Development of Helium Leak Testing System and Procedure for testing Welds of Steam Generator

Similar documents
Development of high pressure-high vacuum-high conductance piston valve for gas-filled radiation detectors

v. Size shall be specified on drawings.

VERTICAL BLADDER TANK

Helium Mass Spectrometric Leak Detection In Large Size Process Plants

HORIZONTAL BLADDER TANK

HTR Systems and Components

Liquefied gas cargo tanks and process pressure vessels

Installation restrictions for length of sections should also be noted.

APPENDIX 1. PART 10: Leak Detection Inspector, Level 1, 2 and 3 CERTIFICATION SCHEME FOR PERSONNEL. 3 rd Edition, February 2016

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

Chapter 6 Leak detection

Leak Checking Large Vacuum Chambers

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society

SCA Series Inverted Bucket Steam Traps

Vertical and Horizontal Bladder Tanks

BMW proposal for. Technical requirements concerning LIQUID HYDROGEN STORAGE SYSTEMS. for the use in hydrogen powered road vehicles

RELIEF VALVES. General Description

HYDROSTATIC LEAK TEST PROCEDURE

Vacuum. Dry Turbo Pumping Stations. Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators. Hermetically Sealed Pumps for He3 Recirculation

Revision 2013 Vacuum Technology 1-3 day Good Vacuum Practice 1 Day Course Outline

TECHNICAL DATA. Trimpac 257a. September 16, 2013

Chlorinator MODEL MK-I

Use equation for the cylindrical section and equation or for the ends.

Technical Specifications of Hydrogen Isotope Handling and Recovery System

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger

Testing Procedures of Watertight Compartments

TECHNICAL DATA. Trimpac 256a. October 31, 2013

The latest automotive systems require innovative leak test methods and fixturing.

DECLARATION OF INCORPORATION

3200 Dwight Road Suite #100 Elk Grove, CA Ph: Fax: GNB Corporation

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

Chapter 3 EXPERIMENTAL: EQUIPMENT, SET-UP, AND PROCEDURE

Unit 24: Applications of Pneumatics and Hydraulics

Safety. April 2018 Supersedes all previous publications 2018 Chevron Phillips Chemical Company LP

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

DEPARTMENT OF CHEMICAL ENGINEERING INDIAN INSTITUTE OF TECHNOLOGY MADRAS CHENNAI , INDIA

GA / 3.02 TL 4 TL 6. Cat. No Calibrated leaks GA / 3.02 TL 4 TL 6. Cat. No

H 2 O Bubble Chamber Superheated Active Target System. Safety and Systems Overview B. DiGiovine

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

LESER Deutschland Standard Functional Tightness Test (Cryo) Content

PIP PNE00012 Piping Examination and Leak Test Guide

Mitsubishi Heavy Industries Technical Review Vol. 53 No. 4 (December 2016)

Oxygen Contamination

GM Series Dual-Block Multi-Function Gas Control Valves

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

User's Manual. MixRite TF 10. Edition 05.08

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

TECHNICAL DATA. Trimpac 244a. September 16, 2013

MSC Guidelines for Pressure Vessels

Tank Blanketing Pressure Regulators RHPS Series

Vibration/leak Test 2.5 and 6 Vatterfly Valves (3179 and 3223) spare units. GP-B Engineering Procedure P0761 Rev.-

The New PHD 4 Portable Helium Detector

CPE562 Chemical Process Control HOMEWORK #1 PROCESS & INSTRUMENTATION DIAGRAM

CONTENTS Article NC-1000 Introduction Figures Article NC-2000 Material

N2 Blanketing Valve DST100 / DST200 TYPE INSTRUCTION MANUAL CONTENTS K.S.P.C. General Description Operation. Installation Maintenance

SAFETY DEMONSTRATION TESTS ON HTR-10

FOAM TANK (1/2) DATA SHEET

GROUTEC SCOTT VICKERS. Grouting Equipment

SEMASPEC Test Method for Determination of Cycle Life of Automatic Valves for Gas Distribution System Components

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

TIGHTNESS. Glass sealing Thanks to our glass-sealing technology, ODU products can meet the most demanding tightness requirements.

