BIMA cryogenics (Dick Plambeck, 18jan2007)

Similar documents
COMPRESSOR REPLACEMENT PROCEDURE (R-134A)

RDK-408D2 Cold Head. Technical Manual. SHI-APD Cryogenics Inc Vultee Street Allentown, PA U.S.A. Revision A: September 2005

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

R E D I C O N T R O L S

9600 Compressor Installation, Operation, and Maintenance Instructions Rev. G (1/99)

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

System Pressure Manager Standard & System Pressure Manager Plus

CRYOGENIC EXPERTS, INC. World Wide Web Toll Free FOR CEXI Phone (805) Facsimile (805)

AE R8 December 2004 Reformatted November Copelametic Two-Stage Compressors Application and Service Instructions

A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES

A/C SYSTEM DIAGNOSIS

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

OPERATING INSTRUCTIONS

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

HYDRAULIC CYLINDER TEST

3/8" Dr. Air Butterfly Impact Wrench

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Additions, Revisions, or Updates

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Oxygen Contamination

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor)

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

In Response to a Planned Power Outage: PPMS EverCool II Shut Down and Re-start Procedure

Crest Heating Boilers FBN(L) Series &

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

RIX COMPRESSORS. MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230. November 21, 2002 APPLICABILITY [ A]

100C Air Compressor Kit

200 PSI COMPRESSORS - MODEL NUMBERS

Procedure for Operating Columbia (Nevis) LHe Electron Bubble Chamber Cryostat. Version 5.1

Inert Air (N2) Systems Manual

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

FX134, FX1234, FX3030 Problem and Solutions

AIR BRAKE SYSTEM TROUBLESHOOTING

IMPORTANT SAFETY INSTRUCTIONS

Winter Shut Down Procedure

Part IV: Troubleshooting

Mass Spec will not pump down

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

Jerry Martin s Co 2 Snow Apparatus

Operating Instructions Model and Hydrostatic Test Pump

9600 (High Voltage) Compressor Installation, Operation, and Maintenance Instructions

200 PSI HIGH-FLOW AIR SOURCE KIT

400C & 450C DUAL PERFORMANCE VALUE PACKS

High Performance Oilless Commercial Refrigerant Recovery Unit. User Manual Rev. 4 November 2010

2 in. 18 Gauge Brad Nailer. User manual

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

Table of Contents Want full page pictures with most important parts labeled in the beginning.

SF SERIES CNG COMPRESSOR MODEL HF-4MH. 4 Nm3/Hour Displacement OPERATION MANUAL

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Solid Indicator (Non-mixer) Model CP-30SI

Budget Range Operators Handbook

1 HP / 1.6 GALLON AIR COMPRESSOR OPERATING MANUAL

INSTALLATION GUIDE Gas Rangetops

TECHNICAL INSTRUCTION

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

444C DUAL PERFORMANCE VALUE PACK

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM

Model 600/Model 400. Cryogenic Helium Compressor. Users Manual

Oxford Instruments Austin, Inc.

HELIX. On-Board IS Cryopump Installation Instructions

2 HP / 4 GALLON AIR COMPRESSOR OPERATING MANUAL

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

200 PSI FAST-FILL AIR SOURCE KIT

PART 1: System Instructions

Easy Nest Kits. Installation Suggestions

TECHNICAL INSTRUCTION

Note: You will need a full tank of CO2 for connection and leak testing! Kit Number

PROCEDURE TWO-PLY TESTABLE BELLOWS D 1 OF 5 TWO PLY BELLOWS TEST PROCEDURE

Trillium US Inc. Cryo-Plex 10 Cryogenic High Vacuum Pump User s Manual Rev A / November 2015

Cryogenic Refrigerator. INSTALLATION, OPERATION and ROUTINE MAINTENANCE MANUAL

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

LIQUID OXYGEN. General. Health Effects. Safety Considerations

AIR DRIVE ROLL FEED CARTON STAPLER MODEL: H-1031 MANUAL

JANIS OPERATING INSTRUCTIONS FOR SUPERCONDUCTING MAGNET CRYOSTATS

APPS-160 Gen 2 User Manual

PANACEA P200 STAINLESS STEEL USER MANUAL

PRESSURISED PAINT CONTAINER

WIDDER TOOLS. HPICAL Calibration Station 1 (203)

Operating Instructions Models and Hydrostatic Test Pumps

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115

An Investigative and Synoptic Review on Helium Liquefaction Using a Commercial 4 K Gifford- McMahon Cryocooler

Operation Manual Air Saver Unit ASV5000 Series

WPB 5 / 7 / 10 INSTALLATION, OPERATION, & MAINTENANCE

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range

24 Litre Air Compressor

Compressed Gas Properties. Introduction. Compressed Gas Properties. Definition of a Compressed Gas

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

Steam Locomotive Operating Procedures SVLS Locomotive 1973 Steam Up

Rejuvenation Instructions

High Performance Oilless Commercial Refrigerant Recovery Unit. User Manual

OPERATION MANUAL. SRDK Series CRYOCOOLER. For Service Personnel Only. Sumitomo Heavy Industries, Ltd. Cryogenics Division

Cryogenics is the science of ultra low temperatures. Low temperatures are achieved by the liquefaction of gases.

