INSTRUCTIONS (Refer to Figure No.2) WARNING: Always turn off air supply and bleed air pressure before disassembling unit or SERIOUS INJURY COULD RESULT. MST, Inc. recommends replacing the two (2) filter cartridges after three (3) months of use unless conditions warrant more or less frequent replacement. To refill or replace the filter cartridge thebreathing Air Panel Model BA020ANM-S1, follow these steps: 1. PREFILTER FIRST/SECOND DUAL STAGE ELEMENT REPLACEMENT A) Unscrew Prefilter bowl Assembly 1. Clean in mild soap and water and blow dry with low pressure air. B) Remove Dual Stage Element 2 by unscrewing End Cap Retaining Nut 3. C) Inspect the Prefilter Manifold 4 for dirt/contaminates and clean as required. Inspect "O"- Ring 5 for cuts, etc. and replace if required. D) Install new Dual Stage Element and tighten End Cap Retaining Nut. Be sure Element is seated squarely on Manifold boss and End Cap. E) Apply light film of petroleum jell on Bowl's beveled edge to provide good seal between Bowl and "O"-Ring. HAND TIGHTEN ONLY. F) Dispose of used Dual Stage Element according to local, state and federal regulations. 2. THIRD STAGE ADSORBER CARTRIDGE REPLACEMENT The Absorber Cartridge change is required when any odor is detected by operator, and/or if any liquids are expelled out of Third Stage manual drain. A) Replace the Absorber Cartridge (6) using the above Prefilter replacement instructions. B) Dispose of used cartridge, according to local, stage and federal regulations.

3. FINAL CHECK AND CALIBRATION A) Pressurize system and check for leaks. B) Flush system with compressed air for five (5) minutes.. 7 FIGURE NO.2

8 RECORD KEEPING Record all periodical air quality checks, monitor calibration dates, filter cartridge change intervals and any other service performed on the MST Breathing Air Panel. MST INC. SHALL NOT BE LIABLE FOR ANY INJURY, LOSS OR DAMAGE, (DIRECT OR CONSEQUENTIAL), ARISING OUT OF THE USE OF OR THE INABILITY TO USE THIS PRODUCT, BEYOND THE REPLACEMENT Of DEFECTIVE MATERIALS OR WORKMANSHIP. USER OF SUPPLIED AIR RESPIRATORS SHOULD EVALUATE THEIR OWN PARTICULAR APPLICATION AND PERFORM THEIR OWN TESTS FOR AIR QUALITY TO DETERMINE THE SUITABILITY FOR USE OF THIS PRODUCT. For further information, or questions about service or maintenance care of this unit, contact your local distributor or MST, Inc. at (800) 542-6646.

9 MST, INC. SERVICE RECORD BREATHING AIR PANEL MODEL BA020ANM-S1 DATE OF SERVICE SERVICE PERFORMED

10 SPECIFICATIONS BREATHING AIR PANEL MODEL BA020ANM-S1 INLET PRESSURE (MAX.) RATED AIR FLOW (MAX.) OPERATING PRESSURE OUTLET PRESSURE RANGE 150 PSIG STATIC (10.4 BAR) 20 SCFM (9.4L/s) 100 PSIG DYNAMIC (6.9 BAR) 0-125 PSIG (0-8.6 BAR) OPERATING TEMP. RANGE 68-150 O F (20-65 O C) OUTSIDE DIMENSIONS 16"L X 16"W X 5.5"D (406 mm X 406 mm X 140 mm) WEIGHT REPLACEMENT FILTER SET 10 LBS. (4.5 Kg) FB020

11 BREATHING AIR PANEL MODEL BA020ANM-S1 PARTS 1 80142, (1), 3/8" BALL VALVE 9 80014, (1), 1/4" x 150 PRV 2 S608-005, (4), HEX NIPPLE -3/8" 10 S623-003, (3), 3/8" x 90 ST. ELBOW 3 80126, (1), PREFILTER-20 SCFM 11 S687-003, (1), 3/8" FLUSH PLUG 4 80051, (1), TUBE LOCKING COLLAR 12 80112, (1), REGULATOR 5 S710-005, (1), DRAIN TUBE 13 80528, (1) PRESSURE GAUGE, 0-160 6 80161, (1) ABSORBER FILTER 14 S631-003, (1), 3/8" ST. TEE 7 80098, (1), 3/8" CROSS 15 80022, (2) 1/4"II x 3/8" MPT QUICK-DIS 8 S638-007, (1) 3/8" x 1/4" HEX BUSH 16 80426, (1), 16" x 16" x 1/2" BOARD