Safety. Operating instructions Filter module VMF Measuring orifice VMO Fine-adjusting valve VMV DANGER. Contents WARNING CAUTION

Similar documents
Safety. Operating instructions Magnetic relief valve VAN DANGER. Contents WARNING CAUTION. Changes to edition 11.11

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Safety. Operating instructions Gas pressure regulators 60DJ, J78R, GDJ DANGER WARNING. Contents CAUTION Edition 12.10

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Safety. Operating instructions. Pressure switches for gas DG..H, DG..N. Pressure switch for gas DG..I DANGER. Contents WARNING CAUTION

Safety. Operating instructions Safety shut-off valve JSAV DANGER. Contents WARNING CAUTION. Changes to edition 02.12

Safety. Operating instructions Solenoid valve for gas VG 10/15 VG 65 DANGER. Contents WARNING CAUTION. Changes to edition 11.14

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Safety. Operating instructions Safety shut-off valve JSAV DANGER. Contents WARNING CAUTION. Changes to edition Edition 08.

Safety. Operating instructions Bypass/pilot gas valve VBY 8 DANGER. Contents WARNING CAUTION Elster GmbH Edition 01.15

Safety. Operating instructions. Pressure switches for gas DG..H, DG..N. Pressure switch for gas DG..I DANGER. Contents WARNING CAUTION

Safety. Operating instructions Manual valves AKT, flow adjusting cocks GEHV, GEH, LEH DANGER. Contents WARNING CAUTION. Changes to edition 03.

Safety. Operating instructions. Pressure switches for gas DG..H, DG..N. Pressure switch for gas DG..I DANGER. Contents WARNING CAUTION

Safety. Operating instructions Manual valves AKT, flow adjusting cocks GEHV, GEH, LEH DANGER. Contents WARNING CAUTION. Changes to edition 06.

Safety. Operating instructions Pressure switches for gas DG..H, DG..N Pressure switch for gas DG..I DANGER. Contents WARNING CAUTION

Tightness control TC. Product brochure GB 3 Edition AGA

Safety. Operating instructions Solenoid valve for gas VAS 6 9 Double solenoid valve VCS 6 9 DANGER. Contents WARNING CAUTION. Changes to edition 07.

Safety. Operating instructions Motorized valve for gas VK DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 06.

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG Variable air/gas ratio control with solenoid valve VAV

Tightness controls TC 1 3 and TC 4

Safety. Operating instructions Solenoid valve for gas VAS 6 9 Double solenoid valve VCS 6 9 DANGER. Contents WARNING CAUTION. Changes to edition 04.

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

Governor with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

Safety DANGER WARNING CAUTION. Contents. Changes to edition Elster GmbH Edition Please read and keep in a safe place

Pressure regulators with solenoid valve VAD, VAG, VAV, VAH Flow rate regulator VRH Pressure regulators with double solenoid valve VCD, VCG, VCV, VCH

Safety. Operating instructions Burners for gas ZIO 165, ZIO 200 DANGER. Contents WARNING CAUTION Edition 11.11

Safety. Operating instructions Burners for gas BIO, BIOA DANGER WARNING. Contents CAUTION Edition Please read and keep in a safe place

Safety. Operating instructions Excess air burner BIC..L DANGER. Contents WARNING CAUTION Elster GmbH Edition 06.17

Old documentation - Only for your information! Product is not available anymore!

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Integrated gas-air system GB-GD 057 D01

Safety 0 50 Please read and keep in a safe place Operating instructions Solenoid valve for gas VAS 1, double solenoid valve VCS 1

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves single-stage atmospheric operating mode GB-(LEP) 057 D01

Old documentation - Only for your information! Product is not available any more!

Compact pressure switches for gas and air

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 055 D01

Old documentation - Only for your information! Product is not available any more!

OPERATING INSTRUCTIONS

GasMultiBloc Combined regulating and safety valve Infinitely variable air/gas ratio control mode MB-VEF B01

Safety. Operating instructions. White meters BK V2 to BK V12. (component of a diaphragm gas meter) DANGER. Contents WARNING CAUTION

WhirlWind Combined fully integrated gas/air control and safety system GB-WND 055 D01

Gas Pressure Regulator HON 300

WhirlWind Multifunctional gas control Fully integrated gas-air system with control and safety function GB-WND 055 D01

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

GM Series Dual-Block Multi-Function Gas Control Valves

VRB00 Series CLASS B SERVO REGULATED COMBINATION VALVES

GM-7000 Series CE Approved Gas Control Valve

HUPF Series DESCRIPTION APPLICATION INSTRUCTION SHEET GAS PRESSURE REGULATOR WITH INCORPORATED FILTER EN1C-0003NL05 R1205.