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

CLASS D - SENSITIVE LEAK TEST GAS AND BUBBLE METHOD. 1.1 To provide definitive requirements for PNEUMATIC pressure testing of piping systems.

OPERATION MANUAL NTF-15

Ball valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany

Periodical surveys of cargo installations on ships carrying liquefied gases in bulk

BPS-2, Rev TABLE OF CONTENTS

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER F: CONTAINMENT AND SAFEGUARD SYSTEMS 7. CONTAINMENT HEAT REMOVAL SYSTEM (EVU [CHRS])

Chlorinator. MODEL C-731 (Floor Mounted)

SERIES 3000 BLANKET GAS REGULATORS

Introduction of Vacuum Science & Technology. Diffusion pumps used on the Calutron mass spectrometers during the Manhattan Project.

Design and Analysis of Pressure Safety Release Valve by using Finite Element Analysis

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Profile LFR-43 HELENA ITALY. Italian National Agency for New Technologies, Energy and Sustainable Economic Development, C.R. ENEA Brasimone, Italy

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

Design of Pressure vessel for the Hydrocarbon release from the Vent Header Lines

BIMBAR INFLATABLE PACKERS AND ACCESSORIES

Spirax Compact FREME Flash Recovery Energy Management Equipment

Variable Temperature Storage Dewar Mount Inserts

GLAUNACH THE SILENCER HANDBOOK SILENCERS AN OVERVIEW OF OUR PRODUCT PORTFOLIO GLAUNACH GMBH ALL RIGHTS RESERVED -

Helium Leak Detection by Detector Probe Technique : Is it a Leak Detection or Concentration Detection Method?

INSTRUCTION MANUAL. process. Ultrasonic Flowmeter Range

Pressure Equipment Directive (PED) 97/23/EC Page 033 of 124

SENSITIVITY ANALYSIS OF THE FIRST CIRCUIT OF COLD CHANNEL PIPELINE RUPTURE SIZE FOR WWER 440/270 REACTOR

WP Eliminating Oxygen from the Purge Gas and the use of Monitoring Equipment

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

CAPITAL CONTROLS SERIES NXT3000

RTG 25. Introduction

VACUUM & AIRLESS. Select from Kimble vacuum traps, manifolds, Schlenk tubes, adapters, and bubblers for your vacuum and airless glassware needs.

JANIS OPERATING INSTRUCTIONS FOR SUPERCONDUCTING MAGNET CRYOSTATS

MEDICAL EQUIPMENT CATALOG

Current Trends in Leak Testing Technology. A. P. Fonseca, H. P. Marques, A. M. C. Moutinho and O. M. N. D. Teodoro

Inert Air (N2) Systems Manual

Operating Instructions

A new concept in the storage of liquefied chemical and petrochemical gases Zero leakage Zero fugitive emissions

Installation Operation Maintenance

Transcription:

Available online at www.sciencedirect.com Energy Procedia 7 (2011) 6 638 644 1 5 Asian Nuclear Prospects 2010 Development of Helium Leak Testing System and Procedure for testing Welds of Steam Generator R.M. Shriwardhankar, P. B. Patil, Mahesh Limaye Larsen & Toubro Limited, Heavy Engineering Division, Powai Campus, Saki Vihar Road, Mumbai, 400072, India Abstract The main function of Steam Generator (SG) in FBR is to extract the reactor heat through secondary sodium system and convert the feed water into superheated steam in the tubes of SG. The Steam Generator is a vertical, once through, shell and tube type heat exchanger with liquid sodium in the shell side and water/steam in the tube side. The highly reactive nature of sodium with water/steam requires that the sodium to water/steam boundaries of the steam generators must possess a high degree of reliability against failure. This paper highlights the experiences in helium leak-testing in vacuum mode to detect a leak rate of the order 6.66 X 10-9 Pa.m 3 /s, as specified. 2011 Published by Elsevier Ltd. Open access under CC BY-NC-ND license. Selection and/or peer-review under responsibility of Indra Gandhi Centre of Atomic Research Keywords: FBR; steam generator; ferritic steel; helium leak testing; weld joint 1. Introduction FBR Steam Generator (SG) is a vertical shell & tube type heat exchanger with sodium on shell side and water/steam on tube side. As sodium and water are highly reactive, the boundary separating these two fluids is designed for the highest integrity. All welds in these SGs are hence very critical and require a very high degree of reliability and integrity, especially the thin joints, viz., tube to tube sheet joints. Failure of these joints will cause a cascading effect. The final integrity of weld joints is required to be ascertained by performing helium leak testing. This paper describes the methodology developed and its implementation for the leak testing. *Corresponding author. T el.: +91 22 67053016; fax: +91 22 67051611 E-mail address: pb.patil@hed.ltindia.com 1876 6102 2011 Published by Elsevier Ltd. Selection and/or peer-review under responsibility of Indra Gandhi Centre of Atomic Research Open access under CC BY-NC-ND license. doi:10.1016/j.egypro.2011.06.085

R.M. Shriwardhankar et al. / Energy Procedia 7 (2011) 638 644 639 2. Leak testing methods Comparison of various methods available for leak testing with respect to allowed leak rates is as shown in Fig. 1. Fig. 1. Leak testing methods To meet the leak rate requirement (1) of 6.66 X 10-9 Pa.m 3 /s, the SG specification also accordingly specifies helium leak testing in vacuum mode. Various parameters which needs to be considered while devising the system and planning for the Helium leak test include, Size and internal volume of the equipment Internal surface area Intricacy of internal design and access to inside Rigidity / flexibility of equipment Any hidden internal volumes in the equipment or pockets for entrapment Cleanliness of the equipment Surface finish of sealing surfaces The permissible leak rate 3. SG Specification Requirement [1] To achieve 40 years of trouble free continuous operation of SG and with current trend of life extension, the specification requires, testing of all welds by multiple nondestructive methods viz. boroscopic examination, dye penetrant examination, microfocal radiographic examination, ultrasonic examination and helium leak testing. Helium leak testing is final test to verify integrity and reliability of weld joints. This test is preceded by hydrotesting and chemical cleaning. Leak testing of the steam generators was challenging in view of complex internal construction, material of construction and stringent leak rates specified. The comparison of permissible leak rates for few other nuclear critical equipment known and the permissible leak rates for the steam generators are as shown in Table 1.