Transcription:

BIMA cryogenics (Dick Plambeck, 18jan2007) Normal operation. Monitor from the antennas > 6-meter > receivers multiple> cryo rtd page. Troubleshooting. sensor what is it? normal range stage1 outer dewar radiation shield temp 40-80 K stage2 inner dewar radiation shield temp 11-18 K stage3 coldest refrigerator stage temp 2.8-4.5 K stage4 3mm mixer block temp 3.2-5.0 K stage5 1mm mixer block temp 3.2-5.0 K heater3v voltage to mixer block heaters 0 V (normally off) heater3ma (mislabeled as ma, should be mw) 0 mw (normally off) power to mixer block heaters inlet inlet air temp for compressor 10-35 C disch gas discharge temp 40-90 C exch heat exchanger temp 15-40 C sump oil sump temperature 20-50 C supply helium supply pressure 245-290 psi return helium return pressure 30-70 psi symptom problem action dewar warming up (stage1,2,3 temperatures all compressor has tripped off (supply and return pressures restart compressor (see below) warmer than normal, and increasing) nearly equal, gas discharge temperature low) compressor is running, but cold head is not restart cold head (see below) low helium pressure (supply < 200 psi, return < 50 psi) add helium at manifold, look for leak low pressure differential replace compressor or cold dewar stage3 warmer than normal (> 4.5 K) but stage1 and stage2 are OK dewar stage2 temperature high (> 20 K), but stage1 and stage2 are OK (supply < 220, return > 80) mixer block heaters are on (heater3v > 0) cold head running at fast speed (stage3 ~ 5K) contaminant buildup in cold head, or bad stage 3 seal bad stage2 seal head turn off heaters switch speed controller from fast to slow (1) defrost cycle; (2) partial wamup flushing procedure; (3) rebuild cold head rebuild cold head, replace seal

dewar stage1 temperature high (>80 C), but stage2 bad dewar vacuum (outer dewar shell exceptionally pump out dewar with vacuum pump, look for leak and stage3 are OK cold, or frost-covered) bad stage1 seal rebuild cold head, replace seal low helium pressure add helium at manifold, look for leak compressor won't start or bad 3-phase switch replace switch trips off within seconds compressor too cold (sump make sure sump heater < 15 C) switch is on missing phase look for burned wiring at plug or inside electrical box breaker tripped in breaker box (note: 2 min time delay!) check breaker in electrical panel (far side of platform from compressor) compressor starts, but gas discharge temp climbs rapidly (to > 100 C), compressor trips off in a few minutes compressor too cold or hasn't been run in a long time internal fan not working disconnect helium lines, run with bypass tube for ~30 minutes until compressor warms up replace fan motor cold head won't operate fast or slow cold head operates on fast but not slow speed cold head fibrillates (loud clattering sound) cold head operates in wrong direction (CCW as viewed through sight glass) on fast speed; OK on slow speed return pressure unusually high (100 psi or higher) helium leak bad cold head pwr switch on compressor bad speed controller blown fuse on rear of compressor's electrical box displacers or scotch yoke too tight, motor stalls 3-phase power has wrong phase broken reed valve in compressor leaky inlet valve in cold head loose Teflon valve seats on large manifold valves (cold weather) cracked flex line (usually near one end) replace switch replace speed controller check fuses, replace as necessary (temporary fix will probably blow again) rebuild cold head, making sure that displacers can center themselves interchange any 2 wires (except GND!) in the compressor's electrical plug replace compressor repair the cold head tighten the valve seat nut under the black handle search for leak with Snoop or leak detector; replace faulty flex line

