REF Description Picture Technical data Page

Similar documents
Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

SOLENOID VALVES AND PNEUMATIC VALVES

Mass Flow Meter (MFM) for Gases

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

SPCH/ Blowing block

[Instruments for vacuum measurement, checking and adjustment] 3

Mass Flow Controller (MFC) for Gases

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)

Mass Flow Controller (MFC) for Gases

2/ Port G1/4

compact ejector, Series ECM with Adjustable release pulse with silencer With filter vacuum switch: electronic 2 x PNP

MANUAL KPS Pressure Control Valve

Mass Flow Meter (MFM) for gases

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

Digital electro-pneumatic regulators Series ER100

The affordable consumption counter for compressed air and gases R 3 /4 (DN 20)

Visualize Nitrogen Gas Consumption

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

better measurement Simply a question of

Mass Flow Controller (MFC) for Gases

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

Mass Flow Controller (MFC) for Gases

Pneumatic turret stop with 6, 8 and 12 stop positions for automation

MoveRoll Conveyor Operating and Maintenance Manual

Mass Flow Controller (MFC) for Gases

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Introduction to Pneumatics

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

VALVES ISO 5599/1, SERIES IPV-ISV

Pneumatic high-pressure controller Model CPC7000

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

Proportional pressure regulators VPPE

Inverse Proportional Pressure-Relief Cart., Size 2 4

C-Flow Coriolis Mass Flow Meters

pneumatic power clamps

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2" Centered (Default)

Pneumatic spool valve islands

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm

EPR High Precision 3000 psi Electronic Pressure Controller Accurate to 0.25% of full scale

Inverse Proportional Pressure-Relief Cart., Size 2 4

SonoMeter 30 Energy Meters

Inverse Proportional Pressure-Relief Cartridge, Size 10

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

CALEFFI. Ball zone valves. series /03 GB

Type 4708 Supply Pressure Regulator

Proportional Throttle Cartridges, Size 16

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

Inverse Prop. Pressure-Relief Cart., Size 2 4

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Model PDT Dewpoint Transmitter

Mass Flow Controller (MFC) for Gases

Digital dead-weight tester Model CPD8500

CORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES

WHITEPAPER. The flowplus 16 Pressure Sensor. Physical Principles and Function

Digital deadweight tester Model CPD8500

PZN-plus. Application example. Pneumatic 3-Finger Centric Gripper Universal Gripper. Sizes Gripping force 580 N..

Gas Pressure Switch for DMV safety shutoff valves

DATA PD , DR3... Product PD Unloader Valves. Function. Technical Features DR3510 DR3575

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

JUMO dtrans p30 Pressure Transmitter

Precision Mass Flow Meters / Controllers for Liquids and Gases

2/2-Way Solenoid Control Valve

Bypass Mass Flow Controller (MFC) for gases

Test and Adjustment Instructions Compressed Air Processing System Air Processing Unit (APU)

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

FEPA PNEUMATICALLY AND SOLENOID ACTUATED VALVES, ONE UNIT MOUNTED TYPE VPG

Type 4708 Supply Pressure Regulator

Pressure Calibrators. Series PC..., PM...

ATH 500 M. Pumping speed ATH 500 M. 3.1 Vacuum generation / Turbopumps / Magnetically levitated / ATH 500 M. Page 398 / Part 3.1

Application of EN ISO in electro-pneumatic control systems

Mass Flow Controller (MFC) for gases. Inline MFC for nominal flow rates from 25 I N. /min to I N

GA24 Technical Datasheet

G1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar

Gas Pressure Switch for DMV safety shutoff valves

LEA_EN_PZL Dynamometric Scale. Instruments and Systems for Geotechnical and Structural Monitoring

ATM.ECO - Analog Pressure Transmitter

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Pneumatic Outflow Control

Air service units series Y G1/4 to G1

MPRM1690 MPRM2590 MPRM3290

BULLETIN E485A. Standard Interface Poppet Valve Construction Customized Solutions Plug-and-Play Design.