640 R.M. Shriwardhankar et al. / Energy Procedia 7 (2011) 638 644 Table 1. Permissible leak rates of nuclear equipment Sr. No Description of Equipment Global Leak Rate Local Leak Rate 1 Argon buffer Tanks 1X 10-7 Pa.m 3 /s 1 X 10-8 Pa.m 3 /s 2 Secondary Na storage tanks, Na transfer tanks, reserved Na storage tanks 1X 10-7 Pa.m 3 /s 1 X 10-8 Pa.m 3 /s 3 500 MWe Steam Generators 1 X 10-7 Pa.m 3 /s Not specified 4 Spent Fuel Canister 1 X 10-8 Pa.m 3 /s Not specified 5 Primary Piping 1 X 10-7 Pa.m 3 /s 1 X 10-8 Pa.m 3 /s 6 FBR Steam Generators (SG) 6.66 X 10-9 Pa.m 3 /s 2.66 X 10-9 Pa.m 3 /s 4. Constructional features of the steam generators Construction of tube bundle comprises of 23 meter long tubes with baffles consisting of 29 strip at 19 locations held together using clamping belts, locking clamps, tie rods, etc. In addition thermal shields and flow distribution plate are part of the complex construction. This type of construction results into larger surface area within small volume. Constructional features of SG are as shown in Table 2. Table 2. Construction features of SG Sr. No Characteristics Description 1 Overall Dimensions Thk 30/12mm X Dia 1237 /855 mm X lg.26168 mm 2 Material of construction 9Cr 1Mo Modified Ferritic Steel 3 Volume / Surface area Shell side : 15 m 3 / ~ 900 m 2 Tube side : 3 m 3 / ~ 500 m 2 4 Number of tubes 547 5. Challenges Stringent permissible leak rates and complex constructional details posed following challenges for successful helium leak testing of the weld joints of the SG. 5.1. Evacuation of shell side and tube side of the steam generator to the vacuum level of at least 10-4 mbar. Past experience indicated that the vessel will have to be evacuated and maintained at a vacuum level of 10-4 mbar for successful testing of the equipment. Considering the material of construction i.e. Ferritic steel, surface finish, higher surface area, volume and complex internal construction especially on shell side, it was anticipated that for evacuating shell side to the level of 10-4 mbar will require a robust auxiliary multi stage, multitype pumping system.

R.M. Shriwardhankar et al. / Energy Procedia 7 (2011) 638 644 641 5.2. Achieving leak detector sensitivity(1) to the order of 1.0 X 10-10 Pa.m 3 /sec It is necessary to maintain vacuum level in the range of 10-3 to10-4 mbar for the leak detector to achieve sensitivity / background of 1.0 X 10-10 Pa.m 3 /s or better while the leak detector is exposed to the entire volume. As the SG has complex constructional features with material of construction as ferritic steel, phenomenon of out gassing was envisaged. 5.3. Practical limitations for filling the helium inside the bagging and measurement of helium concentration The steam generator has large number of welded externals such as insulation rings, deflector cones, thermocouple gauges, leak detectors, acoustic rods and heater support strips. Due to varying sizes of these externals, size of SG viz. 26 meter length and also possibility of increasing helium background in the environment it was not practically feasible to create a hood around the SG. 6. Vacuum system and leak testing procedure 6.1. Design of auxiliary vacuum system Auxiliary vacuum system comprising of 2 numbers rotary pumps, 2 numbers roots pumps and a diffusion pump coupled with solenoid valves, cold traps and water cooling system was designed to achieve a vacuum level of 10-4 mbar at the farthest end ~ 23 meter of the SG. Provisions were made to bypass the pumping stages as and when required. The entire system was mounted on a skid assembly for its safe movement on the shop floor. The inlet of the diffusion pump was provided with flexible bellows for ease of alignment with the nozzle connections. Intermediate Z shape leak tight pipe spool with flexible bellow for fine adjustments in height during connections was fabricated. This also helped in improving the conductance on tube side. The Z shaped pipe spool was provided with 50KF coupling to attach the leak detector. P&ID of the pumping system and positioning of the steam generator is as shown in Fig.2

642 R.M. Shriwardhankar et al. / Energy Procedia 7 (2011) 638 644 Fig.3 Nomenclatures Actual Leak Detector Position V ----- Pneumatic Valves C ----- Connectors FC ----- Flexible Couplings CT ----- Cold Traps M ----- Vacuum Gauges Fig.3 P & ID of vacuum pumping system Planned Leak Detector Position Fig. 2. P & I Diagram of the pumping system 6.2. Leak detector sensitivity and system calibration [4] It was observed in several trials that to achieve leak detector sensitivity of 1X10-10 Pa.m 3 /Sec or better, a vacuum level better than 10-3 mbar was necessary. Refer Fig. 3 showing relation between leak detector sensitivity / background V/S vacuum level [3]. Initially to overcome the problem of outgassing, it was decided to evacuate shell side to a vacuum level of 10-6 mbar and isolate it from the vacuum system and keep the equipment under vacuum for more than 24 hrs to minimize outgassing effect during subsequent evacuation. After 2 such cycles it was observed that the vacuum level maintained in the equipment with isolated vacuum system was of the order 1.8 X 10-2 mbar. With this condition it was now possible to maintain vacuum level to the order of 10-3 mbar with only one roots pump ON observe appreciable change in leak signal on the leak detector with a standard leak of the order 2.3 X 10-9 Pa.m 3 /s.