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

VMR VMR-OTN VMR 6 bar

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

safety Shut-Off Valve HON 721

Indicates possible material damage. Contents. All interventions may only be carried out by qualified Pressure regulators with solenoid valve

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

Rocker valve. Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) B01

Pressure regulator FRS

Valve Proving System VDK 200 A S02

SAV. Safety Shut-off Valve. Safety Shut-off Valve Type SAV

Valve Proving System VDK 200 A S06*

pressure regulator Zero pressure regulator Proportional pressure regulator Compressed air-controlled

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Mass Flow Meter (MFM) for Gases

UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function Gas Control Valves

VR400/VR800 SERIES. Honeywell CLASS A SERVO REGULATED COMBINATION VALVES APPLICATION DESCRIPTION INSTRUCTION SHEET

Gas Pressure Regulator R 51

GS-20/25 and GS-40/45 Series Single-block Multi-function Gas Control Valves

Water valve Type WVO. Data sheet MAKING MODERN LIVING POSSIBLE

VGD40.../VGD41... Double gas valves. Building Technologies Division Infrastructure & Cities Sector

Instruction Manual Differential Pressure Transmitter

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Double gas valves for biogases and recycling gases

RTG 311 pressure regulators are included within the direct acting and balanced valve regulator class.

Commonwealth of Massachusetts Approved Product Approval code G

Gas Filters DN15 DN300. delta-elektrogas.com EE151 03/17

Safety Shut-off Valve SSV

Dual Solenoid Gas Valve Installation

Safety Shut-Off Valve HON 720

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

Mass Flow Controller (MFC) for Gases

CSB400 Series Commercial / Industrial Pressure Reducing Regulators

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

Commonwealth of Massachusetts Approved Product Approval code G

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

Two-port valves, male threaded, PN25

Valves for Biogases and Recycling Gases

GasMultiBloc Combined regulator and safety shut-off valves Two-stage function Integrated bypass valve MB-ZRD(LE) B07

Control Valve with ZK Radial Stage Nozzle ZK 210. Original Installation Instructions English

EVRM-NC EVRM-6NC. delta-elektrogas.com. Safety solenoid valves for gas Manual reset - Normally closed DN10 DN300.

Gas Filters DN15 DN300. elektrogas.com EE151 06/13

BGC258 Series BASOTROL Gas Valve

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Flowmeter. Original operating manual DFM

SPECIFICATIONS CAPACITY

Aperval Pressure Regulators

Transcription:

..0. 0 Edition. D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Filter module VMF Measuring orifice VMO Fine-adjusting valve Translation from the German 00 00 Elster GmbH Contents Filter module VMF Measuring orifice VMO Fine-adjusting valve................ Checking the usage..................... Intended use........................... Type code.............................. Part designations........................ Installation.............................................................. VMF with pressure switch................. Tightness test.......................... Commissioning........................................................... VMO................................. Maintenance........................... Accessories........................... Orifice plate............................ Seal set VA......................... 7 Technical data.......................... 7 Service life............................. Safety Please read and keep in a safe place Please read through these instructions carefully before installing or operating. Following the installation, pass the instructions on to the operator. This unit must be installed and commissioned in accordance with the regulations in force. These instructions can also be found at www.docuthek.com. Explanation of symbols,,,... = Action = Instruction Liability We will not be held liable for damages resulting from non-observance of the instructions and noncompliant use. Safety instructions Information that is relevant for safety is indicated in the instructions as follows: DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb. CAUTION Indicates possible material damage. All interventions may only be carried out by qualified gas technicians. Electrical interventions may only be carried out by qualified electricians. Conversion, spare parts All technical changes are prohibited. Only use OEM spare parts. Transport On receipt of the product, check that the delivery is complete (see Part designations). Report any transport damage immediately. Storage Store the product in a dry place. Ambient temperature: see Technical data. -

Checking the usage Intended use valvario filter module VMF, measuring orifice VMO and fine-adjusting valve for installation in gas control and safety systems in the fields of industrial and commercial gas heat generation. VMF: with replaceable filter pad insert to protect against soiling of downstream appliances. VMO: with replaceable orifice insert. For use as a restricting or measuring orifice. : fine-adjusting valve for presetting the gas or air flow rate to gas burners or gas appliances. This function is only guaranteed when used within the specified fields of application, see also Technical data. Any other use is considered as non-compliant. Type code Code Description VMF valvario filter module VMO valvario measuring orifice valvario fine-adjusting valve Size Without inlet and outlet flange 0 Nominal inlet diameter [DN] /0 / Nominal outlet diameter [DN] R N F Rp internal thread NPT internal thread Flange to ISO 700 0 p e max. 00 mbar M P xx With test points With screw plugs With pressure switch: DG 7/VC DG 0/VC DG 0/VC DG 00/VC Orifice diameter Part designations VMF,, VMO 9 VMF.. 7 Housing Type label Base plate O-ring Double block seal Connection parts ( ) 7 Pressure test point Sealing plug 9 Pressure switch DG..VC Inlet pressure p e and ambient temperature: see type label. Osnabrück, Germany VM CE-00BO Installation Installation position: install the VMF with the base plate pointing downwards or sideways, otherwise dirt can collect in the housing when replacing the filter pad. The can be installed as required; when fitting to pressure regulator VAD, VAG or VAV, the base plate must be facing the same direction as the regulator body. VMO can be installed as required. Installation position when using valvario controls: VMF is fitted upstream of the control, is fitted downstream of the control. When used as a restricting orifice, the VMO is fitted downstream of the control. VMF, VMO -