ACTUATORS AND INSTRUMENTS

Pneumatic valve islands

Compact pressure switches for gas and air

OPTIBAR P 1010 C Technical Datasheet

Type 4708 Supply Pressure Regulator

Model 601CV. Mass Flow Controller. Product Features:

4/2 way Pneumatic Solenoid Valve

GRUNDFOS alldos product information. Vaccuperm 111 / 113. Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide

Design Features. General Description

Transcription:

Dosing equipment REF Description Picture Technical data Page D Piston dosage ECON 4, 6, 7, 0 VDC approx. 45W (40%ED/S) 50-00 g/0sec Tolerance ±0% Vmax to 60km/h Price **** Pmin: 6bar D4 P5 piston dosage Pneumatically activated totally enclosed Ca.0 Nl/min air consumption 00-800 g/0sec Tolerance ±0% 5 Vmax to 60km/h Price ** 4, 6, 7, 0 VDC approx. 60W ( 40%ED/S) D5 N45 piston dosage takting electrically 50-00 g/0sec 6 Tolerance ±0% Vmax to 400km/h Price **** D6 Z4 Cell wheel dosage with brushes motor D7 Z4 Cell wheel dosage with brushless motor 4 VDC approx. 50W ( 00%ED) 50-00 g/0sec Tolerance ±0% (±0%) Vmax to 400km/h Price **** 4 VDC approx. 50W ( 00%ED) 50-00 g/0sec Tolerance ±5% Vmax to 400km/h Price ***** 7 8

Technical data piston dosage ECON Magnet-activated piston dosage has been developed for precise batching of sand- and for the safe blocking D of the sand container. The functional principle was developed in a similar way to that of a piston-operated valve. It is activated by a hoist magnet. The sand amount can be adjusted via the hoist setting of the magnet accessible from the outside. The interruption of the sand flow is operated by a spring 4 Dosage housing Hoist magnet (can be rotated 4 x 90 ) 4 Adjusting screw modular structure: horizontal, perpendicular, rotating Operative voltage 4, 6, 7 und 0VDC * ± 0% Power approx. 40W (40% ED / S) Plug Valve plug design A with protective circuit DIN EN 750-80 (replaces DIN 4650) * quantity 50-00 g/0sec ± 0% infinitely adjustable during nominal voltage * 0,5 to 0bar (type. 0,5 bar by supply with small compressors and/or 6 bar over pressure control valves by central compressed air feed circuit ISO 857: Particle class: 7 (size <= 40µm/ concentration <= 0 mg/m ³) Air humidity class: (dew point -40 C/min. 5 K under the deepest IP66 to 60km/h EN 5055 (T) The version of equipment needs less maintenance. Only regular function controls are to be carried out. For main overhaul the equipment components are to be submitted to a complete examination. The changing intervals depend on the real conditions of service.

Technical data cylinder dosage P5 Pneumatically activated dosage piston has been developed for precise batching of sand and for the safe blocking of the sand container. The D4 P5 dosage was specially designed for an easy and quick integration in vehicles. This property is particularly important in the conversion of existing vehicles in order to make the sanding system compatible to the current standards (TSI, GMRT46, B0). The functional principle was developed in a similar way to that of a piston operated valve. It is activated by a pneumatic cylinder. The sand amount can be continuously adjusted via the hoist setting of the magnet accessible from the outside. The interruption of the sand flow takes places by the operation of a spring. All crucial components are totally enclosed against external influences (e.g. crushed stone flight). Dosage housing 4 Pneumatic cylinder 4 Adjusting screw quantity Adjustment range : 00g/0s 800 g/0s * st stage : 400g/0s ±00g/0s / nd stage : 650g/0s ±50g/0s According to BN 98 4 acc. to ISO 857-:00 Air consumption Weight Particle class: 7 (size <= 40µm/concentration <= 0 mg/m ³) Air humidity class: (dew point -40 C/min. 5 K under the deepest st stage = 6 bars (±0,5 bar) nd stage = 8 bars (±0,5 bar) approx. 0 Nl @6bar to 60km/h EN 5055 (T) -5 C +80 C,6kg The version of equipment needs less maintenance. Only regular function controls are to be carried out. For main overhaul the equipment components are to be submitted to a complete examination. The changing intervals depend on the real conditions of service.