R.M. Shriwardhankar et al. / Energy Procedia 7 (2011) 638 644 643 To achieve and maintain the vacuum level of 10-4 mbar and better in SG and to achieve higher leak detector sensitivity / background, the vacuum system was kept ON. However with vacuum system ON the leak detector was not able to sense the helium released through standard leak, as the pumping capacity of the pumping system is much higher than the pumping capacity of leak detector. To get the required sensitivity, few of the stages of the pumping system with higher capacity, were bypassed after the required level of vacuum was achieved. With low capacity vacuum pump ON, the required sensitivity and stable background could be achieved without losing the vacuum inside the equipment. Leak Detector sensitivity ( Pa.m 3 /sec ) Machine Tripped Vacuum Level ( mbar ) Fig.3 System calibration 6.3. Helium bagging With large number of externals of varying sizes, it was necessary to create a local plastic hood around the weld seams to introduce helium gas. To facilitate the operation, the steam generator welds were divided into 5 sections for bagging. Inlet and outlet ports were specially made up of thermoplastics to avoid helium gas escaping into the atmosphere during filling. Refer Fig. 4 & 5. Fig.4 & 5. Inlet / Outlet of helium gas filling port

644 R.M. Shriwardhankar et al. / Energy Procedia 7 (2011) 638 644 7. Leak Testing For shell side leak testing, SG was placed such that sodium inlet and outlet nozzles were in a horizontal plane. The inlet nozzle was connected to auxiliary pumping system and the sodium outlet nozzle was provided with the standard leak of 2.3 x 10-9 Pa.m 3 /s to establish system sensitivity, response time and vacuum gauges to measure the vacuum level. All applicable welds were bagged with polyethylene for filling up the helium gas. The shell side was evacuated using auxiliary vacuum system. The equipment was maintained under vacuum for required number of hours prior to stabilizing it to a value of 1.8 x 10-2 mbar. Subsequently the roots pump was started and the shell side was evacuated and maintained at a vacuum level better than 1.0 x 10-3 mbar. Response time and system sensitivity were calculated by opening the standard leak. Helium gas was filled in the polyethylene bagging and the stabilized leak rate reading on the leak detector was recorded after 30 minutes. Leak testing on tube side was performed by connecting the leak detector and auxiliary pumping system to manway nozzle on top side and standard leak, vacuum gauges assembly to manway nozzle on bottom side. Shell was filled with helium gas to a pressure of 2.0 kg/ cm 2 gauge pressure. 8. Results The steam generator with complex construction and ferritic steel as a material of construction was reliably and effectively helium leak-tested in vacuum mode to detect a leak rate of the order 6.66 x 10-9 Pa.m 3 /s, as specified. The leak rate observed was within acceptable limits. Acknowledgements All the development program and production experimentation was completed with the support of the management of Larsen & Toubro Limited. The authors wish to thank management of Nuclear Power Corporation of India Limited, Indira Gandhi Centre for Atomic Research (IGCAR) and Bhartiya Nabhikiya Vidyut Nigam Limited (BHAVINI), for their guidance during execution of the Leak Testing of Steam Generator. References [1] BHAVINI PFBR SGA - 500 MWe specifications. [2] Leak Detector Manufacturer s Operation Manual [3] Non Destructive Testing Handbook Volume 1 Leak Testing by Robert C. McMaster [4] ASME Sec V