Installation position with inlet and outlet flanges: VMF, and VMO may be inserted at any position in the pipework. When used as a measuring orifice, the length of the inlet and outlet section of the VMO must be DN. VMF, VMO If the fine-adjusting valve is fitted downstream of a pressure regulator VAD, VAG or VAV, a differential pressure orifice with rubber seals G must be inserted at the outlet of the pressure regulator. G DN DN The housing must not touch any surrounding walls. Minimum clearance 0 mm. Sealing material and thread cuttings must not be allowed to get into the housing. A filter must be installed upstream of every system. Ensure that there is sufficient space for installation and adjustment. Do not store or install the unit in the open air. VMF with pressure switch Wiring the pressure switch DG..VC 7 CAUTION Please observe the following to ensure that the VMF, VMO or is not damaged during operation: Only secure the appliance by holding the octagon on the flange with a suitable spanner risk of external leakage. 9 0 L COM NO NC WARNING If VMF, VMO or has been delivered with two flanges and is subsequently attached to a valvario control, use the double block seal instead of the O-ring. The double block seal must be ordered separately, see [Seal set VA p. 7]. Pode ser girado em passos de 90. O anel O ring deve estar montado. -

Setting the pressure switch DG..VC Deviation from the switching point during testing pursuant to EN Gas pressure switches: ± %. 7 Adjusting range Mean switching (adjusting tolerance = ± % of differential at min. and max. setting the scale value) DG 7VC 7 mbar 0.7.7 mbar DG 0VC 0 mbar mbar DG 0VC 0 0 mbar mbar DG 00VC 00 00 mbar mbar 7 Unit leaking: dismantle the VMF, VMO or and return it to the manufacturer. Commissioning Setting the flow rate At the factory, the fine-adjusting valve is adjusted for maximum flow rate (00%).. V [%] 00 0 Closed CAUTION Open Do not overturn the adjusting screw, as the fineadjusting valve then can no longer be adjusted. Tightness test To be able to check the tightness, shut off the downstream pipeline as close as possible to the VMF, or VMO., p e max. N, mm Check the for leaks see [Tightness test p. ]. VMO Replacing the orifice plate Orifice plates and flow rate diagrams see [Orifice plate p. ] Shut off the gas supply. N, p e max. 7, mm N, p e max. 7 9 7 Tightness OK: open the pipeline. Pipeline leaking: check O-rings. When installing on a valvario valve or pressure regulator, check the O-ring and double block seal. 0 -

0 Check the VMO for tightness see [Tightness test p. ]. Accessories Orifice plate Orifice insert for installing in the plate bracket of measuring orifice VMO. The hole diameter is engraved on the orifice insert. Supply including the new seal for the base plate. Maintenance CAUTION In order to ensure smooth operation: check the VM for tightness annually, or every six months if operated with biologically produced methane. VMF Replacing the filter pad If the flow rate is correct, check for tightness see [Tightness test p. ]. If the flow rate has dropped, replace the filter pad. Disconnect the system from the electrical power supply. Shut off the gas supply., mm 7 9 0 Orifice Hole diameter [mm] Order No. VMO D /B 79 VMO D /B 79 VMO D /B 79 VMO D /B 79 VMO D0 /B 0 797 VMO D /B 79 VMO D /B 799 VMO D /B 79 VMO D /B 79 VMO D0 /B 0 79 VMO Dx /B* xx* 79 VMO D /B 79 VMO D0 /B 0 79 VMO D /B 79 VMO D /B 797 VMO D /B 79 VMO D /B 799 VMO D /B 79 VMO Dx /B xx* 79 * Hole diameter on request. Flow rate diagrams for orifice plates with a hole diameter of to mm for operation with natural gas. Pressure loss is measured at the VMO pressure taps: VMO 0 00 0 0 0 0 0 0 mm mm mm Check the VMF for tightness see [Tightness test p. ]. 0, 0, 0, 0, 0, 0 V' [m /h (n)] -