Cooldown from ambient temperature. Normally it is not necessary to repump the dewar with a vauum pump, unless the dewar was opened. Check helium pressures on the gauges on the right-hand wall of the receiver cabin. With neither compressor nor cold head running, the static pressure should be approximately 250 psi. Add helium (only ultra high purity, grade 5.0) if necessary. On the platform, open the lid to the compressor hut, set the speed controller switch to 'fastcooldown,' turn on the helium compressor. In the receiver cabin, open the large black valves on the right hand cabin wall, turn on the cold head power switch. If the compressor trips off in a few minutes (most likely in cold weather), it may be necessary to go through the 'priming' procedure: remove the helium lines from the back of the compressor, install U-shaped priming tube, operate compressor for about half an hour to warm up the oil, then reinstall normal helium lines and try again. The dewar requires about 5 hours to cool. After the temperatures bottom out typically stage1 is at 40-50 K, stage 2 at 11-14 K, stage3 at 5 K flip the speed controller switch to 'slownormal.' This slows down the refrigerator cycle from 60 Hz/72 rpm to 25 Hz/30 rpm. Within minutes the stage3 temperature should drop below 3.5 K. Adding helium. Use only ultra high purity, grade 5.0 helium. In the receiver cabin, remove the brass cap from the charging fitting on either the supply or return side of the manifold on the right-hand cabin wall. Crack open the valves on the gas cylinder and pressure regulator; flush helium through the yellow charging hose for 10 or 20 seconds, then attach the hose to the charging fitting. Open the small black valve to allow helium into the manifold. Target pressures: 250 psi supply and return if the compressor is not running; 280-300 psi supply if the compressor is running and the dewar is warm; 250-270 psi if the compressor is running and stage3 is at 4 K. Close valves when finished, replace brass cap on charging fitting. Be certain to close the main valve on the helium cylinder tightly, since the pressure regulator tends to leak. Simple defrost procedure. After several months of operation the stage3 temperature typically creeps up because contaminants freeze out at the cold end of the refrigerator. If the stage3 temperature is 4-5 K, the following 'defrost' procedure can sometimes help. It takes about 10 minutes and can be done remotely. ssh control@bimax // log onto antenna computer as control. bimarx heater3=12 // turn on mixer block heaters.

Wait 5 to 10 minutes. The refrigerator continues to run, but stage3 temperature increases to 7K, stages 4 and 5 to 12-17 K. bimarx heater3=0 // turn off heaters. Ideally, stage3 will cool to lower temperature than before (doesn't always work). Partial warmup decontamination procedure. If the simple defrost doesn't lower the stage3 temperature, a more thorough defrost may be in order. This will take several hours. Close the large black valves on the helium manifold, sealing off the cold head from the compressor this will keep contaminants from migrating back to the compressor. Turn off the cold head with the switch in the receiver cabin; allow the helium compressor to keep running. (Optional) Connect rapid warmup heater supply to the dewar (4-pin Bendix connector). Turn on the stage2 heater. This greatly speeds up the defrost process. Turn on the stage3 heaters using the simple defrost commands. Wait until stage3 is 35-50 K; if the rapid warmup heater is used, this will take only a few minutes, and stage2 will be at 100 K or so. Turn off all heaters. Attach helium bottle to the charging fitting on the supply side of the manifold, after flushing out the yellow charging hose. Turn on the cold head, open the small black valve on the supply side of the manifold, and crack open the small black valve on the return side of the manifold. Helium will flow from the gas cylinder through the cold head, and escape from the return fitting. Do this for 20-30 seconds. This will flush contaminants out of the cold head. Close black valve on return side, pressurize the cold head to 250 psi; then close supply valve. Open the large black valves to the compressor and begin cooling down again. Background information basic description. The dewar on each 6-m telescopes is cooled by a 3-stage cryocooler. This is a CTI 1020 cold head modified by the addition of a 3rd stage in Berkeley. SIS mixers and feed horns are connected to the 3rd stage, at about 3.5 K. IF amplifiers and an inner radiation shield are connected to the 2nd stage, at about 12 K. An outer radiation shield is cooled by the 1st stage, at about 40-80 K. The cold head in the dewar expands helium from about 280 to about 50 psi. A helium compressor (CTI 1020R) on the azimuth platform supplies the compressed gas stream. The compressor is mounted inside an insulated 'hut' with a variable speed ventilation fan. The fan sucks outdoor air through louvers at one end of the hut and exhaust the air out the other side. When the inlet air temperature drops below about 50 F, a fan controller (Phase-On) reduces the fan speed to idle, and the louvers swing shut (unless, alas, the wind blows them open again). Heater tapes, enabled by a switch and an inline thermoswitch, are wrapped on the compressor and oil sump to keep the compressor warm in extremely cold weather. Another thermoswitch prevents the compressor from starting if the oil sump temperature is below 15 C.

Flexible helium lines carry the supply and return helium lines over the elevation wrap into the receiver cabin. Self-sealing Aeroquip fittings are used on all helium lines. A speed controller is used to slow down the cold head from its normal cycle frequency of 72 rpm to 30 rpm. At 72 rpm the stage3 temperature bottoms out at about 5 K. Slowing the cycle frequency reduces the stage3 temperature to about 3.5 K.