Technical data piston dosage N45 Magnet-activated piston dosage has been developed for precise batching of sand- and for the safe blocking of the sand container. The functional principle was developed in a D5 similar way to that of a piston-operated valve. It is activated by a hoist magnet. The setting of the sand amount is about the relationship between ON-and OFF-time. The pulse signal is generated in the vehicle control or over a programmable time delay relay with semiconductor. The interruption of the sand flow takes place by the operation of a spring Dosage housing Hoist magnet modular developed: horizontal, perpendicular, rotating Operating voltage 4, 6, 7 and 0VDC * ± 0% Power approx. 60W (40% ED / S) time in/time out Connection/plug quantity >70ms / >60ms open cable end/ilme plug connector (or customized) 50-00 g/0sec ± 0% during nominal voltage * 0,5 to 0bar (type. 0,5 bar at supplies by small compressors and/or 6 bar over pressure control valves by central compressed air feed circuit ISO 857: Particle class: 7 (size <= 40µm/concentration <= 0 mg/m ³) Air humidity class: (dew point -40 C/min. 5 K under the deepest IP66 to 400km/h EN 5055 (T) The version of equipment needs less maintenance. Only regular function controls are to be carried out. For main overhaul the equipment components are to be submitted to a complete examination. The changing intervals depend on the real conditions of service.

Technical data cell wheel dosage Z4 Cell-wheel dosage has been developed to precisely batch the sand and safely block the sand container. The functional principle was developed in a similar way to that of a cellwheel lock. It is activated via a DC transmission motor. The sand amount is adjustable via D6 the RPM setting for the motor accessible from outside. The interruption of the sand flow takes place by shutting off the motor. Dosage housing Cells modular developed: horizontal, perpendicular, rotating Operating voltage 4VDC * ± 0% Power Connection/plug quantity approx. 50W (00% ED) open cable end/ilme plug connector (or customized) 50-00 g/0sec ± 0% with nominal voltage (±0% are only attainable with a stabilized electrical system, otherwise the tolerance is equal to the proportional voltage fluctuation) * 0,5 to 0bar (type. 0,5 bar by supply with small compressors and/or 6 bar over pressure control valves with central compressed air feed circuit ISO 857: Particle class: 7 (size <= 40µm/concentration <= 0 mg/m ³) Air humidity class: (dew point -40 C/min. 5 K under the deepest IP40 (only for the assembly inside the vehicle) To 400km/h EN 5055 (T) The version of equipment needs less maintenance. Only regular function controls are to be carried out. For main overhaul the equipment components are to be submitted to a complete examination. The changing intervals depend on the real conditions of service.

Technical data cell wheel dosage Z4 Cell-wheel dosage has been developed to precisely batch the sand and safely block the sand container. The functional D7 principle was developed in a similar way to that of a cell-wheel lock. It is activated via a brushless DC transmission motor. The sand amount is adjustable via the RPM setting for the motor accessible from outside. The sand quantity is directly proportional to the motor speed. The control happens either by stage over digital entries (binary up to 8 stages) or an analogue current (4-0mA) or tension interface (0-0VDC). The sand characteristic can be manipulated at will by analogical functioning up to 0 supporting places. The interruption of the sand flow takes place by shutting off the motor. Dosage housing Cell wheel modular developed: horizontal, perpendicular, rotating Operating voltage 4VDC * ± 0% Power Connection/plug approx. 50W (00% ED) Ilme plug connector (or customized) quantity 50-00 g/0sec ± 5% by nominal voltage * 0,5 to 0bar (type. 0,5 bar for supply by small compressors and/or 6 bar over pressure control valves by central compressed air feed circuit ISO 857: Particle class: 7 (size <= 40µm/concentration <= 0 mg/m ³) Air humidity class: (dew point -40 C/min. 5 K under the deepest z IP66 to 400km/h EN 5055 (T) The version of equipment needs less maintenance. Only regular function controls are to be carried out. For main overhaul the equipment components are to be submitted to a complete examination. The changing intervals depend on the real conditions of service.