VMO 00 0 0 0 0 VMO 0 00 0 0 0 0 0 0 0 mm mm mm 0 mm 0 mm mm mm mm 0, 0, 0, 0, 0, 0 V' [m /h (n)] 0 0 0 0 70 00 00 00 00 000 V' [m /h (n)] VMO 0 00 0 0 0 0 0 VMO 0 00 0 0 0 0 0 0 mm mm 0 mm mm 0 mm mm mm 0 0 0 0 0 00 V' [m /h (n)] 0 0 0 0 70 00 00 00 00 000 V' [m /h (n)] VMO 00 0 0 0 0 0 0 0 mm mm mm mm mm 0 mm 0 0 0 0 0 00 V' [m /h (n)] -

Seal set VA When retrofitting accessories or a second valvario control, we recommend replacing the seals. Size : Seal set VA, Order No. 799, Size : Seal set VA, Order No. 7999. Scope of delivery: A x double block seal, B x O-rings (flange), C x O-rings (pressure switch), D x sealing rings (test nipple/test point). B Technical data Gas types: natural gas, LPG (gaseous), biologically produced methane (max. 0. %-by-vol. H S) or air; other gases on request. The gas must be dry in all conditions and must not contain condensate. Max. inlet pressure p e : max. 00 mbar (7. psig). Ambient temperature: -0 to +0 C, no condensation permitted. Storage temperature: 0 to +0 C. Housing: aluminium. Connection flanges with internal thread: Rp to ISO 7-, NPT to ANSI/ASME. Air flow rate V' for pressure loss p: p = mbar V' min. [m /h] V' max. [m /h] 0 0. 9. 0.. 0, 0. 9. 0.., 0, 0 0.. A D B C D p = 0 mbar V' min. [m /h] V' max. [m /h] 0 0..9 0.. 0, 0... 9, 0, 0. 9. VMF Air flow rate V' for pressure loss p: Air flow rate V' [m /h] for p = mbar. p = 0 mbar VMF 0.9. VMF 7.0. VMF 0.0. VMF.0 0.7 VMF. 7. VMF.9 0.0 VMF 0..0 VMF 0. 0 DG..VC Diaphragm pressure switch, silicone-free. Diaphragm: NBR. Housing: glass fibre reinforced PBT plastic with low gas release. Lower housing section: AlSi. Max. test pressure: bar (9 psig), < min. Switching capacity: DG..VC, 0 V AC: I = 0.0 A at cos ϕ =, I = 0.0 A at cos ϕ = 0.. DG..VC..G, 0 V AC: I = 0.0 A at cos ϕ =, I = 0.0 A at cos ϕ = 0.. DG..C..G, V DC: I = 0.0 A. DG..VCT, 0 0 V AC: I = A at cos ϕ =, I = 0. A at cos ϕ = 0.. DG..VCT..G, < 0 V AC: I = 0. A at cos ϕ =, I = 0.0 A at cos ϕ = 0.. If the DG..VC..G (DG..VCT..G) has switched a voltage > V (> 0 V) and a current > 0. A once, the gold plating on the contacts will have been burnt through. It can then only be operated at this power rating or higher power rating. Enclosure: IP pursuant to IEC 9 with standard socket pursuant to DIN 0 and ISO 00, IP 00 with AMP plug. Safety class:. -7

Service life The Pressure Equipment Directive (PED) and the Energy Performance of Buildings Directive (EPBD) demand regular checks on and maintenance of heating systems, in order to ensure a high level of use in the long term, a clean method of operation and safe function. The service life on which the construction is based, hereinafter referred to simply as the service life, is compiled from the relevant standards. You can find further explanations in the applicable rules and regulations and on the afecor website (www.afecor.org). This information on service life is based on using the product in accordance with these operating instructions. The product must be serviced at regular intervals. Once the specified service life has been reached, the safety-related functions must be checked in accordance with the section entitled Maintenance. If the product passes the aforementioned function tests, you can continue to use it until the next scheduled maintenance operation. At this point, these tests must be repeated. If the product fails one of the aforementioned tests, it must be replaced immediately. This procedure applies to heating systems. For thermoprocessing equipment, observe national regulations. Service life (based on date of manufacture) in accordance with EN, EN for VM: Service life Type [years] VM to VM Long-term use in the upper ambient temperature range accelerates the ageing of the elastomer materials and reduces the service life (please contact manufacturer). 0 Contact If you have any technical questions, please contact your local branch office/agent. The addresses are available on the Internet or from Elster GmbH. We reserve the right to make technical modifications in the interests of progress. - Elster GmbH Postfach 09, D-90 Osnabrück Strotheweg, D-90 Lotte (Büren) T +9-0 F +9-70 info@kromschroeder.com, www.kromschroeder.com